• Title/Summary/Keyword: Lead in air

Search Result 621, Processing Time 0.032 seconds

Impact of PSI-KIT Nitriding model on hypothetical Spent Fuel Pool accident simulation

  • Mateusz Malicki;Terttaliisa Lind
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2504-2515
    • /
    • 2023
  • In past years the Paul Scherrer Institute (PSI, Switzerland) and the Karlsruhe Institue of Technology (KIT, Germany)) collaborated to develop a model to account for the active role of nitrogen in the air oxidation of a Zircalloy cladding. The "PSI-KIT Nitriding Model for Zirconium based Fuel Cladding" model was implemented at PSI into PSI-MELCOR 1.8.6. In order to make a preliminary evaluation of the effect of the new model on the evolution of full-scale spent fuel pool accidents, one spent fuel pool event was analyzed using the PSI research version of PSI-MELCOR 1.8.6, which includes the nitriding model. To adapt an existing input deck for the calculations, a sensitivity study was conducted to find an optimal nodalization for the analyses. The nitriding model results were compared to those calculated with the MELCOR 1.8.6-PSI without the new nitriding model. The results demonstrate the effect of the nitriding reactions in spent fuel pool accident progression. Moreover, they confirm the impact of ZrN formation during cladding oxidation in air when the oxidation reactions lead to oxygen starvation inside the fuel assemblies. The nitriding reaction led to higher chemical heat generation during the accident and to an earlier failure of the cladding than when the effect of nitrogen reactions was not considered. It should be noted that the nitriding model, as implemented in the PSI version of MELCOR 1.8.6 has not yet been conclusively validated. Thereby the results presented in this paper should be treated as a preliminary demonstration of the capabilities of the model.

Relationship Between Exposure to Air Pollutants and Aggravation of Childhood Asthma : A Meta-Analysis (메타분석을 적용한 대기오염과 소아 천식 관련 입원의 상관성 평가 연구)

  • Cho, Yong-Sung;Kim, Ho;Lee, Jong-Tae;Hyun, Youn-Joo;Kim, Yoon-Shin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.5
    • /
    • pp.425-437
    • /
    • 2001
  • This study is based on the uses meta-analysis methodology to examine the statistical consistency and importance of random variation among results of epidemiologic studies between air pollutants exposure and childhood asthma. Studies for this meta-analysis were conducted by reviewing previous results and by asking researcher active in this field for recommendations. Overall, 10 cases of air pollutants exposures and childhood asthma were reviewed. A variety of statistical methods for meta-analysis have been used to assess the combined effects, to identify heterogeneity, and to provide a single summary risk estimate based on a set of simiar epidemiologic studies. In this study, classification of exposure metircs on air environmental epidemiologic studies are reported for (1) aggravation of childhood asthma by a 50 ppb increase SO$_2$(6 individual studies); (2) aggravation of childhood asthma by a 50 ppb increase NO$_2$(5 individual studies); (3) aggravation of childhood asthma by a 50 ppb increase $O_3$(7 individual studies); (4) aggravation of childhood asthma by a 10$\mu\textrm{g}$/m$^3$increase PM$_{10}$ (4 individual studies); (5) aggravation of childhood asthma by a 1 ppm increase CO (2 individual studies); and (6) comparison of results between a Korean study results and this meta-analytic study. Results of this study indicated that an inverse-variance weighted pooling of the hospital admission risk at a 1ppm increment of CO levels was 1.12% (95% CI : 1.01 ~ 1.24). The hospital admission risk was estimated to increase 5% (95% CI : 1.02~1.08), 6%(95% CI : 1.04~1.09), and 5% (95% CI : 1.02~1.09) with each 50ppb increase of SO$_2$, NO$_2$, and $O_3$, respectively. In addition, our results lead to a small but significant elevation in risk of 2% (RR = 1.02, 95% CI = 1.01~1.04) with each 10$\mu\textrm{g}$/m$^3$increase of PM$_{10}$ among 4 individual studies. We found a small elevation in risk of childhood asthma, and pooled results of 10 epidemiologic studies of childhood asthma using increase a cut-off-point levels of air pollutants showed a few pieces of evidence. The results of this meta-analysis suggested that air pollution associated with an increased incidence of childhood asthma. According to this study, relationship between exposure to air pollutants and childhood asthma in Korea seem to be high than results of this meta-analysis.sis.

