• Title/Summary/Keyword: Light curing composite resin

검색결과 186건 처리시간 0.03초

백악질 변연을 갖는 2급 와동에 충전된 4종 복합레진의 미세누출 (MICROLEAKAGE OF 4 DIFFERENT COMPOSITE RESIN RESTORATIONS IN CLASS II CAVITY WITH CEMENTAL MARGIN)

  • 조영곤;한세희;김은성
    • Restorative Dentistry and Endodontics
    • /
    • 제26권6호
    • /
    • pp.492-498
    • /
    • 2001
  • The purpose of this study was to evaluate four different composite resins in vitro for microleakage in Class II box type restorations that have gingival margins apical to the cementoenamel junction. Forty caries free extracted human molars were used in this study. The Class II cavities were prepared 1.0mm below cementoenamel junction with a #701 carbide bur. The teeth were randomly divided into four groups, each group comprising 20 treated cavities according to adhesives and filling materials ; Group 1: Scotchbond Multipurpose/Z 100. Group 2: Ariston Liner/Ariston pHc, Group 3: One Step/Pyramid, Group 4: Prime & Bond NT/SureFil. To simulate the clinical situation during restoration placement, a restoration template was fabricated and composite resin was filled using a three sited light-curing incremental technique. The specimens were stored in the 100% humidity for 7 days prior to thermocycling. The specimens were immersed in 2% methylene blue dye solution for 24 hours and then embeded in transparent acrylic resin and sectioned mesiodistally with a diamond wheel saw. The degree of marginal leakage was scored under the stereomicroscope($\times$20) and the data were analyzed by Kruskal Wallis test and Mann Whitney test. (omitted)

  • PDF

광중합 전후 복합레진의 광학적 특성 (Optical characteristics of resin composite before and after polymerization)

  • 엄아향;김덕수;이수희;변창원;박노훈;최경규
    • Restorative Dentistry and Endodontics
    • /
    • 제36권3호
    • /
    • pp.219-230
    • /
    • 2011
  • 연구목적: 복합레진의 광중합 전후에 일어나는 색과 투명도 변화를 측정하고, CQ의 함량을 정량하였으며, 광중합 전후 복합 레진의 굴절률을 측정해 이들의 상관 관계를 알아보고자 하였다. 연구 재료 및 방법: Esthet-X, Filtek supreme, Gradia Direct, Clearfil Majesty, Beautifil II에 대하여 Colorimeter NF999를 이용하여 광중합 전후의 색과 투명도를 각각 측정하고, GC-MS를 이용해 각 복합레진의 CQ 함량을 측정하였으며, spectroscopic ellipsometer를 이용해 광중합 전후의 굴절률을 측정하였다. 결과: 투명도는 광중합 후에 증가하였고, body shade에서 opaque shade보다 투명도 차이가 크게 나타났다. 모든 레진에서 body shade의 CQ 함량이 opaque shade의 CQ 함량보다 높았다. 굴절률은 광중합 후에 모든 레진에서 증가하였으며, body shade와 opaque shade간에 굴절률의 변화는 유의한 차이가 있었다. 결론: 광중합 후에는 복합레진의 색과 투명도가 상당한 차이를 나타낸다. 따라서 임상에서 direct shade matching을 시행할 때는 중합된 레진을 사용하여야 한다.

광중합기의 광원에 따른 브라켓 전단결합강도 비교 (Comparison of the shear bond strength of brackets in regards to the light curing source)

