• Title/Summary/Keyword: Leakage energy

Search Result 721, Processing Time 0.039 seconds

Risk of Carbon Leakage and Border Carbon Adjustments under the Korean Emissions Trading Scheme

  • Oh, Kyungsoo
    • Journal of Korea Trade
    • /
    • v.26 no.2
    • /
    • pp.45-64
    • /
    • 2022
  • Purpose - This paper examines South Korea's potential status as a carbon leakage country, and the level of risk posed by the Korean emissions trading scheme (ETS) for Korean industries. The economic effects of border carbon adjustments (BCAs) to protect energy-intensive Korean industries in the process of achieving the carbon reduction target by 2030 through the Korean ETS are also analyzed. Design/methodology - First, using the Korean Input-Output (IO) table, this paper calculates the balance of emissions embodied in trade (BEET) and the pollution terms of trade (PTT) to determine Korean industries' carbon leakage status. Analyses of the risk level posed by carbon reduction policy implementation in international trade are conducted for some sectors by applying the EU criteria. Second, using a computable general equilibrium (CGE) model, three BCA scenarios, exemption regulations (EXE), reimbursement (REB), and tariff reduction (TAR) to protect the energy-intensive industries under the Korean ETS are addressed. Compared to the baseline scenario of achieving carbon reduction targets by 2030, the effects of BCAs on welfare, carbon leakage, outputs, and trading are analyzed. Findings - As Korea's industrial structure has been transitioning from a carbon importing to a carbon leaking country. The results indicate that some industrial sectors could face the risk of losing international competitiveness due to the Korean ETS. South Korea's industries are basically exposed to risk of carbon leakage because most industries have a trade intensity higher than 30%. This could be interpreted as disproving vulnerability to carbon leakage. Although the petroleum and coal sector is not in carbon leakage, according to BEET and PTT, the Korean ETS exposes this sector to a high risk of carbon leakage. Non-metallic minerals and iron and steel sectors are also exposed to a high risk of carbon leakage due to the increased burden of carbon reduction costs embodied in the Korean ETS, despite relatively low levels of trade intensity. BCAs are demonstrated to have an influential role in protecting energy-intensive industries while achieving the carbon reduction target by 2030. The EXE scenario has the greatest impact on mitigation of welfare losses and carbon leakage, and the TAF scenario causes a disturbance in the international trade market because of the pricing adjustment system. In reality, the EXE scenario, which implies completely exempting energy-intensive industries, could be difficult to implement due to various practical constraints, such as equity and reduction targets and other industries; therefore, the REB scenario presents the most realistic approach and appears to have an effect that could compensate for the burden of economic activities and emissions regulations in these industries. Originality/value - This paper confirms the vulnerability of the Korean industrial the risk of carbon leakage, demonstrating that some industrial sectors could be exposed to losing international competitiveness by implementing carbon reduction policies such as the Korean ETS. The contribution of this paper is the identification of proposed approaches to protect Korean industries in the process of achieving the 2030 reduction target by analyzing the effects of BCA scenarios using a CGE model.

Modeling negative and positive temperature dependence of the gate leakage current in GaN high-electron mobility transistors

  • Mao, Ling-Feng
    • ETRI Journal
    • /
    • v.44 no.3
    • /
    • pp.504-511
    • /
    • 2022
  • Monte Carlo simulations show that, as temperature increases, the average kinetic energy of channel electrons in a GaN transistor first decreases and then increases. According to the calculations, the relative energy change reaches 40%. This change leads to a reduced barrier height due to quantum coupling among the three-dimensional motions of channel electrons. Thus, an analysis and physical model of the gate leakage current that includes drift velocity is proposed. Numerical calculations show that the negative and positive temperature dependence of gate leakage currents decreases across the barrier as the field increases. They also demonstrate that source-drain voltage can have an effect of 1 to 2 orders of magnitude on the gate leakage current. The proposed model agrees well with the experimental results.

Feasibility study of β-ray detection system for small leakage from reactor coolant system

  • Jang, Jaeyeong;Jeong, Jae Young;Park, Junesic;Cho, Young-Sik;Pak, Kihong;Kim, Yong Kyun
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2748-2754
    • /
    • 2022
  • Because existing reactant coolant system (RCS) leakage detection mechanisms are insensitive to small leaks, a real-time, direct detection system with a detection threshold below 0.5 gpm·hr-1 was studied. A beta-ray detection system using a silicon detector with good energy resolution for beta rays and a low gamma-ray response was proposed. The detection performance in the leakage condition was evaluated through experiments and simulations. The concentration of 16N in the coolant corresponding to a coolant leakage of 0.5 gpm was calculated using the analytic method and ORIGEN-ARP. Based on the concentration of 16N and the measurement of the silicon detector with 90Sr/90Y, the beta-ray count rate was estimated using MCNPX. To evaluate the effect of gamma rays inside the containment building, the signal-to-noise ratio (SNR) was calculated. To evaluate the count rate ratio, the radiation field inside the containment building was simulated using MCNPX, and response evaluation experiments were performed using beta and gamma rays on the silicon detector. The expected beta-ray count rate at 0.5 gpm leakage was 7.26 × 105 counts/sec, and the signal-to-background count rate ratio exceeded 88 for a transport time of 10 s, demonstrating its suitability for operation inside a reactor containment building.

