• 제목/요약/키워드: Light filter

검색결과 603건 처리시간 0.022초

표면플라즈몬공명 가시화 장치를 이용한 증발하는 이종혼합물 액적의 실시간 농도 가시화 기법 개발 (Development of the Real-time Concentration Measurement Method for Evaporating Binary Mixture Droplet using Surface Plasmon Resonance Imaging)

  • 정찬호;이형주;최창경;이형순;이성혁
    • 한국분무공학회지
    • /
    • 제26권4호
    • /
    • pp.212-218
    • /
    • 2021
  • The present study aims to develop the Surface Plasmon Resonance (SPR) imaging system facilitating the real-time measurement of the concentration of evaporating binary mixture droplet (BMD). We introduce the theoretical background of the SPR imaging technique and its methodology for concentration measurement. The SPR imaging system established in the present study consists of a LED light source, a polarizer, a lens, and a band pass filter for the collimated light of a 589 nm wavelength, and a CCD camera. Based on the Fresnel multiple-layer reflection theory, SPR imaging can capture the change of refractive index of evaporating BMD. For example, the present study exhibits the visualization process of ethylene glycol (EG)-water (W) BMD and measures real-time concentration change. Since the water component is more volatile than the ethylene glycol component, the refractive index of EG-W BMD varies with its mixture composition during BMD evaporation. We successfully measured the ethylene glycol concentration within the evaporating BMD by using SPR imaging.

A Study on the Image Processing of Visual Sensor for Weld Seam Tracking in GMA Welding

  • Kim, J.-W.;Chung, K.-C.
    • International Journal of Korean Welding Society
    • /
    • 제1권2호
    • /
    • pp.23-29
    • /
    • 2001
  • In this study, a preview-sensing visual sensor system is constructed far weld seam tracking in GMA welding. The visual sensor system consists of a CCD camera, a diode laser system with a cylindrical lens, and a band-pass-filter to overcome the degrading of image due to spatters and/or arc light. Among the image processing methods, Hough transform method is compared with the central difference method from a viewpoint of the capability for extracting the accurate feature position. As a result, it was revealed that Hough transform method can more accurately extract the feature positions and it can be applied to real time weld seam tracking. Image processing which includes Hough transform method is carried out to extract straight lines that express laser stripe. After extracting the lines, weld joint position and edge points are determined by intersecting the lines. Even though the image includes a spatter trace on it, it is possible to recognize the position of weld joint. Weld seam tracking was precisely implemented with adopting Hough transform method, and it is possible to track the weld seam in the case of offset angle is in the region of $\pm$ $15^{\circ}$.

  • PDF

15×15 Kernel Block Adaptive Median Filter를 적용한 저속 카메라 통신용 LED 조명 검출 알고리즘 연구 (15×15 Kernel Block Adaptive Median Filter based on LED Illumination Detection Algorithm for Low Rate CamCom)

  • 한정도;이민우;차재상
    • 한국ITS학회 논문지
    • /
    • 제17권5호
    • /
    • pp.143-150
    • /
    • 2018
  • RF 기반 고속 무선통신 기술이 급속히 발전함에 따라 무선 주파수 대역을 기반으로한 IoT 네트워크용 디바이스가 빠르게 보급되고 있으나, 최근 IoT 네트워크 디바이스의 급속한 확산 속도에 비하여 RF 통신 기술의 발전속도가 미치지 못하고 있다. 이러한 상황에서 가시광원을 송신수단으로 사용하는 OWC 기술은 RF 기반 무선 통신의 대역 고갈 문제를 극복 할 수 있는 기술로서 주목받고 있으나, OWC용 데이터 수신 중 발생하는 LED 조명 형태의 왜곡으로 인하여 LED 조명 검출율이 저하되고 RoI의 설정이 부정확해지는 현상이 발생 할 가능성이 있다. 본 논문에서는 Adaptive Median Filter를 적용한 저속 카메라 통신용 LED 조명 검출 알고리즘을 제안하였다. 이를 통해 명확한 RoI 설정 및 LED 조명 검출이 가능할 것으로 사료되며, 본 연구결과를 통해 RF 기반 무선 통신기술의 보완재로서의 역할을 효율적으로 수행 할 수 있을 것으로 판단된다.

