• 제목/요약/키워드: Layered Structures

검색결과 503건 처리시간 0.028초

무선랜 대역용 Ba0.5Sr0.5TiO3 박막을 이용한 가변 대역 통과 여파기 (Tunable Band-pass Filters using Ba0.5Sr0.5TiO3 Thin Films for Wireless LAN Application)

  • Kim, Ki-Byoung;Yun, Tae-Soon;Lee, Jong-Chul;Kim, Il-Doo;Lim, Mi-Hwa;Kim, Ho-Gi;Kim, Jong-Heon;Lee, Byungje;Kim, Na-Young
    • 한국전자파학회논문지
    • /
    • 제13권8호
    • /
    • pp.819-826
    • /
    • 2002
  • 본 논문은 $Ba_{0.5}$Sr$_{0.5}$TiO$_3$(BST) 박막을 이용한 대역 통과 여파기를 설계, 제작한 것으로 마이크로스트립 과 코플래너 웨이브가이드(CPW), CBCPW 전송 선로 구조에서 각 구조의 여파기 특성을 비교하였다. 제작된 여파기는 전압 0V 인가시 각각 6.4 GHz, 6.14 GHz, 6.04 GHz의 중심 주파수와 6 dB, 4.41 dB, 5.41 dB의 삽입 손실이 측정되었으며, 40V 인가시 중심 주파수 6.61 GHz, 6.31 GHz, 6.21 GHz와 삽입 손실 7.33 dB, 5.83 dB, 6.83 dB로 나타났다. 본 논문에서 제작된 각각의 대역 통과 야파기는 가변 범위가 약 3 % - 8 %이며, 무선랜 대역에 응용할 수 있도록 설계 및 제작되었다.다.

석조문화재 기초지반 파악을 위한 모형지반에서의 탐사기법 적용 (Application of Geophysical Survey to the Geological Engineering Model for the Effective Detection in Foundation of Stone Relics)

  • 김만일;이창주;김종태;김지수;김사덕;정교철
    • 지질공학
    • /
    • 제18권4호
    • /
    • pp.537-543
    • /
    • 2008
  • 지표 근접 지질조사 및 매설물 조사에 응용되는 GPR탐사를 통해 석조문화재 기초지반을 효과적으로 탐지하기 위해 토양층과 자갈층이 교호하는 지질공학적인 모형지반(천부 지층구조)을 3 m의 깊이로 재건하여 GPR탐사 및 탄성파 굴절법 탐사를 측선별로 수행하였다. GPR탐사에 사용되는 주파수를 다양하게 적용하여 주파수별 분해능에 따른 모형지반의 경계구분을 확인하였다. 그 결과 100 MHz의 주파수 대역에서 분해능은 낮지만 가장 효과적으로 지층경계를 구분할 수 있었으며, 225 MHz, 450 MHz, 900 MHz의 고주파수 대역을 사용한 결과에서는 전자파의 감쇠로 인해 하부경계를 구분할 수 없었으나 천부의 분해능은 향상되었다. 이로부터 심부에 대한 100 MHz의 자료와 천부에 대한 고주파수 단면도를 조합하여 최종단면도를 얻었다. 탄성파 굴절법 탐사에서는 모형지반의 정확한 경계 및 지층 간 경계면은 파악할 수 없었으나, 모형지반이 위치하고 있는 구간에서의 등속도선이 주변 지역에 비해 상대적으로 깊은 심도까지 분포하는 것으로 볼 때 원지반과 모형 경계의 속도 대비를 파악할 수 있는 것으로 나타났다.

콘크리트내의 이중구조와 시간의존성을 고려한 염화물 해석기법의 개발 (Analysis Technique for Chloride Penetration using Double-layer and Time-Dependent Chloride Diffusion in Concrete)

