• 제목/요약/키워드: Length of shear wall

검색결과 115건 처리시간 0.022초

Coronary Artery Numerical Flow Analysis for Determination of Bypass Graft Geometric Parameters

  • Kim, Hyung-Min;Kim, Woong
    • Journal of Mechanical Science and Technology
    • /
    • 제19권3호
    • /
    • pp.905-912
    • /
    • 2005
  • A computational investigation of blood flow in a coronary artery grafted by artificial bypass was performed to determine such geometric parameters as the curvature of radius, approach length, and angle of end-to-side anastomosis. Transient flow features in the host artery were computed using FVM and SIMPLE algorithms. We compared flow distributions and wall shear stresses in two simple models, planar and non-planar, and confirmed that the non-planar bypass model was more conducive to suppressing intimal hyperplasia. Our non-planar model with $60^{\circ}$ of anastomosis and a 1.0 diameter approach length and radius of curvature predicts a relatively small, spatially-extended high-OSI (>0.01) zone, as well as an increased average wall shear stress on this zone.

민감도 해석을 이용한 전단벽-골조 구조시스템의 강성최적설계 (Stiffness-based Optimal Design of Shear Wall-Frame Structure System using Sensitivity Analysis)

  • 이한주;김호수
    • 한국전산구조공학회논문집
    • /
    • 제19권1호
    • /
    • pp.63-71
    • /
    • 2006
  • 본 연구에서는 민감도 해석을 이용하여 전단벽-골조 구조시스템의 횡변위를 정량적으로 제어할 수 있는 강성최적설계방안을 제시하고자 한다. 이를 위해 먼저 골조와 전단벽요소 사이의 변위자유도 적합성 문제를 해결하기 위한 요소강성행렬을 구성하며, 또한 수학적계획법의 일반성을 유지하면서도 큰 규모의 문제도 효율적으로 다를 수 있는 근사화 재념을 도입하여 횡변위 구속조건식을 설정한다. 아울러 전단벽 및 골조부재의 단면특성 관계식을 설정함으로써 설계변수의 수를 줄여주고, 이를 이용하여 강성행렬도함수의 산정을 용이하게 한다. 특히 골조의 경우 초기에 주어진 단면형상이 최적설계 과정동안 계속 유지된다는 가정을 이용하여 최적설계결과에서 구해진 단면특성에 따라 부재단면크기를 산출하고, 전단벽은 사용자의 의도에 따라 두께 또는 부재길이를 재산정하는 방안을 강구한다. 이와 같이 제시된 강성최적설계기법의 효용성을 검토하기 위해 두 가지 형태의 20층 전단벽-골조 구조물의 예제가 고려된다.

전단벽의 내진보강을 위한 방법에 관한 연구 (Retrofitting Device to Increase Seismic Resistant Capactiy of Shear Walls)

  • 홍성걸;이지형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.25-28
    • /
    • 2005
  • The elastic buckling load or strength of a concentrically loaded slender metal column may be increased many times by reinforcing it with an assemblage of pretensioned stays and rigidity connected crossarm members. The complete system is herein referred to as a 'stayed column'. The purpose of the pretensioned stays and crossarm members is to introduce, at several points along the length of the column, restraint against translation and rotation and thereby decrease the effective unsupported buckling length of the column. This paper verifies that pretensioned cable of stayed column is effective for cyclic load and increases strength of shear wall against earthquake by reinforcing side of wall. Design process of stayed column which satisfies demanded capacity and ductility of wall is presented by analyzing result of experiment.

  • PDF

Shear Layer and Wave Structure Over Partially Spanning Cavities

  • Das, Rajarshi;Kim, Heuy Dong;Kurian, Job
    • 한국가시화정보학회지
    • /
    • 제11권2호
    • /
    • pp.46-54
    • /
    • 2013
  • Study of the wave structure and shear layer in the vicinity of a wall mounted cavity is done by time averaged colour schlieren and time resolved instantaneous shadowgraph technique in an M=1.7 flowfield. Effect of change of cavity width on flow structure is investigated by using constant length to depth (L/D) ratio cavity models with varying length to width (L/W) ratio of 0.83 to 4. The time averaged shock wave structure was observed to change with change in cavity width. Dependence of the shock angle at the leading edge on the shear layer width is also evident from the images obtained. Unsteadiness in the flow field in terms of shear layer dynamics and quasi steady nature of shock waves was evident from the images obtained during instantaneous shadowgraph experiments. Apart from the leading and trailing edge shocks, several other waves and flow features were observed. These flow features and the associated physical phenomena are discussed in details and presented in the paper.

