실배관 파괴특성 평가에 관한 연구 (I) (A Study on the Evaluation of the Pipe Fracture Characteristic (I))

  • 박재실;석창성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.345-350
    • /
    • 2001
  • In order to perform elastic-plastic fracture mechanical analyses, fracture resistance curves for concerned materials are required. 1T-CT specimen was used to obtain fracture resistance curves. But the fracture resistance curve by the 1T-CT specimen was very conservative to evaluate the integrity of the structure. And fracture resistance curve was affected by the specimen geometry and crack plane orientation. The objective of this paper is to be certain the conservativeness of the fracture resistance curve by the 1T-CT specimen and to provide the additional safety margin. For these, the fracture tests using the real pipe specimen and standard 1T-CT specimen test were performed. 4-point bending jig was manufactured for pipe test and direct current potential drop method was used to measure the crack extension and length for pipe test. From the pipe and the 1T-CT specimen test results, it was observed that the J-integral of the 1T-CT specimen test at the crack initiation point was very small compare to that of the pipe specimen test.

  • PDF

CURRENT RESEARCH AND DEVELOPMENT ACTIVITIES ON FISSION PRODUCTS AND HYDROGEN RISK AFTER THE ACCIDENT AT FUKUSHIMA DAIICHI NUCLEAR POWER STATION

  • NISHIMURA, TAKESHI;HOSHI, HARUTAKA;HOTTA, AKITOSHI
    • Nuclear Engineering and Technology
    • /
    • 제47권1호
    • /
    • pp.1-10
    • /
    • 2015
  • After the Fukushima Daiichi nuclear power plant (NPP) accident, new regulatory requirements were enforced in July 2013 and a backfit was required for all existing nuclear power plants. It is required to take measures to prevent severe accidents and mitigate their radiological consequences. The Regulatory Standard and Research Department, Secretariat of Nuclear Regulation Authority (S/NRA/R) has been conducting numerical studies and experimental studies on relevant severe accident phenomena and countermeasures. This article highlights fission product (FP) release and hydrogen risk as two major areas. Relevant activities in the S/NRA/R are briefly introduced, as follows: 1. For FP release: Identifying the source terms and leak mechanisms is a key issue from the viewpoint of understanding the progression of accident phenomena and planning effective countermeasures that take into account vulnerabilities of containment under severe accident conditions. To resolve these issues, the activities focus on wet well venting, pool scrubbing, iodine chemistry (in-vessel and ex-vessel), containment failure mode, and treatment of radioactive liquid effluent. 2. For hydrogen risk: because of three incidents of hydrogen explosion in reactor buildings, a comprehensive reinforcement of the hydrogen risk management has been a high priority topic. Therefore, the activities in evaluation methods focus on hydrogen generation, hydrogen distribution, and hydrogen combustion.

Identification of the Failure of VFD Heat Sink at Fossil Power Plant

  • Jung, Jine-sung;Lee, Han-sang;Kim, Min-tae;Kim, Eui-hyun
    • Corrosion Science and Technology
    • /
    • 제8권4호
    • /
    • pp.153-156
    • /
    • 2009
  • The water cooling system for VFD (Variable Frequency Drive) of a fossil fuel power plant was reported to be shut down due to a water leak at the metal connection of the heat-sink to the hoses. In order to identify the cause of the failure, the system was visually inspected, and corrosion products were analyzed with SEM equipped with EDX. The failure was observed repeatedly at the nipples of certain location, suggesting galvanic corrosion. In a U-shaped heat sink with two nipples, for inlet and outlet, only one nipple was corrosively damaged at the tip, while the other was not. Most of the corrosion products were observed at the sound nipple and in the filter, identified as $Cu(OH)_2$. Some other corrosion products, composed of mostly $Cu_2O$, were found at the corrosively attacked nipple. A fair amount of Cl was also detected on the surface of the damaged nipple. It was concluded that galvanic corrosion was occurred due to a current leakage over the whole system, and the damage was accelerated by the accumulated chlorine ions in the cooling water.