  • PDF

Estimation of Food Miles and CO2 Emissions of Imported Food (수입 음식료품의 푸드 마일리지 및 이산화탄소 배출량 산정)

  • Ju, Ok-Jung;Lee, Jae-Bum;Seong, Mi-Ae;Kim, Su-Yeon;Ryu, Ji-Yeon;Kim, Dai-Gon;Hong, Yoo-Deog
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.1
    • /
    • pp.57-68
    • /
    • 2010
  • Increase in greenhouse gas emissions during the last century has led to remarkable changes in our environment and climate system. Many policy measures have been developed to reduce greenhouse gas emissions across the world, many of which require our lifestyle changes from energy-intensive to energy-saving. One of the changes in our living patterns is to consider food miles. A food mile is the distance food travels from where it is produced to where it is consumed. Providing information of food miles will help people choose low mileage food, helping promote a "green consumption" action and lead to a low carbon society with emission reduction systems. In this study, 10 items are selected from 23 Harmonized commodity description and 2-digit coding system (HS) to estimate their food miles, and $CO_2$ emissions released in the transportation of imported food. For the estimation, four countries are chosen-Korea, Japan, United Kingdom (UK) and France, with Korea and Japan's 2001, 2003, and 2007 trade statistics and UK and France's 2003 and 2007 trade statistics used. As a result, Korea showed in 2007 the highest level of food miles and $CO_2$ emissions per capita among 4 countries. That suggests that Korea should make an effort to purchase local food to reduce food miles and use low-carbon vehicles for food transport, contributing to reducing greenhouse gas emissions.

A Study on the Optimum Cooling Condition of the Underground Power Transmission Cable Equipped with a Separate Pipe Cooling System (간접냉각이 이용된 지중송전케이블의 적정냉각조건에 관한 연구)

  • Park, M.H;Che, G.S.;Seo, J.Y.;Kim, J.G.;Lee, Jae-Heon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.4
    • /
    • pp.263-276
    • /
    • 1992
  • The transmission current in a power cable is determined under the condition of separate pipe cooling. To this end, the thermal analysis is conducted with the standard condition of separate pipe cooling system, which constitutes one of the underground power transmission system. The changes of transmission current in a power cable with respect to the variation of temperatures and flow rates of inlet cooling water as well as the cooling spans are also determined. As a consequnce, the corresponding transmission current is shown to vary within allowable limit, resulting in the linear variation of the current for most of the cable routes. The abrupt changes of current, however, for the given flow rate of inlet cooling water in some cooling span lead to the adverse effects on the smooth current transmission within the underground power transmission system. In practice, it is expected that the desinging of the separate pipe cooling system in conjunction with the evaluation of system capacity should take into account the effects of design condition on the inlet cooling flow rate.

  • PDF

Non-contact monitoring of 3-dimensional vibrations of bodies using a neural network

  • Ha, Sung Chul;Cho, Gyeong Rae;Doh, Deog-Hee
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.10
    • /
    • pp.1011-1016
    • /
    • 2015
  • Gas piping systems in power plants and factories are always influenced by the mechanical vibrations of rotational machines such as pumps, blowers, and compressors. Unusual vibrations in a gas piping system influence possible leakages of liquids or gases, which can lead to large explosive accidents. Real-time measurements of unusual vibrations in piping systems in situ prohibit them from being possible leakages owing to the repeated fatigue of vibrations. In this paper, a non-contact 3-dimensional measurement system that can detect the vibrations of a solid body and monitor its vibrational modes is introduced. To detect the displacements of a body, a stereoscopic camera system is used, through which the major vibration types of solid bodies (such as X-axis-major, Y-axis-major, and Z-axis-major vibrations) can be monitored. In order to judge the vibration types, an artificial neural network is used. The measurement system consists of a host computer, stereoscopic camera system (two-camera system, high-speed high-resolution camera), and a measurement target. Through practical application on a flat plate, the measured data from the non-contact measurement system showed good agreement with those from the original vibration mode produced by an accelerator.

