• Title/Summary/Keyword: Leakage Dose

Search Result 149, Processing Time 0.021 seconds

Evaluation of Radiation Doses of Dental Portable Equipment (치과용 이동형 방사선장치의 선량평가)

  • Park, Hoon-Hee;Kang, Byung-Sam
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.445-450
    • /
    • 2018
  • We aim to evaluate safety of radiation by measuring leakage dose and patient(phantom) incident dose of ZEN-PX II dental portable equipment developed by G company. Measurement for leakage dose of equipment is conducted on the top, at the bottom, on the left, on the right and at the back. Dose measurement incident on the subject with the area dosimeter when using the phantom and measurement the leakage dose of equipment when using the phantom are evaluated. Comparing the right with the highest leakage dose as a 0 cm, 25 cm, 50 cm, 75 cm and 100 cm dose measurement at the measurement height of 100 cm, 64.2 uR was reduced to 47.3 uR in the senser mode 0.32sec. Even in film mode it was measured at 414.4 uR and about 27% lower at 162.6 uR. As the result of this study, when the irradiation time is 2 sec the right side dose is 290.5 uR and sensor mode is 0.32 sec the right side dose is 64.2 uR.

Low-dose radiation therapy for massive chylous leakage after subtotal gastrectomy

  • Kim, Sang-Won;Kim, Jung Hoon
    • Radiation Oncology Journal
    • /
    • v.35 no.4
    • /
    • pp.380-384
    • /
    • 2017
  • Massive chylous leakage is a rare postoperative complication that can prolong hospital stay and cause secondary morbidities. Conservative management strategies are the treatment of choice; however, radiation therapy (RT) can be used as an alternative for cases that are refractory to conservative treatment. Herein, we report a 69-year-old female patient who suffered from massive chylous leakage after subtotal gastrectomy. Due to persistent massive chylous leakage, she was scheduled to undergo low-dose RT. Radiation was delivered with a daily dose of 1 Gy, using an anterior-posterior and posterior-anterior beam arrangement. The clinical target volume encompassed the entire lymph node area of the D2 dissection. RT was completed at the total dose of 8 Gy because the amount of chylous leakage declined rapidly. Percutaneous drainage tube was removed after 3 days of RT. The patient did not complain of any symptoms related to massive chylous leakage 2 years after the completion of RT.

Measurement from Moving Vehicle Health Screening Outside of The Leakage Dose (이동건강검진차량에서 외부의 누설선량 측정)

  • Han, Beom-Hee;Han, Sang-Hyun;Mo, Eun-Hee;Kim, Chong-Yeal
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.3
    • /
    • pp.192-198
    • /
    • 2015
  • Checked out by the moving vehicle health checks for patients, practitioners, and the increase in radiation dose outside the vehicle, but an investigation into the leakage of radiation can still be negligible. In this study, through experimental results were as follows: Dose that occurs most often where the leak in the right door $1.14{\pm}1.75mR/h$, X-ray generator in terms of proximity to the top $0.65{\pm}1.25mR/h$, X-ray generator and away to the bottom in terms $0.91{\pm}1.25mR/h$, the adjacent rear detector in the upper part $96.98{\pm}158.88mR/h$ dose of the leak appeared in various locations. By measuring position from the rear of the adjacent detector $67.48{\pm}97.03mR/h$ dose had the highest leakage into. Generating device for diagnosis of radiation safety regulations regarding the maximum leakage dose per week, but all met back when it is displayed in the leakage dose Hourly rates do not ignore the leakage radiation dose were measured. Therefore, a mobile health screening in a vehicle outside of the leakage radiation dose to the liver and move on we are not interested twelve barrier leakage radiation dose of defense has a chance to re-evaluate the standards required, and move the vehicle health check using the X-ray increases as the dose per hour, depending on the criteria for choosing the appropriate measures that will require effort.

Tip Leakage Flow on the Transonic Compressor Rotor (천음속 회전익에서의 누설유동)

  • Park, JunYoung;Chung, HeeTaeg;Baek, JeHyun
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.244-249
    • /
    • 2002
  • It is known that tip clearance flows reduce the pressure rin, flow range and efficiency of the turbomachinery. So, the clear understanding about flow fields in the tip region is needed to efficiently design the turbomachinery. The Navier-Stokes code with the proper treatment of the boundary conditions has been developed to analyze the three-dimensional steady viscous flow fields in the transonic rotating blades and a numerical study has been conducted to investigate the detail flow physics in the tip region of transonic rotor, NASA Rotor 67. The computational results in the tip region of transonic rotors show the leakage vortices, leakage flow from pressure side to suction side and their interaction with a shock Depending on the operating conditions, the position of shock-wave on the blade surface are v8y different close to the blade tip of the transonic compressor rotor. The shock-wave position dose to the blade tip had the dose relationship with the starting position of leakage vortex and the direction of leakage flow.

