• Title/Summary/Keyword: Leakage Reduction

Search Result 483, Processing Time 0.038 seconds

PWM Control Method for DC link Voltage Balancing and Leakage Current Reduction in 3-level Inverter (3-레벨 인버터의 DC 링크 전압 밸런싱과 누설전류 저감을 위한 PWM 제어방법)

  • Choi, Nam-Sup;Lee, Eun-Chul;Ahn, Kang-Soon
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.137-138
    • /
    • 2015
  • 본 논문에서는 3-레벨 인버터 시스템의 DC 링크 전압 밸런싱과 동시에 공통모드 전압의 변동주파수를 최소화 하여 누설 전류를 저감하는 새로운 PWM 방법을 제안한다. 제안된 PWM은 공통모드전압과 중간점 제어능력에 따라 공간벡터를 분류하고 중간점 전압을 제어하면서 공통모드 전압의 변동이 최소화되는 벡터를 선택하도록 구성한다. 본 논문에서는 시뮬레이션을 통하여 제안된 PWM의 동작을 입증하였다.

  • PDF

A Study on the Factors Affecting the Influence Ranges of Ammonia Leakage by Using KORA Program (KORA 프로그램을 활용한 암모니아 누출사고 영향범위 결정 기여요인 연구)

  • Lim, Hyeongjun;Kwak, Sollim;Jung, Jinhee;Ryu, Taekwon;Choi, Woosoo;Lee, Jieun;Lee, Jinseon;Lee, Yeonhee;Kim, Jungkon;Yoon, Junheon;Ryu, Jisung
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.3
    • /
    • pp.38-44
    • /
    • 2018
  • Ammonia is used primarily as a refrigerant in refrigeration facility and SCR of a plant, and is frequently involved in leakage accidents. This study was conducted by selecting ammonia, a material with a wide influence range when evaluated, as a material with higher vapor pressure and lighter than air. In this study, the influence ranges were computed using KORA(Korea Off-site Risk Assessment supporting tool) with four different environmental factors : ground roughness, sealing, operating temperature, pressure, and leakage hole size. As a result, the difference in the influence range of ground roughness is approximately 4.62 times, while the ammonia storage tank shows a difference in the reduction rate of 0.64 when sealed. The extent of impact increased with increasing leakage depending on storage temperature and pressure, and when storing higher than the saturation vapor pressure, the impact range showed an average growth rate of 3.45 % per 0.1 Mpa($45^{\circ}C$). The influence ranges based on the size of the leakage holes is shown to be proportional to the area of the leakage zone.

Flicker Prevention and Noise Reduction Using Edge-Spike Modulation in Visible Light Communication

  • Lee, Seong-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.143-149
    • /
    • 2018
  • In this paper, we introduce an edge-spike modulation method for visible light communication (VLC). This method is effective in preventing LED flicker and 120 Hz noise interference in base-band VLC. In the VLC transmitter, edge-spikes are generated by passing the digital data through a simple RC-high pass filter (HPF). The LED modulation of the edge-spikes does not change the average power of the LED light; thus it prevents LED flicker. In the VLC receiver, the 120 Hz noise from other lighting lamps is easily eliminated by RC-HPF, while the edge-spike signal is detected normally. In our experiment, the message of an air-quality sensor was successfully transmitted using edge-spike modulation. This structure is useful in constructing, e.g., wireless gas monitoring sensor systems to warn and prevent harmful gas leakage accidents in buildings using LED light.

Output Inductor Less Phase Shift Full Bridge Converter with Current Stress Reduction Technique for Server Power Application

  • Lee, Woo-Jin;Park, Ki-Bum;Heo, Tae-Won;Moon, Gun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.502-504
    • /
    • 2008
  • A new output inductor less phase shift full bridge converter with current reduction technique for server power application is proposed in this paper. The proposed converter can reduce the current stress by using the auxiliary circuit. Since the auxiliary circuit causes the additional resonance between the leakage inductor and auxiliary capacitor before the powering period, the proposed converter has lower current stress even no output filter inductor. Small size and circulating energy can be also the merits of the proposed converter. The operational principles and analysis are presented. Experimental results demonstrate that the current stress can be reduced effectively by using the auxiliary circuit without large output filter inductor.

  • PDF

Measurement error reduction technique for the Semiconductor Device DC Characteristic Measurement System (반도체 소자의 직류특성 측정 시스템에서의 저전류 측정 오차 감소 기법)

  • Choi, In-Kyu;Jung, Hae-Yone;Park, Jong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.352-355
    • /
    • 2001
  • In this paper, we proposed measurement error reduction technique for the semiconductor device DC characteristic measurement system. Implemented system is composed of 4 SMUs, 2 VSUs, and 2 VMUs. Various efforts in hardware and software have been made to reduce the measurement errors due to the leakage current in measurement circuits. Internal and external sources of errors in measurement system especially in pA range measurement have been identified and removed. Experimental results show that the implemented system can be measure the DC characteristic of semiconductor devices in pA level.