An Experimental Study of the 2-stage Gifford-McMahon Cryorefrigerator (2단 Gifford-McMahon 극저온냉동기의 특성실험)

  • Park, S.J.;Koh, D.Y.;Yoo, C.J.;Kim, E.J.;Choi, H.O.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.3
    • /
    • pp.198-206
    • /
    • 1993
  • Experimental results of two stage Gifford-McMahon cryorefrigerator are described. In-prototype experiments, drive mechanism is Scotch Yoke type driven by stepping motor, copper meshes and lead balls are used for regenerator's materials in the first stage and the second stage, respectively. To find optimal conditions of the cryopump, no load temperature and refrigeration capacity according to the variation of cycle frequency and operating pressure are measured, and the cool down and load characteristics at particular cycle frequencies are presented. In general, as the cycle frequency is lowered, no load temperature is dropped but refrigeration capacity is diminished. As the representative result, in a case that the cycle frequency is 70rpm and steady state pressure is 14 atm, no load temperature of second stage is lowered to 10.5K in 55 minuters, and in this situation the refrigeration capacity of the first stage is 42W at 80K, that of the second stage is 11 W at 20K.

  • PDF

Lead (Pb) Concentrations in Soil, Air and Fruits of Sweet Orange (Citrus sinensis L. Osbeck) in Selected Landuse in Port Harcourt Metropolis, Rivers State, Nigeria

  • Eludoyin, Olatunde Sunday;Odimegwu, Vitus Chinonso
    • Journal of Forest and Environmental Science
    • /
    • v.34 no.4
    • /
    • pp.284-292
    • /
    • 2018
  • The study investigated the concentrations of Pb in soil, air and fruit of C. sinensis in selected landuse types in Port Harcourt Metropolis, Rivers State, Nigeria. Five fruits of C. sinensis were collected randomly in residential, commercial, industrial and natural forest (control). The weight, length and width of the C. sinensis fruits were measured. A total of three soil samples were collected around the C. sinensis trees where the fruits were collected into well labeled polythene bags and thereafter taken to laboratory for analysis. Pb concentrations in C. sinensis and soil samples were analysed using atomic absorption spectrophotometer (AAS). The concentration of Pb in the air was measured for 14 days using Aeroquel 500. The significant relationship between Pb concentration in the C. sinensis fruits, soil and air was determined using Spearman's rank correlation. Findings showed that the mean weight and width of C. sinensis fruits were highest in the residential landuse while the mean length of C. sinensis fruits was highest in the industrial landuse. However, the mean Pb concentration in the C. sinensis fruit was highest in the industrial landuse ($0.46{\pm}0.15mg\;kg^{-1}$), commercial landuse ($0.33{\pm}0.09mg\;kg^{-1}$) and the least was found in the natural forest ($0.25{\pm}0.06mg\;kg^{-1}$). The mean Pb concentration in the soil was highest in the industrial landuse ($0.177{\pm}0.16mg\;kg^{-1}$) and commercial landuse ($0.121{\pm}0.10mg\;kg^{-1}$). However, the mean Pb concentration in the air was highest in the industrial landuse ($0.85{\pm}0.09mg\;kg^{-1}$) and followed by commercial landuse ($0.30{\pm}0.17mg\;kg^{-1}$). The correlations between the Pb concentration in the C. sinensis fruit and soil (r=0.768, p<0.05) and air (r=0.642, p<0.05) were significant. The study concluded that the Pb concentration in the C. sinensis fruits was higher than the WHO standard; hence people should be discouraged to consume them, especially those from the industrial and commercial areas.

