• Title/Summary/Keyword: Lifting Power

Search Result 98, Processing Time 0.039 seconds

Fatigue Patterns on Trunk Muscles at Various Asymmetric Twisting Conditions (비틀림 동작에서의 허리근육의 피로도 패턴)

  • Jo, Yeong-Jin;Kim, Jeong-Ryong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.20 no.2
    • /
    • pp.71-82
    • /
    • 2001
  • Twisting posture in lifting tasks has been identified as a risk factor of low back pain. However, it has been usually estimated in terms of compressive stress or muscular activity. Thus, this study was conducted to predict the influence on muscular fatigue during lifting simulation. Fifteen young and healthy subjects were recruited and performed isometric trunk exertions during upright standing, two-level flexions and five-level asymmetric twisting conditions. EMG signals from five primary trunk muscles in right part of body were collected during 20sec for 45 different lifting conditions. RMS(root mean square) and MPF(mean power frequency) parameters were used to analyze the EMG signals. Twisting postures were significant in right erector spinae(ERSR), right latissimus dorsi(LATR), right internal oblique(INOR) for muscular activities. Especially, when trunk was $30^{\circ}$ CCW twisting posture. ERSR and INOR activities increased respectively by 11% and 3%. Regarding the trunk muscle fatigue, we found that MPF shifts in twisting posture increased 2.3 and 2.6 times for ERSR and INOR muscles respectively. Therefore, It is probable for workers to suffer from low back disorders when they were exposed to a extreme twisting posture during prolonged lifting. This study suggests NIOSH(National Institute for Occupational Safety and Health) lifting equation needs the time-duration multiplier in addition to asymmetric multiplier.

  • PDF

Development of a Lifting Utility with Balance-controlled Platform (작업대 수평유지식 과수원 고소작업차 개발)

  • Jang, Ik-Joo
    • Journal of Biosystems Engineering
    • /
    • v.36 no.3
    • /
    • pp.171-179
    • /
    • 2011
  • Facing the current hikes of labor wage and high oil price, it is needed to have energy-saving machinery which also enables us precise farm operations. Thus, it was necessary to develop a safe machine which allows secure and pleasant works along orchard slopes. In this study, a lifting utility with balance-controlled platform was developed. The platform utility could maintain to level the workbench while driving along slopes. Even the machine body was driven at the tilt angle ranges of ${\pm}20^{\circ}$, the platform bench could be maintained within ${\pm}0.5^{\circ}$ of a gimbal angle. In addition, the machine lifted up to 2.0 m using an electric-hybrid driving mechanism with a low noise. A tandem hybrid power source was developed with a DC 72 V, 100 AH for the Deep-Cycle batteries, charged with 3.5 kW gasoline generator as an auxiliary power source. HST, which is one of the CVT's, was adopted as a transmission device, and a crawer track was used for the safety of the vehicle against tip-over. The maximum lifting height of platform was is 2,500 mm, and the maximum extendable width was 2,900 mm.

Development of a Screw-Crane System for Pre-Lifting the Sternal Depression in Pectus Excavatum Repair: A Test of Mechanical Properties for the Feasibility of a New Concept

  • Park, Hyung Joo;Rim, Gongmin
    • Journal of Chest Surgery
    • /
    • v.54 no.3
    • /
    • pp.186-190
    • /
    • 2021
  • Background: Pre-lifting of the sternum marked a major turning point in pectus excavatum repair. The author developed the crane technique in 2002 and successfully applied it to more than 2,000 cases using sternal wire stitching. However, blind sternal suturing limited the use of the wire-stitch crane. We propose a novel screw for sternal lifting as a new tool for the crane technique. Methods: We developed a screw system strong enough to withstand the pressure needed for sternum lifting. The screw was designed to have a broader thread to hold the bony tissue securely. The screw's sustaining power was tested using the torsion, driving torque, and axial pull-out tests in a polyurethane block and ex-vivo porcine sternum. Results: The screws were easily driven into the sternum, and the head of the screw was connectable to the table-mounted retractor. In the torsion test, the 2° offset torsional yield was 4.53 N·m (reference value, 1 N·m). In the polyurethane block driving torque test, the maximum torque was 0.98 N·m (reference value, 0.70 N·m). The axial pull-out test was 446 N (reference value, 100 N). The maximum pull-out resistance in the ex-vivo porcine sternum model was 1,516 N. Conclusion: The screw crane was strong enough to sustain the chest wall weight to be lifted. Thus, the screws could effectively replace the sternal wire stitching in crane pre-lifting of the sternum. We expect that application of the screw-crane will be easy and that it will improve the safety and success rate of pectus repair surgery.