  • PDF

5-MeV Proton-irradiation characteristics of AlGaN/GaN - on-Si HEMTs with various Schottky metal gates

  • Cho, Heehyeong;Kim, Hyungtak
    • Journal of IKEEE
    • /
    • v.22 no.2
    • /
    • pp.484-487
    • /
    • 2018
  • 5 MeV proton-irradiation with total dose of $10^{15}/cm^2$ was performed on AlGaN/GaN-on-Si high electron mobility transistors (HEMTs) with various gate metals including Ni, TaN, W, and TiN to investigate the degradation characteristics. The positive shift of pinch-off voltage and the reduction of on-current were observed from irradiated HEMTs regardless of a type of gate materials. Hall and transmission line measurements revealed the reduction of carrier mobility and sheet charge concentration due to displacement damage by proton irradiation. The shift of pinch-off voltage was dependent on Schottky barrier heights of gate metals. Gate leakage and capacitance-voltage characteristics did not show any significant degradation demonstrating the superior radiation hardness of Schottky gate contacts on GaN.

Spontaneous Vertebral Reduction during the Procedure of Kyphoplasty in a Patient with Kummell's Disease

  • Hur, Won-Seok;Choi, Sang-Sik;Lee, Mi-Kyoung;Lee, Dong-Kyu;Lee, Jae-Jin;Kim, Kyong-Jong
    • The Korean Journal of Pain
    • /
    • v.24 no.4
    • /
    • pp.231-234
    • /
    • 2011
  • Kummell's disease is a spinal disorder characterized by delayed post-traumatic collapse of a vertebral body with avascular necrosis. Although definitive treatment for Kummell's disease has not been established, it has been reported that percutaneous vertebroplasty or kyphoplasty has shown good results. However, these procedures are not recommended for severely collapsed vertebral bodies because of the risk of cement leakage or technical difficulties. Authors report a rare case of spontaneous reduction in vertebral height by the insertion of a working cannula into the vertebral body in Kummell's disease.

Lubrication Characteristics of Surface Textured Hydraulic Machine Components (표면조직 가공한 유압부품면에서의 윤활특성)

  • Lee, J.O.;Park, T.J.
    • Journal of Drive and Control
    • /
    • v.9 no.4
    • /
    • pp.26-31
    • /
    • 2012
  • Friction reduction between sliding hydraulic machine components is required to improve efficiency and reliability of hydraulic machineries. It is recently reported that surface texturing on sliding bearing surfaces can reduce the friction force highly. In this paper, numerical analysis is carried out to investigate the effect of dimple numbers and inlet boundary pressures on the lubrication characteristics of a parallel sliding bearing using a commercial computational fluid dynamics (CFD) code, FLUENT. The results show that the pressure distribution, load capacity, dimensionless friction force and leakage with dimple number and their locations, and inlet pressures. The overall lubrication characteristics are highly affected by dimple numbers and boundary pressure. The numerical method adopted and results can be used in design of efficient hydraulic machine components.

A Switching Method of Single Phase Grid Connected Inverter for Common Mode Noise Reduction (계통연계형 단상인버터의 Common Mode Noise 저감을 위한 Switching 방법)

  • Lee, Seung-Ju;Hong, Chang-Pyo;Kim, Hag-Wone;Cho, Kwan-Yuhl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.1
    • /
    • pp.27-33
    • /
    • 2016
  • A pulse-width modulation (PWM) method for common mode noise reduction in a PWM inverter connected to a single-phase grid is proposed in this study. The extensively used conventional switching method may experience common mode voltage problems, which generate current leakage and electromagnetic induction problems. In the proposed switching method, the neutral point of the output voltage is always fixed at both ends of the input voltage to reduce common mode noise. The validity of the proposed method is proven through simulation and experimental results.

Development of optimal operation of water distribution system for energy recovery and leakage reduction (에너지회수 및 누수감소를 위한 상수도시스템 최적 운영기술 개발)

  • Hui Geun Kwon;Min Jun Kim;Ryul Kim;Young Hwan Choi
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.425-425
    • /
    • 2023
  • 상수도시스템의 지속가능한 운영을 위해서는 에너지를 효율적으로 활용하는 것이 필수적이다. 따라서, 본 연구에서는 상수도시스템에서 고압구간의 압력조절을 통해 에너지 측면의 최적 운영기법을 제안하였다. 제안된 최적 운영기법은 마이크로 터빈을 이용하여 에너지 회수를 통한 압력저하와 이로 인한 누수량 저감을 동시에 고려하였다. 본 연구에서 사용한 최적화기법으로는 Multi-objective harmony search 알고리즘을 사용하였으며, 상수도 시스템에서 마이크로 터빈을 모의하기 위해서 EPANET의 압력조절 밸브 (Pressure reduction valve)를 활용하여 압력강하에 따른 에너지 회수를 고려하였다. 제안된 최적운영 기법을 검증하기 위해 Benchmark networks (e.g., 5-nodes network, 25-nodes network)을 적용하였으며, 본 연구를 통해 마이크로 터빈의 최적 규모와 설치위치, 개수를 결정할 수 있으며, 이에 따른 에너지 회수와 누수감소 측면에서 상수도시스템의 지속가능한 운영에 효과적으로 이용될 수 있을 거라 기대된다.

  • PDF