Corrosion Assessment of Storage Tank Floor using Magnetic Flux Leakage Technique

누설자속법을 이용한 저장탱크 바닥판재의 부식 평가

  • Won, Soon-Ho (Nondestructive Evaluation Group, Korea Institute of Machinery and Materials) ;
  • Cho, Kyung-Shik (Nondestructive Evaluation Group, Korea Institute of Machinery and Materials)
  • 원순호 (한국기계연구원 비파괴평가그룹) ;
  • 조경식 (한국기계연구원 비파괴평가그룹)
  • Published : 2000.02.28

Abstract

In this research, MFL technique has been studied for the inspection of storage tank floor. The reference specimens having 20%, 40%, 60% and 80% slot's are fabricated using the carbon steel plates of a 6mm and 10mm thick. Powerful permanent magnets and Hall effect sensors are used to this application. It is shown that our system is able to detect metal loss like a slot. Also, it is possible that slot diameter is measured using transverse type of Hall generator. It is demonstrated that MFL can not differentiate between the response from top side and bottom side slot. Flux leakage response from a bottom side indication is significantly lower in amplitude than that from an equivalent top side slot. It is essential to know this sensor lift-off distance because the MFL signal also changes considerably with the sensor lift-off distance.

본 연구에서는 누설자속법을 적용한 저장용 탱크 바닥판재의 부식측정 기술에 관한 연구를 수행하였다. 시험편은 두께 6mm 및 10mm 강판에 20%, 40% 60% 80%의 깊이를 갖는 홈을 가공한 대비시험편을 사용하였다. 영구자석을 이용하여 요크를 제작하고 홀센서를 이용하여 시험편에서 누설자속을 측정하였다. 실험결과는 인공홈에서 발생된 누설자속을 효과적으로 검출할 수 있다는 것을 보여주었다. 또한 transverse형 홀센서를 이용하여 시험편에 가공한 홈의 크기를 근사적으로 측정할 수 있다는 결과를 제시하였다. 홈의 위치에 따른 누설자속 진폭을 측정한 결과, 누설자속법으로는 판재 상, 하부의 홈 위치를 구별할 수 없다는 것이 밝혀졌고, lift-off 거리에 따라서 진폭이 현저하게 변하기 때문에 고정된 lift-off 거리를 유지하는 것이 중요하다는 사실을 보여주었다.

Keywords