• Title/Summary/Keyword: Lee Joon Gu

Search Result 328, Processing Time 0.027 seconds

Failure Analysis of Air Vent Connected with Heat Supply Pipeline Under Manhole (맨홀에 설치된 지역난방 열공급관 에어벤트의 전단부 파손 원인 규명)

  • Cho, Jeongmin;Chae, Hobyung;Kim, Heesan;Kim, Jung-Gu;Kim, Woo Cheol;Jeong, Joon Cheol;Lee, Soo Yeol
    • Corrosion Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.196-202
    • /
    • 2020
  • The air vent connected to a heat supply pipeline in the district heating system has been used to eliminate the existing air in the pipe, which has a detrimental effect on corrosion durability and heat efficiency. Recently, the air vent installed under a manhole for 22 years was corroded and several pinholes were detected in the front-end of the air vent. To identify the cause of the failure, thickness reduction, corrosion products, and water quality were examined. The corrosion damage was significant at the outside of the front-end of the air vent where the insulator was covered. While a thin oxide layer was formed in the interior of the tube, the coarse and porous corrosion products consisting of magnetite and hematite were found externally. Water flowing into the thermal insulator was absorbed by the insulator following hydrolysis. The hydrolyzed insulator ejected the corrosion factors such as Cl-, SO42-, and NH4+. The findings suggest that the corrosion under insulation due to rain water is the main cause of the underlying failure in the air vent.

Differential Stringent Responses of Streptomyces coelicolor M600 to Starvation of Specific Nutrients

  • Ryu, Yong-Gu;Kim, Eun-Sook;Kim, Dae-Wi;Kim, Sung-Keun;Lee, Kye-Joon
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.2
    • /
    • pp.305-312
    • /
    • 2007
  • This study focused on the involvement of the unusual nucleotide (p)ppGpp, a stringent factor, during the morphological and physiological differentiation of Streptomyces coelicolor. Two genes, relA and rshA, were disrupted to demonstrate the roles of the stringent factor in the differentiation. The intracellular concentration of (p)ppGpp in the wild-type (M600) and disrupted mutants was measured in relation to the intentional starvation of a specific nutrient, such as carbon, nitrogen, and phosphate or the in situ depletion of nutrients in a batch culture. As a result, it was found that the morphological characteristic of the ${\Delta}relA$ mutant was a bld phenotype forming condensed mycelia, whereas the ${\Delta}rshA$ mutant grew fast-forming spores and straightforward mycelia. In both mutants, the production of actinorhodin (Act) was completely abolished, yet the undecylprodigiosin (Red) production was increased. Intracellular (p)ppGpp was detected in the ${\Delta}relA$ mutant in the case of limited phosphate, yet not with limited carbon or nitrogen sources. In contrast, (p)ppGpp was produced in the ${\Delta}rshA$ mutant under limited carbon and nitrogen conditions. Therefore, (p)ppGpp in S. coelicolor was found to be selectively regulated by either the RelA or RshA protein, which was differentially expressed in response to the specific nutrient limitation. These results were also supported by the in situ ppGpp production during a batch culture. Furthermore, it is suggested that RelA and RshA are bifunctional proteins that possess the ability to both synthesize and hydrolyze (p)ppGpp.

A Study on the Chest Indirect Radiography (흉부X선 간접촬영의 촬영조건과 화질에 관한 조사연구)

  • Kim, Hark-Sung;Lee, In-Ja;Kim, Sung-Soo;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.11-19
    • /
    • 2003
  • chest Indirect radiography were taken at 44 medical facilities in Seoul area. The results were as follows: 1. The average tube voltage was 98.2 kVp in case of 100 mm film and 91.3 kVp in case of 70 mm film. 2. The average tube current was 18.1 mAs in case of 100 mm film and 42.5 mAs in case of 70 mm film. 3. In the physical evaluation of chest Indirect radiographs, the density in case of 100 mm film was similar to that in case of 70 mm film. 4. In the visual evaluation of chest Indirect radiographs, the score of identification in case of 100 mm film was higher than that in case of 70 mm film. 5. The average dose of radiation into the skin was 1.38 mGy in case of 100mm film and 4.59 mGy in case of 70 mm film. In conclusion, the image quality of chests was excellent and the dose of radiation into the skin decreased in case of 100 mm film.

