• 제목/요약/키워드: Laser output

검색결과 774건 처리시간 0.029초

Electrical Loss Reduction in Crystalline Silicon Photovoltaic Module Assembly: A Review

  • Chowdhury, Sanchari;Kumar, Mallem;Ju, Minkyu;Kim, Youngkuk;Han, Chang-Soon;Park, Jinshu;Kim, Jaimin;Cho, Young Hyun;Cho, Eun-Chel;Yi, Junsin
    • Current Photovoltaic Research
    • /
    • 제7권4호
    • /
    • pp.111-120
    • /
    • 2019
  • The output power of a crystalline silicon (c-Si) photovoltaic (PV) module is not directly the sum of the powers of its unit cells. There are several losses and gain mechanisms that reduce the total output power when solar cells are encapsulated into solar modules. Theses factors are getting high attention as the high cell efficiency achievement become more complex and expensive. More research works are involved to minimize the "cell-to-module" (CTM) loss. Our paper is aimed to focus on electrical losses due to interconnection and mismatch loss at PV modules. Research study shows that among all reasons of PV module failure 40.7% fails at interconnection. The mismatch loss in modern PV modules is very low (nearly 0.1%) but still lacks in the approach that determines all the contributing factors in mismatch loss. This review paper is related to study of interconnection loss technologies and key factors contributing to mismatch loss during module fabrication. Also, the improved interconnection technologies, understanding the approaches to mitigate the mismatch loss factors are precisely described here. This research study will give the approach of mitigating the loss and enable improvement in reliability of PV modules.

뉴럴네트워크 모델 기반의 IPMC 셀프 센싱 액추에이터 (Self-Sensing Actuator Using an Ion-Polymer Metal Composite Based on a Neural Network Model)

  • 윤종일;딩광졍;안경관
    • 대한기계학회논문집A
    • /
    • 제34권12호
    • /
    • pp.1865-1870
    • /
    • 2010
  • 이 논문에서는 뉴럴네트워크 모델에 기초하여 셀프 센싱이 가능한 IPMC 액추에이터를 개발하고자 한다. IPMC의 양면에 있는 두 개의 지정된 점에서 측정된 입력 전압과 입력 신호들을 뉴럴네트워크 모델의 입력 신호로 사용한다. CCD 레이저 변위 센서는 제시된 뉴럴네트워크 모델의 학습된 출력값으로 사용되는 IPMC 끝의 변위를 정확히 측정하기 위해 설치된다. 결과적으로 뉴럴네트워크 모델은 수집된 입력/출력 학습데이터에 의해 최대한으로 활용된 IPMC의 끝의 변위를 평가하기 위해 만들어진다. IPMC 액추에이터를 위해 설계된 모델의 효율성은 결과들을 모델링함으로서 증명되어진다.

고밀도 파장분할용 전광섬유형 인터리버의 수동 온도보상 (Passive Temperature Compensation for All Optical Fiber Type DWDM Interleaver)

  • 장진현;김영권
    • 대한전자공학회논문지SD
    • /
    • 제41권12호
    • /
    • pp.35-42
    • /
    • 2004
  • Mach Zehnder 간섭계의 원리를 이용하여 두개의 광섬유 커플러를 연결시 두 연결 포트사이에 길이차를 발생시킴으로써 DWDM (Dense Wavelength Division Multiplexer)에 사용할 수 있는 전광섬유형 인터리버(Interleaver)를 제작하였으며 $CO_2$ 레이저를 이용하여 미세 파장조절을 하였다. 광다중화기의 출력중심파장이 주위온도변화에 영향을 받지 않도록 하기 위해서 외부 온도제어기를 사용하지 않은 수동온도보상 패키지가 적용되었다. 열광학 효과를 보상하기 위해서 인터리버 패키지 재질보다 열팽창계수가 큰 기판을 선택하여 온도보상이 되게 하였고 온도보상의 정도는 두 광섬유 커플러 사이의 위치조절을 통하여 이루어 졌다. 결과적으로 $60^{\circ}C$ 정도의 주위온도 변화에 대해서 출력파장 0.05nm이내에서 변하도록 제작 할 수 있다.

