• Title/Summary/Keyword: Layer transfer

Search Result 1,530, Processing Time 0.027 seconds

A Wireless Sensor Network Architecture and Security Protocol for Monitoring the State of Bridge (교량감시를 위한 무선 센서 네트워크 구조 및 보안 프로토콜)

  • Lim Hwa-Jung;Jeon Jin-Soon;Lee Heon-Guil
    • Journal of the Korea Computer Industry Society
    • /
    • v.6 no.3
    • /
    • pp.465-476
    • /
    • 2005
  • The wireless sensor network consists of a number of sensor nodes which have physical constraints. Each sensor node senses surrounding environments and sends the sensed information to Sink. In order to alleviate the inherent vulnerability in security of the wireless sensor nodes with the hardware constraints, the lightweight security protocol is needed and a variety of research is ongoing. In this paper, we propose a non-hierarchical sensor network and a security protocol that is suitable for monitoring man-made objects such as bridges. This paper, furthermore, explores a two-layer authentication, key distribution scheme which distributes the key and location of a sensor node in advance, and an effective security routing protocol which can take advantage of the Sleep and Awake state. This also results in the increased data transfer rate by increasing the number of alternative routing paths and the reduced energy consumption rate.

  • PDF

Complete genome sequence of Betaproteobacteria strain GR16-43 isolated form a freshwater pond in South Korea (담수에서 분리한 Betaproteobacteria GR16-43의 유전체 염기서열 분석)

  • Choi, Ahyoung;Baek, Kiwoon;Chung, Eu Jin;Kim, Jee-Hwan;Choi, Gang-Guk
    • Korean Journal of Microbiology
    • /
    • v.53 no.4
    • /
    • pp.320-322
    • /
    • 2017
  • A betaproteobacterium strain GR16-43 was isolated from a surface layer of the Geomnyong Pond in Republic of Korea by a dilution-to-extinction culturing method. We report the whole genome sequence of the strain GR16-43, which contains 4,806,848 bp with a G + C content 67.12%, and to include 4,424 protein-coding genes and 47 transfer RNA genes. The genome was determined to contain the genes encoding carbon monoxide dehydrogenase, nitrate reductase, nitrite reductase, nitric oxide reductase, and the sulfur oxidation (sox) gene cluster, highlighting the potential importance of the bacterial group represented by the strain in the cycling of inorganic elements. These results indicate that strain GR16-43 genome showed several traits indicating adaptation of the bacteria to living in freshwater environments.

Study of Corrosion of Brass Coated Steel Cords in the Acetonitrile Solution of Sulfenamide Derivatives by Tafel Plot and AC Impedance Measurements

  • Young Chun Ko;Byung Ho Park;Hae Jin Kim;Q Won Choi;Jongbaik Ree;Keun Ho Chung
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.2
    • /
    • pp.122-126
    • /
    • 1994
  • Corrosion of brass coated steel cords in the acetonitrile solution of sulfenamide derivatives, N-Cyclohexylbenzothiazole-2-sulfenamide (CBTS), N,N'-Dicyclohexylbenzothiazole-2-sulfenamide (DCBS), N-tert-Butylbenzothiazole-2-sulfenamide (TBBS), N-tert-Amylbenzothiazole-2-sulfenamide (TABS), and N-Oxydiethylbenzothiazole-2-sulfenamide (OBTS) was investigated by potentiostatic anodic and cathodic polarization (Tafel plot), DC polarization resistance, and AC impedance measurements. The corrosion current densities and rates are 1.236 ${\mu}A /cm^2$ and 0.655 MPY for CBTS; 1.881 ${\mu}A/cm^2$ and 0.988 MPY for DCBS; 2.367 ${\mu}A/cm^2$ and 1.257 MPY for TBBS; 3.398 ${\mu}A /cm^2$ and 1.809 MPY for TABS, respectively. OBTS among derivatives under study shows the lowest corrosion density (0.546 ${\mu}A /cm^2$) and the slowest corrosion rate (0.288 MPY). Also, the charge transfer resistances and the double layer capacitances are 275.21 $k{\Omega}{\cdot}cm^2$ and 7.0 ${\mu}F{cdot}cm^{-2}$ for CBTS; 14.24 ${\mu}F{\cdot}cm^2$ and 26 ${\mu}F{\cdot}cm^{-2}$ for DCBS; 54.15 $k{\Omega}{\cdot}cm^2$ and 26 ${\mu}F{\cdot}cm^{-2}$ for TBBS; 0.96$k{\Omega}{\cdot}cm^2$ and 83 ${\mu}F{\cdot}cm^{-2}$ for TABS, respectively. The weaker the electron donating inductive effect of derivatives is and the smaller the effect of steric hindrance is, the more the corrosion of brass coated steel cords in the acetonitrile solution of sulfenamide derivatives is prevented. The above results agree with that observed in the field of tire industry.