  • 차정열;이기준;박선형;김태원;유형석
    • 대한치과교정학회지
    • /
    • 제36권3호
    • /
    • pp.198-206
    • /
    • 2006
  • 제논 플라즈마 아크 광중합기나 LED 광중합기가 치과영역에 소개된 이후로 기존의 텅스텐 할로겐 광중합기를 사용할 때에 비해 교정장치의 부착시간이 현저하게 줄어들 수 있게 되었다. 제논 플라즈마 아크 광중합기에 대한 중합시간과 전단강도에 대해서는 여러 연구가 있어왔던 반면, LED 광중합기를 이용하여 교정용장치의 부착을 위한 중합시간에 대한 연구는 미진하다. 본 연구의 목적은 LED 광중합기의 중합시간에 따른 결합강도를 플라즈마 아크 광중합기와 비교하여 적절한 브라켓의 부착강도를 얻기 위해 요구되는 중합시간을 알아보는데 있다. 120개의 발치된 사람의 소구치에 컴포짓 레진으로 브라켓을 부착시킨 후 4초, 6초, 8초 동안 플라즈마 아크 광원과 LED 광원으로 각각 중합시켰다. 그 후 결합강도를 만능시험기(Universal Testing Machine)로 계측한 결과, 플라즈마 아크 광중합기에서는 4초 이상에서, LED 광중합기에서는 8초 이상의 중합시간에서 기존의 할로겐 광원을 40초간 노출시켰을 때와 비슷한 전단결합강도를 나타내었다. 플라즈마 아크 광중합기와 LED 광중합기의 중합시간이 접착제 잔류지수 (adhesive remnant index) 수치에 대해 영향을 미치지 않았다.

Effect of silane activation on shear bond strength of fiber-reinforced composite post to resin cement

  • Kim, Hyun-Dong;Lee, Joo-Hee;Ahn, Kang-Min;Kim, Hee-Sun;Cha, Hyun-Suk
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권2호
    • /
    • pp.104-109
    • /
    • 2013
  • PURPOSE. Among the surface treatment methods suggested to enhance the adhesion of resin cement to fiberreinforced composite posts, conflicting results have been obtained with silanization. In this study, the effects of silanization, heat activation after silanization, on the bond strength between fiber-reinforced composite post and resin cement were determined. MATERIALS AND METHODS. Six groups (n=7) were established to evaluate two types of fiber post (FRC Postec Plus, D.T. Light Post) and three surface treatments (no treatment; air drying; drying at $38^{\circ}C$). Every specimen were bonded with dual-curing resin cement (Variolink N) and stored in distilled water for 24 hours at $37^{\circ}C$. Shear-bond strength (MPa) between the fiber post and the resin cement were measured using universal testing device. The data were analyzed with 1-way ANOVA and by multiple comparisons according to Tukey's HSD (${\alpha}$=0.05). The effect of surface treatment, fiber post type, and the interactions between these two factors were analyzed using 2-way ANOVA and independent sample T-tests. RESULTS. Silanization of the FRC Postec Plus significantly increased bond strength compared with the respective non-treated control, whereas no effect was determined for the D.T. Light Post. Heat drying the silane coupling agent on to the fiberreinforced post did not significantly improve bond strength compared to air-syringe drying. CONCLUSION. The bond strength between the fiber-reinforced post and the resin cement was significantly increased with silanization in regards to the FRC Postec Plus post. Bond strength was not significantly improved by heat activation of the silane coupling agent.

다양한 파장폭의 가시광선에 의해 중합된 복합레진의 미세경도와 변연누출도 (MICROHARDNESS AND MICROLEAKAGE OF COMPOSITE RESIN CURED BY VISIBLE LIGHT WITH VARIOUS BAND OF WAVELENGTH)

