• Title/Summary/Keyword: Lateral earth pressure

Search Result 211, Processing Time 0.038 seconds

Behavior Analysis of Earth Retaining Walls on the Excavation for Contact Structure (인접 구조물의 터파기로 인한 흙막이 벽체의 거동 분석)

  • Kim, Young-Muk;Jung, Young-Soo;Hong, Chang-Pyo;Shin, Youn-Sub
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1496-1503
    • /
    • 2005
  • The study on the lateral earth pressure is briskly preformed for various conditions such as type of retaining walls, ground condition, and type of supporting systems. It is not simple to determine the distribution of lateral earth pressure accurately, however, because the lateral earth pressure is affected by various factors. This study is performed to analyze the behavior of earth retaining walls for new excavation contacting with existing excavation by comparing with the site measuring values before and after new excavation. On the base of observation, the distribution of strut axial forces is similar to that of ganeral earth retaining walls, but strut axial forces is increased by removal of existing earth anchors. When new excavation is performed contacting with existing excavation, the axial force of strut is decreased because of soil exclusion in the behind walls, but that force is increased after new exeavation. The analysis result show that the installation of strut in middle part makes a effect to not only 1 adjacent strut, but 3-5 adjacent struts. Also during new excavation strut axial forces is decreased by relaxation of total earth retaining wall system.

  • PDF

Effects of Relief Shelves on Stability of Retaining Walls

  • Ahn, Taebong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.23 no.9
    • /
    • pp.25-31
    • /
    • 2022
  • Attaching shelf to retaining structure leads to a decrease in the total lateral earth pressure. This decrease enables the retaining structures to become more stable, to have small displacement, and to exhibit lower bending moments, the relief shelves effects are analyzed using FEM in order to understand how they stabilize cantilever wall in this study. Several models are varied by changing location and width of shelves to realize earth pressure and displacements of retaining wall. The displacement is getting smaller because earth pressure acting on shelf increases as shelves locations are lower and width is longer. The ground settlement variation effects caused by relief shelves are studied also. The ground settlement increases abruptly where shelf location is between of 0.5H and 0.625H, and settlement decreases suddenly where shelf width is between b/h=0.375 and b/h=0.500. The shelf significantly reduces earth pressure and movement of the wall. This decrease in the lateral pressure increases the retaining structure stability.

Lateral Earth Pressure Caused by Action on Earth Retaining Wall in Clay Foundation Ground with Consideration of Construction Speed (지중 구조물에 작용하는 측방토압에 대한 성토 재하 속도의 영향)

  • Im Eun-Sang;Lee Kang-Il
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.7
    • /
    • pp.57-68
    • /
    • 2004
  • When an embankment is constructed on soft clay ground, the lateral displacement generally called as lateral flow is generated in the foundation ground. It strongly affects stabilities of structures, such as foundation piles and underground pipes, in and on the foundation ground. The lateral earth pressure induced by the lateral flow is influenced by the magnitude and construction speed of embankment, the geometric conditions and geotechnical characteristics of the embankment, and the foundation ground, and so on. Accurate methods for estimating the lateral earth pressure have not ever been established because the lateral flow of a foundation ground shows very complicated behavior, which is caused by the interaction of shear deformation and volumetric deformation. In this paper, a series of model tests were carried out in order to clarify effects of construction speed of an embankment on the lateral earth pressure in a foundation ground were design. It was found that the magnitude and the distribution of the lateral earth pressure and its change with time are dependent on the construction speed of the embankment. It was found that a mechanism for the lateral earth pressure was generated by excess pore water pressure due to negative dilatancy induced by shear deformation under the different conditions of construction speeds of embankments.

