Browse > Article

Prevention of Soil Contamination from Underground Storage Facilities of Petroleum Product and Hazardous Chemical Compounds  

배우근 (한양대학교 토목/환경공학과)
홍종철 (삼안건설기술공사)
정진욱 (한양대학교 토목/환경공학과)
김종호 (한양대학교 토목/환경공학과)
Publication Information
Journal of Soil and Groundwater Environment / v.7, no.4, 2002 , pp. 40-47 More about this Journal
Abstract
The practices of the construction and management of the petroleum and hazardous chemical compound storage facilities in Korea were investigated extensively, and the problems were identified. The advanced technologies in the U.S.A were comparatively studied. Considering the effectiveness of leak prevention and applicability, the following measures were suggested. To prevent corrosion of a tank, a clad tank, an interior lining tank, or a double-wall tank were thought to be the most cost effective. For piping. use of non-metalic materials was suggested. A catchment basin seemed to be effective for preventing spills. For monitoring of leaks, constructions of more than one of detection systems, such as an automatic leak detection device. a vapor detection system, a groundwater monitoring system, or a double-wall monitoring system, were recommended.
Keywords
Underground storage facilities; petroleum and hazardous chemical compound; leak prevention; corrosion-prevented tank; detection system;
Citations & Related Records
연도 인용수 순위
  • Reference
1 박용하,이승희, '토양환경보전을위한오염방지기준 및 관리대책'. 한국환경기술개발원,pp. 117-132 (1995)
2 한국토양환경학회, '모염토양복원기술및 제도발전에 관한 연구'. 국립환경연구원, 제 1권, p. VII-25 (1997)
3 (재)한국위험물안전기술센타, '위험물의 성상 및 시설기준'. (주)코데콤, 서울 (1993)
4 EPA, Straght Talk in Tanks: A Summary of Leak Detection Methods for Petroleum Underground Storage Tank Sys-tems. EPA/530/UST-90/012 (1990)
5 Kostecki, P. T., and Calabrease, E. J., 'Petroleum Contami-nated Soil Vol 1: Remedation Techniques, Environmental Fate, Risk Assessment', Lewis Pulisher. USA (1988)
6 환경부, '토양환경보전법령' (1996)
7 Lewis Publishers, hic., 'Underground Storage Systems-Leak Detection and Monitoring', Lewis Publishers, Inc. (1996)
8 Underwhters Laboratories, Inc. (UL 971-1995), Nonmetal-lic Underground Piping for Flammable Liquids (1995)
9 EPA, Musts For Usts, EPA 530-UST-88-008 (1988)
10 Petroleum Equipment Institute, 'Recommended Practices for Installation of Underground Liquid Storage Systems' (RP 100-86). Tulsa, OK: Petroleum Equipment Institute (1986)
11 EPA, Don't wait until 1998, Spill, OverSll, and Corrosion Protection for Underground Storage Tanks, EPA 510-B-94-002 (1994)