• Title/Summary/Keyword: Laser desorption/ionization

Search Result 246, Processing Time 0.025 seconds

Rapid Surface Heating Promotes Laser Desorption Ionization of Thermally Labile Molecules from Surfaces

  • Han, Sang Yun
    • Mass Spectrometry Letters
    • /
    • v.7 no.4
    • /
    • pp.91-95
    • /
    • 2016
  • In recent years, matrix-free laser desorption ionization (LDI) for mass spectrometry of thermally labile molecules has been an important research subject in the pursuit of new ionization methods to serve as alternatives to the conventional matrix-assisted laser desorption ionization (MALDI) method. While many recent studies have reported successful LDI of thermally labile molecules from various surfaces, mostly from surfaces with nanostructures, understanding of what drives the LDI process still requires further study. This article briefly reviews the thermal aspects involved in the LDI mechanism, which can be characterized as rapid surface heating. The thermal mechanism was supported by observed LDI and postsource decay (PSD) of peptide ions produced from flat surfaces with special thermal properties including amorphous Si (a-Si) and tungsten silicide ($WSi_x$). In addition, the concept of rapid surface heating further suggests a practical strategy for the preparation of LDI sample plates, which allows us to choose various surface materials including crystalline Si (c-Si) and Au tailorable to specific applications.

Observation of Peptide-Ion Generation by Laser-Induced Surface Heating from Tungsten Silicide Surfaces

  • Kim, Shin-Hye;Park, Sun-Hwa;Song, Jae-Yong;Han, Sang-Yun
    • Mass Spectrometry Letters
    • /
    • v.3 no.1
    • /
    • pp.18-20
    • /
    • 2012
  • We report observation of laser desorption/ionization (LDI) of peptides from flat surfaces of tungsten silicide ($WSi_2$). In contrast to MALDI (matrix-assisted laser desorption/ionization) and SALDI (surface-assisted laser desorption/ionization) mass spectrometry, this study did not utilize any matrices and surface nanostructures. In this work, LDI on $WSi_2$ surfaces is demonstrated to cover a mass range up to 1,600 Da (somatostatin; monoisotopic mass = 1637.9 Da). In addition, it exhibited a high sensitivity, which could detect peptides, which could detect peptides of low femtomole levels (20 fmol for angiotensin II). The observed LDI process was discussed to be largely thermal, more specifically, due to laser-induced surface heating that is most likely promoted by the low thermal diffusivity (${\kappa}$) of $WSi_2$ substrate.

Use of Graphite Plate for Homogeneous Sample Preparation in Matrix/Surface-assisted Laser Desorption and Ionization of Polypropyleneglycol and Polystyrene

  • Kim, Jeong Hwan;Gang, Wi Gyeong
    • Bulletin of the Korean Chemical Society
    • /
    • v.21 no.4
    • /
    • pp.401-404
    • /
    • 2000
  • Matrix/Surface-assisted laser desorption/ionization (M/SALDI) mass spectrometry of polypropylene glycol and polystyrene, directly deposited on graphite plate, is demonstrated. Graphite plate is effective both as an en-ergy transfer medium and robu st sampling support for LDI of polymers. Mass spectra ofpolymers can be easily obtained due to homogeneous distribution on graphite surface and their ion signals are long-lived by large ef-fective desorption volume enough to investigate M/SALDI process.

Enhancement of Analyte Ionization in Desoprtion/Ionization on Porous Silicon (DIOS)-Mass Spectrometry(MS)

  • Lee Chang-Soo;Kim Eun-Mi;Lee Sang-Ho;KIm Min-Soo;Kim Yong-Kweon;Kim Byug-Gee
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.10 no.3
    • /
    • pp.212-217
    • /
    • 2005
  • Desorption/ionization on silicon mass spectrometry (DIOS-MS) is a relatively new laser desorption/ionization technique for mass spectrometry without employing an organic matrix. This present study was carried to survey the experimental factors to improve the efficiency of DIOS-MS through electrochemical etching condition in structure and morphological properties of the porous silicon. The porous structure of silicon structure and its properties are crucial for the better performance of DIOS-MS and they can be controlled by the suitable selection of electrochemical conditions. The fabrication of porous silicon and ion signals on DIOS-MS were examined as a function of silicon orientation, etching time, etchant, current flux, irradiation, pore size, and pore depth. We have also examined the effect of pre- and post-etching conditions for their effect on DIOS-MS. Finally, we could optimize the electrochemical conditions for the efficient performance of DIOS-MS in the analysis of small molecule such as amino acid, drug and peptides without any unknown noise or fragmentation.

