• Title/Summary/Keyword: Leakage risk

Search Result 424, Processing Time 0.031 seconds

An Access Control Method Based on a Synthesized Metric from Trust and Risk Factors for Online Social Networks (신뢰도와 위험도로부터 합성된 지표에 기반을 둔 온라인 소셜 네트워크를 위한 접근 제어 방법)

  • Seo, Yang-Jin;Han, Sang-Yong
    • The KIPS Transactions:PartC
    • /
    • v.17C no.1
    • /
    • pp.15-26
    • /
    • 2010
  • Social Networks such as 'Facebook' and 'Myspace' are regarded as useful tools for people to share interests and maintain or expand relationships with other people. However, they pose the risk that personal information can be exposed to other people without explicit permission from the information owner. Therefore, we need a solution for this problem. Although existing social network sites allow users to specify the exposing range or users who can access their personal information, this cannot be a practical solution because the information can still be revealed to third parties through the permitted users albeit unintentionally. Usually, people allow the access of unknown person to personal data in online social networks and this implies the possibility of information leakage. We could use an access control method based on trust value, but this has the limitation that it cannot reflect the quantitative risk of information leakage. As a solution to this problem, this paper proposes an access control method based on a synthesized metric from trust and risk factors. Our various experiments show that the risk of information leakage can play an important role in the access control of online social networks.

A Seasonal Risk Analysis and Damage Effects Assessment by Gas Leakage of Chemical Plant using 3D Scan and FLACS (3D 스캔과 FLACS를 활용한 화학플랜트 가스 누출의 계절별 위험성 및 피해영향 평가)

  • Kim, Jiyoung;Kim, Jiyu;Kim, Euisoo
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.4
    • /
    • pp.1-9
    • /
    • 2021
  • The process and facilities of modern chemical plants are becoming increasingly complex, there is possibility of potential risk. Internal chemicals generate stress concentration when operated due to turbulence, laminar flow, pressure, temperature, friction, etc. It causes cumulative fatigue damage, which can damage or rupture chemical facilities and devices. The statistics of chemical accidents found that the highest rate of occurrence was in summer, and in the last five years statistics on chemical accidents, leakage incidents make up a decent percentage of accidents. Chemical leaks can cause serious human damage and economic damage, including explosions and environmental pollution. In this study, based on the leak accident of chemical plant, the risk analysis, and damage effects assessment were estimated using a 3D scanner and FLACS. As a result, if chemicals leak in summer, the risk is higher than in other seasons, the seasonal safety management measures, and countermeasure were estimated.

A study on the development of SRI(Security Risk Indicator)-based monitoring system to prevent the leakage of personally identifiable information (개인정보 유출 방지를 위한 SRI(Security Risk Indicator) 기반 모니터링 시스템 개발)

  • Park, Sung-Ju;Lim, Jong-In
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.22 no.3
    • /
    • pp.637-644
    • /
    • 2012
  • In our current information focused society, information is regarded as a core asset and the leakage of customers' information has emerged as a critical issue, especially in financial companies. It is very likely that the technology that safeguards which is currently in commercial use is not focused at an enterprise level but is fragmented by function or by only guards portions of a customer's personal information. Therefore, It is necessary to study the systems which monitor the indicators of access at an enterprise level in order to preemptively prevent the compromise of such data. This study takes an enterprise perspective on such systems for a financial company. I will focus on examination of the methods of implementation of the monitoring system, the application of pattern analysis and examination of Security Risk Indicators (SRI). A trial of the monitoring system provided security managers and related departments with proper screening capabilities of information. Therefore, it is possible to establish a systemic counter-plans based on detectable patterns.

