• Title/Summary/Keyword: Length Standard

검색결과 1,965건 처리시간 0.031초

아미노산 분석기에 의한 제제중 Taurine의 분리 정량에 관한 연구 (Determination of Taurine in Preparations by Amino Acid Autoanalyzer)

  • 박만기;한달수
    • 약학회지
    • /
    • 제28권1호
    • /
    • pp.21-23
    • /
    • 1984
  • High performance amino acid analyzing method has been developed for the routine analysis of taurine in preparations. Ion-exchange resin #2619 Hitachi Custom Ion-Exchange Resin, $2.6(I.D.){\times}150$(length)mm was used as column, buffer I, pH 3.3 as mobile phase. The retention time of taurine was 7 minutes. Calibration curve by peak height for standard taurine was linear from 2.5ppm to 25ppm. The reproducibility showed relative standard deviation $\pm$1.9% when analyzed 10 times for standard solution. The samples could be continuously analyzed without regenerating the resin between samples. Five samples were applied to column every 12 min. and then the resin was regenerated for 30 min. during one analyzing cycle time, 90 min. The automatic amino acid analyzer has made it possible to assay multiple samples in a relatively short period of time using the analytical magnetic program card. The high sensitivity and specificity of the analytical column of the automatic amino acid analyzer permits the routine analysis of taurine in preparations.

  • PDF

스텐다드 셀의 자동배치 시스템에 관한 연구 (A Study on the Automatic Placement System for Standard Cell)

  • 강길순;경종민;박송배
    • 대한전자공학회논문지
    • /
    • 제23권4호
    • /
    • pp.557-564
    • /
    • 1986
  • This paper describes a standard cell placement strategy which consists of three kconsecutive steps` initial placement, iterative placement improvement, and string placement. In the initial placement step, cell placement was done by solving the linear ordering problem for a one-dimensional layout of standard cells and then zigzaging the resultant linear order width in the chip plane. The iterative placement improvement step is based on the iterative pairwise interchange using the estimated total routing length as a figure-or -merit. The string placement is used to reorder cells and terminals in each etandard cell row such that channel routing in the adjacent channels is not blocked by cyclic constraints and needs fewer routing tracks. The placement program is coded in PASCAL and kimplemented on a VAX-11/750 computer. Experimental results for several examples are included.

  • PDF

$3{\mu}m$ 설계 칫수의 이중금속 CMOS 기술을 이용한 표준셀 라이브러리 (A $3{\mu}m$ Standard Cell Library Implemented in Single Poly Double Metal CMOS Technology)

  • 박종훈;박춘성;김봉열;이문기
    • 대한전자공학회논문지
    • /
    • 제24권2호
    • /
    • pp.254-259
    • /
    • 1987
  • This paper describes the CMOS standard cell library implemented in double metal single poly gate process with 3\ulcornerm design rule, and its results of testing. This standard cell library contains total 33 cells of random logic gates, flip-flop gates and input/output buffers. All of cell was made to have the equal height of 98\ulcornerm, and width in multiple constant grid of 9 \ulcornerm. For cell data base, the electric characteristics of each cell is investigated and delay is characterized in terms of fanout. As the testing results of Ring Oscillator among the cell library, the average delay time for Inverter is 1.05 (ns), and the delay time due to channel routing metal is 0.65(ps)per unit length.

  • PDF

3차원 인체데이터에 의한 20대 성인남성 상반신 체표변화 분석 - 모터사이클복 패턴설계시 적용을 중심으로 - (Analysis of Body Surface Change from 3D Scan Data of Men's Upper Bodies in Twenties - Focus on Application of Motorcycle Jacket Pattern -)

  • 도월희
    • 한국의류학회지
    • /
    • 제32권4호
    • /
    • pp.530-541
    • /
    • 2008
  • The early stage of 3D anthropometry data has been used to obtain qualitative rather than quantitative information. However recent 3D body scanners as a common research tool for anthropormatric measurments have made it possible to obtain body surface data of sufficient resolution and accuracy. The purpose of this study is finally to develop motorcycle jacket for enhanced comfort and fit, to test the accuracy and reliability of 3D measurments of motorcycle riding posture, and to analyze the change in 20's adult male's body surface measurements between the standard anthropometric position and motorcycle riding posture. The results of this study were as follows: There were no significant differences between the study and Size Korea measurments in total traditional measuring items and most of measuring items, such as length, circumference antropometric items and interscye items though not waist back length and upper arm circumference. A comparison of 3D body surface measurments in the two different measuring postures, the bodysurface measurments such as waist front length, biacromion length, front interscye, arm length, underarm length in the motorcycle riding posture decreased than that in basic posture, whereas waist back length, back interscye, C.T.W length increased. The body surface measurments such as chest, bust, upper circumference in the motorcycle riding posture decreased than that in basic posture, whereas neck, waist, hip, elbow circumference increased.

