Browse > Article

A study on the Development and Evaluation of Sludge Occlusion Reduced Diffuser  

Kim, Young-Hoon (성균관대학교 건설환경시스템공학과)
Kim, Kwan-Yeop (포스코건설 녹색환경연구그룹 기술연구소/R&D CENTER)
Lee, Eui-Jong (성균관대학교 건설환경시스템공학과)
Nam, Jong-Woo (성균관대학교 건설환경시스템공학과)
Lee, Chang-Ha (성균관대학교 건설환경시스템공학과)
Jeon, Min-Jung (성균관대학교 건설환경시스템공학과)
Kim, Hyung-Soo (성균관대학교 건설환경시스템공학과)
Publication Information
Journal of Korean Society of Water and Wastewater / v.25, no.1, 2011 , pp. 41-49 More about this Journal
Abstract
The diffuser which is conventionally adapted to MBR, has problem that decreasing the cleaning effect of membrane module by inflexible air supply due to the occlusion of sludge from diffuser hole. To solve this problem, diffuser structure of submerged module should be improved to discharge sludge which is flow into the diffuser for prevent occlusion in the diffuser. In this study, the structure of the diffuser was reformed to open lower part for preclusion the blocking. And the outlet diameter of the diffuser was drawn through the condition for the depth of water and air rate, to prevent air-leak condition of improved diffuser. Moreover, application is evaluated by comparing test with occlusion effect of the conventional and improved diffuser. From the results, air-water boundary changes are steady with changes of water depth and it shows linear relation about air rate. By using this linear numerical formula, the height of diffuser's outlet can be decided. Also, it displays that it can prevent the occlusion effect during the comparing test. Hereafter, if this diffuser is applied to practical MBR process, the occlusion problem of diffuser will be disappeared.
Keywords
Diffuser; Diffuser Occlusion; MBR; Air Scrubbing; Physical Cleaning;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Lee, J., Ahn, W. -Y., and Lee, C. -H., (2001) Comparison of the filtration characteristics between attached and suspended growth microorganisms in submerged membrane bioreactor, Water Res., 35(10), 2435-2445.   DOI   ScienceOn
2 P. Le-Clech., A. Fane and G. Leslie, (2005), MBR focus : the operators' perspective, Filtration & Separation, 42(5), pp. 20-23.   DOI   ScienceOn
3 Pierre Le Clech, Bruce Jefferson, In Soung Chang and Simon J. Judd, (2003), Critical flux determination by the flux-step method in a submerged membrane bioreactor, Journal of Membrane Science, 227(1-2), pp. 81-93.   DOI   ScienceOn
4 S. P. Hong, T. H. Bae, T. M. Tak, S. Hong, and A. Randall, (2002) Fouling control in activated sludge submerged hollow fiber membrane bioreactor, Desalination, 143(3), 219-228.   DOI   ScienceOn
5 Stephenson, T., Judd, S., Jefferson, B., and Brindle, K., (2000) Membrane bioreactor for wastewater treatment, IWA Publishing, London.
6 Whalley, P. B., (1987), Boiling, condensation, and gas-liquid flow, Oxford university press, USA
7 김관엽, 이의종, 송준섭, 김지훈, 김형수 (2008), 주기적인 약품역세를 적용한 침지형 MBR 시스템의 운전성능에 관한 연구, 대한상하수도학회, 22(1), pp. 87-92.
8 신동환, 백병도, 장인성 (2008), 침지형 생물 반응기 공정에서 플럭스 향상을 위한 공기 세척 효과에 관한 연구, 대한환경공학회, 30(9), pp. 948-954.
9 Bart Verrecht, Thomas Maere, Ingmar Nopens, Christoph Brepols and Simon Judd (2010) The cost of a large-scale hollow fibre MBR, Water Res., 44(18), 5274-5283.   DOI   ScienceOn
10 Chang, I. -S., Lee, C. -H., and Ahn, K. -H., (1999) Membrane filtration characteristics in membrane coupled activated sludge system - The effect of floc structure on membrane fouling, Sep. Sci. Technol., 34(9), 1743-1758.   DOI   ScienceOn
11 Hout, R. V., Gulitsaki, A., Barrnea, D., and Shemer, L., (2002) Experimental investigation of the velocity field induced by a taylor bubble rising in a stagnant water, Int. J. Multiphase Flow, 28(4), 579-596.   DOI   ScienceOn