• Title/Summary/Keyword: Light Wall

Search Result 623, Processing Time 0.029 seconds

Hysteretic performance of a novel composite wall panel consisted of a light-steel frame and aerated concrete blocks

  • Wang, Xiaoping;Li, Fan;Wan, Liangdong;Li, Tao
    • Steel and Composite Structures
    • /
    • v.41 no.6
    • /
    • pp.861-871
    • /
    • 2021
  • This study aims at investigating the hysteretic performance of a novel composite wall panel fabricated by infilling aerated concrete blocks into a novel light-steel frame used for low-rise residential buildings. The novel light-steel frame is consisted of two thin-wall rectangular hollow section columns and a truss-beam assembled using patented U-shape connectors. Two bare light-steel frames and two composite wall panels have been tested to failure under horizontal cyclic loading. Hysteretic curves, lateral resistance and stiffness of four specimens have been investigated and analyzed. Based on the testing results, it is found that the masonry infill can significantly increase the lateral resistance and stiffness of the novel light-steel frame, about 2.3~3 and 21.2~31.5 times, respectively. Failure mode of the light-steel frame is local yielding of the column. For the composite wall panel, firstly, masonry infill is crushed, subsequently, local yielding may occur at the column if loading continues. Hysteretic curve of the composite wall panel obtained is not plump, implying a poor energy dissipation capacity. However, the light-steel frame of the composite wall panel can dissipate more energy after the masonry infill is crushed. Therefore, the composite wall panel has a much higher energy dissipation capacity compared to the bare light-steel frame.

A study of light output characteristics with various refractive indices and geometrical structures of the GaN based light-emitting device encapsulants (질화갈륨계 발광소자 봉지재의 굴절률 및 곡률 변화에 따른 광 출력 특성 연구)

  • Kim, Heyong-Jin;Yoo, Jin-Yeol;Kang, Young-Rae;Kim, Jae-Pil;Kwak, Joon-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.7
    • /
    • pp.1-8
    • /
    • 2012
  • In this paper, we improved the light extraction efficiency by structural change of LEDs on conventional LEDs. We simulated the LEDs light emission as functions of LED side wall angle, various refractive indices the geometrical structures and analyzed the condition improved the light efficiency. We present the results of experimerns and simulations for light output power from LEDs for various refractive indices and the geometrical structures of the LED encapsulants. When the side wall angle range was from 40[$^{\circ}$] to 30[$^{\circ}$], the LED emission increased. LED side wall angle onto LED using the simulation system with a fine tuning of the structure of the LEDs side wall angle is fabricated. Additionally, we changed the side wall angle of LED package with spherical structure and flat structure. The result of spherical structure ray tracting is higher compared with flat structure about 14[%].

A Study on The Color Examination and Color Planning in the Different Type of Classroom (학교 교실의 용도별 색채분포 및 색채계획에 관한 연구)

  • 김은정;김기환
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2003.05a
    • /
    • pp.65-68
    • /
    • 2003
  • The purpose of this study is examine the color planning in the different type of classroom to establish interior color planning. This study also uses environmental planning and practical use of basic data for color planning to future school facilities. The summary of this study is as followed. The primary school and middle school classrooms as well as the open space classrooms floor color recommended of brown and the primary school wall color is light yellow, middle school wall color is light yellow and brown. The high school classroom color is recommended brown and wall color to light yellow and green system. The recommended floor color of primary school which includes in computer room and language study room, library of the multi-purpose of media room recommended are gray, brown and pink. The recommended wall color in primary school is light gray. The middle school floor color propose gray and light brown and wall recommended color is light brown, gray, ivory with the high school the computer room, language study room and library. The floor color is recommended gray, green and the wall propose blue. Moreover, recognize that importance of color effectiveness in school interior facilities considering with Interior covering material in class room.

  • PDF

A study of Illumination on Exhibitory Space by Natural Light Through the Inducing Space (자연채광 유도공간에의한 전시공간내 채광에 관한 연구)

  • Hwang, Kyu-Seon;Tae, Won-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.1
    • /
    • pp.48-55
    • /
    • 2012
  • In recent years, it clearly shows the tendency toward the utilization of daylight in many exhibitory buildings such as museum since the expectation of visitors for whom high illuminance levels are preferable to perceive the details of the works of art. Shading devices and special glazings are often used as the tool to control the amount of light and heat which should be avoided for the presentation of high-light sensitive art works such as paintings. Another way of controling the light is to provide the space for inducing and attenuating light in the exhibitory building. This study aims to investigate the illuminance on the exhibitory space when the space for inducing and attenuating light is applied. Interaction between the daylight and the space was simulated by Lumen Micro program with variation of the size of the exhibitory space, the length of inner wall, surface reflectivity, area of windows to obtain the illumination of the wall surface. This study shows that those variables affect the illumination on the wall surfaces. By comparing the results with suggestive illumination of KS and ICOM, available wall for display on natural lighting are suggested for the seasons and time.

Bond Strength of Light-weight Inorganic Ceramic Board for Fire Resistant Curtain-wall System (커튼월 층간 화재확산방지구조 적용을 위한 경량무기발포 세라믹보드의 부착강도)

  • Shin, Hyeon-Uk;Song, Hun;Chu, Yong-Sik;Lee, Jong-Kyu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.214-215
    • /
    • 2014
  • Technologies on energy saving and materials used in curtain walls have progressed with increase of high-rise and large buildings. This study is explain fire resistance performance of the curtain walls. And focused on bond strength of light-weight inorganic ceramic board in high temperature for fire resistant curtain-wall system. From the result, curtain-wall system high fire resistant using the light-weight inorganic ceramic board.