광 HDMI 인터페이스용 2채널 광송신기 광학 설계 (Optical Design of an Integrated Two-Channel Optical Transmitter for an HDMI interface)

  • 윤현재;강현서
    • 한국광학회지
    • /
    • 제26권5호
    • /
    • pp.269-274
    • /
    • 2015
  • 본 논문에서는 code V 시뮬레이터를 이용하여 광 HDMI 인터페이스에 적용하기 위한 집적형 2채널 TO 구조 광송신기의 광학계 설계를 하였다. 제안된 집적형 2채널 TO 구조 광송신기는 지름의 6.4 mm인 하나의 8 pin TO-CAN 패키지 안에 2개의 VCSEL을 평행하게 부착하고 그 위에 반구(hemisphere) 렌즈가 부착된 직육면체 모양($1mm(H){\times}2mm(W){\times}4mm(D)$)의 렌즈필터 블록 (lens filter block) 을 올려놓은 구조이다. 집적형 2채널 TO 구조 광송신기 제작 시 1060 nm/1270 nm와 1330 nm/1550 nm로 두 개 파장씩 묶어 TO-CAN 형태로 제작하므로, 이들 파장 조합에서 반구 렌즈의 지름은 0.6 mm, 볼 렌즈와 렌즈 필터 간격(L)은 파장 1060 nm/1270 nm 조합의 경우 1.7 mm, 파장 1330 nm/1550 nm 조합의 경우 2.0 mm일 때 최적의 결과를 얻을 수 있었다. 이때 렌즈필터 블록의 초점거리($f_0$)는 1060 nm, 1270 nm, 1330 nm, 1550 nm 파장에 대하여 0.351 mm, 0.354 mm, 0.355 mm, 0.359 mm이었으며 렌즈 필터 블록과 볼 렌즈를 통과한 빛의 초점 위치(F)는 파장 1060 nm/1270 nm 조합의 경우 0.62 mm, 파장 1330 nm/1550 nm 조합의 경우 0.60 mm ~ 0.66 mm이었다.

맥동 식쌍성 Y Cam의 ROCHE 모형과 절대 물리량 (ROCHE MODEL AND ABSOLUTE DIMENSIONS OF THE ECLIPSING BINARY Y CAM WITH A PULSATING COMPONENT)

  • 이재우;김천휘;김승리;윤재혁;권순길
    • Journal of Astronomy and Space Sciences
    • /
    • 제19권3호
    • /
    • pp.187-196
    • /
    • 2002
  • 2000년 11월부터 2001년 5월까지 총 16일간 맥동 식쌍성 Y Carn을 소백산천문대의 61cm 망원경에 부착된 단일 V 필터로 CCD 측광을 수행하였다. 새롭게 얻은 V 광도곡선과 Broglia & Marin(1974)의 BV 광도곡선을 Wilson-Devinney 방법의 Mode 2(분리형)와 Mode 5(준분리형)으로 분석하였다. 분석 결과는 다음과 같다. 1) 광도곡선 분석만으로는 분리헝과 준분리형의 Roche 모형 중 어느 것이 Y Cam의 진실한 Roche 모형인가를 가려낼 수가 없다. 2) Y Cam의 B광도곡선에는 삼체의 광도가 약 2%, V광도곡선에는 약 3% 존재한다. 3) Y Cam의 주성에서 발생하는 맥동에 의한 밝기 변화는 광도곡선 해에 거의 영향을 주지 않으나, 맥동을 고려하였을 경우 분리형 모델이 준분리형 모델보다 약간 더 관측치를 잘 맞춘다. 4) 분리형과 준분리형 각각에 대해 Y Cam의 절대물리량을 계산하였다.

볼로미터형 테라헤르츠 센서의 광학적 특성 연구 (Optical Characteristics of Bolometric Terahertz Sensor)

  • 한명수;송우섭;홍정택;이동희
    • 센서학회지
    • /
    • 제27권5호
    • /
    • pp.335-339
    • /
    • 2018
  • The optical characteristics of a terahertz (THz) antenna-coupled bolometer (ACB) detector were evaluated using a pulsed quantum cascade laser (QCL) and radiation blackbody sources. We investigated a method for measuring the responsivity and noise-equivalent power (NEP) of the THz detector using two different types of light sources. When using a QCL source with a frequency of 3 THz, the average responsivity of 24 devices was $1.44{\times}10^3V/W$ and the average NEP of those devices was $3.33{\times}10^{-9}W/{\surd}Hz$. The average responsivity and NEP as measured by blackbody source were $1.79{\times}10^5V/W$ and $6.51{\times}10^{-11}W/{\surd}Hz$, respectively, with the measured values varying depending on the light source. This was because the output power of each light source was different, with the laser source being driven by a pulse type wave and the blackbody source being driven by a continuous wave. The power input to the THz sensor was also different. Futhermore, the responsivity and NEP values measured using band pass filter (BPF) were similar to those measured when using only THz windows. It was found that ACB sensor responds normally in the THz region to both the laser and the blackbody source, and the method was confirmed to effectively evaluate the characteristics of the THz sensor.

