• Title/Summary/Keyword: Lateral-flow immunoassay

Search Result 25, Processing Time 0.041 seconds

Development of a Rapid Automated Fluorescent Lateral Flow Immunoassay to Detect Hepatitis B Surface Antigen (HBsAg), Antibody to HBsAg, and Antibody to Hepatitis C

  • Ryu, Ji Hyeong;Kwon, Minsuk;Moon, Joung-Dae;Hwang, Min-Woong;Lee, Jeong-Min;Park, Ki-Hyun;Yun, So Jeong;Bae, Hyun Jin;Choi, Aeran;Lee, Hyeyoung;Jung, Bongsu;Jeong, Juhee;Han, Kyungja;Kim, Yonggoo;Oh, Eun-Jee
    • Annals of Laboratory Medicine
    • /
    • v.38 no.6
    • /
    • pp.578-584
    • /
    • 2018
  • Background: Accurate, rapid, and cost-effective screening tests for hepatitis B virus (HBV) and hepatitis C virus (HCV) infection may be useful in laboratories that cannot afford automated chemiluminescent immunoassays (CLIAs). We evaluated the diagnostic performance of a novel rapid automated fluorescent lateral flow immunoassay (LFIA). Methods: A fluorescent LFIA using a small bench-top fluorescence reader, Automated Fluorescent Immunoassay System (AFIAS; Boditech Med Inc., Chuncheon, Korea), was developed for qualitative detection of hepatitis B surface antigen (HBsAg), antibody to HBsAg (anti-HBs), and antibody to HCV (anti-HCV) within 20 minutes. We compared the diagnostic performance of AFIAS with that of automated CLIAs-Elecsys (Roche Diagnostics GmbH, Penzberg, Germany) and ARCHITECT (Abbott Laboratories, Abbott Park, IL, USA)-using 20 seroconversion panels and 3,500 clinical serum samples. Results: Evaluation with the seroconversion panels demonstrated that AFIAS had adequate sensitivity for HBsAg and anti-HCV detection. From the clinical samples, AFIAS sensitivity and specificity were 99.8% and 99.3% for the HBsAg test, 100.0% and 100.0% for the anti-HBs test, and 98.8% and 99.1% for the anti-HCV test, respectively. Its agreement rates with the Elecsys HBsAg, anti-HBs, and anti-HCV detection assays were 99.4%, 100.0%, and 99.0%, respectively. AFIAS detected all samples with HBsAg genotypes A-F and H and anti-HCV genotypes 1, 1a, 1b, 2a, 2b, 4, and 6. Cross-reactivity with other infections was not observed. Conclusions: The AFIAS HBsAg, anti-HBs, and anti-HCV tests demonstrated diagnostic performance equivalent to current automated CLIAs. AFIAS could be used for a large-scale HBV or HCV screening in low-resource laboratories or low-to middle-income areas.

Application of Rapid and Reliable Detection of Cymbidium Mosaic Virus by Reverse Transcription Recombinase Polymerase Amplification Combined with Lateral Flow Immunoassay

  • Do-Hyun, Kim;Rae-Dong, Jeong;Sena, Choi;Ho-Jong, Ju;Ju-Yeon, Yoon
    • The Plant Pathology Journal
    • /
    • v.38 no.6
    • /
    • pp.665-672
    • /
    • 2022
  • Cymbidium mosaic virus (CymMV) is one of economically important viruses that cause significant losses of orchids in the world. In the present study, a reverse transcription recombinase polymerase amplification (RT-RPA) assay combined with a lateral flow immunostrip (LFI) assay was developed for the detection of CymMV in orchid plants. A pair of primers containing fluorescent probes at each terminus that amplifies highly specifically a part of the coat protein gene of CymMV was determined for RT-RPA assay. The RT-RPA assay involved incubation at an isothermal temperature (39℃) and could be performed rapidly within 30 min. In addition, no cross-reactivity was observed to occur with odontoglossum ringspot virus and cymbidium chlorotic mosaic virus. The RT-RPA with LFI assay (RT-RPA-LFI) for CymMV showed 100 times more sensitivity than conventional reverse transcription polymerase chain reaction (RT-PCR). Furthermore, the RT-PCR-LFI assay demonstrated the simplicity and the rapidity of CymMV detection since the assay did not require any equipment, by comparing results with those of conventional RT-PCR. On-site application of the RT-RPA-LFI assay was validated for the detection of CymMV in field-collected orchids, indicating a simple, rapid, sensitive, and reliable method for detecting CymMV in orchids.

