• 제목/요약/키워드: Lift-off

검색결과 417건 처리시간 0.036초

동축원통 전극내 금속이물의 부상 및 하강전압 특성 (The Lift-off and Fall-down Characteristics due to Particles in Coaxial Electrode)

  • 이재걸;이곤;진상범;박현수;조국희;김경화;곽희로
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1711-1713
    • /
    • 1998
  • This paper describes the insulation characteristics of GIS by the free conducting particles under alternating voltage. The particles of the GIS can cause decrease in breakdown voltages. Various materials and sizes of free conducting particles were used to study the lift-off and fall-down characteristics. The measured lift-off voltage for copper particle agreed with the calculated one.

  • PDF

임펄스 표본화에 의한 탄성표면파 필터의 특성에 관한 연구 (A Study on Characteristics of SAW Filter by Impulse Sampling)

  • 이동윤;이종필
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.325-326
    • /
    • 2007
  • SAW filter was designed by optimization technique using impulse sampling. To carry out characteristics of SAW filter the uniform IDT was adapted. And SAW filter was fabricated on $LiNbO_3$ substrates to evaluate frequency response. To apply properties of photolithography, lift off method was used. Lift off method was superior to etch method in fabrication process, frequency response property was measured by network analyzer. From a measurement of acoustic property, SAW propagation velocity was 2663.5m/sec.

  • PDF

Flexible ECA Probe를 이용한 평판 및 용접부 검사 (Inspection of Welded Zone and Flat Plate Using Flexible ECA Probe)

  • 이창준;이규성;신충호;이경준;장윤영
    • 비파괴검사학회지
    • /
    • 제36권4호
    • /
    • pp.288-294
    • /
    • 2016
  • Flexible ECT (eddy current array) probe를 사용하여 판재 및 용접부에 존재하는 notch 결함을 MS-5800E와 OmniScan MX 장비로 검출능력을 비교하고, 주파수와 lift-off를 변수로 신호의 특성을 비교하고자 하였다. 실험 결과, 500, 1000, 1500 kHz를 사용하였을 때 notch 깊이가 증가할수록 신호의 진폭이 증가하는 것으로 나타났고, lift-off 변화에 따른 신호의 진폭은 선형적으로 감소하였다. 또한 용접부 결함은 probe와 시험체의 접촉면에 밀접한 관계가 있다. Probe와 시험체의 접촉면이 양호한 경우 검출감도가 우수하고 그렇지 않은 경우에는 검출감도가 떨어지는 것을 알 수 있었다.

제조공법에 따른 디스플레이 소자용 silver-grid 투명전극층의 특성 비교 (Comparison of characteristics of silver-grid transparent conductive electrodes for display devices according to fabrication method)

  • 최병수;최석환;류정호;조현
    • 한국결정성장학회지
    • /
    • 제27권2호
    • /
    • pp.75-79
    • /
    • 2017
  • 고밀도 플라즈마 식각 및 lift-off 두 가지 공정으로 honeycomb 형상의 Ag-grid 투명전극층을 제작하였고 제조 공법에 따른 광학적 및 전기적 특성을 비교하였다. 플라즈마 식각 조건 선정을 위하여 Ag 박막의 $10CF_4/5Ar$ 유도결합 플라즈마 식각특성을 조사하였다. 비교적 낮은 ICP source power 또는 rf chuck power 영역에서는 power 증가에 따라 Ag 식각속도가 증가하였고, 높은 power 조건에서는 $Ar^+$ 이온 에너지 감소 또는 $Ar^+$ 이온에 의한 F radical 제거로 인해 식각속도가 감소하였다. $10CF_4/5Ar$ 플라즈마 식각 공정에 의해 제작된 Ag-grid 전극층은 lift-off 공정으로 제작된 전극층에 비해 grid 패턴 형상의 왜곡이나 단절이 없는 더 우수한 grid 패턴 전사 효율과 가시광선 영역에서 더 높은 83.3 %(pixel 크기 $30{\mu}m$/선폭 $5{\mu}m$)와 71 %(pixel 크기 $26{\mu}m$/선폭 $8{\mu}m$)의 광투과율을 각각 나타내었다. 반면에 lift-off 공정으로 제작된 Ag-grid 전극층은 플라즈마 식각 공정 시편보다 더 우수한 $2.163{\Omega}/{\square}$(pixel 크기 $26{\mu}m$/선폭 $8{\mu}m$)과 $4.932{\Omega}/{\square}$(pixel 크기 $30{\mu}m$/선폭 $5{\mu}m$)의 면저항 특성을 나타내었다.

통신기기용 대역통과필터의 공정에 관한 연구 (A study on Photolithography of band pass filter for communication devices)

  • 이동윤;신용덕
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.247-250
    • /
    • 2002
  • SAW filters were fabricated on $LiNbO_3$ substrates to evaluate frequency response and properties of photolithography. In the both of etch and lift-off methods, lift off method was superior to etch method in fabrication process. Frequency response property was measured by network analyzer. From measurement of acoustic property, SAW propagation velocity was 3574.9m/sec for $LiNbO_3$ SAW filter.

  • PDF

A321 & A330항공기의 부양자세에 대한 비행자료 분석 (The analysis of flight data of A321 & A330 aircraft with lift angle)

  • 신대원;진영권;김일영;김칠영
    • 한국항공운항학회지
    • /
    • 제11권1호
    • /
    • pp.57-66
    • /
    • 2003
  • This study is performed to secure the safety of civil aviation by establishing systematic analysis ability of Flight Data Recorder. Through this study, we analysed the flight data of A321 & A330 aircraft with lift angles and take-off actions of flight crew members.