Development of a Hierarchical HydroG-OneFlow Web Services of River GeoSpatial Information (하천공간정보의 계층적 HydroG-OneFlow 웹서비스 개발)

  • Shin, Hyung Jin;Hwang, Eui Ho;Chae, Hyo Sok;Hong, Sung Soo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.626-626
    • /
    • 2015
  • 본 연구에서는 하천공간정보의 웹서비스를 위해 SOAP(Simple Object Access Protocol) API 및 REST(Representation State Transfer) API로 제공하는 HydroG-OneFlow 웹서비스를 개발하였다. HydroG-OneFlow는 GML 기반의 서비스를 제공하며 GetBasin, GetGeoVariable 및 GetData 등의 기본서비스로 구성된다. GML은 GIS S/W의 벡터 GML 포맷과 공간정보 오픈플랫폼 서비스인 브이월드 데이터 API에서 제공하는 GML 포맷을 참고하여 하천공간 벡터정보를 제공할 수 있도록 GML을 구성하였다. GDM 공간 데이터에 대한 벡터정보 ML 수용 수준을 향상시킬 수 있도록 벡터구조의 점, 선, 면 정보에 대하여 GML의 PointPropertyType, CurvePropertyType, SurfacePropertyType을 도입하였다. 또한 일반적인 공간자료에서는 Multi 객체에 대한 지원도 필요하다. 현 GDM 데이터베이스에서도 OGC 표준의 MultiPoint, MultiLineString, MultiPolygon을 지원하고 있다. 이를 위하여 GML의 상응 요소인MultiPointPropertyType, MultiCurvePropertyType, MultiSurfacePropertyType을 하천공간정보 벡터 스키마에 도입하여 활용하였다. 클라이언트 서버 통신은 메시지 교환프로토콜인 SOAP을 사용하여 서버의 객체를 직접 호출하여 이루어진다. 서버는 서버의 제공 서비스를 WSDL(Web Service Description Language)를 통하여 게시하고 클라이언트는 이 기준(Criteria)을 참고하여 접근한다. GetData의 경우 Type(GRID or VECTOR), GDM(Geospatial Data Model) 여부(true or false), LayerName, BasinID, GenTime을 인자로 받아 GeoData에서 검색된 정보를 반환한다. SOAP버전은 1.1과 1.2를 지원하여 접근하는 클라이언트에서 선택할 수 있도록 개발하였다.

  • PDF

Characteristic Study on Effect of the Vent Mixer to Supersonic Fuel-Air Mixing with Stereoscopic-PIV Method (3차원 PIV 기법을 사용한 벤트혼합기가 초음속 연료-공기 혼합에 미치는 특성 연구)

  • Kim, Chae-Hyoung;Jeung, In-Seuck;Choi, Byung-Il;Kouchi, Toshinori;Masuya, Goro
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.4
    • /
    • pp.50-56
    • /
    • 2012
  • Vent mixer can provide main flow directly into a recirculation region downstream of the mixer to enhance fuel-air mixing efficiency. Based on experimental results of three-dimensional velocity, vorticity and turbulent kinetic energy obtained by a stereoscopic PIV method, the performance of the vent mixer was compared with that of the step mixer which was used as a basic model. Thick shear layers of the vent mixer induced the increase of the penetration height. The turbulent kinetic energy mainly distributed along a boundary layer between the main flow and the jet plume. This turbulent field activates mass transfer in a mixing region, leading to the mixing enhancement.

Analysis of Resonant Characteristics in High Voltage Windings of Main Transformer for Railway Vehicle using EMTP (EMTP를 이용한 철도차량용 주변압기 고압권선의 공진특성 분석)

  • Jeong, Ki-Seok;Jang, Dong-Uk;Chung, Jong-Duk
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.4
    • /
    • pp.436-444
    • /
    • 2016
  • The primary windings of the main transformer for rolling stock have several natural frequencies that can occur internal resonance with transient voltages induced on a high voltage feeding line. Factory testing is limited in its ability to determine whether or not transient voltage with various shape and duration can be excitable. This study presents the design of a high voltage windings model and simulation and analysis of the internal resonant characteristics in terms of the initial voltage distribution and voltage-frequency relationship using the electromagnetic transients program (EMTP). Turn-based lumped-parameters are calculated using the geometry data of the transformer. And, sub-models, being grouped into the total number of layers, are composed using a ladder-network model and implemented by the library function of EMTP. Case studies are used to show the layer-based voltage-frequency relationship characteristics according to the frequency sweep and the voltage escalation and distribution aspects in time-domain simulation.

A Study on the Chilling Start-up Characteristics and Performance of a Gas Loaded Heat Pipe (가스내장 히트파이프의 냉시동특성과 성능에 관한 연구)

  • Hong, Sung-Eun;Kang, Hwan-Kook
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.11
    • /
    • pp.915-922
    • /
    • 2006
  • Considering heat pipe design principles in fabrication and operational performances, water is one of the most recommended working fluids to make mid to low tempera lure heat pipes. But the conventional water heat pipes might encounter the failure in a cold start-up operation when socked at a chilling temperature lower than the freezing point. If they are subjected to a heat supply for start-up at a temperature around $-20^{\circ}C$, the rate of the vapor flow and the corresponding heat transfer from the evaporator to the condenser is so small that the vapor keeps to stick on the surface of the chilling condenser wall, forming an ice layer, resulting in a liquid deficiency in the evaporator. This kind of problems was resolved by Kang et al. in 2004 by adopting a gas loading heat pipe technology to the conventional water heat pipes. This study was conducted to examine a chilling start-up procedure of gas loading heat pipes by investigating the behaviors of heat pipe wall temperatures. And the thermal resistance of the gas loaded heat pipe that depends on the operating temperatures and heat loads was measured and examined. Two water heat pipes were designed and fabricated for the comparison of performances, one conventional and the other loaded with $N_2$ gas. They were put on start-up test at a heat supply of 30 W after having been socked at an initial temperature around $-20^{\circ}C$. It was observed that the gas loaded one had succeeded in chilling start-up operation.