Sequence Coverage Enhancement Using Magnetic Nanoparticles in Matrix-Assisted Laser Desorption/Ionization Mass Spectrometric Protein Analysis

  • Park, Eun-Hye;Song, Jin-Su;Kim, Hie-Joon
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.3
    • /
    • pp.987-992
    • /
    • 2012
  • Magnetic nanoparticles (MNPs) treated with phosphoric acid were used to improve sequence coverage in protein identification by matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS). Sample solution of tryptic peptides from proteins was mixed with the MNPs, and the MNPs were separated from the supernatant using a magnet. MALDI mass spectra obtained separately from the supernatant and the MNPs were distinctly different and complementary to each other. Combination of the two spectra led to a significantly increased sequence coverage.

Sequence Verification of Synthetic Oligonucleotides by Exonuclease Digestion and Matrix Assisted Laser Desorption Ionization Mass Spectrometry

  • Kim, Jin-Sung;Jang, Jung-Suk;Choi, Jong-Soon;Chang, Yoon-Seok
    • BMB Reports
    • /
    • v.29 no.2
    • /
    • pp.122-126
    • /
    • 1996
  • A series of oligonucleotides were synthesized by automatic DNA synthesizer. The purity of crude products was checked and their molecular weights determined by matrix assisted laser desorption ionization mass spectrometry (MALDI-MS) with an accuracy of better than 0.05% deviation even without using an internal standard. This mass determining technology in combination with partial digestion of oligonucleotides by 5'- and 3'-exonuclease provides a straightforward and simple method to obtain sequence information of oligonucleotides. The extension of this technology to the sequencing of modified oligonucleotides and genomic DNA and RNA might become possible.

  • PDF

Detection of Small Neutral Carbohydrates Using Various Supporting Materials in Laser Desorption/Ionization Mass Spectrometry

  • Yang, Hyo-Jik;Lee, Ae-Ra;Lee, Myung-Ki;Kim, Woong;Kim, Jeong-Kwon
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.1
    • /
    • pp.35-40
    • /
    • 2010
  • A comprehensive comparative investigation of small carbohydrates in laser desorption ionization was performed on supporting materials composed of sodiated 2,5-dihydroxybenzoic acid (DHB), carbon nanotubes, an ionic liquid matrix of DHB-pyridine, a binary matrix of DHB-aminopyrazine, zinc oxide nanoparticles, and gold nanoparticles. The abundance of $[M+Na]^+$ ions, where M is glucose or sucrose, was compared for each supporting material. The highest sensitivity for both glucose and sucrose, with a detection limit of 3 pmol, was observed with carbon nanotubes. Both carbon nanotubes and the ionic liquid matrix exhibited the highest reproducibility.

Application of Malononitrile Derivatization Method for Structural Glycomics Study in Matrix-assisted Laser Desorption/Ionization Time-of-flight Mass Spectrometry

  • Ahn, Yeong-Hee;Yoo, Jong-Shin
    • Journal of Photoscience
    • /
    • v.8 no.2
    • /
    • pp.83-86
    • /
    • 2001
  • Structural analyses of oligosaccharide-malononitrile derivatives were conducted by matrix-assisted laser desorption/ionization post-source decay (MALDI-PSD) analysis in positive ion mode. The malononitrile derivatives of oligosaccharides, which were developed for highly sensitive detection of multi-component oligosaccharides by negative ion electrospray ionization mass spectrometry (ESI MS), were detected by positive-ion MALDI with the detection limit of 2 pmol level from the crude derivatization sample. The used matrix affected drastically the analytical results of oligosaccharide-malononitrile derivative by matrix-assisted laser desoprtion/ionization mass spectrometry (MALDI MS). The malononitrile derivatization of oligosaccharide also affect the patterns of MALDI-PSD spectra and give much more structural information than the free oligosaccharide.

  • PDF