• Title/Summary/Keyword: Light propagation

Search Result 322, Processing Time 0.033 seconds

Near-field Characterization on Light Emanated from Subwavelength Plasmonic Double Slit of Finite Length

  • Kim, Ki-Young;Goncharenko, Anatoliy V.;Hong, Jian-Shiung;Chen, Kuan-Ren
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.196-201
    • /
    • 2011
  • Near-field properties of light emanated from a subwavelength double slit of finite length in a thin metal film, which is essential for understanding fundamental physical mechanisms for near-field optical beam manipulations and various potential nanophotonic device applications, is investigated by using a three-dimensional finite-difference time-domain method. Near-field intensity distribution along the propagation direction of light after passing through the slit has been obtained from the phase relation of transverse electric and magnetic fields and the wave impedance. It is found that the near field of emerged light from the both slits is evanescent, that is consistent with conventional surface plasmon localization near the metal surface. Due to the finite of the slit, the amplitude of this evanescent field does not monotonically approach to than of the infinite slit as the slit length increases, i.e. the near-field of the longer slit along the center line can be weaker than that of the shorter one.

Growth of Runner Plants Grown in a Plant Factory as Affected by Light Intensity and Container Volume

  • Park, Seon Woo;Kwack, Yurina;Chun, Changhoo
    • Horticultural Science & Technology
    • /
    • v.35 no.4
    • /
    • pp.439-445
    • /
    • 2017
  • Transplant production in a plant factory with artificial lighting provides several benefits; (1) rapid and uniform transplant production, (2) high production rate per unit area, and (3) production of disease free transplants production. To improve the growth of runner plants when strawberry transplants are produced in a plant factory, we conducted two experiments to investigate (1) the effect of different light intensity for stock and runner plants on the growth of runner plants, and (2) the effect of different container volume for runner plants on their growth. When the stock and runner plants were grown under nine different light conditions composed of three different light intensities (100, 200, and $400{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ PPF) for each stock and runner plants, increasing the light intensity for stock plants promoted the growth of runner plants, however, the growth of runner plants was not enhanced by increasing the light intensity for runner plants under same light intensity condition for stock plants. We also cultivated runner plants using plug trays with four different container volumes (21, 34, 73, and 150 mL) for 20 days after placing the stock plants, and found that using plug trays with lager container volume did not enhance the growth of runner plants. These results indicate that providing optimal condition for stock plants, rather than the runner plants, is more important for increasing the growth of the runner plants and that the efficiency of strawberry transplant production in a plant factory can be improved by decreasing light intensity or container volume for runner plants.

Fabrication of deflector integrated laser diodes and light deflection (광 편향기 집적 레이저 다이오드의 제작 및 광의 편향)

  • 김강호;권오기;김종회;김현수;심은덕;오광룡;김석원
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.2
    • /
    • pp.171-176
    • /
    • 2004
  • A light deflector integrated laser diode(LD) was fabricated and the characteristics of LD and ourput beam deflection as a function of deflector injection current were measured. To integrate the deflector with LD, a passive waveguide was integrated with the LD and a triangular-type light deflector was fabricated on the upper clad of the passive waveguide section. Light deflection from the fabricated light deflector is controlled by the effective refractive index variation induced by carrier injection. To characterize the effect of the deflector injection current, threshold current, slope efficiency, and output beam spectrum were measured as a function of deflector injection current. From these measured data, the increment in the threshold current and the decrement of the slope efficiency were observed. However, the output beam spectrum was not affected by the deflector. The Beam Propagation Method(BPM) was used to simulate the proposed device and the light deflection was measured by the far-field pattern of the output beam as a function of the deflector injection current. In the fabricated deflector integrated LD, the deflection angle of 1.9$^{\circ}$ at the injection current of 15 ㎃ was obtained.

Improvement in Light Extraction Efficiency of 380 nm UV-LED Using Nano-patterned n-type Gan Substrate (나노 구조의 패턴을 갖는 n-type GaN 기판을 이용한 380 nm UV-LED의 광 추출 효율 개선)