Development of Nucleic Acid Lateral Flow Immunoassay for Rapid and Accurate Detection of Chikungunya Virus in Indonesia

  • Ajie, Mandala;Pascapurnama, Dyshelly Nurkartika;Prodjosoewojo, Susantina;Kusumawardani, Shinta;Djauhari, Hofiya;Handali, Sukwan;Alisjahbana, Bachti;Chaidir, Lidya
    • Journal of Microbiology and Biotechnology
    • /
    • v.31 no.12
    • /
    • pp.1716-1721
    • /
    • 2021
  • Chikungunya fever is an arboviral disease caused by the Chikungunya virus (CHIKV). The disease has similar clinical manifestations with other acute febrile illnesses which complicates differential diagnosis in low-resource settings. We aimed to develop a rapid test for CHIKV detection based on the nucleic acid lateral flow immunoassay technology. The system consists of a primer set that recognizes the E1 region of the CHIKV genome and test strips in an enclosed cassette which are used to detect amplicons labeled with FITC/biotin. Amplification of the viral genome was done using open-source PCR, a low-cost open-source thermal cycler. Assay performance was evaluated using a panel of RNA isolated from patients' blood with confirmed CHIKV (n = 8) and dengue virus (n = 20) infection. The open-source PCR-NALFIA platform had a limit of detection of 10 RNA copies/ml. The assay had a sensitivity and specificity of 100% (95% CI: 67.56% - 100%) and 100% (95% CI: 83.89% - 100%), respectively, compared to reference standards of any positive virus culture on C6/36 cell lines and/or qRT-PCR. Further evaluation of its performance using a larger sample size may provide important data to extend its usefulness, especially its utilization in the peripheral healthcare facilities with scarce resources and outbreak situations.

Development of Disposable Enzyme-linked Immunosensor Strip Platform (일회용 스트립형 효소면역센서용 플랫폼의 개발)

  • Choi, Ji-Hye;Yi, Seung-Jae;Chang, Seung-Cheol;Kim, Kyung-Chun
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.400-405
    • /
    • 2011
  • This study introduced the development of a strip type disposable enzyme-linked immunosensor platform for the detection of IgG. Strips of the strip sensor were fabricated by using commercial nitrocellulose filter membranes and a housing holder for the strips was manufactured by using a standard injection molding process for a plastic material. An IgG-urease conjugate was prepared and used for the competitive immune-binding with sample IgG. From the enzymatic reaction between the conjugated urease and urea added, ammonia was generated and caused a localized alkaline pH change on the immobilized antibody band which was coated onto the sensor strips. This pH increase subsequently caused a color change of the antibody band in the presence of a pH indicator, phenol red. Used in conjunction with a competitive immunoassay format, the intensity of the color produced is directly linked with the concentration of target analyte, IgG, and specific measurement of IgG in a lateral flow immunoassay format was achieved over the range 100 ppb to 2000 ppb IgG.

Evaluation of a rapid diagnostic kit "BIOLINE RSVTM" for the detection of respiratory syncytial virus (Respiratory Syncytial Virus 감염의 조기 진단 kit "바이오라인 알에스브이TM"의 평가)