전치부 치아동요에 관한 방사선학적 및 임상적 연구 (A RADIOGRAPHICAL AND CLINICAL STUDY OF ANTERIOR TOOTH MOBILITY)

  • 이광호;김병옥;한경윤
    • Journal of Periodontal and Implant Science
    • /
    • 제25권2호
    • /
    • pp.290-300
    • /
    • 1995
  • Tooth mobility is one of the most important clinical parameters in examination, diagnosis, prognosis and treatment planning procedure. In order to determine the differences of tooth mobility according to radiographical bone level, clinical root length, clinical crown/root ratio, and bleeding on probing, 90 male adults with periodontal disease and 10 male adults with periodontal health($25{\sim}45$ years old) were selected through clinical examinations including occlusal relationship, probing depth, attachment level, and bleeding on probing. On the mandibular anterior teeth, standard periapical radiographs were taken, and tooth mobility was measured by Periotest(Siemens Co., Germany). The radiographic bone level of individual tooth was evaluated as coronal 1/3, middle 1/3, and apical 1/3 to anatomical root length, and clinical crown length from incisal edge to bone level and clinical root length from bone level to root apex were measured with Boley gauge, and subsquently clinical crown/root ratio was calculated. The difference of tooth mobility(Periotest value) according to radiographical bone level, clinical root length, clinical crown/root ratio, and bleeding on probing was statistically analyzed by unpaired Student t-test. Tooth mobility was significantly higher in bleeding group than non-bleeding group on probing in the teeth radiographic bone level of middle 1/3, with clinical root length longer than 6mm, and with clinical crown/root ratio over 0.3(p<0.01). But there was no statistical difference in tooth mobility between bleeding group and non-bleeding group on probing in the teeth with radiographic bone level of apical 1/3, with short clinical root length less than 5mm, and with clinical crown/root ratio under 0.2(p>0.05). The results note that the tooth mobility depends on clinical root length, clinical crown/root ratio and gingival inflammation, and in the teeth with relatively good alveolar bone support gingival inflammation is one of the most important factors that affect tooth mobility.

  • PDF

미세단층촬영기(Micro-CT)를 이용한 전자 근관장 측정기의 정확성에 관한 연구 (A Study on the Accuracy of the Electronic Apex Locator Using a Micro-Computed Tomography)

  • 전경진;김양수;남태계
    • 한국정밀공학회지
    • /
    • 제24권8호통권197호
    • /
    • pp.116-121
    • /
    • 2007
  • The length of root canal has to be measured for endodontic treatment. Several electronic apex locators were developed to measure the length of root canal by other researchers. And their accuracies were verified by X-ray or micrometer method. But these methods did not consider the non-linear bends of pulp and had ${\pm}0.5mm$ error which was large enough to measure the length of root canal. The purpose of this study is the introduction of a new method to measure the length of root canal and the verification of the accuracy of an electronic apex locator using a Micro-CT. The length of root canal of 6 teeth were measured with the electronic apex locator. When the electronic apex locator reads 0.5, 0.6, 0.7, 0.8, 0.9 and 1.0 mm length of the file which was inserted in the hole of the tooth to measure the length of root canal. The average (${\pm}$Standard deviation) length of root canal of 6 teeth measured by the Micro-CT was $0.49{\pm}0.03,\;0.59{\pm}0.04,\;0.68{\pm}0.03,\;0.78{\pm}0.03,\;0.90{\pm}0.04\;and\;1.01{\pm}0.03mm$, respectively. The maximum error of the electronic apex locator was 0.06 mm.