  • Baek, Kwang-Sun;Jo, Min-Sung;Lee, Young-Gon;Sadasivam, Karthikeyan Giri;Song, Young-Ho;Kim, Seung-Hwan;Kim, Jae-Kwan;Jeon, Seong-Ran;Lee, June-Key
    • Korean Journal of Materials Research
    • /
    • v.21 no.5
    • /
    • pp.273-276
    • /
    • 2011
  • Ultraviolet (UV) light emitting diodes (LEDs) were grown on a patterned n-type GaN substrate (PNS) with 200 nm silicon-di-oxide (SiO2) nano pattern diameter to improve the light output efficiency of the diodes. Wet etched self assembled indium tin oxide (ITO) nano clusters serve as a dry etching mask for converting the SiO2 layer grown on the n-GaN template into SiO2 nano patterns by inductively coupled plasma etching. PNS is obtained by n-GaN regrowth on the SiO2 nano patterns and UV-LEDs were fabricated using PNS as a template. Two UV-LEDs, a reference LED without PNS and a 200 nm PNS UV-LEDs were fabricated. Scanning Electron microscopy (SEM), Transmission Electron Microscopy (TEM), X-Ray Diffraction (XRD), Photoluminescence (PL) and Light output intensity- Input current- Voltage (L-I-V) characteristics were used to evaluate the ITO-$SiO_2$ nanopattern surface morphology, threading dislocation propagation, PNS crystalline property, PNS optical property and UVLED device performance respectively. The light out put intensity was enhanced by 1.6times@100mA for the LED grown on PNS compared to the reference LED with out PNS.

Spore Germination and Prothallium Development Conditions of Lygodium japonicum (Thunb.) Sw. (실고사리(Lygodium japonicum (Thunb.) Sw.) 포자발아와 전엽체 발달조건)

  • Kwon, Hyuk Joon;Shin, So Lim;Lim, Yun Kyung;Kim, Soo-Young
    • Korean Journal of Plant Resources
    • /
    • v.29 no.4
    • /
    • pp.400-406
    • /
    • 2016
  • This study was conducted to determine the optimal conditions of growth medium, temperature, and light quality for efficient propagation of Lygodium japonicum spores. The rate of spore germination and prothalium development was high in Knop and 1/8MS and 1/4MS media, which had low mineral content; in particular, the germination rate exceeded 74%, and the germinated spores developed into heart-shaped prothallia. However, in Knop‘s medium with the lowest mineral content, a rapid prothallium senescence was observed; in 1/4MS medium, prothallium development was delayed. Germination rate increased with the increase in temperature and reached its maximum, 86.7%, at 30℃; however, at this temperature, the prothallia were thinner and abnormal development of rhizoids was observed compared to normally developed prothallia and rhizoids at 25℃. Therefore, the results suggested that the optimal temperature for L. japonicum spore germination was 25℃. The rate of germination was also measured under different light conditions, and the highest rate of 90.6% was observed under LED red light compared to fluorescent (77.2%) or LED blue (5.4%) lights. The germinated spores developed into heart-shaped prothallia under LED red light; however, 15 days after seeding, prothallium development decreased and the became elongated. In contrast, a normal and continuous development of heart-shaped prothallia was observed under fluorescent light.

Analysis and Design of Surface Plasmon Waveguide

  • Kim, Min-Wook;Jung, Jae-Hoon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.8 no.3
    • /
    • pp.7-11
    • /
    • 2009
  • In this paper, we developed and presented a design result for optimizing the geometry of Ag circular SPP waveguide for subwavelength waveguide applications. We investigated the effect of the design parameters on the light propagation and find the optimum design for small modal size, high coupling coefficient, and low sensitivity. The results show that the globally optimal design locates optimal waveguide geometries more efficiently than individual optimal points for multivalued objective function.

  • PDF

The study on the culture of Lycoris radiata HERB in Medicinal Plant II. The Effect of Shade net on Growth and Bulb Yield (약용식물인 석산의 재배학적 연구 II. 광강도가 석산의 생육 및 인경수량에 미치는 영향)

  • 이종일
    • Korean Journal of Plant Resources
    • /
    • v.4 no.1
    • /
    • pp.23-27
    • /
    • 1991
  • This experiment was conducted to establish shade-method suited to on tile artificial propagation of Lycoris radiata HERB. The ligilt intensity in the native habitatwas 30 kux in March and 3.2 Klux from June to sept. The average light intensityin tile open area was 137 Klux in June. The plant height and number of Ieaves wasgood at the 35% to 55% shadeing net. Bloonling time of Lycoris radiata HERB was inthe last of Sept. Yeild of bulb was increased in 35% to 55% of shadeing net.

  • PDF

Invasive and non-invasive methods for estimating the optical properties of tissue at laser wavelengths (레이저 파장에서의 생체 침습적 및 비침습적 광학계수 측정 방법)

  • Yoon, Gil-Won
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.12
    • /
    • pp.147-150
    • /
    • 1994
  • To predict light propagation in biological tissues irradiated by laser, the optical properties such as absorption and scattering coefficients are required. There have been various techniques for measuring these coefficients. One method requires tissue samples, often a slab of thin tissue, is invasive. On the other hand, non-invasive method usually measures back-scattered light from a subject with no physical intervent ions. Advantages and disvantages of using different methods are investigated. A careful attention should be made in order to select the best method for a given experimental condition since, even either for invasive or non-invasive method, accuracy is subject to governing models and sample preparations.

  • PDF