  • 박수만;이재용;한승렬;하상윤;신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제27권4호
    • /
    • pp.403-410
    • /
    • 2002
  • Several ways of curing are being tried to improve material's properties and reduce marginal gap. However, all are considering about the pattern of light intensity. It was noted from the preliminary study the change of light wavelength from filter changing may give an impact on material's property and microleakage. The object of this study was to verify the effect of filters with various wavelength width on the microhardness and microleakage of composite resin ; hybrid type of DenFil and submicron hybrid type of Esthet X. Composite resins were cured using 3 kinds of filter; narrow-banded(465-475 nm), mid-banded(430-470 nm), wide-banded(400-500 nm). After the estimation of microhardness. degree of dye penetration and the maximum gap from SEM evaluation were done between 4 groups that showed no difference in microhardness value of the lower surface . The results were as follows : 1 Adequate microhardness could not be gained with a narrow-banded filter irrespective of curing time. At the upper surface, DenFil should be polymerized with middle or wide-banded filter for 20 seconds at least, while Esthet X be col$.$ed with middle or wide-banded filter for 30 seconds at least to get simitar hardness value to control group. 2. There was little dye penetration in enamel margin, but all dentin margins skewed much more dye penetration irrespective of curing conditions. Although there was no statistical difference, groups cured with mid-banded filter for 40 seconds and with wide-width filter for 20 seconds showed relatively less dye penetration. 3. It was revealed from the SEM examination that group cured with wide-banded filter had the smallest gap without statistical significance. Spearman's rho test showed that the correlation between the results of dye penetration and SEM examination was very low. From these results, it could be concluded that curing with wide-width filter would be better than the other techniques, even though the curing technique using mid-width filter seems to have its own unique advantage.

광중합기 종류에 따른 복합레진과 콤포머의 미세누출에 관한 연구 (MARGINAL LEAKAGE OF COMPOSITE RESIN AND COMPOMER RESTORATIONS CURED WITH THREE DIFFERENT LIGHT SOURCES)

  • 박창후;양규호;김선미;최남기
    • 대한소아치과학회지
    • /
    • 제33권3호
    • /
    • pp.438-446
    • /
    • 2006
  • 광중합 수복재의 중합시 발생되는 틈을 최소화하기 위해 최근 여러 가지 광중합기와 중합방법이 개발되고 있는데, 할로겐 광과 플라즈마광, LED광으로 광조사를 했을 때 미세누출을 비교하는 실험을 통해 임상에 적용해보고자 한다. 치아의 협설면에 5급와동을 형성하고, 광중합레진을 수복하여 광중합한 뒤 24시간 후 2% 메틸렌블루 용액에 담근 다음 치아를 협설로 절단하여 미세누출도를 평가하였다. 통계처리는 Kruskal-Wallis test와 Man-Whitney test를 사용하여 각 군의 유의성을 검정하였다. 법랑질에서 Dyract AP로 충전한 경우 광원에 따른 미세누출의 차이는 없었으나, $Z250^{(R)}$으로 충전한 경우에서는 $Flipo^{(R)}$가 FreeLight $2^{(R)}$혹은 $TriLight^{(R)}$보다 미세누출이 컸다. 충전재에 따른 법랑질 변연에서의 미세누출을 측정한 결과 LED광 혹은 할로겐 광중합시 복합레진이 컴포머에 비해 작은 미세누출을 보였으나, $Flipo^{(R)}$에서는 두 재료간의 차이가 없었다. 상아질변에서는 $Flipo^{(R)}$와 FreeLight $2^{(R)}$로 중합시 $Z250^{(R)}$이 Dyract AP보다 미세누출이 작았으나, $TriLight^{(R)}$에서는 두 재료간의 차이가 없었다. 이번 연구에서 $Z250^{(R)}$이 Dyract AP보다는 미세누출이 작았으며, $Z250^{(R)}$으로 충전한 경우 에나멜변연에서 $Flipo^{(R)}$가 FreeLight $2^{(R)}$$TriLight^{(R)}$보다 미세누출이 크다는 것을 알 수 있었다.

  • PDF

복합레진의 exponential 중합법이 상아질접착제의 미세인장접착강도에 미치는 영향 (EFFECT OF THE EXPONENTIAL CURING OF COMPOSITE RESIN ON THE MICROTENSILE DENTIN BOND STRENGTH OF ADHESIVES)

