• Title/Summary/Keyword: Level shift

검색결과 892건 처리시간 0.025초

2차측 보조 회로를 이용한 ZVZCS Three Level DC/DC 컨버터에 관한 연구 (A Study on the Zero-Voltage and Zero-Current-Switching Three Level DC/DC Converter using Secondary Auxiliary Circuit)

  • 배진용;김용;권순도;김필수;이은영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.320-323
    • /
    • 2001
  • A ZVZCS(Zero-Voltage and Zero-Current-Switching) Three Level DC/DC Converter is presented to secondary auxiliary circuit. The converter presented in this paper used a phase shift control with a flying capacitor in the primary side to achieve ZVS for the outer switch. A secondary auxiliary circuit, which consists of one small capacitor and two small diode, is added in the secondary to provides ZVZCS conditions to primary switches, and aids to clamp secondary rectifier voltage. The auxiliary circuit Includes neither lossy component nor addition active switch, which makes the proposed converter efficient and effective. The principle of operation, feature, and design considerations are illustrated and verified through the experiment with a 500W 50kHz prototype converter.

  • PDF

PSC(Phase Shifted Carrier) PWM 방식에 따른 20MW HVDC 시스템의 고조파 분석 (Harmonic Analysis of 20MW MMC HVDC System with PSC(Phase Shift Carrier) PWM)

  • 홍정원;김준성;유현호;정홍주
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.442-443
    • /
    • 2018
  • 본 논문에서는 스위칭 기법에 따른 MMC HVDC 시스템의 고조파 특성을 분석하여, 그 결과를 소개하였다. MMC 토폴로지 기반의 VSC HVDC는 SM(Sub-Module)을 다수를 직렬 연결하여, 이를 개별 제어함으로 써 스위칭 기법에 따라 동일한 수의 SM을 가지고 출력전압의 레벨수를 조정하여 고조파 특성을 개선할 수 있다. (주) 효성에서는 행원 풍력단지에 구축한 20MW HVDC 시스템의 고조파 특성을 분석하기 위하여, 각각 11-level과 21-level의 출력전압을 형성하여 성능 시험을 진행하였다. 본 논문에서는 PSC PWM 방식을 이용하여 출력전압 Level 형성에 따른 고조파 특성 시험에 대한 결과를 소개하였다.

  • PDF

Optimized Automatic Noise Level Calculations for Broadband FT-ICR Mass Spectra of Petroleum Give More Reliable and Faster Peak Picking Results

  • Hur, Manhoi;Oh, Han-Bin;Kim, Sung-Hwan
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권11호
    • /
    • pp.2665-2668
    • /
    • 2009
  • A new algorithm for determining noise level is proposed for more reliability in interpreting spectral data for complex Fourier transform ion cyclotron resonance (FTICR) mass spectra of petroleum. In the new algorithm, a moving window with a fixed number of data points was adopted, instead of a fixed m/z width. In the analysis of petroleum, it was found that a moving window of 50,000 or more data points was optimal. This optimized automated peak picking performed well even with frequency-dependant noise in the mass spectrum. Additionally, this fast, automated peak picking algorithm was suitable for the analysis of a large set of samples.

2차측 결합 인덕터를 이용한 ZVZCS Three Level DC/DC 컨버터에 관한 연구 (A Study on the Zero-Voltage and Zero-Current-Switching Three Level DC/DC Converter using Secondary Coupled Inductor)

  • 배진용;김용;백수현;김필수;이은영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.200-204
    • /
    • 2001
  • A ZVZCS(Zero Voltage and Zero Current Switching) Three Level DC/DC Converter is presented to secondary auxiliary circuit. The new converter presented in this paper used a phase shift control with a flying capacitor in the primary side to achieve ZVS for the outer switch. A secondary auxiliary circuit, which consists of one small capacitor two small diode and one coupled inductor is added in the secondary to provides ZVZCS conditions to primary switches, ZVS for outer switches and ZCS for inner switches. Many advantages including simple circuit topology high efficiency, and low cost make the new converter attractive for high power applications. The principle of operation, feature and design considerations are illustrated and verified through the experiment with a 1kW 50kHz IGBT based experimental circuit.