  • PDF

Reduction of Scattered Radiation by Air Gap Technique for High Kilovoltage Chest Roentgenography (흉부(胸部) 고관전압(高管電壓) 촬영(撮影)에 있어 Air Gap Technique를 이용한 산란선(散亂線) 경감(輕減)에 관(關)한 연구(硏究))

  • Huh, Joon;Kim, Chang-Kyun;Kang, Hong-Seok;Youn, Chul-Ho;Lee, Sang-Suk;Lim, Han-Young;Song, Jae-Kwan
    • Journal of radiological science and technology
    • /
    • v.3 no.1
    • /
    • pp.57-66
    • /
    • 1980
  • X-ray grid is the most important means to reduce the scattered ray from patients, but alternative way is air gap technique that is another name of Groedel technique. This technique is mainly used in chest radiography. Authors performed an experimental study on the air gap technique for chest radiography and obtained the results as follows; 1. In using the high voltage air technique, scattered ray could be reduced effectively, while the percentage of scattered ray was slightly increased than conventional grid technique. 2. In film contrast, 30cm air gap technique was inferior to 12:1 grid technique and contrast improvement was increased when the object was thicker and higher voltage was used. 3. The patient exposure dose was reduced about $25{\sim}45%$ compared with conventional grid technique by air gap technique used.

  • PDF

Comparison of White Blood Cell Count, Erythrocyte Sedimentation Rate, and C-Reactive Protein for Diagnosis of Diabetic Foot Infection (당뇨발 감염진단을 위한 WBC, ESR, CRP의 유용성 비교)

  • Lee, Joon-Moon;Han, Seung-Kyu;Gu, Ja-Hea;Jung, Sung-Ho;Kim, Woo-Kyung
    • Archives of Plastic Surgery
    • /
    • v.37 no.4
    • /
    • pp.346-350
    • /
    • 2010
  • Purpose: Diagnosis of diabetic foot infection is sometimes difficult, since the classical inflammatory signs and leukocytosis may be absent due to the decreased host immune response in diabetics. Therefore inflammatory blood markers, such as white blood cell (WBC) count, erythrocyte sedimentation rate (ESR), and C-reactive protein (CRP) have been commonly needed to confirm the diagnosis of infection. The purpose of this study is to evaluate the diagnostic usefulness of WBC, ESR and CRP for detection of diabetic foot infection. Methods: Peripheral blood samples were taken from 113 patients with diabetic foot ulcers admitted from June 2007 to April 2009. Diabetic foot infection was diagnosed according to the microbiological culture from soft tissue and bone specimens. Reference values of tests were 4500-11000 /${\mu}L$ for WBC count, 0-20 mm/hr for ESR, and 0-5 mg/L for $CRP^{13,14}$. Sensitivities, specificities, positive and negative predictive values of laboratory tests were calculated and analysed. Receiver-operator characteristic (ROC) curve was also created. Results: There was a significant difference in WBC, ESR, and CRP between infectious group and noninfectious group (p<0.05). The sensitivity of WBC>11,000 /${\mu}L$ ESR > 20 mm/hr, and CRP > 5 mg/L was 30%, 96%, and 84%. The specificity was 86%, 14%, and 50% for WBC, ESR, and CRP, respectively. Positive predictive value was 88%, 78%, and 84%, and negative predictive value was 28%, 50%, and 50% respectively. The areas under the ROC curve for WBC, ESR and CRP were 0.72, 0.75, and 0.78 respectively. Conclusion: Based on the results of this study, we conclude that CRP is more useful method in predicting and diagnosing infection than WBC, ESR in diabetic foot ulcer patients.

Review on the location of SI11 (천종(天宗)(SI11)의 위치에 대한 고찰)

  • Choi, Joon-Soo;Lee, Byung-Ryul;Yang, Gi-Young;Yim, Yun-Kyung
    • Korean Journal of Acupuncture
    • /
    • v.27 no.1
    • /
    • pp.151-158
    • /
    • 2010
  • Objectives and Methods: The present study was performed to investigate acupuncture point location of SI11 through reviewing literatures. Results: 1. The first description of the location of SI11 appeared in "ChimGuGabEulGyong(ZhenjiuJiayiJing)", however the point description was not precise. 2. The first proportional measurement for SI11 showed up after Ching dynasty, which describes "SI11 is the point obliquely superiour 1.7 B-cun and transeversly interior to SI9" however this does not match the present WHO's standard location of SI11. 3. The WHO standard location of SI11 is in the scapular region, in the depression between the upper one third and lower two thirds of the line connecting the midpoint of the spine of the scapula with the inferior angle of the scapula, but there is no evidence to support this in classical literatures. 4. Based on myology and theories of meridian, we suggest that it is more reasonable to locate SI11 at the point in the depression between the upper two third and lower one thirds, not the upper one third and lower two thirds, of the line connecting the midpoint of the spine of the scapula with the inferior angle of the scapula. Conclusions: More studies are needed for the more reliable standard location of SI11.

