• Title/Summary/Keyword: Leak Test

Search Result 255, Processing Time 0.027 seconds

Standardization and Method Selection for the Trenchless Repair Technology of Sewer using Cured-in-place Pipe

  • Kim, Taeeung
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.14 no.2
    • /
    • pp.70-78
    • /
    • 2022
  • The trenchless entire repair technology (TERT) have many different names depending on the companies, and they have the same or similar methods as well as materials. In addition, there was quiet difficulty in application of field working and even confuse to classify for new TERT, while application criteria of TERT is not listed systematically. This study proposed standardization and method for TERT affecting by pipe condition, working materials, working method, specification/quantity per unit according to field condition, strange affairs and others. Determination criteria of defective sewer pipe has proposed to effective method which modify a criteria between Ministry of Environment and Seoul Metropolitan City. A Cured-in-place pipe (CIPP) is suitable for TERT, and the design criteria for the entire broken pipe are proposed when the pipe itself deforms more than 10%. A check lists are specimen preparing, hardening site made by clamped mold, numbers, flexural and tensile property, water leak and desquamation test, and have to use material property of minimum CIPP value depend on ISO 11296-4, ISO 11297-4, KS M3550-7 and KS M3550-9.

Remote NDT for Inspection of Reactor Vessel Components of fast Breeder Test Reactor

  • Anandapadmanaban, B.;Srinivasan, G.;Kapoor, R.P.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.5
    • /
    • pp.520-525
    • /
    • 2003
  • Fast Breeder Test Reactor (FBTR) is a 40MW (thermal) / 13.2MW (electrical), Plutonium - Uranium mixed carbide fuelled, sodium cooled, loop type nuclear reactor operating at Indira Gandhi Centre for Atomic Research (IGCAR), Kalpakkam. Its main aim is to generate experience in operation of fast reactors and sodium systems and to serve as an irradiation facility for development of fuels and structural materials fur fast reactors. Nuclear reactors pose difficulties to the NDT techniques used to monitor the conditions of the internal components. Sodium cooled fast breeder reactors have their own typical difficulties in using the NDT techniques. These are due to the need for operation in aggressive environment of nuclear radiation and sodium (molten/vapour), as well as the need to maintain leak tightness of a very high order during all states of reactor operation and shutdown for fuel handling, maintenance and remote inspection. This paper discusses the following NDT techniques, which have been successfully used for the past 15 years in FBTR: (i) Periscope and Projector, (ii) Core Co-ordinate Measuring Device and, (iii) Optical fiberscope. The inspection using these techniques have given confidence for further reactor operation at high power by giving useful data on the conditions of the components inside the reactor vessel.

Improvement of Production Process based on Performance Evaluation System of Unified Heater (통합히터 성능평가장치를 통한 생산 공정 개선)

  • Han, Woo-Hyun;Yoon, Dal-Hwan
    • Journal of IKEEE
    • /
    • v.18 no.1
    • /
    • pp.114-118
    • /
    • 2014
  • This paper presents improvement of the production process of a unified fuel heater with the help of the performance evaluation system. In order to enhance a starting capability of diesel-engine car, the unified fuel heater is proposed, which consists of main body, upper plate, stopper, lower plate, PTC, screw, bimetal and terminals. In the proposed heater, the sensor is combined with heater body not only to maximize the performance of car but also to reduce the production cost. The performance test chamber is proposed to evaluate the performance of heater. Especially, an effective manufacturing progress for assembling the heater elements can cut down expenses.

Performance and Reliability Characteristics of the Free Piston Free Displacer Stirling Cryocooler

  • Park, Seong-Je;Hong, Yong-Ju;Kim, Hyo-Bong;Koh, Deuk-Yong;Kim, Yang-Hoon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.2
    • /
    • pp.46-51
    • /
    • 2004
  • This paper presents the results of a series of performance and reliability tests for the Stirling cryocooler. Infrared sensor systems incorporating cryocoolers are required to be qualified to the appropriate specification for the performance and reliability. FPFD Stirling cryocooler is currently under development for cooling infrared detector. Manufactured Stirling cryocooler delivers approximately 0.9W cooling at 80K for 30W∼40W of input power. It takes approximately 2 minutes to cool down to 80K at the ambient temperature of 23$^{\circ}C$. Performance characteristics for the vibration, acoustic noise, EMI and leak rate of the Stirling cryocooler are evaluated. We performed low and high temperature keeping test from -32$^{\circ}C$ to +52$^{\circ}C$ and operating test at high and low temperature cyclic range with acceptance tests performed at scheduled intervals. Cooling capacity is determined as a function of the temperatures at the compressor, hot end and cold tip at the expander. Finally, we describe the experimental facility for the MTTF evaluation and some typical results of the Stirling cryocooler.

Design and Evaluation of a Crankcase Relief Valve Spring for LNG-Fueled Ships (LNG 연료추진 선박용 크랭크실 릴리프 밸브 스프링의 설계 및 평가)

  • Lee, Hyo Ryeol;Ahn, Jung Hwan;Ahn, Byoung Hoon;Kim, Hwa Young
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.3
    • /
    • pp.263-269
    • /
    • 2015
  • Growing concerns regarding air pollution have recently increased the demand for liquefied natural gas (LNG) fueled ships. LNG-fueled ships are equipped with an explosion relief valve in the crankcase to relieve excessive pressure and stop flames from emitting from the crankcase. In this study, a finite element analysis was conducted to evaluate the crankcase relief valve disk spring design using an ANSYS Workbench, v.15. The setting pressure, leak and explosion test performed by european standard EN14797 to evaluate function and mechanical integrity of crankcase relief valve. The tests results indicate that the pressure of the crankcase relief valve is 3.05 bar, with no air leakage at 2.97 bar. Finally, the mechanical integrity of the crankcase relief valve was confirmed through an explosion test in which the valve plate assembly, flame arrester, and other parts were safe from fracturing.