Plastic hinge length for coupled and hybrid-coupled shear walls

  • Abouzar Jafari;Meysam Beheshti;Amir Ali Shahmansouri;Habib Akbarzadeh Bengar
    • Steel and Composite Structures
    • /
    • 제48권4호
    • /
    • pp.367-383
    • /
    • 2023
  • A coupled wall consists of two or more reinforced concrete (RC) shear walls (SWs) connected by RC coupling beams (CBs) or steel CBs (hybrid-coupled walls). To fill the gap in the literature on the plastic hinge length of coupled walls, including coupled and hybrid-coupled shear walls, a parametric study using experimentally validated numerical models was conducted considering the axial stress ratio (ASR) and coupling ratio (CR) as the study variables. A total of sixty numerical models, including both coupled and hybrid-coupled SWs, have been developed by varying the ASR and CR within the ranges of 0.027-0.25 and 0.2-0.5, respectively. A detailed analysis was conducted in order to estimate the ultimate drift, ultimate capacity, curvature profile, yielding height, and plastic hinge length of the models. Compared to hybrid-coupled SWs, coupled SWs possess a relatively higher capacity and curvature. Moreover, increasing the ASR changes the walls' behavior to a column-like member which decreases the walls' ultimate drift, ductility, curvature, and plastic hinge length. Increasing the CR of the coupled SWs increases the walls' capacity and the risk of abrupt shear failure but decreases the walls' ductility, ultimate drift and plastic hinge length. However, CR has a negligible effect on hybrid-coupled walls' ultimate drift and moment, curvature profile, yielding height and plastic hinge length. Lastly, using the obtained results two equations were derived as a function of CR and ASR for calculating the plastic hinge length of coupled and hybrid-coupled SWs.

SC구조의 벽-바닥 접합부의 정착강도에 관한 연구 (A Study on the Bond Strength of Wall-Slab Joint of Steel Plate-Concrete Structures)

  • 최경민;김기성;김병국;김원기;최완철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.321-324
    • /
    • 2006
  • An experimental study on the bond strength of wall-slab joint in SC(steel plate-concrete) structure was performed. Six-full scale specimens were tested. Specimens were constructed with key variables, such as, development length, location of the bar and quantity of the shear bar. The experimental results, show that as the development length and quantity of the shear bar increase, the bond strength increases. As the bars is located on the inside the stud bolt, the bond performance was highly increased compared to the bars located out of plane of the stud bolts.

  • PDF

PHC-W 흙막이를 활용한 건축영구벽체에서 PHC-W말뚝과 증설벽체를 합벽시키는 전단연결재의 인발거동에 관한 연구 (A Study on the Pullout Behavior of Shear Connectors which Fix the Additional Wall to the PHC-W Piles in the PHC-W Type Permanent Building Retaining Wall)

  • 진홍민;김성수;최정표;최용규
    • 한국지반공학회논문집
    • /
    • 제33권12호
    • /
    • pp.107-113
    • /
    • 2017
  • PHC-W 흙막이를 건축영구벽체로 활용하기 위해서 전단연결재를 이용하여 PHC-W말뚝과 증설벽체를 일체화 시켜야 한다. 전단연결재의 인발 거동은 2가지 인발 거동 유형으로 나타났다. 첫 번째 인발 거동 유형은 최대 인발저항력에 도달한 이후 정착부가 파괴되어 전단연결재가 정착부위에서 뽑혀 나오는 인발변위 거동을 나타내었다. 두 번째 인발거동 유형은 최대인발저항력에 도달한 이후에도 정착부가 파괴되지 않고 인발변위가 점진적으로 증가하는 거동을 나타내었다. 최대 인발저항력은 강재 앵커 전단연결재가 이형 철근 전단연결재보다 크게 나타났다. 동일 재료의 전단 연결재에서는 직경이 클수록 그리고 정착 길이가 길수록 최대 인발저항력은 큰 값을 나타내었다. 최대인발력에 상응하는 인발변위는 재료, 직경 및 정착길이에 상관없이 다양한 범위를 나타내었다. 즉 A-D20 전단연결재의 경우 8~10mm이었으며 A-D16, D-D19 그리고 D-D16 전단연결재의 경우 14~20mm이었는데 정착길이가 50, 80mm에서는 6~10mm로 나타났다.