  • 성소래;서덕규;이인복;손호현;조병훈
    • Restorative Dentistry and Endodontics
    • /
    • 제35권2호
    • /
    • pp.125-133
    • /
    • 2010
  • 접착제를 통해 치아에 접착되는 상부의 복합레진의 빠른 중합은 접착제층에 높은 중합수축응력을 발생시킨다. 중합수축응력을 경감시키기 위해서, LED 광중합기의 하나인 Elipar FreeLight 2 (3M ESPE, USA)에서는 최초 5초 이내에 광강도를 증가시키는 exponential 중합법을 채택하고 있다. 본 연구에서는 짧은 시간내에 광강도를 증가시키는 exponential 중합법이 복합레진의 초기 중합수축속도를 효과적으로 조절할 수 있는지를 알아보기 위해 접착제 적용 후 상부의 복합레진을 exponential 중합법과 continuous 중합법으로 중합하여 상아질접착제의 미세인장접착강도를 비교하였다. 3M사의 Scotchbond Multipurpose Plus (MP), Single Bond 2 (SB), 및 Adper Prompt (AP)의 세 종류의 접착제를 발치한 대구치의 교합면 상아질에 제조사의 지시에 따라 적용하고, 혼합형 복합레진인 Denfil (Vericom, Korea)을 두 가지광중합방법으로 중합하였다. 접착 후 48시간에 미세인장접착강도를 측정하고, 파절면은 FE-SEM.으로 관찰하였다. 그 결과, 각각의 접착제에서 중합방법에 따른 접착강도의 차이는 관찰할 수 없었다(Two-way ANOVA, p > 0.05). MP와 SB의 미세인장접착강도는 AP에 비해 유의하게 높았다(p < 0.05). 대부분의 파절시편에서는 혼합형 파절이 가장 많이 관찰되었으나, 중합방법에 따른 파절양상의 차이는 없었다. 결론적으로 5초 이내의 짧은 시간에 광강도를 증가시키는 exponential 중합법은 continuous 중합법과 비교하여 상아질접착제의 미세인장접착강도에 영향을 주지 않았다.

광중합형 복합레진의 중합 전, 후의 색 성분이 중합률과 굴곡강도에 미치는 영향 (Effects of the color components of light-cured composite resin before and after polymerization on degree of conversion and flexural strength)

  • 유지아;조병훈
    • Restorative Dentistry and Endodontics
    • /
    • 제36권4호
    • /
    • pp.324-335
    • /
    • 2011
  • 연구목적: 복합레진의 색조를 색 성분요소인 CIE $Lab^*$ 각 성분요소로 측정하고, 동일 시편에 대해서 중합률과 2축 굴곡강도(biaxial flexural strength)를 측정하여 이들의 상관관계를 비교함으로써 복합레진의 중합전, 후의 색 성분요소가 중합률과 물성에 미치는 영향을 알아보고자 하였다. 연구 재료 및 방법: 두 종류의 복합레진 Premisa (Kerr Co.)와 Denfil (Vericom Co)의 법랑질 색조(A1, A2, A3, A4)와 상아질 색조(A2O, A3O)에 대해 원판형의 시편을 제작하여 색성분, 중합률 및 2축 굴곡강도를 측정하였다. 분광광도계를 이용하여 중합 전, 후 및 7일에 CIE $L^*,\;a^*,\;b^*$ 값을 측정하고, 같은 시편에 대해 근적외선분광기를 이용하여 중합 후 2시간과 7일에 중합률을 측정하였다. 중합 7일 후에 색 성분과 중합률을 측정한 후 만능시험기에서 2축 굴곡강도를 측정하였다. 색요소인 CIE $L^*,\;a^*,\;b^*$ 각각의 값과 중합률, 및 2축 굴곡강도의 상관관계를 분석하였다. 결과: 두 종의 광중합형 복합레진은 중합 전과 후에 색 성분요소, 즉 색조의 변화가 있었고, 광중합 후에도 시간이 경과하면서 중합률이 증가되었다. 중합률은 제품, 기간, 및 색조의 영향을 받고(3-way ANOVA, p < 0.05), 굴곡강도는 제품 및 색조의 영향을 받았다(2-way ANOVA, p < 0.05). 중합률은 Premisa 한 제품에서만 중합 전, 후의 CIE $a^*$ component와 유의한 상관관계를 보였고, 굴곡강도도 Premisa에서 CIE $a^*$ 및 CIE $b^*$ component와 음의 상관관계를 보였다(Pearson product moment correlation, p < 0.05). 결론: 광중합 복합레진의 중합률과 굴곡강도는 제품의 중합 전,후의 색 성분에 의해 영향을 받았다.