Airtightness of Light-Frame Wood Houses built in Daejeon and Chungnam Area

  • Jang, Sang-sik;Ha, Been
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.2
    • /
    • pp.147-158
    • /
    • 2017
  • Among the energy consumption in building, the heating energy takes the largest part. Therefore, it is important to minimize the heat energy loss in building for the reduction of overall energy use in construction. The most important points for the minimization of energy loss in building are insulation and airtightness. Especially, in wood houses, airtightness is very important for energy saving as well as increase of durability. However, the researches on airtightness of wood buildings have been started recently and are very deficient especially in Korea. In this study, air leakage properties and airtightness performance were evaluated for light-frame wood houses built in Daejeon and Chungnam area. Total 7 houses were evaluated, among which four houses (Case 1 to Case 4) were in the construction stage before interior finish and the other three houses (Case 5 to Case 7) were after completion of construction work. The tests for airtightness were conducted by pressurization-depressurization method, and the factors included in the measurements includes air leakage rate at 50 Pa (CMH50), air change rate at 50 Pa (ACH50), equivalent leakage area (EqLA) and EqLA per floor area. As a result of this study, key air leakage points in wood houses were found to be the gaps between floor and wall, the holes for wiring and plumbing, the double glasses windows and the entrance doors. The average value of ACH50 for the houses after completion of construction work was $3.5h^{-1}$ that was similar to Europe standard ($3.0h^{-1}$). ACH50 was proportional to EqLA per floor area but inversely proportional to the internal volume, the net floor area and the area of window.

Experimental Study on Airtightness Performance of the House with High Levels of Insulation and Airtight Construction (고기밀 고단열 주택의 기밀성능에 관한 실험적 연구)

  • Shin, U-Cheul;Yoon, Jong-Ho;Baek, Nam-Choon
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.4
    • /
    • pp.61-67
    • /
    • 2005
  • The purpose of this study is to evaluate the air tightness of Zero Energy Solar House(ZeSH) and to propose the construction improvement of junctions and penetrations where air infiltration was identified. Air leakage rate were measured by means of blower door test in accordance with ASTM E779-87. The results showed that ZeSH has an excellent airtightness with ACH50/20 (air change per hour at a pressure difference of 50 Pa between inside outside) of 0.34hr-1 and leakage class E by normalized leakage area of ASHRAE.

Leakage Energy Management Techniques via Shared L2 Cache Partitioning (캐시 파티션을 이용한 공유 2차 캐시 누설 에너지 관리 기법)

  • Kang, Hee-Joon;Kim, Hyun-Hee;Kim, Ji-Hong
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.37 no.1
    • /
    • pp.43-54
    • /
    • 2010
  • The existing timeout based cache leakage management techniques reduce the leakage energy consumption of the cache significantly by switching off the power supply to the inactive cache line. Since these techniques were mainly proposed for single-processor systems, their efficiency is reduced significantly in multiprocessor systems with a shared L2 cache because of the cache interferences among simultaneously executing tasks. In this paper, we propose a novel cache partition strategy which partitions the shared L2 cache considering the inactive cycles of the cache line. Furthermore, we propose the adaptive task-aware timeout management technique which considers the characteristics of each task and adapts the timeout dynamically. Experimental results from the simulation show that the proposed technique reduces the leakage energy consumption of the shared L2 cache by 73% for the 2-way CMP and 56% for the 4-way CMP on average compared to the existing representative leakage management technique, respectively.

Prediction of a Leakage in a Liquid Hydrogen Pump Using a Finite Element Method (유한요소 해석을 이용한 액화수소 펌프 누설량 예측)

  • HYUNSE KIM;YOUNG-BOG HAM
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.3
    • /
    • pp.292-296
    • /
    • 2023
  • Until recently, ships, automobiles, and drones using hydrogen energy are being actively researched. In addition, stations and facilities for hydrogen supply are being developed widely. Among them, a hydrogen pump is necessary for compressing it and transfer to other stations. The liquid hydrogen pump is operated at very high pressure up to 90 MPa. In our research, a reciprocating plunger pump is studied. Especially, a leakage in a liquid hydrogen pump is predicted using a finite element method. As a result, it was found that leak mass flow rates changed from 0.09 to 2.20 kg/h, when the gaps were given from 2 to 6 ㎛. Thus pump efficiencies were calculated from 99.9 to 97.9%, when the gaps changed from 2 to 6 ㎛. These results are useful for the design of the liquid hydrogen pump.

Leakage Current Energy Harvesting Application in a Photovoltaic (PV) Panel Transformerless Inverter System

  • Khan, Md. Noman Habib;Khan, Sheroz
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.4
    • /
    • pp.190-194
    • /
    • 2017
  • Present-day solar panels incorporate inverters as their core components. Switching devices driven by specialized power controllers are operated in a transformerless inverter topology. However, some challenges associated with this configuration include the absence of isolation, causing leakage currents to flow through various components toward ground. This inevitably causes power losses, often being also the primary reason for the power inverters' analog equipment failure. In this paper, various aspects of the leakage currents are studied using different circuit analysis methods. The primary objective is to convert the leakage current energy into a usable DC voltage source. The research is focused on harvesting the leakage currents for producing circa 1.1 V, derived from recently developed rectifier circuits, and driving a $200{\Omega}$ load with a power in the milliwatt range. Even though the output voltage level is low, the harvested power could be used for charging small batteries or capacitors, even driving light loads.

A Novel Recovery Circuit of a Leakage Inductance Stored Energy in Flyback Converter (플라이백 컨버터에서 누설인덕턴스 저장에너지의 새로운 회복회로)

  • Jung, Yong-Chae
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.526-528
    • /
    • 2005
  • Nowadays, more than ever before, many researchers are paying attention to raising the efficiency of a Power converter. In Flyback converter, the resistor of RCD snubber consumes the stored energy in leakage inductor. It play a role in degrading the overall system efficiency Thus, In this paper, a novel energy recovery circuit of Flyback converter is proposed to improve the efficiency. The operational principle of the proposed circuit is explained in detail. And, it is verified through the simulation results.

  • PDF