단일 트랜지스터용 강유전체 메모리의 Buffer layer용 $Y_{2}O_3$의 연구 ($Y_{2}O_3$ Films as a Buffer layer for a Single Transistor Type FRAM)

  • 장범식;임동건;최석원;문상일;이준신
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1646-1648
    • /
    • 2000
  • This paper investigated structural and electrical properties of $Y_{2}O_3$ as a buffer layer of sin91r transistor FRAM (ferroelectric RAM). $Y_{2}O_3$ buffer layers were deposited at a low substrate temperature below 400$^{\circ}C$ and then RTA (rapid thermal anneal) treated. Investigated parameters are substrate temperature, $O_2$ partial pressure, post- annealing temperature, and suppression of interfacial $SiO_2$ layer generation. for a well-fabricated sample, we achieved that leakage current density ($J_{leak}$) in the order of $10^{-7}A/cm2$, breakdown electric field ($E_{br}$) about 2 MV/cm for $Y_{2}O_3$ film. Capacitance versus voltage analysis illustrated dielectric constants of 7.47. We successfully achieved an interface state density of $Y_{2}O_3$/Si as low as $8.72{\times}10^{10}cm^{-2}eV^{-1}$. The low interface states were obtained from very low lattice mismatch less than 1.75%.

  • PDF

Reactive RF Magnetron Sputter Deposited $Y_2O_3$ Films as a Buffer Layer for a MFIS Transistor

  • Lim, Dong-Gun;Jang, Bum-Sik;Moon, Sang-Il;Junsin Yi
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.47-50
    • /
    • 2000
  • This paper investigated structural and electrical properties of $Y_2$ $O_3$ as a buffer layer of single transistor FRAM (ferroelectric RAM). $Y_2$ $O_3$ buffer layers were deposited at a low substrate temperature below 40$0^{\circ}C$ and then RTA (rapid thermal anneal) treated. Investigated parameters are substrate temperature, $O_2$ partial pressure, post-annealing temperature, and suppression of interfacial $SiO_2$ layer generation. For a well-fabricated sample, we achieved that leakage current density ( $J_{leak}$) in the order of 10$^{-7}$ A/$\textrm{cm}^2$, breakdown electric field ( $E_{br}$ ) about 2 MV/cm for $Y_2$ $O_3$ film. Capacitance versus voltage analysis illustrated dielectric constants of 7.47. We successfully achieved an interface state density of $Y_2$ $O_3$/Si as low as 8.72x1010 c $m^{-2}$ e $V^{-1}$ . The low interface states were obtained from very low lattice mismatch less than 1.75%.

  • PDF

Position Sensorless Control of PMSM Drive for Electro-Hydraulic Brake Systems

  • Yoo, Seungjin;Son, Yeongrack;Ha, Jung-Ik;Park, Cheol-Gyu;You, Seung-Han
    • 드라이브 ㆍ 컨트롤
    • /
    • 제16권3호
    • /
    • pp.23-32
    • /
    • 2019
  • This study proposed a fault tolerant control algorithm for electro-hydraulic brake systems where permanent magnet synchronous motor (PMSM) drive is adopted to boost the braking pressure. To cope with motor position sensor faults in the PMSM drive, a braking pressure controller based on an open-loop speed control method for the PMSM was proposed. The magnitude of the current vector was determined from the target braking pressure, and motor rotational speed was derived from the pressure control error to build up the braking pressure. The position offset of the pump piston resulting from a leak in the hydraulic system is also compensated for using the open-loop speed control by moving the piston backward until it is blocked at the end of stroke position. The performance and stability of the proposed controller were experimentally verified. According to the results, the control algorithm can be utilized as an effective means of degraded control for electro-hydraulic brake systems in the case that a motor position sensor fault occurs.

발전 제어시스템의 융합보안 연구 (A Study on Convergence Security of Power Generation Control System)

  • 이대성
    • 융합보안논문지
    • /
    • 제18권5_1호
    • /
    • pp.93-98
    • /
    • 2018
  • 한국수력원자력, 한국전력공사, 한국남동발전 등의 발전 제어시스템은 전력을 공급하는 국가의 주요 인프라 시설로 악의적인 해킹 공격이 진행될 경우 그 피해는 상상을 초월한다. 실제로 한국수력원자력은 해킹 공격을 당하여 내부정보가 유출되는 등 사회적인 큰 문제를 야기하였다. 본 연구에서는 최근 이슈가 되고 있는 융합보안 연구에 대해 전력회사 중심의 발전 제어시스템을 대상으로 그 환경을 분석하고, 현황을 분석하여 다양한 발전 제어시스템의 안정화를 위한 전략체계 수립과 대응책을 제시하고자 한다. 다양한 물리적 보안시스템(시설), IT 보안시스템, 출입통제시스템 등에서 나오는 데이터 형태를 정규화하고 통합하여 융합인증을 통해 전체 시스템을 통제하고, 융합관제를 통해 위험을 탐지하는 방법을 제안한다.