  • Kim, So-Hee;Sung, Ji-Yeon;Yang, Mi-Ae;Eun, Byung-Wook;Lee, Jin-A;Choi, Eun-Hwa;Lee, Hoan-Jong
    • Pediatric Infection and Vaccine
    • /
    • v.14 no.1
    • /
    • pp.91-96
    • /
    • 2007
  • Purpose : This study was performed to evaluate a new rapid diagnostic kit (BIOLINE $RSV^{TM}$; Standard Diagnostics Inc., Yongin, Korea), a lateral-flow immunoassay, in the detection of respiratory syncytial virus (RSV) from the nasopharyngeal aspirates (NPA) of children with lower respiratory tract infections (LRTIs) in comparison with other diagnostic methods. Methods : Three hundred and nineteen NPAs were selected from a large pool of NPAs that had been obtained from children with LRTIs. All specimens had already been tested for RSV by culture and immunofluorescent (IF) test, and had been kept frozen. Tests with BIOLINE $RSV^{TM}$ were performed at least twice. All who conducted the experiments or interpreted the test results were blinded to the results of both culture and IF tests. Results : One hundred seven (97.3%) of 110 specimens that were positive for RSV by both culture and IF test, 29 (87.9%) of 33 that were positive by IF test only, 20 (76.9%) of 26 that were positive by culture only, and 140 (93.3%) of 150 that were negative by both methods were negative for RSV by BIOLINE $RSV^{TM}$. By combining the above results, the following 5 diagnostic values of BIOLINE $RSV^{TM}$ were determined in comparison with viral culture or IF test; sensitivity, 92.3% (156/169, 95% confidence interval [CI], 87.1-97.5%); specificity, 93.3% (140/150, 95% CI, 88.4-98.2%); positive predictive value, 94.0% (156/166, 95% CI, 89.5-98.5%); negative predictive value, 91.5% (140/143, 95% CI, 86.0-97.0%); and agreement, 95.9% (306/319, 95% CI, 92.1-99.7%), respectively. Conclusion : This study revealed that BIOLINE $RSV^{TM}$ demonstrated good sensitivity and specificity for the detection of RSV antigen from NPAs of children with LRTIs. Because of simple methods and quick results, this test may be useful for the diagnosis of RSV infection during the epidemic periods.

  • PDF

Clinical Laboratory Aspect of Carbapenem-Resistant Enterobacteriaceae (카바페넴내성장내세균속균종의 임상검사 측면)

  • Park, Chang-Eun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.1
    • /
    • pp.18-27
    • /
    • 2020
  • The correct distinction of carbapenem-resistant Enterobacteriaceae (CRE) and ccarbapenemase producing Enterobacteriaceae (CPE) and the rapid detection of CPE are important for instituting the correct treatment and management of clinical infections. Screening protocols are mainly based on cultures of rectal swab specimens on selective media followed by phenotypic tests to confirm a carbapenem-hydrolyzing activity, the rapid carbapenem inactivation method, lateral flow immunoassay, the matrix-assisted laser desorption ionization-time-of-flight test and molecular methods. The CPE is accurate for detection, and is essential for the clinical treatment and prevention of infections. A variety of phenotypic methods and gene-based methods are available for the rapid detection of carbapenemases, and these are expected to be routinely used in clinical microbiology laboratories. Therefore, to control the spread of carbapenemase, many laboratories around the world will need to use reliable, fast, high efficiency, simple and low cost methods. Optimal effects in patient applications would require rapid testing of CRE to provide reproducible support for antimicrobial management interventions or the treatment by various types of clinicians. For the optimal test method, it is necessary to combine complementary test methods to discriminate between various resistant bacterial species and to discover the genetic diversity of various types of carbapenemase for arriving at the best infection control strategy.

Development of Lateral Flow Immunofluorescence Assay Applicable to Lung Cancer (폐암 진단에 적용 가능한 측면 유동 면역 형광 분석법 개발)