휴대형 랩온어칩을 위한 집적화 광원으로의 OLED 적용 (Application of OLED as the Integrated Light source for the Portable Lab-On-a-Chip)

  • 김주환;신경식;김영민;김용국;양은경;김태송;강지윤;김상식;주병권
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 디스플레이 광소자분야
    • /
    • pp.193-197
    • /
    • 2004
  • The organic light emitting diode (OLED) is proposed as the novel source in the microchip because it has ideal merits (various wavelengths, thin-film structure and overall emitting) for the integration. In this paper, we fabricated the finger-type pin photodiodes for fluorescence detection and the advanced microchip with OLED integrated pn the microchannel. The finger-type in the diode design extended the depletion region and reduced the internal resistance about 31.2% than rectangular-type. The photodiodes had a 100pA leakage current and a 8720 sensitivity $(I_{Light}/I_{Dark})$ at -1 V bias. The interference filter with 32 layers ($SiO_2$, $TiO_2$) was directly deposited on the photodiode. The OLED was fabricated on the ITO coated glass and was bonded with LOC. The application of thin-film OLED increased the excitation efficiency and simplified the integration process extremely. The prototype device of this application had a superior sensitivity of 100nM-LOD in the fluorescence detection.

  • PDF

눈깜작임, 증감뇌유발전위와 성격의 상호관계 (Eyeblinks, EP Augmenting / Reducing and Personality)

  • 이성훈
    • 수면정신생리
    • /
    • 제1권2호
    • /
    • pp.156-162
    • /
    • 1994
  • 목 적 : 눈깜작임은 뇌에서 감각을 조절하는 기능과 관계된 개인의 인지능력과 성격에 따라 달라질 수 있다. 저자들은 이러한 성격이 눈깜작임과 증감뇌유발전위 등과 상호 어떠한 연관이 있는지를 연구하려고 하였다. 방법 : 44 명의 정상 대학생에게 증감뇌유발전위, 눈깜작임과 Zuckerman 의 감각추구척도와 Eysenck 성격설문지 동을 조사하여 그 상호관계를 분석하였다. 결 과 : 증감뇌유발전위에서 빛의 강도가 증가할수록 눈깜작임이 증가하였다. 대부분의 성격척도에서 눈깜작임과 유의한 역상관관계를 보였으며 신경증척도만이 정상관관계를 보였다. 눈깜작임과 증감유발전위의 기울기와 가장 강한 정상관관계를 보인 뇌의 부위는 우측 후 측두엽이었다. 결 론 : 감각추구경향이 강할수록 눈을 적게 깜작이었다. 유발전위보다 눈깜작임이 성격과 더 높은 상관관계를 보여 눈깜작임이 더 일차적인 필터 역할을 한다고 생각된다. 그리고 우측 후 측두엽은 여러 뇌 부위 중 시각을 조절하는데 가장 중요한 역할을 하는 것으로 유추된다.

  • PDF

Ka대역 위성통신용 fly-away 터미널 안테나 & RF 시스템 설계 (An Antenna & RF System for Fly-away Satcom Terminal Application on Ka-band)

  • 박병준;김춘원;윤원상;이성재
    • 한국군사과학기술학회지
    • /
    • 제17권4호
    • /
    • pp.485-491
    • /
    • 2014
  • An Antenna & RF system for a fly-away satcom terminal application on ka-band is presented in this paper. The Fly-away satellite terminal can be moved and operated by two person and adapt automatic satellite tracking system in order to decrease the tracking time. Additionally, for low-power consumption, compact size and light-weight, a dual reflector antenna is constructed using dual-offset gregorian antenna structure. For minimize weight, the reflector of the antenna is made of Magnesium. For low-power consumption and light-weight, the pHEMT MMIC compound devices is utilized. The Electronic Band-Gap(EBG) Low-Pass Filter(LPF) is designed for harmonic rejection. In the receiving part, Low-Noise Block converter(LNB) structure is designed for compact and lightweight. In this paper, fly-away satcom terminal with low-power consumption, compact size and light-weight is described with antenna system and RF system performances. Through the experimentation, fly-away terminal's EIRP is more than 50dBW, G/T is more than $17dB/^{\circ}K$.

Design of white tandem organic light-emitting diodes for full-color microdisplay with high current efficiency and high color gamut

  • Cho, Hyunsu;Joo, Chul Woong;Choi, Sukyung;Kang, Chan-mo;Kim, Gi Heon;Shin, Jin-Wook;Kwon, Byoung-Hwa;Lee, Hyunkoo;Byun, Chun-Won;Cho, Nam Sung
    • ETRI Journal
    • /
    • 제43권6호
    • /
    • pp.1093-1102
    • /
    • 2021
  • Microdisplays based on organic light-emitting diodes (OLEDs) have a small form factor, and this can be a great advantage when applied to augmented reality and virtual reality devices. In addition, a high-resolution microdisplay of 3000 ppi or more can be achieved when applying a white OLED structure and a color filter. However, low luminance is the weakness of an OLED-based microdisplay as compared with other microdisplay technologies. By applying a tandem structure consisting of two separate emission layers, the efficiency of the OLED device is increased, and higher luminance can be achieved. The efficiency and white spectrum of the OLED device are affected by the position of the emitting layer in the tandem structure and calculated via optical simulation. Each white OLED device with optimized efficiency is fabricated according to the position of the emitting layer, and red, green, and blue spectrum and efficiency are confirmed after passing through color filters. The optimized white OLED device with color filters reaches 97.8% of the National Television Standards Committee standard.