고출력 광섬유 레이저를 위한 광섬유 칩 기반 All-fiber 7x1 펌프 광 결합기 제작 (Fabrication of All-fiber 7x1 Pump Combiner Based on a Fiber Chip for High Power Fiber Lasers)

  • 최인석;전민용;서홍석
    • 한국광학회지
    • /
    • 제28권4호
    • /
    • pp.135-140
    • /
    • 2017
  • 본 논문에서는 고출력 광섬유 레이저를 위한 광섬유 칩 기반 all-fiber $7{\times}1$ 펌프 광 결합기의 제작에 대하여 보고한다. 광섬유 칩은 코어, 클래딩 직경이 각각 20, $400{\mu}m$인 광섬유를 길이 방향으로 식각하여 제작하였다. 7개의 입력 광섬유 부분은 105, $125{\mu}m$의 코어, 클래딩 직경을 가진 7개의 입력 광섬유를 원통형 다발로 제작하여 광섬유 칩의 $375{\mu}m$부분에 융착하였고, 1개의 출력 광섬유는 코어, 클래딩 직경이 각각 25, $250{\mu}m$ 광섬유를 광섬유 칩의 $250{\mu}m$부분에 융착하여 최종적으로 $7{\times}1$ 펌프광 결합기를 제작하였다. 제작된 광섬유 칩 기반 $7{\times}1$ 펌프 광 결합기의 포트별 평균 광 전달 효율은 약 90.2%로 나타났다.

100kHz PWM LED 광조사가 백서 골수세포에 미치는 영향 (The effect of 100KHz PWM LED light irradiation on RAT bone-marrow cells)

  • 천민우;김성환;김영표;이호식;박용필;유성미;이희갑;김태곤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.512-513
    • /
    • 2008
  • The study examined what effects 100kHz PWM LED light irradiation causes to bone marrow cells of SD-Rat when LED characterized cheap and safe is used onto the light therapy by replacing the low 1evel laser. We developed the equipment palpating cell proliferation using a high brightness LED. This equipment was fabricated using a micro-controller and a high brightness LED, and designed to enable us to control light irradiation time, intensity, frequency and so on. Especially, to control the light irradiation frequency, FPGA was used, and to control the change of output value, TLC5941 was used. Consequent1y, the current value could be controlled by the change of 1eve1 in Continue Wave(CW) and Pulse Width Modulation(PWM), and the output of a high brightness LED could be controlled stage by stage. MTT assay method was chosen to verify the cell increase of two groups and the effect of irradiation on cell proliferation was examined by measuring 590nm transmittance of ELISA reader. As a result, the cell increase of Rat bone marrow cells was verified in 100kHz PWM LED light irradiation group as compared to non-irradiation group.

  • PDF

경혈 위치교육 평가지원시스템의 개발계획 수립과 제작 (Development Plan of a Human Model System for Educating Acupoint Location and Its Implementation)

  • 여수정;남동현
    • Korean Journal of Acupuncture
    • /
    • 제36권1호
    • /
    • pp.44-51
    • /
    • 2019
  • Objectives : Teaching the standardized acupuncture point locations and improving the accuracy of acupoint locations through objective evaluation is a very important part of Korean medicine education. The aim of this study is to develop a dummy system for evaluation and support of teaching acupoint location in meridian and acupoints classes and to introduce the developed system. Methods : We established a protocol for the development of the system. The protocol included definition of usage purpose, definition of its essential performance, and set of scope. The system compares the amount of light at the target acupoint with the amount of light at the other sites to determine whether the target acupoint is properly specificated. Results : A prototype of the system was built according to the protocol and consists of light emitter, dummy, control/operation, input part and output part. The light emitter projects laser beam passing through the skin of the dummy. Light sensors were attached inside the acupoints of the dummy. Three types of light sensors were selected depending on the location of the acupoints. The arithmetic, input, and output parts were constructed using Arduino and Raspberry pi boards. The developed system was applied in class. Conclusions : It is thought that the dummy system for evaluation and support of teaching acupoint location can be used as a training model in order to help teach standardized acupoint locations and objective evaluation.