An Basic Study on the Lateral Pressure to the Form for Rammed Earth Method (흙다짐공법에서 거푸집측압에 대한 기초적연구)

  • Lee, Jung Je;Kwak, Yoon Keun;Hwang, Hey Zoo;Lee, Jong Kook
    • KIEAE Journal
    • /
    • v.9 no.1
    • /
    • pp.39-45
    • /
    • 2009
  • The lateral pressure that functions on the form of the rammed earth method occupies an important part in the construction of the form. The following research constructed testing forms of $800mm{\times}1200mm$, that have the wall thickness of 200mm, 300mm, 400mm and 500mm to measure the lateral pressures according to the wall thicknesses. Research showed that compared to the concrete construction lateral pressures, the form results measured 2.3-8.9 times higher, and rather than thickness of the form, the distance between the rammer and mold and assuring time had direct relation to the lateral pressure of the form.

Lateral Earth Pressure with The Shape of Narrow Space with Backfill (좁은 공간의 형상에 따른 되메움 토압에 관한 연구)

  • Huh, Kyung-Han
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.1
    • /
    • pp.89-96
    • /
    • 2008
  • The study, with regard to unsymmetrically inclined backfilled wall, was intended to estimate the lateral earth pressure, develop the equation for lateral earth pressure and eventually identify the mutual behavior, based on the modified Kellogg theory, while changing the width between the walls, wall angle, relative density and wall friction angle. To verify the geostatic pressure obtained from the study, the results in the wake of 62 kinds of model tests performed were compared and evaluated with the behaviors based on theoretical equations. As a result, the wall inclination angle was found to be the factors affecting the earth pressure the most, when both walls were inclined unsymmetrically. And the narrower the backfill space and the larger the wall inclination angle to the horizontal level, the greater the effect of the wall friction. The equation considering the wall friction reaction indicated the value, which was closer to the actually-measured earth pressure, and when the width between the warts was narrow, the arching effect appeared to be great, thereby indicating the difference between the measured earth pressure, theoretically calculated earth pressure and the geostatic pressure proved to be insignificant.

A Study on the Application of Lateral Earth Pressure to Earth Retaining Wall Considering Ground Characteristics in Jeju I - Case of Strut Construction - (제주 지역의 지반 특성을 고려한 흙막이벽의 측방토압 적용에 관한 연구 I -스트럿 공법 시공 사례)

  • Do-Hyeong Kim;Dong-Wook Lee;Hee-Bok Choi;Kwon-Moon Ko
    • Journal of the Korean Geosynthetics Society
    • /
    • v.22 no.2
    • /
    • pp.55-61
    • /
    • 2023
  • This paper describes the comparative results of measured and predicted values for the horizontal displacement of earth retaining wall based on two field cases, In order to examine the application of lateral earth pressure to the earth retaining wall considering the typical ground characteristics (clinker layer) in Jeju. The prediction of the lateral earth pressure causing the horizontal displacement of the retaining wall was performed by elasto-plastic analysis using Rankine earth pressure, Terzaghi & Peck modified lateral earth pressure, and Tschebotarioff lateral earth pressure. As a result, it was confirmed that the maximum horizontal displacement predicted at site A was about 5 times larger than the measured value, and the ground with maximum horizontal displacement occurred by the prediction was found to be the clinker layer. In the case of site B, the predicted value was 4 to 7 times larger than the measured value. In addition, the ground with maximum horizontal displacement and the tendency of horizontal displacement were very different depending on the prediction method. This means that research on lateral earth pressure that can consider regional characteristics needs to be continued, because it is due to the multi-layered ground characteristics of the Jeju area in which bedrock layers and clinker layers are alternately distributed,

Numerical Analysis for Lateral Earth Pressure on Retaining Wall with Relieving Platform backfilled with Jumoonjin Sand (주문진 모래로 뒤채움한 선반식 옹벽의 수평토압에 관한 수치해석)

  • Moon, In-Jong;Kim, Byoung-Il;Yoo, Wan-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3916-3922
    • /
    • 2014
  • Generally, the retaining wall is becoming unstable as the height is higher. On the other hand, the retaining wall with the relieving platform is more stable and more economical than any other type of retaining wall, because the relieving platform the reduce the lateral earth pressure. In this study, numerical analyses were carried out for 15 cases varying with the type of retaining wall, length and location of the relieving platform and the backfill type. From the numerical analyses, the reduction of the lateral earth pressure was checked and the results of numerical analyses were compared with that of model tests and theoretical equations. As the results of this study, the lateral earth pressure of the retaining wall with the relieving platform is considerably less than that of cantilever wall. And the of magnitude of the lateral earth pressure is affected by the length and location of relieving platform and the backfill type.