  • PDF

2차측 보조회로를 이용한 ZVZCS Three-Level 컨버터에 관한 연구 (A study on the ZVZCS(Zero-Voltage and Zero-Current-Switching) Three-Level converter using the secondary auxiliary circuit)

  • 김동원;김용;배진용;이은영;이규훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 에너지변화시스템부문
    • /
    • pp.161-164
    • /
    • 2009
  • This paper presents the ZVZCS(Zero Voltage and Zero-Current-Switching) Three-Level converter using the secondary coupled inductor and auxiliary capacitor. The converter with phase-shift control is proposed to reduce the circulating loss in primary and the voltage stress in secondary side. Using a coupled winding of the output inductor, two auxiliary capacitors are generated to reset the primary current at circulating interval.

  • PDF

CMOS 뉴런의 활성화 함수 (CMOS neuron activation function)

  • 강민제;김호찬;송왕철;이상준
    • 한국지능시스템학회논문지
    • /
    • 제16권5호
    • /
    • pp.627-634
    • /
    • 2006
  • CMOS 인버터 특성곡선의 기울기를 조절하는 방법과 y축으로 이동할 수 있는 방법을 제안하였다. 기울기의 변경과 y축으로 이동은 트랜지스터의 문턱 값을 조절하는 방법을 사용하였다. 그리고 특성곡선의 중심에서는 두 트랜지스터 모두 포화영역에 머물러 있음에 착안하여, 단극성 뉴런의 특성곡선을 만드는 방법을 제안하였다. 제안된 방법은 회로레벨의 시뮬레이션을 통해 검증하였으며, 회로레벨의 시뮬레이션은 OrCAD사의 PSpice(Professional Simulation Program with Integrated Circuit Emphasis)를 사용하였다.

Social Identity and Regulatory Focus: Can Collective Orientation Influences Consumers' Message Evaluation?

  • Park, Sangwoo;Heo, Dakyeong;Shin, Dongwoo
    • Asia Marketing Journal
    • /
    • 제21권1호
    • /
    • pp.89-112
    • /
    • 2019
  • To investigate the interplay between individual and collective self-regulations, the authors propose a dialectic process that describes the changes in the locus of self-regulations between individual self and collective self. The results from three studies display a strong support for the two sets of hypotheses drawn from the proposed process. Our findings demonstrate that consumers can move the locus of self-regulation from individual-self to collective-self when a social identity is activated (preliminary study and study1). Further examination of regulatory swing between individual and collective regulatory orientations revealed group identification as a key variable in determining the locus of self-regulation (study2). While a consumer with a high level of group identification changes her locus of self-regulation from an individual to a collective (a regulatory shift) and evaluated messages and products framed consistent with their group orientation, a consumer with low level of group identification maintains her locus of self-regulation in her personal level of self (a regulatory preservation) and evaluated messages and products framed consistent with their personal regulatory focus.

일부 대학병원 간호사의 업무인지정도에 관한 조사연구 (A Study on the Perception Level of Nursing Activities of Nurses in General Hospitals)