Cyber Risk Management of SMEs to Prevent Personal Information Leakage Accidents (개인정보유출 사고 방지를 위한 중소기업의 사이버 위험관리)

  • So, Byoung-Ki;Cheung, Chong-Soo
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.2
    • /
    • pp.375-390
    • /
    • 2021
  • Purpose: Most of cybersecurity breaches occur in SMEs. As the existing cybersecurity framework and certification system are mainly focused on financial and large companies, it is difficult for SMEs to utilize it due to lack of cybersecurity budget and manpower. So it is necessary to come up with measures to allow SMEs to voluntarily manage cyber risks. Method: After reviewing Cybersecurity market, cybersecurity items of financial institutions, cybersecurity framework comparison and cybersecurity incidents reported in the media, the criticality of cybersecurity items was analyzed through AHP analysis. And cybersecurity items of non-life insurers were also investigated and made a comparison between them. Result: Cyber risk management methods for SMEs were proposed for 20 major causes of cyber accidents. Conclusion: We hope that the cybersecurity risk assessment measures of SMEs in Korea will help them assess their risks when they sign up for cyber insurance, and that cyber risk assessment also needs to be linked to ERM standardization.

LPG 이송작업시 인적과오에 대한 사상수목분석

  • 김호영;김성영;임현교
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1998.05a
    • /
    • pp.277-284
    • /
    • 1998
  • LPG refueling include a lot of risk done by human beings, dealing with highly combustible gas, so, during the refueling, the leakage initiated by human errors can result in a catastrophic accident. Therefore, this research tried to show what kind of tasks would include the high probability of the human errors and what should be considered for effective safety management in the LPG refueling. At first, 4 typical cases were taken through surveying various accident cases, and then a prototype of the refueling task was presented. And each task was analysed by FTA and ETA. The results showed that overpressure occupies 64.64% of the major reasons for gas leakage, and its probability was approximately 6.62E-06. Among the tasks, gas leakage resulted from mal-assembly of lorry hoses had the highest rate, and human errors related to opening and closing valves of pipe lines were most frequent. Also, the effects of confirming tasks were analyzed quantitatively.

  • PDF

A Study on Explosive Hazardous Areas in Hydrogen Handling Facility (수소 취급설비의 폭발위험장소에 관한 연구)

  • PYO, DON-YOUNG;LIM, OCK-TAECK
    • Journal of Hydrogen and New Energy
    • /
    • v.30 no.1
    • /
    • pp.29-34
    • /
    • 2019
  • Safety of hydrogen handling facilities is needed as supply of hydrogen cars has been expanded recently. In this study, the adequacy of safety regulations of hydrogen handling facilities and the risk of damage with hydrogen leakage were studied. The range of explosion hazard location of the hydrogen filling plant was investigated using the computational fluid dynamics (CFD) method, Explosive hazardous area is influenced by leakage type, hole size and sectional area. When the conditions of KS standard are applied, range explosive hazardous area is expanded 7.05 m, maximum. It is about 7 times larger than exceptional standard of hydrogen station. Meanwhile, distance from leakage point to 25% LEL of hydrogen is investigated 1.6 m. Considering the shape of charging hose, regulation of hydrogen station is appropriate.

A Study on the Characteristics of the Work Safety Environment Sensing Module for LNG Storage Tanks (LNG 저장탱크용 작업안전 환경 센싱 모듈의 특성연구)

  • Park, Byong Jin;Kim, Min Sung
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.2
    • /
    • pp.189-196
    • /
    • 2022
  • We have developed an embedded based environment sensing module with high-resolution temperature, humidity and gas sensors to detect gas leakage under the condition of LNG injection. The developed sensing module have linearity with gas concentration. We have confirmed the developed sensing module could detect LNG gas concentration of 5 cmol/mol and 15 cmol/mol, which are gas concentration at risk of explosion. The response time of the developed module was fast within 8 seconds. Therefore it can be used to detect LNG gas leakage.

