• Title/Summary/Keyword: Leakage resonant inductance

검색결과 87건 처리시간 0.025초

A Hybrid DC/DC Converter for EV OBCs Using Full-bridge and Resonant Converters with a Single Transformer

  • Hassan, Najam ul;Kim, Yoon-Jae;Han, Byung-Moon;Lee, Jun-Young
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.11-19
    • /
    • 2017
  • This paper proposes a dc/dc converter for electric vehicle onboard chargers using a secondary resonant tank. To attain soft switching characteristics, such as zero voltage switching, magnetizing inductance has been used at the primary side of the transformer. The leakage inductance of the transformer is used as a resonant inductor on the secondary side to avoid the use of a separate inductor as resonance. The proposed converter is applicable for a wide load range. A 6.6KW prototype has been implemented for a wide range of load variations (250V, 330V, 360V, and 413V). A maximum efficiency of 97.4% is achieved at 413V.

Adaptive Synchronous Rectification Control Method for High Efficiency Resonant Converter

  • Kim, Joohoon;Moon, Sangcheol;Kim, Jintae
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.40-41
    • /
    • 2017
  • New adaptive SR (synchronous rectification) control method is proposed offering high efficiency in entire load conditions for resonant converters, in this paper. Unlike the conventional SR control method where turn-on time of the MOSFETs is varied depending on load conditions due to the stray inductance induced by a lead frame of MOSFET or PCB patterns, the proposed method automatically maintains a time interval between turn-off instance of a MOSFET and zero current instance of a body diode of the MOSFET as a predetermined time, in each switching cycle. Therefore, optimized turn-on time of the MOSFET can be achieved regardless of the leakage inductance. In this paper, the operational principle of proposed control method has been discussed. It has been tested on LLC resonant converter with 240 W to verify the proposed control method.

  • PDF

무접점 전원장치의 특성분석 (An Analysis on the Characteristics of the Contact-less Power Supply)

  • 이현관;이기식;정봉근;강성인;공영수;김은수;김윤호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.919-922
    • /
    • 2006
  • Comparing with the conventional transformer without the air gap, a contact-less transformer with the large air-gap (4.8cm) between the long primary winding and the secondary winding has the increased leakage inductance and the reduced magnetizing inductance. By the increased leakage inductance and the reduced magnetizing inductance on the primary of the contact-less transformer, a good deal of the primary current circulates through magnetizing inductance, which results in a massive loss in contact-less power supply (CPS). In this paper, the efficiency characteristics of the contact-less power supply using a series resonant converter is analyzed and simulated. The results are verified on the simulation based on the theoretical analysis and the 1.8kW experimental prototype.

  • PDF

코어없는 초박형 PCB 변압기를 이용한 무접점 전력변환 회로 (A Contactless Energy Transfer Circuit Using Coreless Low-profile PCB Transformer)

  • 최병조
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.505-508
    • /
    • 2000
  • A coreless printed circuit board(PCB) transformer is employed in a contactless energy transfer circuit that achieves an efficient power conversion at the presence of a considerable airgap between the source and the load side. A half-bridge series resonant converter is selected as the contactless energy transfer circuit in order to minimize the detrimental effects of large leakage inductance small magnetizing inductance and poor coupling coefficient of the coreless PCB transformer. The operation and performance of the proposed contactless power converter are verified on a 7 W experimental circuit that provides an 18V/0.4A output from a 210-370 V input source.

  • PDF

LLT 변압기 적용 LLC 직렬공진컨버터 동작특성 (Operating Characteristics of LLC Series Resonant Converter Using A LLT Transformer)

  • 이현관;허동영;이기식;정봉근;강성인;김은수
    • 전력전자학회논문지
    • /
    • 제11권5호
    • /
    • pp.409-416
    • /
    • 2006
  • LLT 변압기 적용 LLC 직렬공진컨버터의 동작특성에 대해 설명하였다. 본 논문에서는 1차측 권선과 2차측 권선을 분리하고, 변압기 중간에 공극(Air-Gap)을 삽입한 일체화된 LLT 변압기를 적용하였다. 이와 같이 적용된 LLT 변압기의 경우 1차측 누설인덕턴스만이 증가되는 것이 아니고 2차측 누설인덕턴스 또한 증가되게 된다. 이렇게 증가된 2차측 누설인덕턴스는 전압이득 특성곡선에 있어 LLC 직렬공진컨버터에 적용한 변압기를 사용한 경우보다 전체적으로 높은 전압이득 특성을 가지게 된다. 따라서 본 논문에서는 2차측 누설인덕턴스를 고려한 일체화된 LLT 변압기적용 LLC 직렬공진컨버터에 대해 이론적으로 해석하고 시뮬레이션 하였으며, 400W급 시제품을 제작하여 실험한 결과에 대해 서술하였다.

