• Title/Summary/Keyword: Light Therapy

Search Result 517, Processing Time 0.028 seconds

Study of a Brain Tumor and Blood Vessel Detection System Using Multiple Fluorescence Imaging by a Surgical Microscope (수술현미경에서의 다중형광영상을 이용한 뇌종양과 혈관영상 검출 시스템 연구)

  • Lee, Hyun Min;Kim, Hong Rae;Yoon, Woong Bae;Kim, Young Jae;Kim, Kwang Gi;Kim, Seok Ki;Yoo, Heon;Lee, Seung Hoon;Shin, Min Sun;Kwon, Ki Chul
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.1
    • /
    • pp.23-29
    • /
    • 2015
  • In this paper, we propose a microscope system for detecting both a tumor and blood vessels in brain tumor surgery as fluorescence images by using multiple light sources and a beam-splitter module. The proposed method displays fluorescent images of the tumor and blood vessels on the same display device and also provides accurate information about them to the operator. To acquire a fluorescence image, we utilized 5-ALA (5-aminolevulinic acid) for the tumor and ICG (Indocyanine green) for blood vessels, and we used a beam-splitter module combined with a microscope for simultaneous detection of both. The beam-splitter module showed the best performance at 600 nm for 5-ALA and above 800 nm for ICG. The beam-splitter is flexible to enable diverse objective setups and designed to mount a filter easily, so beam-splitter and filter can be changed as needed, and other fluorescent dyes besides 5-ALA and ICG are available. The fluorescent images of the tumor and the blood vessels can be displayed on the same monitor through the beam-splitter module with a CCD camera. For ICG, a CCD that can detect the near-infrared region is needed. This system provides the acquired fluorescent image to an operator in real time, matching it to the original image through a similarity transform.

Preparation and characterization of Poly(2-methacryloyloxyethyl phosphorylcholine/fluorescein O-methacrylate)-coated iron oxide nanoparticles (Poly(2-methacryloyloxyethyl phosphorylcholine/fluorescein O-methacrylate)가 도입된 산화철 나노 입자의 제조 및 발열 특성 연구)

  • Ryu, Sunggon;Cheong, In Woo
    • Journal of Adhesion and Interface
    • /
    • v.19 no.3
    • /
    • pp.106-112
    • /
    • 2018
  • Recently, the hyperthermia treatment of malignant tissues has gained great attention as a biocompatible and benign method that facilitates successful cancer therapy compared to radiation and chemotherapy. In this study, superparamagnetic ($Fe_3O_4$) iron oxide nanoparticles (IONP) coated with biocompatible polymer (IONP@P(MPC/FOM)) for the purpose of hyperthermia treatment were prepared and related characterization were performed. IONPs with having 15 nm diameter were first prepared by coprecipitation and followed by surface modification with 4-cyanopentanoic acid dithiobenzoate (CTP) for reversible addition-fragmentation chain transfer (RAFT) copolymerization by using 2-methacryloyloxyethyl phosphorylcholine (MPC) and fluorescein O-methacrylate (FOM) to form corona layer of P(MPC/FOM) on the surface of the IONP. Transmission electron microscopy (TEM) and dynamic light scattering (DLS) confirmed the morphology and hydrodynamic size of the IONP@P(MPC/FOM) and thermogravimetric analysis (TGA) confirmed the formation of P(MPC/FOM) corona layer, respectively. Exposing IONP dispersion to alternating magnetic field suggests that the IONP@P(MPC/FOM) aqueous dispersion with 0.2 wt.% can be used for hyperthermia treatment.

Angiogenic Effect of Cardiac Ankyrin Repeat Protein Overexpression in Vascular Endo-thelial Cell (Cardiac Ankyrin Repeat Protein의 과량발현이 혈관내피세포에서 갖는 혈관신생 촉진 효과)