Development and Safety Evaluation of Earth Leakage Alarm Breaker Equipped with Fire Current (IGR) Alarming Function (화재전류(IGR) 경보 기능이 내장된 누전경보차단기의 개발 및 안전성 평가에 관한 연구)

  • Ko, Wan-Su;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.43-48
    • /
    • 2020
  • The purpose of this study is to develop an earth leakage alarm circuit breaker, equipped with a leakage alarming function (JER-E2S, ETECKOREA Co., Korea), and to analyze its characteristics. The developed mechanism is exclusively used for single-phase and 220 V circuits, with a rated current of 32 A, 20 A, 20 A (for restrooms), 16 A, etc. It satisfies all characteristics of existing earth leakage circuit breakers (ELB). If a fire current, which is a resistive leakage current (Igr), flows through an electric line, the device detects the leakage current in real time and warns against the leakage through a blinking LED lamp. Since the developed device displays a tolerance to a capacitative leakage current (Igc) that inevitably occurs in LED lamps, communication devices, etc., it ensures a stable power supply. In addition, the earth leakage alarm circuit breaker protects against power failure due to a momentary ground fault. Therefore, it can supply power without the risk of the circuit breaker malfunctioning due to a momentary ground fault caused by water droplets, leaves, etc. Moreover, with a standby power of less than 0.1 W, the developed earth leakage alarm circuit breaker exhibits a power saving performance that is 3~8 times greater than that of other ELBs. Installation of approximately 10 earth leakage alarm circuit breakers in one apartment household, with an area of 120 ㎡, can save 2~5 kWh per month. Therefore, the developed earth leakage alarm breaker not only satisfies the characteristics of existing earth leakage breakers, but also exhibits outstanding power supply quality since it has the functions of electric fire prevention and malfunction prevention. Therefore, this device can innovatively contribute to electric fire prevention.

The Study of Improvement of Personal Information Leakage Prevention in Mobile Environment (모바일 환경에서 개인정보 유출 방지를 위한 개선 연구)

  • Choi, Heesik;Cho, Yanghyun
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.11 no.3
    • /
    • pp.53-62
    • /
    • 2015
  • Recently, number of tablet or Smartphone users increased significantly in domestic and around the world. But violation of personal information such as leakage, misuse and abuse are constantly occurring by using mobile devices which is very useful in our society. Therefore, in this paper it will talk about the problems in the network environment of the mobile environment such as tablet and Smartphone, Mobile Malware, hacking of the public key certificate, which could be potential threat to mobile environment. This thesis will research for people to use their mobile devices more reliable and safer in mobile environment from invasion and leakage of personal information. In order to use Smartphone safely, users have to use Wi-Fi and Bluetooth carefully in the public area. This paper will research how to use App safely and characteristic of risk of worm and Malware spreading. Because of security vulnerabilities of the public key certificate, it will suggest new type of security certification. In order to prevent from the information leakage and infect from Malware in mobile environment without knowing, this thesis will analyze the improved way to manage and use the mobile device.

An Assessment on Effect of Facility and Electrical Safety During the Flooding of the Photovoltaic Power System (태양광 발전설비의 침수 시 설비영향 및 전기적 안전성 평가)

  • Park, Chan-Eom;Jung, Jin-Soo;Han, Un-Ki;Lim, Hyun-Sung;Song, Young-Sang
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.38-44
    • /
    • 2014
  • The photovoltaic power system is performing power generation by being installed in outdoors. Therefore it has the characteristics affected by environmental factors. In particular, if the solar power generation facility connected to the grid, the power can be generated continuously in a state of being secured operating voltage of the inverter and solar irradiation. In that case, if an abnormal situation such as flooding or heavy rains has occur, the possibility of electric shock or damage of facilities due to current leakage or a floating matters is present. In this paper, we performed electrical safety assessment about the connection part, junction box and cable of the solar module when the solar power system was flooded. we also assessed whether or not the leakage current is occurred in case of the cable was damaged. As a result, in case of the leakage current is large, we can be known that it is the risk of electric shock as well as cause of inverter damage.