  • 김춘길
    • 대한간호
    • /
    • 제30권1호
    • /
    • pp.51-62
    • /
    • 1991
  • The Study was carried out for the purpose of investigating the degree of perception in nursing activities. This study reports perceptions of nurses on the choices they make among competing activities, contrasts this perception with their opinion of what tasks they would like to spend time on. A sample of 231 clinical nurses was selected to participate in this study at two genernal hospitals in Seoul. The data was collected from July 10th to 25th, 1990. Subjects were instructed to rate one of five points likert type scale on the 43 items of nursing activities. Analysis of data was done by means of the SPSS-X Program using frequency, t-test and ANOVA. The results of this study were as follows; 1. The characteristics of the subjects were as follows: The age group of 25-29 yeares was 45.9%. For religion, Christians had the highest score, 68.4 % and singles in subjects were 81.4%. For academic background, 64.5% were graduated from nursing junior colleges. In the subjects, staff nurses were 86.6%. 22.5% of them had worked for less than 1 year and 20.8% had 37 months to 5 years experience at the time of the survey. 62.8% were satisfied with the job. 2. The perception level of nursing activities: 1) The mean score for perception of professional nursing functions was 4.157 point, with a maximum score set. at 5 points. The mean score for perception of priorities was 3.781. Perception of spending time was 3.932. 2) In perception of professional nursing functions, more important items were Aseptic technique (4.866), Shift and exchange of information concerning patients(4.654), Observing patients (4.799). Less important items were Transporting patients(3.411), Changing linens(3.442), Giving a bed shampoo (3.506). In priorities, more important ones. were Aseptic technique(4, 706), Shift and exchange of information concerning patients (4.524.), Observing patients(4.390), Taking vital signs (4.355). And less important ones were Changing linens (3.100), Giving bed baths(3.113), Giving back rubs(3.121). In spending time, more important ones were Aseptic technique(1.706), Observing patients (4.532), Shift and exchange of information concerning patients(4.532). And less important ones were Changing lines(3.368), Transporting patients(3.394), Giving bed baths(3.450). 3) In the role perception level, the mean distribution of perception was 3.511- 4.335; the role was perceived to be in order of frequency as a facilitator, coordinator, change agent and advocator role. The most important scale of factors by nursing activities was indirect nursing activities.

  • PDF

일 상급종합병원 병동간호사의 업무량 측정 및 간호사 배치수준의 적절성 연구: 혼합연구 설계 적용 (Analysis of the Adequacy of Nurse Staffing Level through the Estimation of Nursing Activity Hours and Implementation of Focus Group Interviews in a Tertiary Hospital: Using a Mixed-Method Design)

  • 김현주;이선희;이재정;성선숙;양희;이향열
    • 대한간호학회지
    • /
    • 제54권2호
    • /
    • pp.237-249
    • /
    • 2024
  • Purpose: This study aimed to examine the adequacy of current nurse staffing levels by identifying nursing activities and workload. Methods: The study used a mixed-method design. A nursing activity survey was conducted using the work sampling method over 2 working days with 119 general ward nurses. A focus group interview was conducted with 12 nurses. Quantitative and qualitative data were analyzed using SPSS 20.0 and content analysis, respectively. Results: The most amount of time was spent on medication (in direct nursing) and electronic medical record documentation (in indirect nursing). The appropriate nurse-to-patient ratio is 1:7.7 for the day shift, 1:9.0 for the evening shift, and 1:11.9 for the night shift. However, the current nurse-to-patient ratio is 1:9.4, 1:11.0, and 1:13.8 for the day, evening, and night shifts, respectively. Therefore, the current nurse staffing level is insufficient for the workload. In the focus group interview, the main reasons cited for being unable to complete tasks within working hours were communication and coordination, and the nursing electronic medical record. The essential nursing activities of basic nursing and emotional support were overlooked owing to a heavy workload. Therefore, an adequate nurse staffing level should be higher than the measured quantitative workload. Conclusion: These results suggest the general wards of tertiary hospitals should evaluate the adequacy of their current nurse staffing and allocate sufficient nurses to improve patient safety and nursing care quality.

EWMA 피드백 공정 조정에서 이상원인의 영향 (Impact of Special Causes on EWMA Feedback Process Adjustment)

  • 이재준;전상표;이종선
    • 품질경영학회지
    • /
    • 제31권2호
    • /
    • pp.183-193
    • /
    • 2003
  • A special cause producing temporary deviation in the underlying process can influence on process adjustment in responsive feedback control system. In this paper, the impact of special causes on the EWMA(Exponentially Weighted Moving Average) forecasts and the process adjustment that is based on the EWMA forecasts are derived. For some special causes with patterned type of contamination, the influence of the causes on the output process are explicitly investigated. A data set, contaminated by a special cause of level shift, is analyzed to evaluate the impact numerically.