결함 상세를 포함하는 철근콘크리트 전단벽의 수치 모델에 관한 실험적 평가 (Experimental Assessment of Numerical Models for Reinforced Concrete Shear Walls with Deficient Details)

  • 전성하;박지훈
    • 한국지진공학회논문집
    • /
    • 제20권4호
    • /
    • pp.211-222
    • /
    • 2016
  • Reinforced concrete shear walls with deficient reinforcement details are tested under cyclic loading. The deficiency of reinforcement details includes insufficient splice length in U-stirrups at the ends of horizontal reinforcement and boundary column dowel bars found in existing low- to mid-rise Korean buildings designed non-seismically. Three test specimens have rectangular, babel and flanged sections, respectively. Flexure- and shear-controlled models for reinforced concrete shear walls specified in ASCE/SEI 41-13 are compared with the flexural and shear components of force-displacement relation extracted separately from the top displacement of the specimen based on the displacement data measured at diverse locations. Modification of the shear wall models in ASCE/SEI 41-13 is proposed in order to account for the effect of bar slip, cracking loads in flexure and shear. The proposed modification shows better approximation of the test results compared to the original models.

CSB (Confined Socket Bolt) 전단연결재의 전단 성능 평가 (Evaluation of Shear Performance for CSB (Confined Socket Bolt) Shear Connector )

  • 황승현;문주현;홍종국;전종철;심재일
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권2호
    • /
    • pp.8-16
    • /
    • 2023
  • 이 연구에서는 흙막이용 CIP(cast in placed pile)를 영구적인 지하외벽으로 활용하기 위해 제시한 CSB(confined socket bolt) 전단연결재의 전단 성능을 평가하였다. CSB 전단 성능 평가를 위한 푸쉬아웃(push-out) 실험의 주요 변수는 CIP의 종류, CSB 전단연결재 종류, L/d, 무근 콘크리트, 방수재 및 철근콘크리트 말뚝의 압축강도로 설정하였다. 실험결과, H-형강 말뚝 실험체들의 파괴모드는 모두 CSB 전단연결재 파단에 의해 지배되었다. 철근콘크리트 말뚝 실험체들의 파괴모드는 철근콘크리트 말뚝의 압축강도가 증가할수록 콘크리트의 파괴보다 CSB 전단연결재의 파단에 의해 지배되었다. 고강도 볼트 및 이형철근의 CSB 전단연결재 실험체의 최대 내력은 일반강도 볼트의 CSB 전단연결재 실험체에 비해 H-형강 말뚝의 경우 약 1.22배 및 1.20배 높았으며, 철근콘크리트 말뚝의 경우 약 1.10배 및 1.16배 높았다. 그리고 푸쉬아웃 실험에서 최대 내력은 CSB 전단연결재의 길이 및 철근 중첩에 대한 영향이 미미하였다. KDS 기준에 의해 산정된 전단내력은 실험결과를 안전측으로 평가하였다.

끼움벽과 단주효과를 고려한 학교건축물의 내진성능평가 (Seismic Performance Evaluation of School Building Short Column Effect)

  • 주창길;한주연;박태원
    • 교육시설 논문지
    • /
    • 제21권2호
    • /
    • pp.33-39
    • /
    • 2014
  • In the case of low-rise buildings in seismic performance evaluation, lateral force resistance of the pillars affects the seismic performance of the building. Evaluation of the seismic performance of the column is determined by the holding performance is evaluated by comparing the shear strength and bending strength it was destroyed bylow intensity. In case of the school building, in order to install the large windows for ventilation and lighting of the partition walls are located between the pillars. The case of the pillars of these, shear failure occurs in the event of an earthquake is often, in the seismic performance evaluation, partition wall and the wall of the shim is evaluated ignoring, pillar of the general pillars If you have to calculate the results of the seismic performance distorted that are destroyed by bending behavior can be evaluated as often. Results of the study, when assessed by distinguishing the effective length of the column, it was found that when a seismic load is applied, it is possible to accurately predict the failure mode, reliable results of seismic performance evaluation of the school building.