DETERMINATION OF CADMIUM, COPPER, LEAD, ZINC AND MERCURY IN SEA WATER BY ATOMIC ABSORPTION SPECTROPHOTOMETRY (해수중 카드뮴, 구리, 납, 아연 및 수은의 원자흡광정량법)

  • WON Jong Hun;PARK Chung Kil;YANG Han Serb
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.9 no.3
    • /
    • pp.169-175
    • /
    • 1976
  • A solvent extraction-atomic absorption spectrophotometry for determination of trace amount of cadmium, copper, lead and zinc and a flameless atomic absorption spectrophotometry for mercury in sea water were studied. The optimum pH range for solvent extraction was pH 4-7. A better solvent extraction efficiency was obtained with MIBK solvent than nitrobenzene, benzene, isoamylalcohol, n-buthylacetate. DDTC was more advantageous than APDC as chelating agent. The metals, chelated with DDTC and concentrated into MIBK by solvent extraction with a volume of $1\iota$ of sea water for cadmium, copper and lead, and 200m1 for zinc, were determined simultaneously by atomic absorption spectrophotometry. For mercury determination, 500ml of sea water was digested with permanganate-sulfuric acid and mercury( II ) was reduced by stannous chloride and aerated the solution with air pump until the absorbance reached a constant value. The precisions, in standard deviation, of these methods were 0.058ppb for cadmium, 0.084 ppb for copper, 0.44ppb for lead, 2.49ppb for zinc and 0.08 ppb for mercury. The sensitivities, expressed in $ppb/1\%$ absorption, were 0.058 ppb cadmium, 0. 15 ppb copper, 0.6 ppb lead, 1.2 ppb zinc and 0.01 ppb mercury respectively. No significant adsorption on the wall of polyethylene sample bottle occurred during 30 days of storing by acidification to pH 1.5 with nitric acid except zinc. Poor reproducibility was found for zinc with this method.

  • PDF

Dielectric and piezoelectric properties of 0.96(Na0.5K0.5)NbO3-0.04(Ba(1-x)Srx)TiO3 lead-free ceramics (0.96(Na0.5K0.5)NbO3-0.04(Ba(1-x)Srx)TiO3 무연 세라믹스의 유전 및 압전 특성)

  • Kim, Mi-Ro;Yoon, Seok-Jin;Choi, Ji-Won
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.155-159
    • /
    • 2010
  • 0.96$(Na_{0.5}K_{0.5})NbO_3$-0.04$(Ba_{(1-x)}Sr_x)TiO_3$ lead free piezoelectric ceramics were synthesized to enhance the piezoelectric properties of (Na,K)$NbO_3$. The systhesis and sintering method were the conventional solid state reaction method and general sintering method in air atmosphere. The polymorphic phase transition(PPT) was observed at all composition(0 $\leq$ x $\leq$ 0.05) when $(Ba_{(1-x)}Sr_x)TiO_3$ were added in the $(Na_{0.5}K_{0.5})NbO_3$. As Sr concentration was increased, grain size, dielectric loss(tan$\delta$) and mechanical quality factor($Q_m$) were decreased and piezoelectric constant($d_{33}$) and electromechanical coupling factor($k_p$) were increased within a limited value. The optimized piezoelectric and properties, $d_{33}$, $k_p$, $Q_m$, and tand, of 0.96$(Na_{0.5}K_{0.5})NbO_3$-0.04$(Ba_{(1-x)}Sr_x)TiO_3$ were 139 pC/N, 0.31 %, 95, 0.04 at the composition of x=0.04.

An Experimental Study on the Effects of ...an Inserted Coil on Flow Patterns pd. Beat Transport Performances for a Horizontal Rotating Heat Pipe

  • Lee, Jin-Sung;Kim, Chul-Ju;Kim, Bong-Hun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.8 no.1
    • /
    • pp.50-61
    • /
    • 2000
  • The effects of an inserted coil on flow . patterns and heat transfer performance for a horizontal rotating heat pipe have been studied experimentally. Especially, the present study is to see an internally inserted helical coil inside a RHP would lead to the same kind of results as internal fins. Visualization test conducted for an acryl tube, charged water with at a volumetric rate of 20%. When the flow kept pool regime at a low rpm(less than 1,000rpm), the movement of coil forced the water to flow in axial direction. But this pumping effect of coil disappeared, when the pool regime changed to annular one which could be created by increasing rpm. The pumping effects for RHP with an inserted coil resulted in the enhancement in both condensation heat transfer coefficient and heat transport limitation, as obtained in case of using internal fins. But all these effects became negligible in the range of higher rpm(above 1,000-1,200) with the transition of flow regime to annular flow.

  • PDF