MULTI-SCALE MODELING AND ANALYSIS OF CONVECTIVE BOILING: TOWARDS THE PREDICTION OF CHF IN ROD BUNDLES

  • Niceno, B.;Sato, Y.;Badillo, A.;Andreani, M.
    • Nuclear Engineering and Technology
    • /
    • v.42 no.6
    • /
    • pp.620-635
    • /
    • 2010
  • In this paper we describe current activities on the project Multi-Scale Modeling and Analysis of convective boiling (MSMA), conducted jointly by the Paul Scherrer Institute (PSI) and the Swiss Nuclear Utilities (Swissnuclear). The long-term aim of the MSMA project is to formulate improved closure laws for Computational Fluid Dynamics (CFD) simulations for prediction of convective boiling and eventually of the Critical Heat Flux (CHF). As boiling is controlled by the competition of numerous phenomena at various length and time scales, a multi-scale approach is employed to tackle the problem at different scales. In the MSMA project, the scales on which we focus range from the CFD scale (macro-scale), bubble size scale (meso-scale), liquid micro-layer and triple interline scale (micro-scale), and molecular scale (nano-scale). The current focus of the project is on micro- and meso-scales modeling. The numerical framework comprises a highly efficient, parallel DNS solver, the PSI-BOIL code. The code has incorporated an Immersed Boundary Method (IBM) to tackle complex geometries. For simulation of meso-scales (bubbles), we use the Constrained Interpolation Profile method: Conservative Semi-Lagrangian $2^{nd}$ order (CIP-CSL2). The phase change is described either by applying conventional jump conditions at the interface, or by using the Phase Field (PF) approach. In this work, we present selected results for flows in complex geometry using the IBM, selected bubbly flow simulations using the CIP-CSL2 method and results for phase change using the PF approach. In the subsequent stage of the project, the importance of effects of nano-scale processes on the global boiling heat transfer will be evaluated. To validate the models, more experimental information will be needed in the future, so it is expected that the MSMA project will become the seed for a long-term, combined theoretical and experimental program.

Emitter Electrode Design to Optimize the Optical and Electrical Characteristics of Planar Solar Cells (평판형 태양 전지의 광학 및 전기적 특성 최적화를 위한 에미터 전극 설계 연구)

  • Lee, Sangbok;Do, Yun Seon
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.1
    • /
    • pp.37-44
    • /
    • 2020
  • In this study, we propose a design method to optimize the electro-optical efficiency of a planar solar cell structure by adjusting one-dimensionally periodic emitter electrodes. Since the aperture ratio of the active layer decreases as the period of the emitter electrode decreases, the amount of light absorption diminishes, affecting the performance of the device. Here we design the optimal structure of the periodic emitter electrode in a simple planar solar cell, by simulation. In terms of optics, we find the condition that shows optical performance similar to that of a reference without the emitter electrode. In addition, the optimized electrode structure is extracted considering both the optical and electrical efficiency. This work will help to increase the utilization of solar cells by suggesting a structure that can most efficiently transfer charge generated by photoelectric conversion to the electrodes.

Heterogeneous Network Gateway Architecture and Simulation for Tactical MANET (전술 에드혹 환경에서 이종망 게이트웨이 구조 및 시뮬레이션 연구)

  • Roh, Bong Soo;Han, Myoung Hun;Kwon, Dae Hoon;Ham, Jae Hyun;Yun, Seon Hui;Ha, Jae Kyoung;Kim, Ki Il
    • Journal of the Korea Society for Simulation
    • /
    • v.28 no.2
    • /
    • pp.97-105
    • /
    • 2019
  • The tactical mobile ad-hoc network(MANET) consists of distributed autonomous networks between individual ground nodes, which is effective in terms of network survivability and flexibility. However, due to constraints such as limited power, terrain, and mobility, frequent link disconnection and shadow area may occur in communication. On the other hand, the satellite network has the advantage of providing a wide-area wireless link overcoming terrain and mobility, but has limited bandwidth and high-latency characteristic. In the future battlefield, an integrated network architecture for interworking multi-layer networks through a heterogeneous network gateway (HNG) is required to overcome the limitations of the existing individual networks and increase reliability and efficiency of communication. In this paper, we propose a new HNG architecture and detailed algorithm that integrates satellite network and the tactical MANET and enables reliable data transfer based on flow characteristics of traffic. The simulations validated the proposed architecture using Riverbed Modeler, a network-level simulator.