표백술에 의한 복합 레진의 색변화와 색소 침착 정도 (DEGREE OF COLOR CHANGE AND DYE DEPOSITION ONTO COMPOSITE RESINS AFTER OFFICE BLEACHING IN VITRO)

  • 최낙원;손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제25권4호
    • /
    • pp.599-605
    • /
    • 2000
  • Among the effects of tooth bleaching on composite resins, degree of color change and dye deposition onto composite resins after office bleaching were investigated in vitro. Seventy two disc-shaped resin samples were fabricated with hybrid type composite resin, Z-100 under 3 different environments(24 samples for each environment) characterized by 3 kinds of light-curing intensity and duration($250mW/cm^2$-20sec., $250mW/cm^2$-40sec., $550mW/cm^2$-20sec.). As control, one-third samples of each group were not treated with bleaching agent. The remaining two-thirds samples of each group were treated with bleaching agent(bleaching group). Then, before thermocycling procedure in coffee bath, the half of the samples treated with bleaching agent were polished(polishing group) with polishing system. SofLex, but the other half(not-polishing group) and control group were not polished. Another 72 samples were also made with microfilled type composite resin. Sillux Plus and treated according to the experimental procedures mentioned above. The color of each resin sample was measured before bleaching, after bleaching, and after thermocycling preceded by bleaching. And color difference was evaluated. It was concluded as follows: 1. The amount of color change of resin samples after office bleaching was not statistically significant(p>0.05). But the samples which were treated with bleaching agent showed more color change than that of control group. 2. After thermocycling in coffee bath, the amount of color change of resin samples between control and bleaching group was not statistically significant(p>0.05). 3. After thermocycling in coffee bath, the polishing procedure of resin samples showed no statistically significant difference(p>0.05) between polishing and not-polishing group in the aspect of color change.

  • PDF

스트레인 게이지법을 이용한 복합레진과 컴포머의 중합수축 평가에 관한 연구 (A STUDY ON THE EVALUATION OF POLYMERIZATION SHRINKAGE OF COMPOSITE AND COMPOMER USING STRAIN GAUGE METHOD)

  • 김윤철;김종수;권순원;김용기
    • 대한소아치과학회지
    • /
    • 제29권1호
    • /
    • pp.19-29
    • /
    • 2002
  • 본 연구의 목적은 다양한 중합과정에 따른 복합레진과 컴포머의 수축 양상을 스트레인 게이지법(strain gauge method)을 이용하여 평가해보고자 하는 것이었다. 광중합기는 기존의 할로겐 시스템인 XL 3000(3M, USA)과 최근 소개된 plasma arc curing 시스템인 Flipo(LOKKI, France)를 사용하였고, 충전 재료는 복합레진인 Z-100(3M, USA)과 컴포머인 Dyract AP(Dentsply, Germany)를 사용하였다. 주형과 치아 와동 내에 충전된 실험재료의 중합수축을 각각 측정하였으며, 만능시험기를 이용하여 압축강도를 측정하였다. 중합수축 측정 결과 모두 중합초기에는 일시적인 재료의 팽창을 나타냈고, 그 후 약 1분간은 수축량이 급격히 증가하다가 증가의 폭이 점차 감소하는 양상을 보였다. 전반적으로 컴포머를 사용한 군에 비해 복합레진을 사용한 군에서 중합수축이 크게 나타났으며 plasma arc curing 시스템을 사용한 군에 비해 기존의 광조사 시스템 군에서 더 큰 중합수축을 보였다. 압축 강도의 측정결과는 컴포머 군에 비해 복합레진 군에서 크게 나타났다. 이상의 결과를 종합해 볼 때, plasma arc curing unit와 컴포머의 사용은 시술시간의 단축과 항우식 효과를 감안한다면 소아치과 영역에서의 사용이 긍정적으로 고려될 수 있다고 생각된다.

  • PDF