A Hybrid Semantic-Geometric Approach for Clutter-Resistant Floorplan Generation from Building Point Clouds

  • Kim, Seongyong;Yajima, Yosuke;Park, Jisoo;Chen, Jingdao;Cho, Yong K.
    • 국제학술발표논문집
    • /
    • The 9th International Conference on Construction Engineering and Project Management
    • /
    • pp.792-799
    • /
    • 2022
  • Building Information Modeling (BIM) technology is a key component of modern construction engineering and project management workflows. As-is BIM models that represent the spatial reality of a project site can offer crucial information to stakeholders for construction progress monitoring, error checking, and building maintenance purposes. Geometric methods for automatically converting raw scan data into BIM models (Scan-to-BIM) often fail to make use of higher-level semantic information in the data. Whereas, semantic segmentation methods only output labels at the point level without creating object level models that is necessary for BIM. To address these issues, this research proposes a hybrid semantic-geometric approach for clutter-resistant floorplan generation from laser-scanned building point clouds. The input point clouds are first pre-processed by normalizing the coordinate system and removing outliers. Then, a semantic segmentation network based on PointNet++ is used to label each point as ceiling, floor, wall, door, stair, and clutter. The clutter points are removed whereas the wall, door, and stair points are used for 2D floorplan generation. A region-growing segmentation algorithm paired with geometric reasoning rules is applied to group the points together into individual building elements. Finally, a 2-fold Random Sample Consensus (RANSAC) algorithm is applied to parameterize the building elements into 2D lines which are used to create the output floorplan. The proposed method is evaluated using the metrics of precision, recall, Intersection-over-Union (IOU), Betti error, and warping error.

  • PDF

국내 시판되는 16가지 연무기/압축기의 성능 평가 (Comparison of the Characteristics of 16 Commercial Nebulizer/Compressor Combinations Used in Korea)

  • 김현정;이초애;황은경;한만용;안욱성;조영민
    • Clinical and Experimental Pediatrics
    • /
    • 제46권12호
    • /
    • pp.1235-1241
    • /
    • 2003
  • 목 적 : 현재 시중에 판매되고 있는 연무기 기종에 따라 그 성능이 다를 것으로 보고 제품 선택에 도움이 되고자 국내 시판중인 16가지 연무기 기종의 성능을 실험을 통하여 비교하였다. 방 법 : 16가지 연무기/압축기 제품(Pariboy Type 38/Long life, Pariboy Type N/Long life, Pariboy Type N/Salter 8900, Pariboy Type N/LC, Devilbiss pulmoaid-LT/Hudson, Devilbiss pulmoaid/Hudson, Mesmed neb-300/Own, San-up 3040/Hudson, Midas(Basic)/Own, AirJolie2/Hudson, Thomas 1127/Salter 8900, Noel NE-2000/Salter 8900, Omron CX3/Hudson, Chang Woo CWN-100/Salter 8900, Voyage/Mefar, ASI-Pro/Medel jet pluse)을 가지고 Mass output과 입자 크기를 측정하였다. Mass output은 생리식염수 4 mL를 2분간 분무 전, 후의 무게변화를 정밀 전자저울로 측정하였다. 동일한 방법으로 생리식염수 3 mL를 채워 실험하였다. 입자의 크기는 0.9% 생리식염수 4 mL를 채우고 5분간 작동하면서 laser diffraction법을 이용하여 측정하였다. 결 과 : 분당흡입량은 Pariboy type N/Long life이 0.184 mg/min로 가장 높은 값을 보였으며 0.019 mg/min로 가장 낮은 수치를 나타낸 Mesmed Neb-300/Own과는 약 9.6배의 차이를 보였다. Pariboy Type N/Long life이 Mass output이 0.68 mg/min로 가장 컸고 0.13 mg/min으로 가장 작은 수치를 보인 Mesmed-Neb/Own과는 5.2 배 차이가 있었다. 모든 제품은 5분간의 입자의 크기를 측정하였으나 검사시간 동안 입자크기의 차이는 보이지 않았다. $5{\mu}m$ 이하의 입자크기의 최대값은 64%였고 최소값의 연무기는 20%였다. MMAD는 Pariboy Type N/Long life이 $3.76{\mu}m$로 가장 작았으며 나머지 제품은 모두 $5{\mu}m$ 이상이었다. 결 론 : 시중에 판매되는 연무기들의 기능이 다양하므로 제품의 선택에 있어서 그 성능을 고려할 필요가 있다.

