• Title/Summary/Keyword: Lead in air

Search Result 621, Processing Time 0.027 seconds

Impact of PSI-KIT Nitriding model on hypothetical Spent Fuel Pool accident simulation

  • Mateusz Malicki;Terttaliisa Lind
    • Nuclear Engineering and Technology
    • /
    • 제55권7호
    • /
    • pp.2504-2515
    • /
    • 2023
  • In past years the Paul Scherrer Institute (PSI, Switzerland) and the Karlsruhe Institue of Technology (KIT, Germany)) collaborated to develop a model to account for the active role of nitrogen in the air oxidation of a Zircalloy cladding. The "PSI-KIT Nitriding Model for Zirconium based Fuel Cladding" model was implemented at PSI into PSI-MELCOR 1.8.6. In order to make a preliminary evaluation of the effect of the new model on the evolution of full-scale spent fuel pool accidents, one spent fuel pool event was analyzed using the PSI research version of PSI-MELCOR 1.8.6, which includes the nitriding model. To adapt an existing input deck for the calculations, a sensitivity study was conducted to find an optimal nodalization for the analyses. The nitriding model results were compared to those calculated with the MELCOR 1.8.6-PSI without the new nitriding model. The results demonstrate the effect of the nitriding reactions in spent fuel pool accident progression. Moreover, they confirm the impact of ZrN formation during cladding oxidation in air when the oxidation reactions lead to oxygen starvation inside the fuel assemblies. The nitriding reaction led to higher chemical heat generation during the accident and to an earlier failure of the cladding than when the effect of nitrogen reactions was not considered. It should be noted that the nitriding model, as implemented in the PSI version of MELCOR 1.8.6 has not yet been conclusively validated. Thereby the results presented in this paper should be treated as a preliminary demonstration of the capabilities of the model.

메타분석을 적용한 대기오염과 소아 천식 관련 입원의 상관성 평가 연구 (Relationship Between Exposure to Air Pollutants and Aggravation of Childhood Asthma : A Meta-Analysis)

  • 조용성;김호;이종태;현연주;김윤신
    • 한국대기환경학회지
    • /
    • 제17권5호
    • /
    • pp.425-437
    • /
    • 2001
  • This study is based on the uses meta-analysis methodology to examine the statistical consistency and importance of random variation among results of epidemiologic studies between air pollutants exposure and childhood asthma. Studies for this meta-analysis were conducted by reviewing previous results and by asking researcher active in this field for recommendations. Overall, 10 cases of air pollutants exposures and childhood asthma were reviewed. A variety of statistical methods for meta-analysis have been used to assess the combined effects, to identify heterogeneity, and to provide a single summary risk estimate based on a set of simiar epidemiologic studies. In this study, classification of exposure metircs on air environmental epidemiologic studies are reported for (1) aggravation of childhood asthma by a 50 ppb increase SO$_2$(6 individual studies); (2) aggravation of childhood asthma by a 50 ppb increase NO$_2$(5 individual studies); (3) aggravation of childhood asthma by a 50 ppb increase $O_3$(7 individual studies); (4) aggravation of childhood asthma by a 10$\mu\textrm{g}$/m$^3$increase PM$_{10}$ (4 individual studies); (5) aggravation of childhood asthma by a 1 ppm increase CO (2 individual studies); and (6) comparison of results between a Korean study results and this meta-analytic study. Results of this study indicated that an inverse-variance weighted pooling of the hospital admission risk at a 1ppm increment of CO levels was 1.12% (95% CI : 1.01 ~ 1.24). The hospital admission risk was estimated to increase 5% (95% CI : 1.02~1.08), 6%(95% CI : 1.04~1.09), and 5% (95% CI : 1.02~1.09) with each 50ppb increase of SO$_2$, NO$_2$, and $O_3$, respectively. In addition, our results lead to a small but significant elevation in risk of 2% (RR = 1.02, 95% CI = 1.01~1.04) with each 10$\mu\textrm{g}$/m$^3$increase of PM$_{10}$ among 4 individual studies. We found a small elevation in risk of childhood asthma, and pooled results of 10 epidemiologic studies of childhood asthma using increase a cut-off-point levels of air pollutants showed a few pieces of evidence. The results of this meta-analysis suggested that air pollution associated with an increased incidence of childhood asthma. According to this study, relationship between exposure to air pollutants and childhood asthma in Korea seem to be high than results of this meta-analysis.sis.