Generation of a City Spatial Model using a Digital Map and Draft Maps for a 3D Noise Map (3차원 소음지도제작을 위한 도화원도와 수치지도를 이용한 도시공간모델 생성)

  • Oh, So-Jung;Lee, Im-Pyeong;Kim, Seong-Joon;Choi, Kyoung-Ah
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.2
    • /
    • pp.179-188
    • /
    • 2008
  • This study aims for generating a city spatial model required for the creation of a 3D noise map. In this study, we propose an efficient method to generate 3D models of the terrain and buildings using only a digital map and draft maps previously established without using any sensory data. The terrain model is generated by interpolating into a grid the elevation values derived from both the contour lines and the elevation point of the digital map. Building model is generated by combining the 2D building boundaries and the building elevations extracted from the digital map and the draft map, respectively. This method has been then applied to a digital map and three sets of draft maps created in the different times. covering the entire area of Yeongdeungpo-gu. The generated city spatial model has been successfully utilized for the noise analysis and the 3D visualization of the analysis results.

The Discharge Measurement System with River-Crossing Structures for Ecological Management during Low Flow Season (갈수생태관리를 위한 중소하천 횡단구조물에서 유량측정 시스템)

  • Lee, Nam-Joo;Kang, Joon-Gu;Yeo, Hong-Koo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.649-649
    • /
    • 2015
  • 최근 기후변화 및 이상기후로 인해 하천환경 또한 급격하게 변화되고 있다. 변화되는 지구환경에 대응하기 위해 하천환경 대책과 하천생태계 보전/복원, 생물 보호, 친수기능 강화를 요구하고 있는 실정이다. 더욱이 소하천 건천화 및 하천환경관리에 대한 중요성은 대두되고 있으나 비용 및 인력투입 문제로 수위나 유량 등의 기초자료인 수위-유량 계측기술 및 대응연구가 미미한 실정이다. 체계적인 하천관리를 위해서는 신뢰성 있는 대상 하천의 수리량 자료 확보가 기본으로 요구된다. 이러한 중소하천의 관리의 신뢰도를 높이기 위해서는 실시간 수위유량 자료 확보가 필수적이다. 현재 하천 정비 계획 단계에서 수문모델링을 통해 중소하천의 유량을 산정하고 있지만 산발적으로 측정한 자료로는 검/보정에 한계가 있으며, 신뢰도를 확보하기 어려운 실정이다. 이수, 환경, 생태 등의 관점에서는 평상시 유량에 대한 실시간 정보가 매우 중요하다. 이에 체계적인 하천관리를 위해서는 중소하천에 대한 실시간 수리량 자료를 경제적으로 확보 할 수 있는 장치 개발 및 현장적용이 시급하다. 본 연구에서는 하천 횡단구조물이 가지고 있는 유량 측정의 편이성을 최대한 이용하여 급성장하고 있는 영상분석기술과 IT을 하천공학분야에 접목하여 중소하천의 수위와 유량을 실시간으로 원격 측정하는 WIA (Wireless Image Acquisition) 시스템을 개발하였다. WIA 시스템은 라즈베리파이 기반으로 적외선카메라를 이용하여 일정한 시간간격으로 횡단구조물의 상류, 중류, 구조물 주위의 흐름 영상을 확보하여 중앙처리장치로 전송하는 시스템으로 구성된다. WIA 시스템에서 전송된 영상은 본 연구에서 개발한 영상판독 S/W 및 H-Q 산정 S/W를 통해 하천의 수위를 판독하고 실시간으로 하천단면 수위유량 산정 자료 구축하는 자료로 활용된다. 현재 WIA 시스템의 성능 및 개선과 영상판독 S/W 및 H-Q 산정 S/W서버와의 연계운영 성능 평가를 통해 장치를 검증하는 단계에 있으며, 추후 서버구축을 통해 홍수 예 경보와 하천수질관리를 위한 기초자료로 활용될 것으로 기대된다. 또한 본 연구에서 개발하는 유량측정 시스템을 적용하면 기존 장비의 약 15% 예산으로 실시간 수리량 자료를 확보할 수 있을 것으로 예상된다.