  • PDF

누설자속법을 이용한 저장탱크 바닥판재의 부식 평가 (Corrosion Assessment of Storage Tank Floor using Magnetic Flux Leakage Technique)

  • 원순호;조경식
    • 비파괴검사학회지
    • /
    • 제20권1호
    • /
    • pp.38-45
    • /
    • 2000
  • 본 연구에서는 누설자속법을 적용한 저장용 탱크 바닥판재의 부식측정 기술에 관한 연구를 수행하였다. 시험편은 두께 6mm 및 10mm 강판에 20%, 40% 60% 80%의 깊이를 갖는 홈을 가공한 대비시험편을 사용하였다. 영구자석을 이용하여 요크를 제작하고 홀센서를 이용하여 시험편에서 누설자속을 측정하였다. 실험결과는 인공홈에서 발생된 누설자속을 효과적으로 검출할 수 있다는 것을 보여주었다. 또한 transverse형 홀센서를 이용하여 시험편에 가공한 홈의 크기를 근사적으로 측정할 수 있다는 결과를 제시하였다. 홈의 위치에 따른 누설자속 진폭을 측정한 결과, 누설자속법으로는 판재 상, 하부의 홈 위치를 구별할 수 없다는 것이 밝혀졌고, lift-off 거리에 따라서 진폭이 현저하게 변하기 때문에 고정된 lift-off 거리를 유지하는 것이 중요하다는 사실을 보여주었다.

  • PDF

질소 희석된 부탄 부상화염에 있어서 화염진동에 관한 연구 (Study on Flame Oscillations in Laminar Lift-off Butane Flames Diluted with Nitrogen)

  • 윤성환;박정;권오붕;김정수
    • 대한기계학회논문집B
    • /
    • 제34권7호
    • /
    • pp.729-738
    • /
    • 2010
  • 질소로 희석된 부탄 층류 부상 화염에서 발생할 수 있는 화염진동 메커니즘을 살펴보기 위하여 실험적 연구를 수행하였다. 화염 진동은 층류 자유제트 부상 화염에서 5가지 영역으로 구분되었다: 화염 안정화 영역 (I), 열손실에 의한 진동 (II), 열손실에 의한 진동과 부력에 의한 진동이 혼재된 영역 (III),열손실에 의한 진동과 화염날림 직전의 진동이 혼재된 영역 (IV), 그리고 열손실에 의한 진동, 부력에 의한 진동 및 화염날림 직전의 진동이 모두 혼재된 영역(V). 각각의 화염진동의 특성을 규명하기 위해 화염의 시간에 따른 부상 높이 변화에 대한 FFT분석을 수행하였고 각 영역에 관련된 무차원 변수와 스트라훌 수의 조합으로 특성화 작업을 수행하였다.

수직전류 인가형 나노 스핀소자의 제조 및 자기저항 특성 (The Fabrication and Magnetoresistance of Nanometer-sized Spin Device Driven by Current Perpendicular to the Plane)

  • 전명길;이현정;정원용;김광윤;김철기
    • 한국자기학회지
    • /
    • 제15권2호
    • /
    • pp.61-66
    • /
    • 2005
  • 서브 마이크론 크기의 셀을 제조하기 위하여 종래의 방식인 전체시료구조를 증착한 후 이온밀링 방식으로 제조하는 대신에 Pt 스텐실 마스크 공정과 e-beam 리소 및 습식 식각 공정을 이용하여 배치형 submicron 셀을 lift-off 방식으로 제조하였다. $500nm{\times}500 nm,\;200nm{\times}300 nm$ 크기에 $CoFe(30 {\AA})/Cu(100{\AA})/CoFe(120{\AA}$) 3층 구조를 셀내에 증착하고 수직전류를 인가하여 자기저항 특성을 조사하였다. 자기저항 특성은 두 자성층의 보자력 차이를 이용하여 스핀의 반평형 구조를 유도하여 슈도 스핀밸브이며 각 셀의 크기에서 1.1, $0.8{\%}$의 자기저항비가 얻어졌다. 또한 전류인가에 따른 저항변화로부터 스핀전달 효과에 따른 스위칭 변화가 일어남을 확인하였으며, 이 구조에서 저항의 변화로부터 측정된 임계전류밀도는 약 $7.65{\times}10^{7}A/cm^2$였다.

리프트오프 현장시험을 이용한 앵커의 안정성 평가 (Stability Evaluation of Anchors Using Lift-off Field Test)

  • 최태식;윤중만;김용성;유승경;이강일
    • 한국재난정보학회 논문집
    • /
    • 제17권1호
    • /
    • pp.128-142
    • /
    • 2021
  • 연구목적: 본 연구는 기 시공된 앵커의 안전관리에 대하여 고찰을 실시하고 이를 통해 현장에서 실시한 리프트오프 시험결과를 평가한다. 또한 필요 시 대책공법에 대하여 연구하는 것을 목적으로 한다. 연구방법: 현장의 가시설 배면 36개의 지점에 리프트오프 시험을 수행한 후 얻어진 잔존긴장력에 대해 강연선항복하중, 허용긴장력 및 설계긴장력과 비교한다. 또한 이를 통해 안정성을 분석하고 앵커의 안정상태를 평가한다. 연구결과 및 결론: 시험결과 26개 지점의 잔존긴장력은 안정상태에 있었다. 그러나 10개 지점에서 잔존긴장력이 설계긴장력 보다 크고 허용긴장력 보다 작은 것으로 분석되었고 파단문제가 발생할 수 있는 불안정상태인 것으로 평가되었다. 따라서 10개 지점에서 나타난 불안정상태의 앵커는 주기적인 계측과 품질시험을 통한 관리 및 관찰을 수행해야 하며 해당 지점뿐 아니라 주변 지점에 대해서도 주기적인 관찰을 실시하여 안정상태를 유지시켜야 한다.