  • Kong, Hoon-Young;Byun, Jong-Hoe
    • Korean Journal of Microbiology
    • /
    • v.44 no.4
    • /
    • pp.282-288
    • /
    • 2008
  • Tissue ischemia resulting from the constriction or obstruction of blood vessels leads to an illness that may affect many organs including the heart, brain, and legs. In recent years, considerable progress has been made in the field of therapeutic angiogenesis and the new approaches are expected to cure those "no-option patients" who are unsuited to conventional therapies. Although single angiogenic growth factor may be successful in inducing angiogenesis, combination of multiple growth factors is increasingly sought these days to augment the therapeutic responses. This trend is proper in light of the fact that blood vessel formation is a complex and multi-step process that requires the actions of many different factors. To meet the growing need for functionally significant blood flow recovery in the ischemic tissues, a novel strategy that can provide concerted actions of multiple factors is required. One way to achieve such a goal is to use a transcription factor that can orchestrate the expression of multiple target genes in the ischemic region and thus induce significant level of angiogenesis. Here, a putative transcription factor, cardiac ankyrin repeat protein (CARP), was evaluated in adenoviral vector context for angiogenic activity in human umbilical vein endothelial cells. The results indicated significant increase in proliferation, capillary-like structure formation, and induction of vascular endothelial growth factor, a typical angiogenic gene. Taken together, these results suggest that CARP represents itself as a novel target for therapeutic angiogenesis and warrants further investigation.

Effects of Patriniae Radix Extract on The Membranous Nephropathy Induced by Cationic Bovine Serum Albumin in Mice (패장초(敗醬草)가 Cationic Bovine Serum Albumin 투여로 유발된 Membranous Nephropathy Mouse Model에 미치는 영향)

  • Chang, Sun-Kyu;Cho, Chung-Sik;Kim, Cheol-Jung
    • The Journal of Internal Korean Medicine
    • /
    • v.30 no.1
    • /
    • pp.212-227
    • /
    • 2009
  • Objective : Membranous nephropathy (MN) is one of the most commonest forms of glomerular disease in man and the most frequent cause of the adult idiopathic nephrotic syndrome. Some investigators recommend no treatment, while others propose aggressive therapy, including prednisolone plus an immunosupressant such as chlorambucil or cyclophosphamide. But a more effective way to treat MN is not defined yet. This study was to evaluate the effects of Patriniae Radix extract (PRE) on the MN induced by cBSA in mice. Methods : Mice were divided into 4 groups. The first group (normal) was injected with saline. The second group (control) was treated with cBSA (10 mg/kg i.p) only. The third group, named PRE-2S0, was treated with cBSA (10 mg/kg i.p) and PRE (250 mg/kg, p.o). The fourth group, PRE-500, was treated with cBSA (10mg/kg i.p) and PRE (500mg/kg, p.o). After cBSA and PRE treatment for 4 weeks, we measured change of body weight, 24hrs proteinuria, serum albumin, total cholesterol, triglyceride, BUN, creatinine, IgG, IgA, IgM, $TNF-\alpha$, $IL-1\beta$, and $IFN-\gamma$ levels and the mRNA expression of $IFN-\gamma$, IL-6, and IL-10. The morphologic changes of renal glomeruli were also observed with a light microscope and an electron microscope. Results : The levels of 24 hrs proteinuria and serum triglyceride. BUN. IgG. $TNF-\alpha$, and $IL-1\beta$ significantly decreased in both PRE groups, while the level of serum albumin significantly increased in both PRE groups. The mRNA expression of IL-10 in splenocytes considerably increased in both PRE groups. The mRNA expression of $IFN-\gamma$ and IL-6 in splenocytes considerably increased in both PRE group. In histological findings of kidney tissue, thickening of GBM decreased in both PRE groups. Conclusions : The present study suggests that PRE is effective when treating mice with MN induced by cBSA. More clinical data and studies are to be done for efficient application.

  • PDF

A Study on Counseling Process and Counseling Techniques Applying Analytical Psychology (분석심리학을 적용한 상담과정과 상담기법에 관한 연구)

  • Park, Won-Jin;Kim, Bo-Ki
    • Industry Promotion Research
    • /
    • v.4 no.1
    • /
    • pp.67-78
    • /
    • 2019
  • This study is to study Jung's analytical psychology and to study counseling process and counseling techniques based on the counseling theory derived from it. Jung divides the counseling process into four stages based on analytical psychology. The first stage is confession, and the prototype of analysis therapy is confession. The first step in the treatment process is to share secrets and reveal suppressed emotions. The second stage is elucidation, a process that clarifies by shedding light on the contents induced by the transfer. The third stage is the level of education. Explanation makes my counselors intelligent, but leaves them still in an incompetent state. At this stage, treatment goes beyond insight to train as a responsible client. The fourth stage is transformation. In the transformation phase with inner counselors, not only the debaters, but also the therapist is in the "in-analysis." Jung's counseling technique uses six things: dream analysis, use of symbols, word link test, symptom analysis, case history and MBTI. In conclusion, analytical psychology counseling has enabled, first, a more in-depth approach and understanding of the human mind, especially the unconscious world. Second, analytical psychology counseling has enabled us to recognize that all humans are human communities with a common mental structure through the concept of unconsciousness and archetypes. Third, analytical psychology counseling has allowed you to look at the meaning and purpose of life from a new perspective. Therefore, Jung emphasized that he should not be seen as having a pathological problem with patients, but as an omnipotent human being who wants to realize its fullness on his own.