  • PDF

Thermal Resistance and Condensation in the Light-frame Timber Wall Structures with Various Composition of Insulation Layers

  • Jang, Sang Sik;Lee, Hyoung Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.47 no.4
    • /
    • pp.533-542
    • /
    • 2019
  • As energy costs increase, more people has become interested on energy efficiency and savings in residential buildings. The two main subjects related to energy in residential buildings are insulation and condensation. There are two approaches to prevent condensation; increasing air tightness and maintaining the temperature inside of the wall structure over the dew point, which is in turn related to insulation. Even though the Korean government has highlighted the importance of energy efficiency for residential housings, and in spite of the customers' demands, the timber construction industry is still using conventional light-frame construction without even trying to improve energy efficiency. In this study, various types and combinations of wall structures were tested under cold outdoor and warm indoor temperatures to analyse the temperature gradients and to determine the possible sites of condensation in the wall structures. In addition to the experimental tests, three theoretical models were developed and their estimations of temperature change through the wall structure were compared with the actual measurements to evaluate accuracy of the models. The results of the three models agree relatively well with the experimental values, indicating that they can be used to estimate temperature changes in wall structures. The theoretical analysis of different insulation layers' combinations show that condensation may occur within the mid-layer in the conventional light-frame wall structures for any combination of inner-, mid-, and outer-layers of insulation. Therefore, it can be concluded that the addition of an inner and outer insulation layer or increasing the thickness of insulation may not be adequate to prevent condensation in the wall structure without preventing penetration of warm moist air into the wall structure.

A Study on the Development of Lightweight Wall for Sound Transmission Loss and Field Test Results of the Dry-Wall System (차음성능이 향상된 경량벽체 개발 및 성능평가 연구)

  • 이병권;배상환;홍천화
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.699-704
    • /
    • 2004
  • As being inconvenient to apply reinforced concrete structure to high-rise buildings, it is applied steel structured system. Therefore light-weight wall systems are applied as partition wall to reduce the self-load of the building. But, the required performances of a light-weight wall are not evaluated systematically. As a field survey result, partition walls of house-to-house were not showed their respected performances, so the dwellers are feel so worse the quality of the whole building. In steel-structured high-rise buildings especially, occupant's dissatisfaction concerned indoor noise was high because curtain wall systems having a high air-tight performance isolate the outdoor noise making masking effect. Therefore wall systems which have high performances of sound insulation and air-tightness are required in high-rise buildings. As a result, a new drywall system was presented and the performance was verified with field test.

  • PDF

Hygroscopic Properties of Light-Frame Wall with Different Assemblies

  • Kim, Se-Jong;Park, Chun-Young;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.34 no.2
    • /
    • pp.22-29
    • /
    • 2006
  • On purpose to reduce accumulated moisture and to prevent moisture condensation in a light-frame wall, thermal characteristics and moisture behaviors were investigated for four different wall assemblies; a) typical wall, b) addition of vapor retarder between the insulation and the gypsum board, c) addition of air gap for natural ventilation behind the siding, d) composition with b) and c). Each wall was tested under two climate conditions; 1) $20^{\circ}C$, 50% RH (indoor) and $30^{\circ}C$, 85% RH (outdoor), 2) $30^{\circ}C$, 85% RH (indoor) and $20^{\circ}C$, 50% RH (outdoor).The results showed that the typical wall assembly had poor resistance against moisture intrusion from the inside of building. Outdoor and indoor humidity caused the moisture condensations on the inside of the siding and the back surface of the sheathing respectively. The addition of a vapor retarder did not give significant improvement in preventing the moisture intrusion.

An Evaluation on the Sound Insulation Performance of Drywall for High-Rise Buildings (초고층 건물에 적용 가능한 건식벽체의 차음성능 평가)

  • Lee, Sang-Woo;Yoo, Ho-Chun;Lee, Su-Yeal;Jung, Gap-Chul;Jung, Young-Min
    • KIEAE Journal
    • /
    • v.7 no.2
    • /
    • pp.3-8
    • /
    • 2007
  • Recently, the structural system of public residential buildings has been changed from the reinforced concrete (RC) wall system to the (PC) wall and moment resisting systems. Thus, it is important to develop the suitable wall system in accordance with the trend of the modern structural system. This paper presents the basic study on the suitable boundary wall in high-rise buildings. The research also demonstrates the evaluation results on sound characteristics in the aspect of sound insulation. The evaluation of sound insulation capability for the commercialized wall structure was conducted based on literature survey while the measurement of sound insulation capability for the light-weght EPP concrete was performed in according to KS F2808 in laboratory. The main objective of this research is to propose the most suitable dry wall system as a sound insulation structure through the comparison and analysis of frequency characteristics and weight-acoustic attenuation.

Improvement of Sound Insulation at Low Frequencies Using Resilient Channel (탄성채널을 이용한 석고보드 건식벽체의 저주파 대역 차음성능 개선)

  • Kim, Kyung Ho;Jeon, Jin Yong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.27 no.1
    • /
    • pp.94-99
    • /
    • 2017
  • Breaking the rigid connection between the two faces of the wall can significantly improve the sound transmission loss of the wall. This is usually achieved by resiliently mounting the gypsum board on one of the two faces of the wall using resilient channel. Resilient channel with less stiffness than that of air cavity could move the resonance frequency of the light-weight wall. So we can get higher sound transmission loss at low frequencies for light-weight wall using resilient channel. It's sound transmission loss is 17 dB higher than that of single stud wall, and 5 dB higher than that of double stud wall.