A Novel Quasi-Resonant Snubber-Assisted ZCS-PWM DC-DC Converter with High Frequency Link

  • Fathy, Khairy;Kwon, Soon-Kurl
    • Journal of Power Electronics
    • /
    • 제7권2호
    • /
    • pp.124-131
    • /
    • 2007
  • In this paper, a novel type of auxiliary switched capacitor assisted edge resonant soft switching PWM resonant DC-DC converter with two simple auxiliary commutation lossless inductor snubbers is presented. The operation principle of this converter is described using the switching mode equivalent circuits. This newly developed multi resonant DC-DC converter can regulate its DC output AC power under a principle of constant frequency edge-resonant soft switching commutation by an asymmetrical PWM duty cycle control scheme. The high frequency power regulation and actual power characteristics of the proposed soft switching PWM resonant DC-DC converter are evaluated and discussed. The operating performances of the newly proposed soft switching inverter are represented based on simulation results from an applications point of view.

High Step-up Active-Clamp Converter with an Input Current Doubler and a Symmetrical Switched-Capacitor Circuit

  • He, Liangzong;Zeng, Tao;Li, Tong;Liao, Yuxian;Zhou, Wei
    • Journal of Power Electronics
    • /
    • 제15권3호
    • /
    • pp.587-601
    • /
    • 2015
  • A high step-up dc-dc converter is proposed for photovoltaic power systems in this paper. The proposed converter consists of an input current doubler, a symmetrical switched-capacitor doubler and an active-clamp circuit. The input current doubler minimizes the input current ripple. The symmetrical switched-capacitor doubler is composed of two symmetrical quasi-resonant switched-capacitor circuits, which share the leakage inductance of the transformer as a resonant inductor. The rectifier diodes (switched-capacitor circuit) are turned off at the zero current switching (ZCS) condition, so that the reverse-recovery problem of the diodes is removed. In addition, the symmetrical structure results in an output voltage ripple reduction because the voltage ripples of the charge/pump capacitors cancel each other out. Meanwhile, the voltage stress of the rectifier diodes is clamped at half of the output voltage. In addition, the active-clamp circuit clamps the voltage surges of the switches and recycles the energy of the transformer leakage inductance. Furthermore, pulse-width modulation plus phase angle shift (PPAS) is employed to control the output voltage. The operation principle of the converter is analyzed and experimental results obtained from a 400W prototype are presented to validate the performance of the proposed converter.

High-Efficiency Non-contact Power Supply System

  • Zheng, Bin;Kwan, Dae-Hwan;Lee, Dae-Sik
    • 한국정보기술응용학회:학술대회논문집
    • /
    • 한국정보기술응용학회 2005년도 6th 2005 International Conference on Computers, Communications and System
    • /
    • pp.233-235
    • /
    • 2005
  • Non-contact power supply (NCPS), as a clean and safe energy supply concept has been applying wildly. Comparing with the conventional transformer the non-contact transformer has a large air gap between the long primary winding and the secondary winding. Due to it, the non-contact transformer has increased leakage inductance and reduced magnetizing inductance. So the high frequency series resonant converter has been widly used on the non-contact power supply system for transferring the primary power to the secondary one, from what a high influence voltage can be gained on the secondry coil even though the large air gap exists. However, it still has the disadvantages of the load sensitive voltage gain characteristics when load is changing. In this paper, we propose a fuzzy logic controller to adjust the frequency of the inverter to track the resonat which is changing when the load is change.

  • PDF

Numerical Analysis and Design of Moving Contactless High Power Transformer

  • Lee, Dong-Su;Jang, Dong-Uk;Kim, Hyung-Chul;Jung, Sang-Yong
    • Journal of Magnetics
    • /
    • 제16권4호
    • /
    • pp.423-426
    • /
    • 2011
  • This paper presents numerical analysis and design of high power contactless transformer with a large air-gap for moving on a guided linear track which is appropriate for high-speed train or MAGLEV. The system has the typical characteristics of large leakage inductance, small magnetizing inductance, and low coupling coefficients giving rise to lower power transfer efficiency, which have been compensated by the purposely-designed contactless transformer coupled with the resonant converter modulating with high switching frequency. In particular, the best model selected from the generated six design candidates has been applied for 3D Finite Element Analysis (FEA) investigating on iron loss to evaluate the overall system efficiency.

비접촉 충전을 위한 ZVS 다중공진 포워드 컨버터의 설계 (A Design of ZVS Multi-Resonant Forward Converter for Non-contact Charging)

  • 김영길;나희수;김진우;이성백
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1300-1302
    • /
    • 2000
  • In the charge system, a contact type-convenient-charging method is insufficient because of the contact failure around moist environment and troublesome question to put in and pull out. For the solution of this problem, an electromagnetically coupled non-contact charger for the rechargeable cell is proposed using ZVS multi-resonant forward converter. In this paper magnetizing inductance, leakage inductance and coupling coefficient, k are observed. By using the obserbed value, the proposed circuit is simulated by the PSPICE and implemented and the peak voltage of switch and output power are measured.

  • PDF