Effects of photobiomodulation on different application points and different phases of complex regional pain syndrome type I in the experimental model

  • Canever, Jaquelini Betta;Barbosa, Rafael Inacio;Hendler, Ketlyn Germann;Neves, Lais Mara Siqueira das;Kuriki, Heloyse Uliam;Aguiar, Aderbal Silva Junior;Fonseca, Marisa de Cassia Registro;Marcolino, Alexandre Marcio
    • The Korean Journal of Pain
    • /
    • v.34 no.3
    • /
    • pp.250-261
    • /
    • 2021
  • Background: Complex regional pain syndrome type I (CRPS-I) consists of disorders caused by spontaneous pain or induced by some stimulus. The objective was to verify the effects of photobiomodulation (PBM) using 830 nm wavelength light at the affected paw and involved spinal cord segments during the warm or acute phase. Methods: Fifty-six mice were randomized into seven groups. Group (G) 1 was the placebo group; G2 and G3 were treated with PBM on the paw in the warm and acute phase, respectively; G4 and G5 treated with PBM on involved spinal cord segments in the warm and acute phase, respectively; G6 and G7 treated with PBM on paw and involved spinal cord segments in the warm and acute phase, respectively. Edema degree, thermal and mechanical hyperalgesia, skin temperature, and functional quality of gait (Sciatic Static Index [SSI] and Sciatic Functional Index [SFI]) were evaluated. Results: Edema was lower in G3 and G7, and these were the only groups to return to baseline values at the end of treatment. For thermal hyperalgesia only G3 and G5 returned to baseline values. Regarding mechanical hyperalgesia, the groups did not show significant differences. Thermography showed increased temperature in all groups on the seventh day. In SSI and SFI assessment, G3 and G7 showed lower values when compared to G1, respectively. Conclusions: PBM irradiation in the acute phase and in the affected paw showed better results in reducing edema, thermal and mechanical hyperalgesia, and in improving gait quality, demonstrating efficacy in treatment of CRPS-I symptoms.

A Study on the Implementation and Development of Image Processing Algorithms for Vibes Detection Equipment (정맥 검출 장비 구현 및 영상처리 알고리즘 개발에 대한 연구)

  • Jin-Hyoung, Jeong;Jae-Hyun, Jo;Jee-Hun, Jang;Sang-Sik, Lee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.6
    • /
    • pp.463-470
    • /
    • 2022
  • Intravenous injection is widely used for patient treatment, including injection drugs, fluids, parenteral nutrition, and blood products, and is the most frequently performed invasive treatment for inpatients, including blood collection, peripheral catheter insertion, and other IV therapy, and more than 1 billion cases per year. Intravenous injection is one of the difficult procedures performed only by experienced nurses who have been trained in intravenous injection, and failure can lead to thrombosis and hematoma or nerve damage to the vein. Nurses who frequently perform intravenous injections may also make mistakes because it is not easy to detect veins due to factors such as obesity, skin color, and age. Accordingly, studies on auxiliary equipment capable of visualizing the venous structure of the back of the hand or arm have been published to reduce mistakes during intravenous injection. This paper is about the development of venous detection equipment that visualizes venous structure during intravenous injection, and the optimal combination was selected by comparing the brightness of acquired images according to the combination of near-infrared (NIR) LED and Filter with different wavelength bands. In addition, an image processing algorithm was derived to threshehold and making blood vessel part to green through grayscale conversion, histogram equilzation, and sharpening filters for clarity of vein images obtained through the implemented venous detection experimental module.