  • 문진만;김진영;김영준;오경석;권성준
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권5호
    • /
    • pp.83-91
    • /
    • 2015
  • 콘크리트 표면의 상태에 따라 염화물은 증가 또는 감소하게 되며 이는 철근부식 및 내구수명에 매우 중요한 인자가 된다. 콘크리트의 내구성 저하를 방지하기 위해 표면함침과 같이 많은 표면강화 기술이 개발되었으나 이중 콘크리트 구조와 확산계수의 시간의존성을 고려한 염화물 해석방법은 매우 제한적이다. 본 논문에서는 표면 강화된 이중구조 콘크리트에 대해 시간의존성 확산계수를 도입하여 염화물 해석기법을 제안하였으며, 역해석을 통하여 기존의 실험결과와 비교하였다. 2년간 비말대, 해수중, 조석대 상태에 노출된 표면 함침된 콘크리트 시편에 대해 표면염화물량과 확산계수를 도출하고 Life-365에서 제안한 확산계수 식과 비교 분석하였다. 시간의존성을 고려한 결과 비말대 시편의 오차는 0.28에서 0.20 수준으로, 조석대 시편은 0.29에서 0.11 수준으로, 해수중에서는 0.54에서 0.40 수준으로 오차가 감소함을 알 수 있었다. 또한 Life365에서 사용되는 확산계수식을 사용할 경우, 과다한 확산계수로 인해 상대오차가 커지고 높은 침투깊이(e)와 낮은 확산계수비($D_1/D_2$)를 필요로 함을 알 수 있다.

압전 세라믹을 이용한 전기 발전 (Electric Power Generation from Piezoelectric Ceramics)

  • 백종후;신범승;임은경;김창일;임종인;이영진;최병현;김동국
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.304-304
    • /
    • 2006
  • 기계적 에너지를 전지적 에너지로 변환하는 에너지 변환소자인 압전 세라믹스는 액츄에이터, 변압기, 초음파모터, 초음파 소자 및 각종 센서로 응용되고 있으며, 그 응용분야는 크게 종가하고 있다. 최근 이러한 에너지변환 소자를 앞으로 도래하는 유비쿼터스 무선 모바일 시대의 휴대용 전자제품, 즉 Wearable 컴퓨터, MP3, GSM, Bluetooth 등의 정보통신기기, Robotics, 항공우주, 자동차, 의료, 건축, MEMS 분야 등의 대체 에너지원으로 응용하기 위한 연구가 진행되고 있다. 특히 인간의 동작등과 같은 일상적인 동작(Typing, U. limbbing, Breathing, Walking 등)으로 필요한 전력을 얻을 수 있고, 세라믹 소자를 이용하기 때문에 전자노이즈가 발생되지 않을 뿐 아니라 반영구적으로 사용할 수가 있어서, 기존 이차전지, 연료전지를 대체 또는 보완 할 수 있는 방안도 검토되고 있다. 따라서 본 연구에서는 향후 응용 가능성이 큰 압전 발전 시스템을 제작하기 위해서 압전특성이 우수한 조성시스템 설계, 바이몰프 형태의 압전액츄에이터 제작, 그리고 발전시스템의 회로설계를 수행하였다.

  • PDF

콘크리트 건축물의 모놀리스적 표현특성에 관한 연구 단열경량골재콘크리트를 중심으로 (A Study on Monolithic Expression Characteristics of Concrete Buildings With focus on insulated lightweight aggregate concrete)

  • 원경섭
    • 한국산학기술학회논문지
    • /
    • 제19권12호
    • /
    • pp.363-373
    • /
    • 2018
  • 오늘날 다변화된 사회에서 어떤 스타일의 건물이 동시대를 대표하는 건축적 양식인지 알기 어렵다. 그 중에서 모놀리스적 스타일의 건물에서 드러나는 단순함은 현대의 지극히 복잡한 사회구조와 대칭점을 이루며 그 가치를 인정받을 수 있다. 본 논문에서는 21세기 초반 단열경량골재콘크리트가 사용된 건물의 분석을 통해서 모놀리스적 표현에 대한 개념정의와 그 특징들이 공간 및 형태 그리고 건축구법에서 어떻게 표현되고 있는지에 대해 연구하였다. 여러 재료가 층을 이루어 구성되는 다층적 방식의 외벽시스템과는 달리, 단열경량골재콘크리트에 의한 외벽은 단일재료로서 콘크리트를 사용하여 거푸집을 빈틈없이 채워서 만들어진 덩어리 형태이며 그 자체로 모놀리스적이다. 이러한 점은 동일한 재료에 의한 내외부공간의 동질성, 고형(固形)으로서 표면의 연속성, 스테레오토믹적(stereotomic) 구축방식의 공간적 특성, 노출콘크리트사용에 의한 물질성의 표현, 덩어리와 공간 사이의 대비적 특성을 가진 공간을 만들어 낸다. 그리고 현대건축의 다층적 외벽 방식의 모놀리스적 건축에 대한 담론을 외부로 드러나는 형상적 특징과 더불어 구조와 재료, 그리고 그것이 공간에 끼치는 영향에 까지 논의의 범위를 넓힐 수 있는 기회를 제공한다.

