• 제목/요약/키워드: Light - leakage

검색결과 260건 처리시간 0.033초

자기광학센서를 이용한 강자성체 결함 탐상 (The Detection of Defects in Ferromagnetic Materials Using Magneto-Optical Sensor)

  • 김훈
    • 동력기계공학회지
    • /
    • 제8권3호
    • /
    • pp.52-57
    • /
    • 2004
  • A new non-destructive inspection technique has been developed. One characteristic of the technique is that defects are visualized by laser ray. Magnetic domains and domain walls of a magneto-optical sensor(MO sensor) are varied by the magnetic flux leaked by defects, and the variations are observed by the reflected light of the laser ray. The information of defect can remotely be inspected by this technique in a real time. This paper describes the results estimated on the 2-dimensional surface defects and opposite-side defects in a ferromagnetic material and the natural surface defect in a clutch disk wheel. The light region of a visible image and the magnitude of a reflected light increases as the input current of the magnetizer increases. The natural surface defect, that has not the width of crack's open mouth, can be also visualized like as 2-dimensional artificial defects.

  • PDF

Photo-Leakage Currents in Organic Thin-Film Transistor

  • Cho, Sang-Mi;Han, Seung-Hoon;Kim, Jun-Hee;Lee, Sun-Hee;Choo, Dong-June;Uchiike, H.;Oh, Myung-Hwan;Jang, Jin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.II
    • /
    • pp.1386-1389
    • /
    • 2005
  • We report the light illumination effect on the performance of pentacene organic thin-film transistor (OTFT). The TFT performance with and without illumination were measured at various temperatures. The off-state currents increase linearly with light intensity in the region of gate voltage where the holes are majority carriers in the TFT channel. The minimum photocurrents of OTFT increase with increasing light intensity.

  • PDF

가로등 전용 누전 개폐기의 차단효과에 대한 고찰 (Characteristics of Street Lamp Controller with Earth Leakage Contactor)

  • 이성재;신재식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.283-283
    • /
    • 2010
  • Smart street light controller is a product with advance micro controller base for energy saving in conventional street lighting systems. Intelligent Street light controller are specially developed for automation and energy saving in conventional street light systems and lighting systems. It is so designed that it operates on sunrise & sun set timings according to longitude of particular location with facilitate to set month wise civil twilight timings to cope up with all seasons. Dimming (Power down) mode selection switch on/off at fixed times with relay or contactor. Night dimming, staggering and intelligent control reduces burn hours and increases the lifetime of lamps with about 30% and low annual operating cost type base are among the most inexpensive wireless technologies available. Low initial costs As PLC wireless, there is no need to establish cable connection.

  • PDF

극히 얕은 $N^+$-P 실리콘 접합에서의 어발런치 현상 (Avalanche Phenomenon at The Ultra Shallow $N^+$-P Silicon Junctions)

  • 이정용
    • 반도체디스플레이기술학회지
    • /
    • 제6권3호
    • /
    • pp.47-53
    • /
    • 2007
  • Ultra thin Si p-n junctions shallower than $300{\AA}$ were fabricated and biased to the avalanche regime. The ultra thin junctions were fabricated to be parallel to the surface and exposed to the surface without $SiO_2$ layer. Those junctions emitted white light and electrons when junctions were biased in the avalanche breakdown regime. Therefore, we could observe the avalanche breakdown region visually. We could also observe the influence of electric field to the current flow visually by observing the white light which correspond to the avalanche breakdown region. Arrayed diodes emit light and electrons uniformly at the diode area. But, the reverse leakage current were larger than those of ordinary diodes, and the breakdown voltage were less than 10V.

  • PDF

Ultra-High Resolution and Large Size Organic Light Emitting Diode Panels with Highly Reliable Gate Driver Circuits

  • Hong Jae Shin
    • International journal of advanced smart convergence
    • /
    • 제12권4호
    • /
    • pp.1-7
    • /
    • 2023
  • Large-size, organic light-emitting device (OLED) panels based on highly reliable gate driver circuits integrated using InGaZnO thin film transistors (TFTs) were developed to achieve ultra-high resolution TVs. These large-size OLED panels were driven by using a novel gate driver circuit not only for displaying images but also for sensing TFT characteristics for external compensation. Regardless of the negative threshold voltage of the TFTs, the proposed gate driver circuit in OLED panels functioned precisely, resulting from a decrease in the leakage current. The falling time of the circuit is approximately 0.9 ㎲, which is fast enough to drive 8K resolution OLED displays at 120 Hz. 120 Hz is most commonly used as the operating voltage because images consisting of 120 frames per second can be quickly shown on the display panel without any image sticking. The reliability tests showed that the lifetime of the proposed integrated gate driver is at least 100,000 h.