  • PDF

Core Circuit Technologies for PN-Diode-Cell PRAM

  • Kang, Hee-Bok;Hong, Suk-Kyoung;Hong, Sung-Joo;Sung, Man-Young;Choi, Bok-Gil;Chung, Jin-Yong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제8권2호
    • /
    • pp.128-133
    • /
    • 2008
  • Phase-change random access memory (PRAM) chip cell phase of amorphous state is rapidly changed to crystal state above 160 Celsius degree within several seconds during Infrared (IR) reflow. Thus, on-board programming method is considered for PRAM chip programming. We demonstrated the functional 512Mb PRAM with 90nm technology using several novel core circuits, such as metal-2 line based global row decoding scheme, PN-diode cells based BL discharge (BLDIS) scheme, and PMOS switch based column decoding scheme. The reverse-state standby current of each PRAM cell is near 10 pA range. The total leak current of 512Mb PRAM chip in standby mode on discharging state can be more than 5 mA. Thus in the proposed BLDIS control, all bitlines (BLs) are in floating state in standby mode, then in active mode, the activated BLs are discharged to low level in the early timing of the active period by the short pulse BLDIS control timing operation. In the conventional sense amplifier, the simultaneous switching activation timing operation invokes the large coupling noise between the VSAREF node and the inner amplification nodes of the sense amplifiers. The coupling noise at VSAREF degrades the sensing voltage margin of the conventional sense amplifier. The merit of the proposed sense amplifier is almost removing the coupling noise at VSAREF from sharing with other sense amplifiers.

고전압 대전류용, Seal-off TVS(Triggered Vacuum Switch) 연구 (Study of Seal-off Triggered Vacuum Switch(TVS) for High Voltage and High Current)

  • 박성수;한영진;김상희;권영건;김승환;박용정;홍만수;남상훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1823-1826
    • /
    • 2002
  • The purpose of this experiment was to develope Triggered Vacuum Switch (TVS) for the high voltage and high current. The TVS has an array of rods of alternate polarity in which a fixed gap spacing is maintained between the rods. The cross section of each rod has trapezoidal shape. It consists of electrode, ceramic chamber, getter and trigger. Currently, triggered vacuum switch (TVS) with seal-off has been designed and fabricated at PAL. An experimentation and trigger devices for TVS were designed for testing characteristics of electricity. For making the prototype of TVS, it is developed of fabrication process and fined of electrode material. The fabrication of the TVS is a lot of process which have manufacturing of part, chemical clean, ceramic brazing and metal welding. The fabricated TVS is tested of leak for vacuum, hold-off voltage and conditioning of trigger system. The TVS has pinch-off after it is removed of gas in the TVS and activated of getter in degassing furnace. The prototype TVS tested about 20 kV, 75 kA, 83 ${\mu}s$ with 100 kJ capacitor bank and inductance 5 ${\mu}H$. This paper describes the results of tests and the characteristics of the switch.

  • PDF

Mg 합금 유전양극에 의한 온수Boiler의 음극방식특성에 관한 연구(1) (Study on the Cathodic Protection Characteristics of Hot Water Boiler by Mg-Alloy Galvanic Anode(1))

  • 임우조;윤병두
    • 수산해양기술연구
    • /
    • 제37권2호
    • /
    • pp.147-152
    • /
    • 2001
  • 본 연구에서는 수도수 중에서 Mg합금유전양극에 의한 연강재 온수보일러의 음극방식특성을 연구한 결과 다음과 같은 결론을 얻었다. 1) 온수보일러 관체의 개로전위에서나 전위가 높은 구간에서 모재의 부식전류밀도가 용접부위의 부식전류밀도보다 더 적게 배류된다. 2) 주조된 표면 그대로의 Mg합금 유전양극의 전류밀도는 주조된 표면을 연마한 상태의 Mg합금 유전양극의 전류밀도보다 더 많이 배류된다. 3) Mg합금 유전양극으로부터 거리가 멀어질수록 연강재 온수보일러의 음극방식전위는 높게 나타나고, 음극방식시간이 경과하면서 방식전위는 높게 나타나다가 6-10일 이후부터 방식전위는 안정되고 있다.

  • PDF