중년 여성 이미지에 어울리는 패션 일러스트레이션에 대한 연구 -한국인 표준 체형을 중심으로- (A Study on Effective Fashion Illustration for Korean Middle Aged Woman -Focusing on the Standard Stomo type for Korean -)

  • 이운영;임순
    • 복식문화연구
    • /
    • 제7권3호
    • /
    • pp.134-141
    • /
    • 1999
  • The purpose of this study is to provide new style for fashion illustration fo different image of Korean middle aged women. The research method is as follows. First, we make basic style base on The Korea Industrial Advancement Administration\`s Korean standard stomatype. Second, it give variety to body\`s rate and make each different 8 style. The subject are 144 college students who majoring clothing, fashion design and they have responded to the questionnaires. Questionnaires were taken from April, 1998 to Jan. 1999. Data were analyzes by analysis of variance, ANOVA test, Dunkun test, SPSS. PC/sup +/. As a result of this study, we found this following conclusions, 1. Well-proportion style have the exaggerated shoulder and the extended body at the same rate below waist line than basic style. 2. Reduction and extension need stability and well balanced. 3. Fashion illustration of middle aged women\`s clothing expression is not proper too narrow width, too long length of legs. 4. To making length, it is award well-proportion have too long hand or too long arm.

  • PDF

기능적 Brassiere 개발에 관한 연구(II) - bust up 기능을 중심으로 - (Study on the Functional Brassiere Development)

  • 최혜선;강여선
    • 한국의류학회지
    • /
    • 제15권3호
    • /
    • pp.229-238
    • /
    • 1991
  • The object of this study is to develope an improved version of brassiere with better fit and improved performance by conducting a try-on test on 6 types of revised brassieres (constructed on above basis). The study procedures consisted of a try-on test of experimentally constructed brassieres and a sensory test on fit. The results of experimentally constructed brassiere trial are as follows. 1. The sizes showing performance effects due to different types of experimentally construct- ed brassieres were bust length, bust height, under bust curve length, vertical and horizontal bust diamenter, upper-lower bust slope angle (direct measurement, parallel standard, upper torso tilt rate), side bust slope angle and top bust slope angle. 2. Concerning the changes in lower cup interior, elastic materials and wider portions perfor-med better in bust up effect. 3. No effects due to different shoulder strap positions were observed, but combined with lower cup interior changes the side types proved more effective than the standard types.

  • PDF

선박용 벨로우즈의 형상최적화에 관한 연구 (A study on the shape optimization of ship's bellows)

  • 김종필;김현수;김형준;조우석;제승봉
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1303-1306
    • /
    • 2005
  • The mechanical properties of bellows, such as the extensibility and the strength can be changed depending on the shape. For the shipbuilding material, it is favorable that the fatigue life is long due to the elastic property and the reduction of thermal stress in piping system. Nowadays, the domestic production and design of bellows are based on the E.J.M.A Code. Therefore, the design standard is in need because of much errors and lack of detailed analysis. In this study, it is attempted to find out the optimal shape of U-type bellows using the finite element method. The effective factors, mountain height, length, thickness, and number of mountains and the length of joint are considered and the proper values are chosen for the simulation. The results shows that if the number of mountains are reduced, the volume decreases while the stress increases. However, the number of mountains are increased, the volume increases above the standard volume and the stress obviously increases. In addition, the effect of the thickness of bellows on the stress is very large. Both of the volume and stress are decreasing at a certain lower value region.

  • PDF

저전압동작에 적절한 SOI-like-bulk CMOS 구조에 관한 연구 (A Study on SOI-like-bulk CMOS Structure Operating in Low Voltage with Stability)

  • 손상희;진태
    • 한국전기전자재료학회논문지
    • /
    • 제11권6호
    • /
    • pp.428-435
    • /
    • 1998
  • SOI-like-bulk CMOS device is proposed, which having the advantages of SOI(Silicon On Insulator) and protects short channel effects efficiently with adding partial epitaxial process at standard CMOS process. SOI-like-bulk NMOS and PMOS with 0.25${\mu}{\textrm}{m}$ gate length have designed and optimized through analyzing the characteristics of these devices and applying again to the design of processes. The threshold voltages of the designed NMOS and PMOS are 0.3[V], -0.35[V] respectively and those have shown the stable characteristics under 1.5[V] gate and drain voltages. The leakage current of typical bulk-CMOS increase with shortening the channel length, but the proposed structures on this a study reduce the leakage current and improve the subthreshold characteristics at the same time. In addition, subthreshold swing value, S is 70.91[mV/decade] in SOI-like-bulk NMOS and 63.37[mV/ decade] SOI-like-bulk PMOS. And the characteristics of SOI-like-bulk CMOS are better than those of standard bulk CMOS. To validate the circuit application, CMOS inverter circuit has designed and transient & DC transfer characteristics are analyzed with mixed mode simulation.

  • PDF