PES 여과막의 물리적 막오염 개선을 위한 기공 구조 개선 연구 (Improving Physical Fouling Tolerance of PES Filtration Membranes by Using Double-layer Casting Methods)

  • 김창헌;유영민;김인철;남승은;이정현;백영빈;조영훈
    • 멤브레인
    • /
    • 제33권4호
    • /
    • pp.191-200
    • /
    • 2023
  • Polyethersulfone (PES)은 친수성과 상분리법의 용이성 덕분에 수처리 및 정제 분야에서 정밀여과 및 한외여과막 소재로 일반적으로 사용된다. 그러나, 비용매 유도 상분리법으로 제조된 PES 분리막, 특히 지지체가 없는 여과막의 경우 도프의 조성과 기재의 특성에 따라 여과막 하부에 낮은 기공도를 갖는 치밀층이 형성되기 쉽고, 이러한 치밀층으로 인해 수투과 저항이 증가하고 오염물질의 쌓임에 의한 막오염이 일어난다. 본 연구에서는 PES 여과막 제조 시 상전이 과정의 수축으로 인해 분리막 하부에 물이 침투하여 치밀층을 형성, 심각한 막오염을 유발할 수 있음을 확인하였다. 동일한 선택층을 갖는 PES 여과막을 단일층 및 이중층 캐스팅법으로 각각 제조하여 하부 치밀층이 여과막의 투과성능 및 막오염에 미치는 영향을 파악하고자 하였다. 하부 치밀층이 없는 이중층 캐스팅된 여과막은 기존 여과막 대비 높은 투과성능 및 막오염에 대한 저항성을 보였으며, 이를 통해 다공성 여과막의 내오염성을 향상시키기 위한 표면 기공도 및 기공 구조 등 물리적 구조의 최적화가 중요함을 확인하였다.

석탄화력발전소 호흡성분진 작업환경 평가 전략 사례에 관한 연구 (A Study on Occupational Environment Assessment Strategies for Respirable Particulate Matter at Coal-Fired Power Plants )

  • 이은승;이윤근;신동일
    • 한국산업보건학회지
    • /
    • 제33권3호
    • /
    • pp.375-383
    • /
    • 2023
  • Objectives: Coal-fired power plants feature diverse working conditions, including multi-layered employment structures and irregular work cycles due to outsourcing and non-standardized tasks. The current uniform occupational environment measurement systems have limitations in accurately assessing and evaluating these varied conditions. This study aims to propose alternative measurement and assessment strategies to supplement existing methods. Methods: Major domestic coal-fired power plants were selected as the study targets. To prepare for the study and establish strategies, work processes were identified and existing occupational environment measurement results were compared and analyzed. The study proceeded by employing three strategies: specific exposure groups (SEGs) measurement, continuous monitoring, and supplementary measurements, which were then compared and discussed. Results: Previous exposure index evaluations (5,268 cases) indicated that crystalline silica, a type of respirable particulate matter, had detection limits below the threshold (non-detectable) in 82.6% (4,349 cases) of instances. Exposures below 10% of the exposure limit were observed at a very low concentration of 96.1%. Similar exposure group measurements yielded results where detection limits were below the threshold in 38.2% of cases, and exposures below 10% of the limit were observed in 70.6%. Continuous monitoring indicated detection limits below the threshold in 12.6% of cases, and exposures below 10% of the limit were observed in 75.6%. Instances requiring active workplace management accounted for more than 30% of cases, with SEGs at 11.8% (four cases), showing a higher proportion compared to 3.0% (four cases) in continuous monitoring. For coal dust, exposures below 10% of the limit were highest in legal measurements at 90.2% (113 cases), followed by 74.0% (91 cases) in continuous monitoring, and 47.0% (16 cases) in SEGs. Instances exceeding 30% were most prevalent in SEGs at 14.7% (five cases), followed by legal measurements at 5.0% (eight cases), and continuous monitoring at 2.4% (three cases). When examining exposure levels through arithmetic means, crystalline silica was found to be 104.7% higher in SEGs at 0.0088 mg/m3 compared to 0.0043 mg/m3 in continuous monitoring. Coal dust measurements were highest in SEGs at 0.1247 mg/m3, followed by 0.1224 mg/m3 in legal measurements, and 0.0935 mg/m3 in continuous monitoring. Conclusions: Strategies involving SEGs measurement and continuous monitoring can enhance measurement reliability in environments with irregular work processes and frequent fluctuations in working conditions, as observed in coal-fired power plants. These strategies reduce the likelihood of omitting or underestimating processes and enhance measurement accuracy. In particular, a significant reduction in detection limits below the threshold for crystalline silica was observed. Supplementary measurements can identify worker exposure characteristics, uncover potential risks in blind spots of management, and provide a complementary method for legal measurements.