Experimental Study on the application of reinforced retaining walls to the railroad (보강토 옹벽의 철도 구조물 적용에 관한 실험적 연구)

  • Kim Yong-Jun;Kim Jun-Young;Kim Kyung-Taek;Yeom Hyeong-Jin
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1020-1025
    • /
    • 2004
  • This research reviews the characteristics of earth pressure incurred by GRS-RW mainly used in the railroad design in order to resist large lateral load caused by train and additional load induced by facilities such as noise barrier fences, electric poles, etc. The results of test shows the existence of arching effect that horizontal earth pressure increases in the backfill while earth pressure applying to the wall reduced under GRS-RW system. In both cases, unreinforced wall and GRS-RW system, the coefficient of earth pressure (K) is about 0.4 at the rest. However, after lateral displacement occurs, the earth pressure nearly reduce down to zero under GRS-RW system while the earth pressure decreases up to 0.12 in case of unreinforced retaining wall.

  • PDF

A Simple Method for Predicting Lateral Earth Pressure in Consideration of Construction Speed of Embankment (성토 재하속도를 고려한 측방토압의 간이예측법)

  • Im, Eun-Sang;Kim, Hyoung-Soo;Kim, Tae-Hoon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1055-1060
    • /
    • 2005
  • In evaluating the stability of underground structures and designing prevention methods against the lateral flow, it is necessary to predict the amount and the distribution of the lateral earth pressure acting on these retaining structures. However, because the lateral deformation of real ground is a very complex phenomenon influenced by interaction between volumetric deformation bringing an increase of stability of ground and shear deformation causing failure of ground, any appropriate methods for estimating the lateral earth pressure in consideration of the geotechnical properties of ground and the construction conditions in embankment have not been developed as yet. Therefore, a prediction method, which considers effects of a construction speed of embankment, using the Boussinesq's solution based on the elasticity theory without using complex numerical analyses such as finite element analyses is proposed in this research.

  • PDF

Lateral Earth Pressure against Gravity Walls Backfilled by $C-\phi$ Soil ($C-\phi$ 흙으로 뒤채움한 중력식 옹벽에 작용하는 정적토압)

  • Jeong, Seong-Gyo;Heo, Dae-Yeong;Lee, Man-Ryeol
    • Geotechnical Engineering
    • /
    • v.12 no.4
    • /
    • pp.47-60
    • /
    • 1996
  • Of the classical theories on lateral earth pressure, the Coulomb's and the Rankine's theories, which have been usually used in practice for design of retaining walls, assumed that the lateral earth pressure was a triangular distribution. However, the experimental results obtained by Terzaghi(1934), Tsagreli(1967), Fang & Ishibashi(1986), etc showed that lateral pressure were not triangular distribution. ' In this study, for rigid walls with inclined backfaces and inclined surfaces backfilled by $C-\phi$ soils, an analytical method of earth pressure distribution has been newly suggested by using the concept of the flat arch. The results calculated by the newly suggested equations were compared with ones by the existed theories. And'the influence factors of the earth pressures by the suggested equations were investigated. As a result, the thrusts obtained by this method agree well with those by the existing theories, except the Rankine's solution. It was showed that the height to the centre of pressure(h) depends mainly upon the inclinations of the backface and the backfilled surface, the angle of internal friction, and the adhesion between the wall and the backfilled soil, instead of 0.33H, where H is the wall height.

  • PDF