  • PDF

수입 음식료품의 푸드 마일리지 및 이산화탄소 배출량 산정 (Estimation of Food Miles and CO2 Emissions of Imported Food)

  • 주옥정;이재범;성미애;김수연;류지연;김대곤;홍유덕
    • 한국대기환경학회지
    • /
    • 제26권1호
    • /
    • pp.57-68
    • /
    • 2010
  • Increase in greenhouse gas emissions during the last century has led to remarkable changes in our environment and climate system. Many policy measures have been developed to reduce greenhouse gas emissions across the world, many of which require our lifestyle changes from energy-intensive to energy-saving. One of the changes in our living patterns is to consider food miles. A food mile is the distance food travels from where it is produced to where it is consumed. Providing information of food miles will help people choose low mileage food, helping promote a "green consumption" action and lead to a low carbon society with emission reduction systems. In this study, 10 items are selected from 23 Harmonized commodity description and 2-digit coding system (HS) to estimate their food miles, and $CO_2$ emissions released in the transportation of imported food. For the estimation, four countries are chosen-Korea, Japan, United Kingdom (UK) and France, with Korea and Japan's 2001, 2003, and 2007 trade statistics and UK and France's 2003 and 2007 trade statistics used. As a result, Korea showed in 2007 the highest level of food miles and $CO_2$ emissions per capita among 4 countries. That suggests that Korea should make an effort to purchase local food to reduce food miles and use low-carbon vehicles for food transport, contributing to reducing greenhouse gas emissions.

간접냉각이 이용된 지중송전케이블의 적정냉각조건에 관한 연구 (A Study on the Optimum Cooling Condition of the Underground Power Transmission Cable Equipped with a Separate Pipe Cooling System)

  • 박만흥;최규식;서정윤;김재근;이재헌
    • 설비공학논문집
    • /
    • 제4권4호
    • /
    • pp.263-276
    • /
    • 1992
  • The transmission current in a power cable is determined under the condition of separate pipe cooling. To this end, the thermal analysis is conducted with the standard condition of separate pipe cooling system, which constitutes one of the underground power transmission system. The changes of transmission current in a power cable with respect to the variation of temperatures and flow rates of inlet cooling water as well as the cooling spans are also determined. As a consequnce, the corresponding transmission current is shown to vary within allowable limit, resulting in the linear variation of the current for most of the cable routes. The abrupt changes of current, however, for the given flow rate of inlet cooling water in some cooling span lead to the adverse effects on the smooth current transmission within the underground power transmission system. In practice, it is expected that the desinging of the separate pipe cooling system in conjunction with the evaluation of system capacity should take into account the effects of design condition on the inlet cooling flow rate.

  • PDF

Non-contact monitoring of 3-dimensional vibrations of bodies using a neural network

  • Ha, Sung Chul;Cho, Gyeong Rae;Doh, Deog-Hee
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권10호
    • /
    • pp.1011-1016
    • /
    • 2015
  • Gas piping systems in power plants and factories are always influenced by the mechanical vibrations of rotational machines such as pumps, blowers, and compressors. Unusual vibrations in a gas piping system influence possible leakages of liquids or gases, which can lead to large explosive accidents. Real-time measurements of unusual vibrations in piping systems in situ prohibit them from being possible leakages owing to the repeated fatigue of vibrations. In this paper, a non-contact 3-dimensional measurement system that can detect the vibrations of a solid body and monitor its vibrational modes is introduced. To detect the displacements of a body, a stereoscopic camera system is used, through which the major vibration types of solid bodies (such as X-axis-major, Y-axis-major, and Z-axis-major vibrations) can be monitored. In order to judge the vibration types, an artificial neural network is used. The measurement system consists of a host computer, stereoscopic camera system (two-camera system, high-speed high-resolution camera), and a measurement target. Through practical application on a flat plate, the measured data from the non-contact measurement system showed good agreement with those from the original vibration mode produced by an accelerator.