  • PDF

Leakage and scattered radiation from hand-held dental x-ray unit (이동용 치과 X선 발생장치의 누설 및 산란 선량에 관한 연구)

  • Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.37 no.2
    • /
    • pp.65-68
    • /
    • 2007
  • Purpose: To compare the leakage and scattered radiation from hand-held dental X-ray unit with radiation from fixed dental X-ray unit. Materials and Methods: For evaluation we used one hand-held dental X-ray unit and Oramatic 558 (Trophy Radiologie, France), a fixed dental X-ray unit. Doses were measured with Unfors Multi-O-Meter 512L at the right and left hand levels of X-ray tube head part for the scattered and leakage radiation when human skull DXTTR III was exposed to both dental X-ray units. And for the leakage radiation only, doses were measured at the immediately right, left, superior and posterior side of the tube head part when air was exposed. Exposure parameters of handheld dental X-ray unit were 70 kVp, 3 mA, 0.1 second, and of fixed X-ray unit 70 kVp, 8 mA, 0.45 second. Results: The mean dose at the hand level when human skull DXTTR III was exposed with portable X-ray unit $6.39{\mu}Gy$, and the mean dose with fixed X-ray unit $3.03{\mu}Gy$ (p<0.001). The mean dose at the immediate side of the tube head part when air was exposed with portable X-ray unit was $2.97{\mu}Gy$ and with fixed X-ray unit the mean dose was $0.68{\mu}Gy$ (p<0.01). Conclusions: The leakage and scattered radiation from hand-held dental radiography was greater than from fixed dental radiography.

  • PDF

Radiation Safety Exploration Using Radio-photoluminescence Dosimeter for Crookes Tubes in Junior and Senior High School in Japan

  • Akiyoshi, Masafumi;Do, Duy Khiem;Yamaguchi, Ichiro;Kakefu, Tomohisa;Miyakawa, Toshiharu
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.3
    • /
    • pp.106-111
    • /
    • 2021
  • Background: Crookes tube is utilized in junior high and high schools in Japan to study the character of electrons and current, and not for radiological education. There is no official guideline or regulation for these radiation source to the public. Therefore, most teachers have no information about the leakage of X-rays from Crookes tube. The peak energy of X-rays is approximately 20 keV, and it is impossible to measure using conventional survey meters. Materials and Methods: Each leakage dose of low energy X-rays from 38 Crookes tube in the education field, such as junior and senior high schools in Japan, was explored by the teachers in the school using radio-photoluminescence (RPL) dosimeters. Before and after the measurements, the dosimeters were sent by postal mails. Results and Discussion: At the exploration in this study, it was estimated that the 70 ㎛ dose equivalent, Hp(0.07) of X-rays from 31 Crookes tubes were smaller than 100 µSv in 10 minutes, at the distance of 1 m, where the Crookes tube was usually observed. However, the highest dose was estimated as 0.69 mSv by an equipment with the full power. Furthermore, one Crookes tube exhibited 0.62 mSv with minimum output power of the induction coil. This relatively large dose was reduced by the shorter distance of discharge electrodes of the induction coil. Conclusion: The leakage dose of low energy X-rays from 38 Crookes tube was explored using RPL dosimeters. It was estimated that the Hp(0.07) of X-rays from 31 Crookes tubes were smaller than 100 µSv in 10 minutes at the distance of 1 m, while some equipment radiated a higher dose. With this study, the provisional guideline for the safety operation of Crookes tube is established.

Studies on the cellular metabolism in microorganisms as influenced by gamma-irradiation.(V) "On the membrane permeability changes and leakage of celluar constituents of irradiated yeast cell" (미생물의 세포생리에 미치는 전이방사선의 영향에 관한 연구 (제 5 ) "-의 과성에 대한 $\gamma$-의 영향에 대하여")

  • 김종협;전세열;김희자
    • Korean Journal of Microbiology
    • /
    • v.6 no.2
    • /
    • pp.54-62
    • /
    • 1968
  • The effect of gamma-ray on yeast cells Sacch. cerevisiae, and the leakage of cellular constituents such as carbohydrates, ribose, amino acids, inorganic phosphates and organic phosphates have been studied. The samples of yeast cells washed throughly and starved intensively, radiation effects were compared with those of control (un-starved), the irradiation dose rates are in the range from 24 Kr. up. to 480, Kr. The loss of 260m$\mu$. absorbing material, are also observed. Mechanisms of membrane damage by gamma-irradiation are discussed corelating to permeability changes and loss of substances, then active and passive transport process are also under considerations in discussion. The experimental results are as follows, 1. Carbohydrates of yeast cell leak out by gamma-irradiation, and amounts of loss increase proportionally as the increasing of radiation dose, curve of carbohydrates loss in starved cells is parallel with those of non-starved cells. 2. Ribose leak out less than that of carbohydrate from irradiated cell, the dose response curve of loss is straight and proportional to the increasing of radiation doses, slope of the curve is much lower than of carbohydrates. 3. Amino acids also leak out and the curve of losses to radiation is not proportional, it is revealed that there are little losses from yeast at lower doses of irradiation. 4. The losses of inorganic phosphates increase unproportionally to the increasing of irradiation doses, there are little leakage at the lower doses of irradiation. The losses of organic phosphates increase proportionally to the increasing of irradiation doses, and the amount of losses are much more than that of inorganic phosphate at lower doses of irradiation. 5. Leakage from irradiated yeast cells was shown to be due to passive transport process not an energy requiring process of ion transport. 6. Loss of 260 m$\mu$. absorbing material is little more than that of control yeast by the gamma-irradiation dose of 120K.r. and 240K.r.