A Study on the Work-related Low Back Pain of Workers at a Refractories Manufacturing Factory (모 연와제조 공장 근로자의 작업과 관련된 요통 및 대책에 관한 연구)

  • Cheong, Hoe Kyeong;Lim, Hyun Sul;Kim, Ji Yong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.2
    • /
    • pp.289-297
    • /
    • 1997
  • Work-related low back pain(below LBP) is one of the major cause of morbidity, disability, limitation of activity and economic loss. Therefore the work-related LBP is one of the major issue in the field of industrial safety and health. This study was performed for detecting the risk factors and proposing the effective control programs of work-related LBP. The subjects were male workers employed at the welding and metal factory. The data was collected by self-reported questionnaire, interview and checking abdomen muscular and grasping power for two days on October, 1993. The contents of questionnaire were as follow: the experience of LBP, general characteristics, physical characteristics, employment status, type of work and working environment. The number of cases was 104 with a history of work-related LBP, so the prevalence of work-related LBP was 35.0%, and the number of controls was 140 without any history of LBP. As a result, marital status, educational level, abdomen muscular power, tenure, category of job, satisfaction of job, working posture, satisfaction for table and chair and lifting materials showed a statistical significance between the case and control groups. 284 Lifting jobs were quantified by NIOSH lifting equation method and ergonomic computer modelling methods. There were no significant differences in the action limit and disc compression force between group with LBP and without LBP. But in the lifting frequency and cumulative disc compression force there were significant differences. Therefore work-related LBP should be prevented by the ergonomic and environmental control.

  • PDF

development of Loader Equipped with 4WD and 4WS (I) (4 Wheel Driving Transmission) (4WD 및 4WS이 가능한 로더 개발(I) (4륜 구동 변속기))

  • 조현덕
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.7 no.6
    • /
    • pp.141-148
    • /
    • 1998
  • A loader is construction & road or agricultural machinery for lifting, moving, and mixing. This study deals with the agricultural mini loader for stock raising farming. The performance of the machine is established by pulling power, working lifting capacity, and minimum circling radius, etc. Also, driving easiness and endurance are very important in manufacturing. Thus, this study has developed the loader with the 4-wheel driving equipment by gear transmission, the 4-wheel steering equipment by power handle steering type, and the equipment making four wheels touch simultaneously on the rugged ground. The developed loader having these functions was very fit in a small cattle shed or a rugged ground. This study is divided into two parts; (I) development of 4WS transmission and (II) construction of the loader by 4WS system and other equipments.

  • PDF

A PSYCHOPHYSICAL STUDY ON WEIGHT SENSITIVITY BY THE FOOT AND HAND

  • Nah, Ken
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2001.11a
    • /
    • pp.76-80
    • /
    • 2001
  • The weight of shoes may serve as a determining factor of perceived comfort and feel to the consumer in their purchase and repurchase decisions of footwear. People, however, seem to have trouble in accurately judging the feeling of weight of shoes on their feet. This paper made a psychophysical study of subjects′ sensitivity to weight on their feet and in their hands. The experiment consisted of 3 tests according to the motions people make when they evaluate the feel of shoes: 1) vertical lifting of a shoe on the foot ("hefting" in on the foot) 2) swing the shod foot back and forth; 3) holding and lifting a shoe by hand ("hefting" it in the hand). The method of constant stimuli and magnitude estimation were used for the experiment with 20 subjects. Weber′s ratios and the power law exponents obtained for each of the three tests were 0.156 and 0.713, 0.108 and 0.970, and 0.065 and 1.249, respectively in the same order of the previously listed tests.