2단 Gifford-McMahon 극저온냉동기의 특성실험 (An Experimental Study of the 2-stage Gifford-McMahon Cryorefrigerator)

  • 박성제;고득용;유창종;김의준;최헌오
    • 설비공학논문집
    • /
    • 제5권3호
    • /
    • pp.198-206
    • /
    • 1993
  • Experimental results of two stage Gifford-McMahon cryorefrigerator are described. In-prototype experiments, drive mechanism is Scotch Yoke type driven by stepping motor, copper meshes and lead balls are used for regenerator's materials in the first stage and the second stage, respectively. To find optimal conditions of the cryopump, no load temperature and refrigeration capacity according to the variation of cycle frequency and operating pressure are measured, and the cool down and load characteristics at particular cycle frequencies are presented. In general, as the cycle frequency is lowered, no load temperature is dropped but refrigeration capacity is diminished. As the representative result, in a case that the cycle frequency is 70rpm and steady state pressure is 14 atm, no load temperature of second stage is lowered to 10.5K in 55 minuters, and in this situation the refrigeration capacity of the first stage is 42W at 80K, that of the second stage is 11 W at 20K.

  • PDF

Lead (Pb) Concentrations in Soil, Air and Fruits of Sweet Orange (Citrus sinensis L. Osbeck) in Selected Landuse in Port Harcourt Metropolis, Rivers State, Nigeria

  • Eludoyin, Olatunde Sunday;Odimegwu, Vitus Chinonso
    • Journal of Forest and Environmental Science
    • /
    • 제34권4호
    • /
    • pp.284-292
    • /
    • 2018
  • The study investigated the concentrations of Pb in soil, air and fruit of C. sinensis in selected landuse types in Port Harcourt Metropolis, Rivers State, Nigeria. Five fruits of C. sinensis were collected randomly in residential, commercial, industrial and natural forest (control). The weight, length and width of the C. sinensis fruits were measured. A total of three soil samples were collected around the C. sinensis trees where the fruits were collected into well labeled polythene bags and thereafter taken to laboratory for analysis. Pb concentrations in C. sinensis and soil samples were analysed using atomic absorption spectrophotometer (AAS). The concentration of Pb in the air was measured for 14 days using Aeroquel 500. The significant relationship between Pb concentration in the C. sinensis fruits, soil and air was determined using Spearman's rank correlation. Findings showed that the mean weight and width of C. sinensis fruits were highest in the residential landuse while the mean length of C. sinensis fruits was highest in the industrial landuse. However, the mean Pb concentration in the C. sinensis fruit was highest in the industrial landuse ($0.46{\pm}0.15mg\;kg^{-1}$), commercial landuse ($0.33{\pm}0.09mg\;kg^{-1}$) and the least was found in the natural forest ($0.25{\pm}0.06mg\;kg^{-1}$). The mean Pb concentration in the soil was highest in the industrial landuse ($0.177{\pm}0.16mg\;kg^{-1}$) and commercial landuse ($0.121{\pm}0.10mg\;kg^{-1}$). However, the mean Pb concentration in the air was highest in the industrial landuse ($0.85{\pm}0.09mg\;kg^{-1}$) and followed by commercial landuse ($0.30{\pm}0.17mg\;kg^{-1}$). The correlations between the Pb concentration in the C. sinensis fruit and soil (r=0.768, p<0.05) and air (r=0.642, p<0.05) were significant. The study concluded that the Pb concentration in the C. sinensis fruits was higher than the WHO standard; hence people should be discouraged to consume them, especially those from the industrial and commercial areas.

해수중 카드뮴, 구리, 납, 아연 및 수은의 원자흡광정량법 (DETERMINATION OF CADMIUM, COPPER, LEAD, ZINC AND MERCURY IN SEA WATER BY ATOMIC ABSORPTION SPECTROPHOTOMETRY)