  • Supianto, Mulya;Lim, Jungmin;Lee, Hye Jin
    • Applied Chemistry for Engineering
    • /
    • v.33 no.2
    • /
    • pp.173-178
    • /
    • 2022
  • A lateral flow immunoassay (LFIA) method using carbon nanodot@silica as a signaling material was developed for analyzing the concentration of retinol-binding protein 4 (RBP4), one of the lung cancer biomarkers. Instead of antibodies mainly used as bioreceptors in nitrocellulose membranes in LFIA for protein detection, aptamers that are more economical, easy to store for a long time, and have strong affinities toward specific target proteins were used. A 5' terminal of biotin-modified aptamer specific to RBP4 was first reacted with neutravidin followed by spraying the mixture on the membrane in order to immobilize the aptamer in a porous membrane by the strong binding affinity between biotin and neutravidin. Carbon nanodot@silica nanoparticles with blue fluorescent signal covalently conjugated to the RBP4 antibody, and RBP4 were injected in a lateral flow manner on to the surface bound aptamer to form a sandwich complex. Surfactant concentrations, ionic strength, and additional blocking reagents were added to the running buffer solution to optimize the fluorescent signal off from the sandwich complex which was correlated to the concentration of RBP4. A 10 mM Tris (pH 7.4) running buffer containing 150 mM NaCl and 0.05% Tween-20 with 0.6 M ethanolamine as a blocking agent showed the optimum assay condition for carbon nanodot@silica-based LFIA. The results indicate that an aptamer, more economical and easier to store for a long time can be used as an alternative immobilizing probe for antibody in a LFIA device which can be used as a point-of-care diagnosis kit for lung cancer diseases.

Clinical evaluation of a rapid diagnostic test kit for detection of canine coronavirus

  • Yoon, Seung-Jae;Seo, Kyoung-Won;Song, Kun-Ho
    • Korean Journal of Veterinary Research
    • /
    • v.58 no.1
    • /
    • pp.27-31
    • /
    • 2018
  • Canine coronavirus is a single-stranded RNA virus that causes enteritis in dogs of any age. Coronaviral enteritis is seldom definitively diagnosed, since it is usually much less severe than many other types of enteritis and is self-limiting. Conventional diagnostics for the canine coronaviral enteritis such as polymerase chain reaction (PCR), virus isolation, and electron microscopic examination are inappropriate for small animal clinics due to the complicated experimental processes involved. Therefore, a commercially available lateral flow test kit based on chromatographic immunoassay techniques was tested to evaluate its performance as a first-line diagnostic test kit that could be used in clinics. The coronavirus antigen test kit detected canine coronavirus-infected dogs with 93.1% sensitivity and 97.5% specificity. The detection limit of the test kit was between $1.97{\times}10^4/mL$ and $9.85{\times}10^3/mL$ for samples with a 2-fold serial dilution from $1.25{\times}10^6\;TCID_{50}$ ($TCID_{50}$, 50% tissue culture infectious dose). Additionally, the test kit had no cross-reactivity with canine parvovirus, distemper virus, or Escherichia coli. Overall, the commercially available test kit showed good diagnostic performance in a clinical setting, with results similar to those from PCR, confirming their potential for convenient and accurate use in small animal clinics.

Recent Advancements in Technologies to Detect Enterohaemorrhagic Escherichia coli Shiga Toxins

  • Jeongtae Kim;Jun Bong Lee;Jaewon Park;Chiwan Koo;Moo-Seung Lee
    • Journal of Microbiology and Biotechnology
    • /
    • v.33 no.5
    • /
    • pp.559-573
    • /
    • 2023
  • Shiga toxin (Stxs)-producing enterohaemorrhagic Escherichia coli (EHEC) and Shigella dysenteriae serotype 1 are major causative agents of severe bloody diarrhea (known as hemorrhagic colitis) and hemolytic uremic syndrome (HUS) associated with extraintestinal complications such as acute renal failure and neurologic impairment in infected patients under 9 years of age. Extreme nephrotoxicity of Stxs in HUS patients is associated with severe outcomes, highlighting the need to develop technologies to detect low levels of the toxin in environmental or food samples. Currently, the conventional polymerase chain reaction (PCR) or immunoassay is the most broadly used assay to detect the toxin. However, these assays are laborious, time-consuming, and costly. More recently, numerous studies have described novel, highly sensitive, and portable methods for detecting Stxs from EHEC. To contextualize newly emerging Stxs detection methods, we briefly explain the basic principles of these methods, including lateral flow assays, optical detection, and electrical detection. We subsequently describe existing and newly emerging rapid detection technologies to identify and measure Stxs.