  • PDF

The Design, Fabrication, and Characteristic Experiment of Electromagnet to Control Element Drive Mechanism in System-Integrated Modular Advanced Reactor (일체형원자로 제어봉구동장치에 장착되는 전자석의 설계 및 특성해석)

  • 허형;김종인;김건중
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.4
    • /
    • pp.147-147
    • /
    • 2003
  • This paper describes the finite element analysis(FEA) for the design of electromagnet for Control Element Drive Mechanism(CEDM) in System-integrated Modular Advanced Reactor(SMART) and compared with the lifting power characteristics of prototype electromagnet. A thermal analysis was performed for the electromagnet. A model for the thermal analysis of the electromagnet was developed and theoretical bases for the model were established. It is important that the temperature of the electromagnet windings be maintained within the allowable limit of the insulation. since the electromagnet of CEDM is always supplied with current during the reactor operation. So the thermal analysis of the winding insulation which is composed of polyimide and air were performed by finite element method. As a result, it is shown that the characteristics of prototype electromagnet have a good agreement with the results of FEA. The thermal properties obtained here will be used as input for the optimization analysis of the electromagnet.

A Study on Wire-rope Type Furnace Scaffolding and Its Lifting System for Large-sized Boiler (대형 보일러 와이어로프 노내비계 및 인양시스템에 관한 연구)

  • HA, Seung Woo;Lee, Tae Ho;Lee, Hae Seung;Kim, Jeung Min;You, Tai Woo;Cho, Sun Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.7
    • /
    • pp.679-683
    • /
    • 2016
  • Boilers of large-sized coal-fired power plants are being operated under very poor conditions such as continuous operation or repeating of start-up and shutdown for a stable supply of electricity. Thus periodic inspection and maintenance are required to ensure reliability of operation. The loads of existing scaffolding systems for the maintenance of boilers are concentrated in the lower parts structurally, which may cause a serial collapse of the overall scaffolding system when there are problems in some members. Therefore, in this study, a safe furnace scaffolding system is developed by dispersing the loads in the upper part, as well as minimizing the hazards of serial collapsing. In addition, for cases where the direct installation of furnace scaffolding is challenging owing to the structure of the boiler tube, a lifting system for the installation of furnace scaffolding is developed so that furnace scaffolding can be supported to secure the integrity of the power generating facility.

Structural Safety Analysis of Lifting Device for Spent Fuel Dual-purpose Metal Cask (사용후핵연료 금속겸용용기 인양장비의 구조 안전성 해석)

  • Moon, Tae-Chul;Baeg, Chang-Yeal;Yun, Si-Tae;Choi, Byung-Il;Jung, In-Su
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.12 no.4
    • /
    • pp.299-314
    • /
    • 2014
  • A lifting device is used to deal with transport cask for the transportation of spent fuels from nuclear power plants. This study performed theoretical analysis and numerical simulation to evaluate the structural integrity of the lifting device based on Nuclear Safety and Security Commission(NSSC) Notice No.2013-27 and US 10CFR Part 71 ${\S}71.45$. The results of theoretical analysis showed that the maximum stresses of all components were below the allowable values. This result confirmed that the lifting device was structurally safe during operation. The results of finite element analysis also showed that it was evaluated to satisfy the design criteria bothyielding and ultimate condition. All components have been shown to ensure the structural safety due to sufficient safety margins. In other words, the safety factor was 3 or more for the yielding condition and was 5 or more for the ultimate condition.