  • PDF

Leakage and Scattered Radiation from X-ray Unit in Radiography (영상의학과 엑스선 발생장치의 누설 및 산란선량 측정)

  • Im, In-Chul;Lee, Jae-Seung;Kweon, Dae-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.155-159
    • /
    • 2011
  • The purposed of this study were measured the radiation exposure of patients and workers by generators, and the protection state for radiation facilities. The subject of the study by X-ray generators in university hospitals of capital area, we measured the maximum irradiation condition of 80 kVp, 200 mA, 0.1 second in the control entrance, control room window, entrance of radiography, adjacent site. The leakage dose per week was which the control entrance was 0.11 mR/week, control room window was 0.15 mR/week, entrance of radiography was 0.12 mR/week and adjacent site was 0.06 mR/week with X-ray unit the mean And the leakage mean dose was 0.11 mR/week. Diagnostic X-ray tubes must ensure that the leakage radiation in the maximum leakage dose in week emitted by the tube outside the useful beam does not exceed certain levels provided by standards.

Development and utility evaluation of new Multi-Leaf Collimator for Diagnostic X-ray Equipment

  • Ji, Hoon;Han, Su Chul;Baek, Jong Hyeun;Lee, Dong Hoon;Park, Seungwoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.936-942
    • /
    • 2018
  • The diagnostic multi-leaf collimator preventing unnecessary dose from entering into patients during the diagnostic examination was made in this study. The movement of the entire 50 leaves was embodied with the group of 25 ones thereof configured in a pair facing each other on the left and right of the median line. Dimensions of the length, width, and height of each shielding leaf were $5{\times}0.5{\times}0.5cm^3$ resulting in the maximum boost field of $10{\times}10cm^2$. The material of multi-leaf collimator had the excellence on the machinability with the use of the SKD-11 alloy tool steel having the high wear resistance against frequent movement, and it was devised to control both-side's shielding leaves by moving 2 motors unlike existing remedial multi-leaf collimator that use as many motors as the number of 50 shielding leaves. Thereafter, the transmission dose of leaves, cross-leaf leakage dose, and inter-leaf leakage dose were measured by the developed multi-leaf collimator attached to X-ray equipment. An ionization chamber was used to detect doses there from, and the comparative analysis was carried out by means of the radiographic film that was easy to detect the dose leakage in between each leaf. Results obtained from the test conducted in comparative analysis yielded approximately 98%, 96%, and 94% of shielding efficiency realized at each level of energy of 80kV, 100kV, and 120kV it was confirmed there was no dose leakage resulted from the varied level of irradiation energy. Thus the multi-leaf collimator to be developed based on this study is thought that it could fully reduce the unnecessary dose to patients in the diagnostic test and the shielding efficiency thereof is expected to be increasing if it is made in a miniaturized form with a way of increasing the thickness of each leaf later for an extended application to general diagnostic purposes.

Effect of Scatter ray in Outside Telecobalt-60 Field Size (코발트-60 조사야 밖의 장기에 미치는 2차선의 영향)

  • Kim, You-Hyun;Kim, Young-Whan
    • Journal of radiological science and technology
    • /
    • v.11 no.2
    • /
    • pp.65-71
    • /
    • 1988
  • Radiation dose outside the radiotherapy treatment field can be significant and therefore is of clinical interest estimating organ dose. We have made measurements of dose at distances up to 70 cm from the central axis of $5{\times}5$, $10{\times}10$, $15{\times}15$, and $25{\times}25$ cm radiation fields of Co-60 ${\gamma}-ray$, at 5 cm depth in water. Contributions to the total secondary radiation dose from water scatter, machine (collimator) scatter and leakage radiation have been seperated. We have found that the component of dose from water scatter can be described by simple exponential function of distance from the central axis of the radiation field for all field sizes. Machine scatter contributes 20 to 60% of the total secondary dose depending on field size and distance from the field. Leakage radiation contributes very little dose, but becomes the dominant componant at distance beyond 40 cm from the central axis. Then, wedges can cause a factor 2 to 3 increase in dose at any point outside the field compared with the dose when no wedge is used. Adding blocks to a treatment field can cause an increase in dose at points outside the field, but the effect is much smaller than the effect of a wedge. From the results of these measurements, doses to selected organs outside the field for specified treatment geometries were estimated, and the potential for reducing these organ doses by additional shielding was assessed.

  • PDF