요골동맥 직경 변화에 따른 맥파 측정 시스템 개발 (Development of an Measuring System for Pulse Wave Corresponding to Different Radial Artery Diameters Caused by Indentation)

  • 이전;우영재;전영주;이유정;김종열
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2351-2357
    • /
    • 2008
  • Noninvasive radial artery pulse wave has been widely used not only for the pulse wave analysis(PWA) itself but also for assessment of arterial stiffness with estimated aortic pulse wave from peripheral pulse wave. However, it has been found that the deformation of pulse shape can be caused readily by changing measuring position, indentation pressure, and so on. So, in this study, we have developed a system which can measure radial pulse wave and skin displacement simultaneously while the indentation body goes down to occlude subject's radial artery. This system can be divided into a measuring apparatus part, an indentation control hardware part, a data acquisition part and a control and computation part. And, the measuring apparatus consists of an arm-rest, a step motor, an indentation body, a laser displacement sensor(LK-G30, Keyence Co.) and pulse wave sensor. Under load-free condition and radial artery loaded condition, the evaluation of developed system has been performed. From these results, we can conclude: 1) The developed system can control the indentation body quantitatively and the adopted laser displacement sensor shows linear output characteristic even with skin as a reflector. 2) This system can measure the pulse wave and the displacement of indentation body, that is, skin displacement simultaneously at each specific level of indentation body. 3) This system can provide the number of motor steps used to get down the indentation body, the measured skin displacement, the calculated indentation pressure, the calculated pulse pressure and the pulse waveform as well as the information generated by combining these with each others. 4) This system can reveal the relationship between the morphological changes of pulse wave and the estimated displacement of radial artery wall by indentation. Consequently, the developed system can furnish more abundant information on radial artery than previous diagnosis systems based on tonometric measurement. In further study, we expect to setup the standard measuring process and to concrete the algorithm for the estimation of radial artery's diameter and of displacement of radial artery's wall. Furthermore, with well designed clinical studies, we hope to turn out the usefulness of developed system in the field of cardiovascular system evaluation.

온도변화에 따른 광CT의 출력 특성 (The optical CT output signal characteristic according to temperature change)

  • 손현목;안미경;허순영;전재일;박원주;이광식;김정배;김민수
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.29-33
    • /
    • 2004
  • 본 논문에서는 패러데이 효과(Faraday effect)를 이용한 초고압 전력설비에서의 대전류 측정을 위한 광CT의 특성에 대한 기초 연구를 기술하였다. 1310[nm] Laser Diode를 광원으로 사용하고 PIN-Photodiode를 수신부로 사용하였다. 광의 전송로는 파이버 내에서 편광상태를 유지 할 수 있는 30[m]의 싱글모드 파이버를 사용하였다. 전류의 측정은 400[A]에서 1300[A]까지의 범위에서 측정하였으며 온도는 $20[^{\circ}C]$에서 $50[^{\circ}C]$까지 측정하였다. 동일한 실험 환경 하에서 출력의 크기는 인가전류가 증가할수록, 온도가 낮을수록 비례하여 증가하였다. 온도가 $50[^{\circ}C]$의 경우 최대 $50[^{\circ}C]$의 오차율을 나타냈으며, $40[^{\circ}C],\;30[^{\circ}C],\;20[^{\circ}C]$의 경우 각각 최대 오차 0.16[%], 1.24[%], 0.07[%]의 오차율을 보였다.

  • PDF