A Study on the Comparison of Detected Vein Images by NIR LED Quantity of Vein Detector (정맥검출기의 NIR LED 수량에 따른 검출된 정맥 이미지 비교에 관한 연구)

  • Jae-Hyun, Jo;Jin-Hyoung, Jeong;Seung-Hun, Kim;Sang-Sik, Lee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.6
    • /
    • pp.485-491
    • /
    • 2022
  • Intravenous injection is the most frequent invasive treatment for inpatients and is widely used for parenteral nutrition administration and blood products, and more than 1 billion procedures are used for peripheral catheter insertion, blood collection, and other IV therapy per year. Intravenous injection is one of the difficult procedures to be performed only by trained nurses with intravenous injection training, and failure can lead to thrombosis and hematoma or nerve damage to the vein. Accordingly, studies on auxiliary equipment capable of visualizing the vein structure of the back of the hand or arm are being published to reduce errors during intravenous injection. This study is a study on the performance difference according to the number of LEDs irradiating the 850nm wavelength band on a vein detector that visualizes the vein during intravenous injection. Four LED PCBs were produced by attaching NIR filters to CCD and CMOS camera lenses irradiated on the skin to acquire images, sharpen the acquired images using image processing algorithms, and project the sharpened images onto the skin. After that, each PCB was attached to the front end of the vein detector to detect the vein image and create a performance comparison questionnaire based on the vein image obtained for performance evaluation. The survey was conducted on 20 nurses working at K Hospital.

Physiological and Psychological Responses to Landscape Experiences in a Natural Forest and a VR Forest (자연숲과 VR숲의 경관 체험에 따른 생리 및 심리적 반응)

  • Kim, Il-Doo;Shin, Won-Soep
    • Korean Journal of Environment and Ecology
    • /
    • v.36 no.5
    • /
    • pp.525-534
    • /
    • 2022
  • In this study, we investigated the psychological and physiological effects of experiences in real natural forests and virtual forests using artificially controllable VR. The experiment tested 60 adult college students in a natural forest and a graduate seminar room where external light was blocked. It evaluated the effects of the natural and the VR forest environments by comparing the psychological and physiological recovery of the subjects. Psychometric testing using the PANAS psychological index showed increased positive emotions and decreased negative emotions after experiencing forest scenery in the natural and VR forest environments. And a stress index, based on measuring cortisol in saliva, decreased significantly in the subjects in both environments. The experiment results can be used to support the creation of a psychological and physiological recovery environment with VR for those who cannot go to the natural forest due to certain restrictions such as physical distance, mobility difficulties, etc. It is expected that the results will be the basis for further research into the visual effects of forest healing and also for widening the use of VR, a technology of the fourth industry, in the field of forestry.

A of Radiation Field with a Developed EPID

  • Y.H. Ji;Lee, D.H.;Lee, D.H.;Y.K. Oh;Kim, Y.J.;C.K. Cho;Kim, M.S.;H.J. Yoo;K.M. Yang
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.67-67
    • /
    • 2003
  • It is crucial to minimize setup errors of a cancer treatment machine using a high energy and to perform precise radiation therapy. Usually, port film has been used for verifying errors. The Korea Cancer Center Hospital (KCCH) has manufactured digital electronic portal imaging device (EPID) system to verify treatment machine errors as a Quality Assurance (Q.A) tool. This EPID was consisted of a metal/fluorescent screen, 45$^{\circ}$ mirror, a camera and an image grabber and could display the portal image with near real time KIRAMS has also made the acrylic phantom that has lead line of 1mm width for ligh/radiation field congruence verification and reference points phantom for using as an isocenter on portal image. We acquired portal images of 10$\times$10cm field size with this phantom by EPID and portal film rotating treatment head by 0.3$^{\circ}$, 0.6$^{\circ}$ and 0.9$^{\circ}$. To check field size, we acquired portal images with 18$\times$18cm, 19$\times$19cm and 20$\times$20cm field size with collimator angle 0$^{\circ}$ and 0.5$^{\circ}$ individually. We have performed Flatness comparison by displaying the line intensity from EPID and film images. The 0.6$^{\circ}$ shift of collimator angle was easily observed by edge detection of irradiated field size on EPID image. To the extent of one pixel (0.76mm) difference could be detected. We also have measured field size by finding optimal threshold value, finding isocenter, finding field edge and gauging distance between isocenter and edge. This EPID system could be used as a Q.A tool for checking field size, light/radiation congruence and flatness with a developed video based EPID.

  • PDF