• Title/Summary/Keyword: Lee Joon Gu

Search Result 328, Processing Time 0.038 seconds

Prediction System of Deterioration Ratio for Marine Concrete Structures (해양콘크리트 구조물의 노후도 예측시스템 개발 연구)

  • Lee, Joon-Gu;Park, Kwang-Su;Cho, Young-Kwon;Lee, Chang-Su;Kim, Han-Joung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.531-534
    • /
    • 2005
  • The basic prediction model was constructed to obtain optimal maintenance method for concrete structure under marine environment by exploring the mechanism of mono and combined deterioration in lab. This model was planned to be upgraded with data acquired from several exposure specimens under same environment as structures. The computer program developed to give useful guidance observer would be improved. Several repair materials and repair construction methods applied to exposure specimens will be tested for its performance of prohibit salt attack and freezing & thawing action during experimental period about ten years. All of these data could be available to complete the prediction system. The manager will be able to use the system for optimal maintenance of marine concrete structures.

  • PDF

Effect of Prior Microstructures on the Behavior of Cementite and Mechanical Properties in Low Carbon Steels (저탄소강의 초기 미세조직에 따른 기계적 성질과 시멘타이트거동)

  • Lee, Jong-Chul;Kang, Ui-Gu;Lee, Jung-Won;Oh, Chang-Seok;Kim, Sung-Joon;Nam, Won-Jong
    • Transactions of Materials Processing
    • /
    • v.18 no.6
    • /
    • pp.471-475
    • /
    • 2009
  • The effect of prior microstructures on mechanical properties in low carbon steels were examined by comparing the behavior of cementite and mechanical properties of cryo-rolled and subsequently annealed steels. Prior microstructures consisted of ferrite + pearlite, banite or martensite. Steels, consisting of bainitic microstructure, exhibited the better combination of strength - ductility than steels with other prior microstructures, such as ferrite + pearlite and martensite.

Study of high-energy cosmic rays by measuring coincidence events with plastic scintillation detector arrays at Kyeonggibuk Science High School and Hansung Science High School

  • Lim, Sun-In;Lee, Yu-Ni;Nam, Shin-Woo;Park, Il-Heung;Yang, Jong-Mann;Cho, Wo-Ram;Cho, Il-Sung;Kwon, Young-Joon;Bang, Hyung-Chan;Cheon, Byung-Gu;Park, So-Hee;Jung, Eu-Gene;Go, Yu-Kyung;Kim, Bok-Yung;Lee, Su-Yang;Sim, Hyoung-Jun;Hong, Kyung-Hee
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.34 no.1
    • /
    • pp.188.2-188.2
    • /
    • 2009
  • PDF

X-Ray Exposure Reduction using Rare Earth Intensifying Screen for Chest Roentgenology (흉부(胸部) X선촬영(X線撮影)에 있어서 희토류증감지(稀土類增感紙) 사용(使用)에 따른 피폭선량(被曝線量) 경감(輕減)에 관한 검토(檢討))

  • Huh, Joon;Kim, Chang-Kyun;Kang, Hong-Seok;Lee, Sun-Sook;Song, Jae-Kwan;Lee, Sang-Suk
    • Journal of radiological science and technology
    • /
    • v.4 no.1
    • /
    • pp.23-30
    • /
    • 1981
  • In chest x-ray radiography, intensifying screen is used to the exposed dose of patients. Recently, newer materials-rere earth elements-are used in intensifying screen. Authors studied the aspects of chest x-ray radiogram and obtained the results that rare earth element intensifying screen did not harm in detail and could reduce the exposed dose of patient by 1/24 and below.

  • PDF

A Study on the Performance Evaluation and Use Status of Grid (격자의 성능평가와 이용실태에 관한 연구)

  • Lee, Who-Min;Kim, Hak-Sung;Lee, Sang-Suk;Oh, Hyun-Joo;Kim, Young-Il;Lim, Han-Young;Kim, Heung-Tae;Lee, In-Ja;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.17 no.1
    • /
    • pp.55-63
    • /
    • 1994
  • We have conducted on experiment with a purpose to evaluate the performance of grids being used at hospitals in Seoul and adjacent cities of Seoul. The results are as follows; Reality of the grids use 1. The focused grids were 105 and the parallel grids were 6 among 111 grids subject to experimenting. 2. The grid interspace material was aluminium of 94 and the remains were wood and bakelite. 3. The umber of Korean products from five companies was 33 and the one of the foreign products was 34 from companies. The physical properties have been examined by the notice of Department of Health and Social Affairs. 4. The intensity of secondary radiation was the highest in 5 : 1 grid ratio. 5. The Bucky factor increased with the increase of grid ratio. The selectivity, the grid improvement factor of grids also increased with increase of the grid ratio. However, with 6 : 1 grid ratio those factors were decreased exceptionally. In measurement of grid density with screen determiners and the beam alignment. 6. In evaluation the results were satifisfied within, 20%. 7. The value of the scale and the value of measurement were within the range of standard deviation, but the value of 103 lines were outranged from the standard deviation with all grid ratio except of 6 : 1 grid ratio.