Layered structure of sialoliths compared with tonsilloliths and antroliths

  • Buyanbileg Sodnom-Ish;Mi Young Eo;Yun Ju Cho;Mi Hyun Seo;Hyeong-Cheol Yang;Min-Keun Kim;Hoon Myoung;Soung Min Kim
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제50권1호
    • /
    • pp.13-26
    • /
    • 2024
  • Objectives: The aim of this study was to perform a comparative analysis of the ultrastructural and chemical composition of sialoliths, tonsilloliths, and antroliths and to describe their growth pattern. Materials and Methods: We obtained 19 specimens from 18 patients and classified the specimens into three groups: sialolith (A), tonsillolith (B), and antrolith (C). The peripheral, middle, and core regions of the specimens were examined in detail by histology, micro-computed tomography (micro-CT), scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy, and transmission electron microscopy (TEM). Results: In the micro-CT, group A showed alternating radiodense and radiolucent layers, while group B had a homogeneous structure. Group C specimens revealed a compact homogeneous structure. Histopathologically, group A showed a laminated, teardrop-shaped, globular structure. Group B demonstrated degrees of immature calcification of organic and inorganic materials. In group C, the lesion was not encapsulated and showed a homogeneous lamellar bone structure. SEM revealed that group A showed distinct three layers: a peripheral multilayer zone, intermediate compact zone, and the central nidus area; groups B and C did not show these layers. The main elemental components of sialoliths were O, C, Ca, N, Cu, P, Zn, Si, Zr, F, Na, and Mg. In group B, a small amount of Fe was found in the peripheral region. Group C had a shorter component list: Ca, C, O, P, F, N, Si, Na, and Mg. TEM analysis of group A showed globular structures undergoing intra-vesicular calcification. In group B, bacteria were present in the middle layer. In the outer layer of the group C antrolith, an osteoblastic rimming was observed. Conclusion: Sialoliths had distinct three layers: a peripheral multilayer zone, an intermediate compact zone and the central nidus area, while the tonsillolith and antrolith specimens lacked distinct layers and a core.

포항지역 지열 개발을 위한 3 차원 자기지전류 탐사 (Three-dimensional magnetotelluric surveys for geothermal development in Pohang, Korea)

