• Title/Summary/Keyword: Leak detection

Search Result 242, Processing Time 0.031 seconds

Prevention of Soil Contamination from Underground Storage Facilities of Petroleum Product and Hazardous Chemical Compounds (유류 및 유해화학물질 저장시설에서의 토양오염 방지대책)

  • 배우근;홍종철;정진욱;김종호
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.4
    • /
    • pp.40-47
    • /
    • 2002
  • The practices of the construction and management of the petroleum and hazardous chemical compound storage facilities in Korea were investigated extensively, and the problems were identified. The advanced technologies in the U.S.A were comparatively studied. Considering the effectiveness of leak prevention and applicability, the following measures were suggested. To prevent corrosion of a tank, a clad tank, an interior lining tank, or a double-wall tank were thought to be the most cost effective. For piping. use of non-metalic materials was suggested. A catchment basin seemed to be effective for preventing spills. For monitoring of leaks, constructions of more than one of detection systems, such as an automatic leak detection device. a vapor detection system, a groundwater monitoring system, or a double-wall monitoring system, were recommended.

Development of leakage test facility for leak signal characteristic analysis in water pipeline (상수도관로 누수신호의 특성 분석을 위한 누수 실험시설 개발)

  • Park, Sanghyuk;Kwak, Philljae;Lee, Hyundong;Choi, Changho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.5
    • /
    • pp.459-469
    • /
    • 2017
  • A real scale leakage test facility was developed to study the leak signal characteristics of water supply pipelines, and then leak tests were carried out. The facility was designed to overcome the limited experimental circumstances of domestic water supply pipeline experimental facilities. The length of the pipeline, which was installed as a straight line, is 280m. Six pipes were installed on a 70m interval with different pipe material and diameters that are DCIP(D200, D150, D100, D80), PE(D75) and PVC(D75).The intensity of the leakage is adjusted by changing the size of the leak hole and the opening rate of ball valve. Various pressure conditions were simulated using a pressure reducing valve.To minimize external noise sources which, deteriorate the quality of measured leak signal, the facility was built at a quiet area, where traffic and water consumption by customers is relatively rare. In addition, the usage of electric equipment was minimized to block out noise and the facility was operated using manual mode. From the experimental results of measured leakage signal at the facility, it was found that the signal intensity weakened and the signal of high frequency band attenuated as the distance from the water leakage point increased.

The Stability Analyses of the Overheat Controller Unit

  • Zhao, Wenzhi;Liu, Weiqiang
    • International Journal of Control, Automation, and Systems
    • /
    • v.1 no.2
    • /
    • pp.203-205
    • /
    • 2003
  • A false signal problem of the bleed air leak detection system in a widely used modem airplane is studied in this paper. It is considered to be a problem of stability of the controller unit. An equivalent circuit is extracted from the study. The circuit is considered to be an alternative bridge. A mathematical model is derived to describe the stability of the circuit. The conclusion is drawn that the sending of the false signal is relevant to not only the sensors, but also the detector. If a parameter in the detector is readjusted, then the problem may be avoided.

A Technology of Micro-leak Detection (미세 누출 탐지 기술)

  • Choi, Yourak;Lee, Jaecheol;Cho, Jaewan
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2021.07a
    • /
    • pp.685-687
    • /
    • 2021
  • 본 논문에서는 플랜트 배관의 기체 누출 탐지방안에 대하여 기술한다. 배관 누출 발생 시 배관 내부 압력과 누출부 크기의 조합에 따라 누출 초음파 발생 여부가 결정되는데, 누출 시 초음파가 발생하는 경우와 그렇지 않은 경우에 대하여 배관 누출을 탐지하는 방안과 보온재 배관의 누출탐지 방안에 대하여 설명한다. 또한 배관 파단을 상시감시하기 위한 대량의 무선센서 운용에 따른 대량 누출탐지신호의 실시간 처리를 위한 쿠버네티스 기반의 분산처리형 진단 시스템 구현 방안에 대하여 기술한다.

  • PDF

A Study on the Leakage Characteristic Evaluation of High Temperature and Pressure Pipeline at Nuclear Power Plants Using the Acoustic Emission Technique (음향방출기법을 이용한 원전 고온 고압 배관의 누설 특성 평가에 관한 연구)

  • Kim, Young-Hoon;Kim, Jin-Hyun;Song, Bong-Min;Lee, Joon-Hyun;Cho, Youn-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.5
    • /
    • pp.466-472
    • /
    • 2009
  • An acoustic leak monitoring system(ALMS) using acoustic emission(AE) technique was applied for leakage detection of nuclear power plant's pipeline which is operated in high temperature and pressure condition. Since this system only monitors the existence of leak using the root mean square(RMS) value of raw signal from AE sensor, the difficulty occurs when the characteristics of leak size and shape need to be evaluated. In this study, dual monitoring system using AE sensor and accelerometer was introduced in order to solve this problem. In addition, artificial neural network(ANN) with Levenberg.Marquardt(LM) training algorithm was also applied due to rapid training rate and gave the reliable classification performance. The input parameters of this ANN were extracted from varying signal received from experimental conditions such as the fluid pressure inside pipe, the shape and size of the leak area. Additional experiments were also carried out and with different objective which is to study the generation and characteristic of lamb and surface wave according to the pipe thickness.

An Experimental Study on Detection of Gas Leakage Position by Monitoring Pressure Values at City Gas Pipeline (압력값 모니터링을 통한 배관 내 가스누출감지에 대한 실험적 연구)

  • Jin, Kyoung-Min;Choi, Gyu-Hong;Lee, Song-Kyu;Chung, Tae-Yong;Shin, Dong-Hoon;Hwang, Seung-Sik;Oh, Jeong-Seok
    • Journal of Energy Engineering
    • /
    • v.20 no.4
    • /
    • pp.292-297
    • /
    • 2011
  • Gas pipeline safety management and risk prediction are recognized as a very important issue. And the effort to prevent accidents is essential. So, in this study, it was studied through correlation of pressure changes for leak point detection in real-time. It experimented by installing the five leakage valves in the pipe of 378 m and compared the actual leak points with simulation results. The results showed that experimental leak points and the actual leak points have differences within the 6 m. And this technology has to be commercialized by the demonstration in dangerous zone.

An Algorithm for Detecting Leak of Defaced Confidential Information Based on SVDD (SVDD 기반 중요문서 변조 유출 탐지 알고리즘)

  • Ghil, Ji-Ho;Nam, Ki-Hyo;Kang, Hyung-Seok;Kim, Seong-In
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.20 no.1
    • /
    • pp.105-111
    • /
    • 2010
  • This paper proposes the algorithm which addresses the problem of detecting leak of defaced confidential documents from original confidential document. Generally, a confidential document is defaced into various forms by insiders and then they are trying to leak these defaced documents to outside. Traditional algorithms detecting leak of documents have low accuracy because they are based on similarity of two documents, which do not reflect various forms of defaced documents in detection. In order to overcome this problem, this paper proposes a novel v-SVDD algorithm which is based on SVDD, the novelty detection algorithm. The result of experiment shows that there is significant improvement m the accuracy of the v-SVDD in comparison with the traditional algorithms.