  • PDF

Synthesis and Antiviral Activity of Novel Exomethylene Cyclopropyl Pyrimidine Nucleosides

  • Kook, Min-Chul;Kim, Gu;Kwak, Eun-Yee;Hong, Joon-Hee;Lee, Chong-Kyo;Choi, Bo-Gil
    • Archives of Pharmacal Research
    • /
    • v.25 no.6
    • /
    • pp.790-794
    • /
    • 2002
  • A series of novel exomethylene cyclopropyl nucleosides have been synthesized starting from Feist's acid. Classical nucleophilic substitution conditions ($K_2CO_3$, 18-crown-6) of the tosylate 2 as well as Mitsunobu reaction (DEAD, $PPh_3$) of alcohol 1 with pyrimidine bases afforded a series of novel cyclopropyl nucleosides. Compound 4b displayed moderate anti-HBV activity without any cytotoxicity up to $100{\;}{\mu}M$.

A Study on the Mix Design and the Control System of Thermal Crack for High Quality Mass Concrete (고품질 매스콘크리트 시공을 위한 배합설계 및 온도균열제어 시스템에 관한 연구)

  • Kim, Sun-Gu;Lee, Sang-Soo;Won, Cheol;Park, Sang-Joon;Kim, Dong-Seok
    • Journal of the Korea Institute of Building Construction
    • /
    • v.1 no.2
    • /
    • pp.174-178
    • /
    • 2001
  • This study was performed to control the thermal crack of the mat footing slab in the multi-purposed buildings. In this study, we executed the mixing design of concrete to satisfy the workability and the quality according to the site conditions. And, we evaluated quantitatively about the possibility of thermal crack by using hydration heat analysis system. Finally, we proposed the optimal mixing conditions, curing methods and curing period which all factors are considered. As a result, the optimal mixing conditions were : W/B 41%, unit binder 375kgf/$\textrm{m}^3$, FA replacement ratio 20%. Lowest thermal stress was 22.0kgf/$\textrm{cm}^2$ and at that time thermal crack index was over 1.5, when the coefficient of thermal conductivity was lowest among the curing conditions. And, the total curing time was estimated at 6.7 days according to curing steps.

  • PDF

A Survey on Patient Dose and Exposure Conditions in Simple Radiography of the Abdomen (복부 단순 X-선 촬영조건과 환자 피폭에 관한 조사 연구)

  • Kim, Sung-Soo;Lee, Sun-Sook;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.19 no.2
    • /
    • pp.59-65
    • /
    • 1996
  • We studied exposure techniques and exposure dose for simple abdomen A-P projection for 41 medical facilities that are located in Seoul area. 1. The range of tube voltage used was 60 to 84 kVp, the average tube voltage used was 74 kVp 2. Only 17% of added filter was used. 3. Tube current mostly used was 200 mA, some of them used 400 mA. 4. The grid ratio mostly was used 10 : 1, 54 % of the rare earth screen was used in most facilities. 5. The average skin entrance dose was 4.15 mSv and the dose range was 1.05 mSv to 11.0 mSv.

  • PDF

Corrosion of Steel Bars in Concrete at Joints under Tidal Environment (조수간만대 환경의 콘크리트 조인트에서 철근의 부식)

  • Lee, Joon-Gu;Park, Kwang-Su;Kim, Myung-Won;Kim, Kwan-Ho
    • Magazine of the Korea Concrete Institute
    • /
    • v.18 no.5 s.94
    • /
    • pp.73-82
    • /
    • 2006
  • 다양한 조인트를 갖도록 제작된 콘크리트 실험체내 철근의 부식에 대한 상세한 조사가 이루어졌다. 실험체들은 25년 동안 조수간만대에 노출되었다. 몇몇 실험체들은 25년 후에 가속챔버내에서 보다 가혹한 열화환경에 노출되었다. 실험항목은 부착강도, 중성화깊이, 염분농도, 부식의 전기화학적, 물리적 측정, 그리고 조인트부 생성물이다. 에폭시나 라텍스 페이스트로 처리된 조인트면을 제외하고 조인트면에 자동생성되는 생성물은 콘크리트 내 철근의 부식을 막는다. 철근과 콘크리트 계면에서의 공극은 국부부식의 주원인이다. 조인트 표면의 레이탄스 제거가 조인트면의 중성화 깊이를 줄인다. 레이턴스 제거 후 모르타르 코팅처리가 라텍스 페이스트나 에폭시코팅처리에 비해 가장 작은 중성화 깊이를 보인다. 레이턴스 제거후 에폭시코팅처리는 가장 강한 부착력을 갖지만 절점부 콘크리트 내 철근부식 방지에는 가장 우수한 성능을 보이지 못한다.

Measurement of Breaker Noise by Using Breaker Noise Measurement System (브레이커 소음측정시스템을 활용한 소음의 측정 및 평가)

  • Lee, Jae-Won;Kang, Dae-Joon;Gu, J.H.;Park, H.K.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1173-1176
    • /
    • 2007
  • The breaker noise is one of the main noise sources of construction site. It is very important to assess and measure the breaker noise accurately, because the noise labelling will be in effect January 2008 in Korea. Therefore, It is necessary to measure the sound power level of breakers and use a appropriate test method in accordance with international standard. In this study, we measure the sound power level of breakers by using the breaker noise measurement system. This system makes it possible to measure the breaker noise more accurately than to measure the noise of that attached with excavator, because this system can control main factors affecting breaker noise such as hydraulic input power, hydraulic supply pressure, breaker inlet oil flow and so on.

  • PDF