두 개의 변압기를 이용한 전류불균형 개선 하프브리지 LLC 공진형 컨버터 (Current Unbalance Improved Half-bridge LLC Resonant Converter using the Two Transformers)

  • 유두희;정강률
    • 한국산학기술학회논문지
    • /
    • 제11권2호
    • /
    • pp.497-507
    • /
    • 2010
  • 본 논문은 상이한 누설인덕턴스를 가진 두 개의 변압기를 이용하여 전류불균형을 개선한 하프브리지 LLC 공진형 컨버터를 제안한다. 제안된 컨버터는 변압기의 누설인덕턴스와 자화인덕턴스 및 공진커패시턴스를 이용하여 공진하고, 넓은 부하영역을 가지며, 경부하에서도 영전압스위칭 조건을 만족한다. 직/병렬로 연결된 두 개의 변압기는 동작모드에 따라 변압기 또는 공진인덕턴스로써 교대로 동작하고, 변압기 2차측에는 누설인덕턴스를 이용하므로 별도의 출력 필터인덕턴스가 필요하지 않다. 또한 제안된 컨버터는 두 변압기의 상이한 누설인덕턴스와 하프브리지 스위치의 비대칭 펄스폭변조를 이용하여 2차측 정류다이오드의 전류불균형 문제를 개선한다. 본 논문에서는 제안된 컨버터의 동작원리를 모드별로 설명하고 프로토타입 컨버터의 설계 예를 제시한다. 제안된 컨버터의 우수한 성능을 입증하기 위하여 설계된 프로토타입의 회로파라미터로써 프로토타입 컨버터를 제작하고 실험하였다. 제안된 컨버터의 우수한 성능을 실험결과를 통하여 보인다.

치과용 접착제(Dental adhesive)를 사용한 제5급 복합레진수복물의 변연누출에 관한 실험적 연구 (IN VITRO STUDY ON THE MARGINAL LEAKAGE OF THE CLASS V COMPOSITE RESTORATION WITH DENTAL ADHESIVE)

  • 정근철;박동수;이찬영;이정석
    • Restorative Dentistry and Endodontics
    • /
    • 제10권1호
    • /
    • pp.135-144
    • /
    • 1984
  • This study was undertaken to evaluate the degree of the marginal leakage of composite restoration with 3 brands of dental adhesives by means of the dye penetration at the enamel and dentinal margins. 150 cavities of class V were prepared on the buccal and lingual surfaces of 75 extracted anterior and premolar teeth, which were devided into 3 groups. The cavities were filled with composite resin, Silar$^{(R)}$ (3M) and Heliosit$^{(R)}$ (Vivadent) after application of the dental adhesives, specifically Scotchbond$^{(R)}$ (3M) which is essentially composed with halophosphorus ester of Bis-GMA, Dentin Adhesit$^{(R)}$ (Vivadent) which is polyurethane resin, and Enamel Bond$^{(R)}$ (3M) which is a product of Bis-GMA with low viscosity at internal surfaces and margins of the cavities. All specimens were immersed in $37^{\circ}C$, 0.5% methylene blue solution for 24 hours after thermocycling at $4^{\circ}C$ and $60^{\circ}C$, embedded in acrylic resin, and sectioned with diamond disk into two parts. The sectioned specimens observed with the light microscope. The following results were obtained: 1. The group filled with Scotchbond$^{(R)}$-Silar$^{(R)}$ the other two groups at the enamel margins. 2. No significant difference in the degree of the marginal leakage had appeared between Dentin Adhesit$^{(R)}$-Heliosit$^{(R)}$ group an d Enamel Bond$^{(R)}$-Silar$^{(R)}$ group at the enamel margins. 3. Severe marginal leakage with penetration of dye to the floor of cavity had appeared from the all three groups and no significant difference in the degree of marginal leakage existed between the three groups at the dentinal margins.