  • PDF

Anti-obesity Activity of Ethanol Extract from Bitter Melon in Mice Fed High-Fat Diet

  • Yoon, Nal Ae;Park, Juyeong;Jeong, Joo Yeon;Rashidova, Nilufar;Ryu, Jinhyun;Roh, Gu Seob;Kim, Hyun Joon;Cho, Gyeong Jae;Choi, Wan Sung;Lee, Dong Hoon;Kang, Sang Soo
    • Development and Reproduction
    • /
    • v.23 no.2
    • /
    • pp.129-138
    • /
    • 2019
  • In many cases, obesity is associated with metabolic disorders. Recently, natural compounds that may be beneficial for improving obesity have received increasing attention. Bitter melon has received attention as a diabetes treatment. $NAD^+$-dependent deacetylase (Sirtuin 1, SIRT1) has emerged as a novel therapeutic target for metabolic diseases. In this study, ethanol extract of bitter melon (BME) suppressed adipocyte differentiation and significantly increased the expression of SIRT1 in fully differentiated 3T3-L1 cells. Moreover, it enhanced the activation of AMP-activated protein kinase (AMPK). In high-fat diet (HFD)-fed induced-obesity mice, BME suppressed HFD-induced increases in body weight and white adipose tissue (WAT) weight. BME also increased the expression of SIRT1 and suppressed peroxisome proliferator-activated receptor and sterol regulatory element binding protein 1 expressions of WAT from HFD-fed mice. These findings suggest that BME prevents obesity by activating the SIRT1 and AMPK pathway and that it may be a useful dietary supplement for preventing obesity.

Velocity Fields in the vicinity of Step Weir (계단형 보 주변 유속장 분석)

  • Ryu, Yong Uk;Kang, Joon Gu;Yeo, Hong Koo;Lee, Nam Joo;Kim, Ji Hyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.454-454
    • /
    • 2016
  • 하천의 치수안정성 확보 및 수심유지, 생태복원 등과 같은 다양한 요구를 충족하기 위한 보의 성능 개선에 대한 연구가 필요하며, 계단형 보는 재료에 의한 폭기효과 및 서식처 효과 등의 환경적요소를 내포하고 있다. 기존 연구는 표면류 흐름특성을 검증하고 유량변화에 따른 하류단 도수발생위치 변화를 분석하는 등 계단형 보에 대해 수리특성을 정량화한 연구가 대부분이며 흐름변화에 따른 유속장에 관한 연구는 미흡한 실정이다. 따라서 본 연구는 기능성 친환경 횡단 구조물 유형 중 하나인 계단형 보의 안정성 검토를 위한 수리적 특성을 분석하고자 함으로써 구조물 안정성에 영향을 줄 수 있는 자체 및 하류 보호공 주변의 유속 분석을 통한 흐름 특성을 검토하고 설계시 외력 고려를 위한 자료를 제공하기 위한 목적이 있다. 이를 위해 계단형 보모형에 대해 수리모형실험을 수행하였다. 폭 0.24 m, 총 길이 3.70 m, 높이 0.30 m인 순환실험수로를 이용하였으며, 계단형 보 모형은 5단으로 단 높이 2 cm와 단 길이 5 cm이며, 보 높이는 10 cm, 보 길이는 25 cm 모형으로 실험하였다. 하류에 전도식 게이트를 설치하여 하류 수위를 증가시키면서 보 하류부에서 발생하는 완전도수부터 하류수심이 보 높이를 초과하는 잠김흐름 조건에 대해 실험하였다. 측정기법은 입자영상측정계(Particle Image Velocimetry; PIV)를 이용하였으며, 상류영역부터 하류영역에 대해 보 주변 흐름의 순간적 유속분포를 확인하였다. 또한 측정된 전반적 흐름 양상에 대해 통계적 수리분석을 수행하였다. 흐름특성에 대한 연구는 향후 계단형 보의 물받이 길이 및 보의 적정 규모 설계시 중요한 자료가 될 것으로 기대한다.

  • PDF