  • 이태종;송윤호;내전이홍
    • 지구물리와물리탐사
    • /
    • 제10권1호
    • /
    • pp.89-97
    • /
    • 2007
  • 포항 저온 지열개발 지역에서 지하구조 규명 및 파쇄대 탐지를 목적으로 3 차원 자기지전류 (MT)탐사를 실시하였다. 현장에서 약 480 km 떨어진 일본 큐슈 지역에 원거리 기준점을 설치하여 양질의 자료를 획득하였다. 대상지역이 바다에 인접한 관계로 바다의 효과를 고려한 3 차원 모델링과 역산을 수행하여 측정된 MT 탐사자료에 포함된 바다효과를 고찰하였다. 그 결과 포항지역에 인접한 바다는 해안선으로부터의 거리에 따라 $1\;Hz{\sim}0.2\;Hz$ 이하의 주파수대에 주로 영향을 미치며, 특히 영일만에 인접한 남동쪽의 측점들이 바다의 영향을 가장 크게 받은 것으로 나타났다. 약 2km 심도 이하의 천부에서는 인접한 바다를 3 차원 역산에 포함시킨 경우와 그렇지 않은 경우가 매우 비슷한 결과를 보였으나, 이보다 심부의 경우는 바다를 포함시키지 않은 3 차원 역산에서 대상지역의 남동쪽에 저비저항 구조가 나타나는데 이는 인접 바다의 영향이 투영되어 나타난 것으로 보인다. 시추 결과 및 역산에 의한 전기비저항 구조를 비교한 결과 대상지역의 지하를 크게 다섯 개의 층으로 구분할 수 있었다. 즉: 1) 10 ohm-m 이하의 전기비저항을 보이는 반고결이암층이 대상지역 북쪽에서는 지표로부터 약 300 m, 남쪽에서는 약 600 m 의 두께로 분포하고; 2) 이암층 내에 수십 ohm-m의 전기비저항을 보이는 화산력응회암 및 조면현무암이 교대로 나타나며; 3) 수백 ohm-m의 전기비저항을 갖는 유문암이 약 400 m 의 두께로; 4) 이후 약 1.5 km 까지는 약 100 ohm-m 의 전기비저항을 보이는 사암 및 이암층이 분포하며; 5) 약 3 km 심도에서 저비저항 구조가 나타나는데 이 층에 대해서는 추가적인 지질학적, 지구물리학적인 조사가 필요할 것으로 생각된다.

이중 구조의 X선 차폐시트 설계를 위한 FLUKA 수송코드의 신뢰성 검증 (Reliability Verification of FLUKA Transport Code for Double Layered X-ray Protective Sheet Design)

  • 강상식;허승욱;최일홍;전제훈;양승우;김교태;허예지;박지군
    • 한국방사선학회논문지
    • /
    • 제11권7호
    • /
    • pp.547-553
    • /
    • 2017
  • 현재 의료분야에서는 방사선 차폐체로서 납(Pb)이 널리 쓰이고 있다. 하지만 납은 무게가 매우 무거워 납치마 등의 방호복은 장시간 착용이 어려우며, 인체에 치명적인 납 중독의 위험이 상시 가지고 있다는 문제점을 가지고 있다. 이러한 문제점을 해결하고자 납을 대체 할 수 있는 물질에 대한 많은 연구가 진행되고 있다. 현재 납의 대체물질로써 대표적인 바륨(Ba)과 요오드(I) 등은 우수한 차폐능을 가지고 있지만, 30keV 근처의 에너지 영역에서 특성 X선을 방출하는 특성을 가지고 있다. 환자나 방사선 종사자의 경우 차폐체를 인체에 접촉하고 있는 경우가 많으므로 차폐체에서 발생되는 특성 X선이 인체에 직접 조사되어 방사선 피폭을 증가시킬 위험이 매우 높다. 본 연구에서는 바륨(Ba)과 요오드(I)등에서 발생되는 특성 X선을 제거하기에 적절한 이중구조 차폐체를 방사선 수송코드 중 하나인 FLUKA 수송코드를 개발하여 선행연구로서 진행된 MCNPX 시뮬레이션과 비교 분석하여 이중구조 차폐체의 차폐율에 대한 신뢰성을 검증하고자 하였다. MCNPX와 FLUKA를 이용하여 황산바륨($BaSO_4$)과 산화비스무스($Bi_2O_3$)로 이루어진 다양한 두께조합의 이중구조 차폐체를 설계하였으며, IEC61331-1에 제시된 모식도를 기하학적으로 동일하게 시뮬레이션 상에 구현하였다. 또한, 120 kVp의 연속 X선 스펙트럼에 대한 차폐체의 투과스펙트럼과 흡수선량을 납과 비교 평가하였다. 평가결과, $0.3mm-BaSO_4/0.3mm-Bi_2O_3$$0.1mm-BaSO_4/0.5mm-Bi_2O_3$ 구조에서는 33 keV와 37 keV의 특성 X선을 모두 흡수하였으며, 90 keV 이상의 고에너지 X선에 대해서도 납과 거의 유사한 차폐효율을 보였다. 또한, FLUKA의 수송코드는 33 keV 이하에서는 cut-off 가 발생하여 저에너지 X선 광자에 대한 전산모사에 제약이 있지만, 40 keV 이상의 고에너지 영역에서 MCNPX와의 상대오차가 6 % 이내로 신뢰성이 매우 우수하다는 것을 확인할 수 있었다.