An Experimental Study on the Pumping Performance of the Multi-stage Disk-type Drag Pump (다단 원판형 드래그펌프의 배기 성능에 관한 실험적 연구)

  • 권명근;허중식;황영규
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.2
    • /
    • pp.79-85
    • /
    • 2003
  • Experimental investigations are performed for the rarefied gas flows in a multi-stage disk-type drag pump. The pump considered in the present study consists of grooved rotors and stators. The flow-meter method is adopted to calculate the pumping speed. Compression ratios and pumping speeds for the nitrogen gas are measured under the outlet pressure range of 0.13∼533 Pa. The present experimental data show the leak-limited value of the compression ratio in the molecular transition region. The rotational speed of the pump is 24,000rpm, and nitrogen is used as a test gas. The pumping characteristics of various drag pumps are performed. The inlet pressures are measured for various outlet pressures of the test pump. The ultimate pressures for zero throughput are measured for three-stage, two-stage and single-stage disk-type, respectively.

Development of a Magnetic Seal and the Leak Test (마그네틱씰 개발 및 기밀 평가 시험)

  • Kim, Ock-Hyun;Lee, Min-Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.2
    • /
    • pp.79-83
    • /
    • 2011
  • Magnetic seal uses a magnetic fluid to seal a gap between a rotating shaft and housing. It is distinguished from other kinds of seals from the fact that solid contact does not occur in the seal. This implies that it is free from solid rubbing thus dustless and provides a clean circumstance. That is the reason why the magnetic seal is used exclusively for most of vacuum chambers in semiconductor process where dustless clean circumstance is critical. A magnetic seal has been developed of which design parameters are determined based on published data, and an air pressure test has been done to examine its sealing capability. Effects of some design parameters have been studied through FEM analysis. The results show some notable aspects of design parameters and provide suggestions for developing the seals. Regarding the sealing capacity of the magnetic seal the factor to match the theoretical value with the actual one was found to be 0.4~0.7, which means still there is some discrepancy between theory and actual.

A Study of Construction of a Hydrogen Peroxide Supply System for Liquid Rocket Engine (액체로켓엔진 산화제로서의 과산화수소 공급계 구축에 관한 연구)

  • Jeon, Jun-Su;Lee, Yang-Suk;Kim, Young-Mun;Choi, Yu-Ri;Ko, Young-Sung;Kim, Yoo;Kim, Sun-Jin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.14 no.2
    • /
    • pp.63-70
    • /
    • 2010
  • A construction process of hydrogen peroxide supply system was investigated to use hydrogen peroxide as an oxidizer of bi-propellant liquid rocket engine. To use hydrogen peroxide as a rocket propellant, it has to be in high concentration over 90%. It is very important to make the supply system free of pollutants, because highly concentrated hydrogen peroxide has a characteristic of hypersensitive reaction to pollutants such as dust and oil sludge. We suggested the cleaning and passivation process of main components to minimize pollutants of the supply system. In conclusion, we verified stability of the constructed supply system by leak test and hot test.

Study on Development of Performance Evaluation Guidelines for Leak Test Smart Gas Meter (누출점검용 스마트가스미터의 성능시험 가이드라인 개발 연구)

  • Kim, Minjun;Oh, Jeong Seok
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.5
    • /
    • pp.8-14
    • /
    • 2019
  • Although the rate of city gas supply in South Korea has grown significantly, the fields related to gas meters have not yet escaped from the initial method of service (e.g. measurement, safety checks, billing, etc). As smart gas meters are actively developed and researched, the introduction of smart gas meters requires rational performance evaluation methods and standards to verify reliability and safety. The purpose of this paper is to make a prototype of the performance evaluation to test the performance of the smart gas meter and to derive the performance evaluation method by conducting the demonstration operation so that the smart gas meter can be smoothly distributed in South Korea.

A study on the Development and Evaluation of Sludge Occlusion Reduced Diffuser (폐색 저감형 산기관의 개발 및 적용성 평가)

  • Kim, Young-Hoon;Kim, Kwan-Yeop;Lee, Eui-Jong;Nam, Jong-Woo;Lee, Chang-Ha;Jeon, Min-Jung;Kim, Hyung-Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.1
    • /
    • pp.41-49
    • /
    • 2011
  • The diffuser which is conventionally adapted to MBR, has problem that decreasing the cleaning effect of membrane module by inflexible air supply due to the occlusion of sludge from diffuser hole. To solve this problem, diffuser structure of submerged module should be improved to discharge sludge which is flow into the diffuser for prevent occlusion in the diffuser. In this study, the structure of the diffuser was reformed to open lower part for preclusion the blocking. And the outlet diameter of the diffuser was drawn through the condition for the depth of water and air rate, to prevent air-leak condition of improved diffuser. Moreover, application is evaluated by comparing test with occlusion effect of the conventional and improved diffuser. From the results, air-water boundary changes are steady with changes of water depth and it shows linear relation about air rate. By using this linear numerical formula, the height of diffuser's outlet can be decided. Also, it displays that it can prevent the occlusion effect during the comparing test. Hereafter, if this diffuser is applied to practical MBR process, the occlusion problem of diffuser will be disappeared.