  • PDF

V 급 와동 변연부 형태 및 복합레진 종류에 따른 변연 누출에 관한 실험적 연구 (An Experimental Study on the Effects of the Margin Designs and Composite Resins on the Marginal Leakage of Class V Resin Restorations)

  • 신용필;이찬영;이승종;이정석
    • Restorative Dentistry and Endodontics
    • /
    • 제12권1호
    • /
    • pp.107-116
    • /
    • 1986
  • The primary aim of this study was to assess the effects of the margin designs and composite resins on the marginal leakage of Class V resin restorations. 60 Class V cavities with $90^{\circ}$ butt joint, 60 with $45^{\circ}$ bevel joint, and 60 with concave joint were prepared on the labial surfaces of 38 extracted anterior teeth and the buccal and lingual surfaces of 71 premolars, and classified as the butt group, bevel group and concave group, respectively. After completion of the cavity preparation, Heliosit${(R)}$ was filled in 20 butt joint cavities, 20 bevel joint cavities, and 20 concave cavities. And Hi-Pol$^{(R)}$ and Palfique$^{(R)}$ were filled in the same manner, respectively. After finishing, all specimens were subjected manually to 50 thermal cycles at $4^{\circ}C$, $37^{\circ}C$, and $60^{\circ}C$. They were immersed in 0.5% methylene blue solution for 24 hours, and buccolingually sectioned with sectioning machine. The sectioned specimens were examined under the light microscope. The results indicated the following: 1. The bevel group showed the least amount of marginal leakage compared with the other two design groups, but the statistical analysis showed no significant difference at the 95% confidence level. 2. Hi-Pol$^{(R)}$ group showed the most severe marginal leakage compared with the other composite resin materials, but there was no significant difference in the groups. 3. The bevel-Heliosit$^{(R)}$ subgroup, which was filled with Heliosit$^{(R)}$ in the beveled cavities, showed the least amount of marginal leakage, but there was no significance in all the subgroups.

  • PDF

Analysis of Airtightness and Air Leakage of Wooden Houses in Korea

  • Kim, Sejong;Chang, Yoon-Seong;Park, Joo-Saeng;Shim, Kug-Bo
    • Journal of the Korean Wood Science and Technology
    • /
    • 제45권6호
    • /
    • pp.828-835
    • /
    • 2017
  • Airtightness of buildings is one of critical aspects of its energy performance. To build up references of airtightness of wooden houses built in Korea, blower door tests have been carried out in 42 houses since 2006. Causes of air leakage were investigated recently. The average value of air change rate was $3.7h^{-1}$ for light frame house and $5.5h^{-1}$ for post-beam construction at ACH50 (air change per hour at 50 Pa air pressure difference). Foam type insulation was more advantageous in ensuring building airtightness than glass fiber batt. Airtightness of wooden houses which were constructed after 2010 was improved to have less than $1.5h^{-1}$ of ACH50, threshold for application of artificial air change. The average air change rate of CLT (cross laminated timber) houses showed the lowest value, $1.1h^{-1}$, among the tested structures.

계면활성제가 첨가된 염수용액에 따른 폴리머 애자의 트래킹 성능 평가 (Tracking Performance Test of Polymer Insulator with Salt Solution which is added Surface Active Agent)

  • 조한구;한동희;이운용;임기조;최인혁
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1121-1124
    • /
    • 2004
  • Aging test to estimate life property of polymer insulator is executed through several international standard such as IEC 61109 and CEA tracking wheel test, but is not getting clear conclusion yet. There are two methods in the diagnosis method of polymer insulator such as off-line and on-line. The diagnosis methods in off-line are external condition analysis by the eye, contaminant analysis on surface, surface analysis, pollution withstand voltage test, power frequency flashover voltage test, lightning impulse flashover test, tensile fracture load test and flexural load test. The diagnosis methods in off-line most are the method for virgin and last aged sample. However, the diagnosis method in on-line is method that can be evaluate sample state as progressing continuously aging test in beginning, The diagnosis method in on-line is arranged as following: leakage current measurement, electric field, surface state investigation, thermal image, emitting light measurement and then so. In this paper, the tracking performance of polymer insulator with salt solution which is added surface active agent. The diagnosis of insulator sample has been analyzed by leakage current and visual examination.

  • PDF