  • 원종훈;박청길;양한섭
    • 한국수산과학회지
    • /
    • 제9권3호
    • /
    • pp.169-175
    • /
    • 1976
  • 해수중 ppb 정도의 카드뮴, 구리, 납, 아연 및 수은 정량을 위한 용매추출-원자흡광법 및 환원기화법에 의한 무염원자흡광법을 검토했다. 용매추출 때의 최적 pH는 pH4-7였으며 용매로는 MIBK가 가장 효율이 좋았으며 킬레이트제로는 DDTC가 APDC보다 추출율 및 기타 조건이 유리했다. 즉 $1\iota$ 해수를 사용하여 pH4-5에서 DDTC-MIBK로 추출하여 아세칠렌-공기불꽃 중에 흡입시켜 흡광도를 측정하는 방법으로 해수시료를 분석한 결과 정밀저는 표준편차로 카드뮴 0.058 ppb, 구리 0.084 ppb, 납 0.44ppb였다, 아연은 $1\iota$ 시수를 사용했을 때는 블랭크값이 녀무 크게 나오고 그 정밀도가 극히 좋지 않았다. 시수량을 200ml로 했을 때는 비교적 정밀도가 좋았으며 표준편차로서 2.49 ppb였다. 수은은 시수 500ml을 황산-과망간산칼리움 분해법으로 분해시켜 염화제1주석으로 수은을 환원기화시켜 흡광도를 측정했으며 그 정밀도는 0.005 ppb였다. 이상의 방법으로 측정할 수 있는 각 금속의 정량감도는 카드뮴 $0.08\;ppb/\%$, 구리$0.15\;ppb/1\% $, 납 $0.6\;ppb/1\%$, 아연 $1.2\;ppb/1\%$, 수은 $0.01\;ppb/1\%$였다. 채수후 분석시까지의 시수보관에 따른 각 금속의 농도변화는 시수$1\iota$에 대해 질산 10ml 정도 넣어 pH 1.5 부근으로 하며 플리에칠렌병에서 보관한 결과 카드뮴, 구리, 납, 수은은 30일정도 까지는 안정하였으며 아연은 불규칙한 심한 변동을 보였다.

  • PDF

0.96(Na0.5K0.5)NbO3-0.04(Ba(1-x)Srx)TiO3 무연 세라믹스의 유전 및 압전 특성 (Dielectric and piezoelectric properties of 0.96(Na0.5K0.5)NbO3-0.04(Ba(1-x)Srx)TiO3 lead-free ceramics)

  • 김미로;윤석진;최지원
    • 센서학회지
    • /
    • 제19권2호
    • /
    • pp.155-159
    • /
    • 2010
  • 0.96$(Na_{0.5}K_{0.5})NbO_3$-0.04$(Ba_{(1-x)}Sr_x)TiO_3$ lead free piezoelectric ceramics were synthesized to enhance the piezoelectric properties of (Na,K)$NbO_3$. The systhesis and sintering method were the conventional solid state reaction method and general sintering method in air atmosphere. The polymorphic phase transition(PPT) was observed at all composition(0 $\leq$ x $\leq$ 0.05) when $(Ba_{(1-x)}Sr_x)TiO_3$ were added in the $(Na_{0.5}K_{0.5})NbO_3$. As Sr concentration was increased, grain size, dielectric loss(tan$\delta$) and mechanical quality factor($Q_m$) were decreased and piezoelectric constant($d_{33}$) and electromechanical coupling factor($k_p$) were increased within a limited value. The optimized piezoelectric and properties, $d_{33}$, $k_p$, $Q_m$, and tand, of 0.96$(Na_{0.5}K_{0.5})NbO_3$-0.04$(Ba_{(1-x)}Sr_x)TiO_3$ were 139 pC/N, 0.31 %, 95, 0.04 at the composition of x=0.04.

An Experimental Study on the Effects of ...an Inserted Coil on Flow Patterns pd. Beat Transport Performances for a Horizontal Rotating Heat Pipe

  • Lee, Jin-Sung;Kim, Chul-Ju;Kim, Bong-Hun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제8권1호
    • /
    • pp.50-61
    • /
    • 2000
  • The effects of an inserted coil on flow . patterns and heat transfer performance for a horizontal rotating heat pipe have been studied experimentally. Especially, the present study is to see an internally inserted helical coil inside a RHP would lead to the same kind of results as internal fins. Visualization test conducted for an acryl tube, charged water with at a volumetric rate of 20%. When the flow kept pool regime at a low rpm(less than 1,000rpm), the movement of coil forced the water to flow in axial direction. But this pumping effect of coil disappeared, when the pool regime changed to annular one which could be created by increasing rpm. The pumping effects for RHP with an inserted coil resulted in the enhancement in both condensation heat transfer coefficient and heat transport limitation, as obtained in case of using internal fins. But all these effects became negligible in the range of higher rpm(above 1,000-1,200) with the transition of flow regime to annular flow.

  • PDF