• Title/Summary/Keyword: Laser Doppler flowmeter.

Search Result 38, Processing Time 0.027 seconds

THE USE OF LASER DOPPLER FLOWMETER FOR PULP VITALITY TEST (치수생활력 검사를 위한 Laser Doppler Flowmeter의 이용)

  • Su, Wan-Jong;Kim, Hyun-Jung;Nam, Soon-Hyeun;Kim, Young-Jin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.3
    • /
    • pp.562-568
    • /
    • 1998
  • Various diagnostic methods, such as electric pulp test, cold test, test cavity etc., have been used to determine the pulp vitality. At least two or more methods should be used with supplemental information to diagnose each case because using one method doesn't provide sufficient accuracy. These conventional methods have depended on nervous responses, but Laser Doppler Flowmeter determines the pulp vitality by measuring pulpal blood flow. In this case, we tested the vitality of the traumatized teeth with incomplete root apices and autotransplanted teeth with conventional methods and Laser Doppler Flowmeter. Conventional methods, such as electric pulp test and cold test can produce various responses according to the development state of the pulpal nerve and the sensory threshold of the patient. But, Laser Doppler Flowmeter has a lower false response rate than any other pulp vitality test methods and it can determine the vitality somewhat earlier than the other method.

  • PDF

MEASUREMENT OF PULPAL BLOOD FLOW USING A LASER DOPPLER FLOWMETER (Laser Doppler flowmeter를 이용한 치수혈류 측정)

  • Ban, Tae-Whan;Lee, Jae-Sang;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.4
    • /
    • pp.560-569
    • /
    • 1999
  • Blood supply rather than nerve supply implies pulp vitality. To evaluate pulp vitality clinically, electric pulp test and thermal test which are based on sensory nerve response have been used in addition to many auxiliary data such as past dental history, visual inspection, radiographic examination, percussion, palpation and transillumination test. However, reactivity of the nerves to the stimulation is not synonymous with normalcy. Therefore measurement of pulpal blood flow using a laser Doppler flowmeter became a new trial to test the pulp vitality. The purpose of the present study was to evaluate normal pulpal blood flow level of maxillary teeth in adult to provide a guideline in determining the vitality of dental pulp. Pulpal blood flow was measured in maxillary central and lateral incisors, canines, first and second premolars and first molars of seventy nine adults of 22 - 30 years old using a laser Doppler flowmeter (PeriFlux 4001, Perimed Co., Stockholm, Sweden, 780 nm infrared laser, 1mW). For directly-made splints, silicone rubber impressions were taken directly from the mouth. For indirectly-made splints, alginate impressions were taken from the mouth and stone cast were made. After making depressions on the buccal surfaces of the cast teeth to indicate the hole positions, second impressions with vinyl polysyloxane putty were taken from the cast. Holes for the laser probes were made at the putty impressions 4mm above the gingival level. Laser probe (PF416 dental probe, 1.5mm) was inserted in the prepared hole and the splint was set in the mouth. After 10 minutes of patient relaxing, pulpal blood flow was recorded for 5 minutes on each tooth. The recorded flow was saved in the computer and calculated with a software 'Perisoft' version 5.1. Pulpal blood flow was also recorded in six teeth of five individuals with no response to electric pulp test and cold test, with periapical radiolucency, or with history of root canal treatment to compare with nonvital teeth. The difference between the mean flow values of each group of teeth were analyzed using one-way ANOVA and Duncan's Multiple Range test. The results were as follows: 1. The average pulpal blood flow values of all the tested teeth of each location were between 9 - 16 Perfusion Unit. Pulpal blood flow value was highest in maxillary lateral incisors, followed by first premolars, second premolars, canines, central incisors, and then first molars (p<0.01). 2. In six anterior teeth, indirectly-made splint group showed higher pulpal blood flow values than directly-made splint group (p<0.01). In posterior teeth, however, there was no significant flow value difference between directly-made splint group and indirectly-made splint one (p>0.05). 3. Teeth with vital pulps showed higher signal values than teeth with nonvital pulps (p<0.01), and the flow photographs showed heartbeat-synchronous fluctuations and vasomotions, while those were absent in non vital tooth.

  • PDF

RELATIONSHIP BETWEEN LASER DOPPLER FLOWMETER OUTPUT AND STAGE OF ROOT DEVELOPMENT (치근 발육정도와 Laser Doppler Flowmeter 측정치의 상호 관련성)

  • Su, Wan-Jong;Kim, Hyun-Jung;Kim, Young-Jin;Nam, Soon-Hyeun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.2
    • /
    • pp.437-445
    • /
    • 1999
  • The purpose of this study was to evaluate the changes of laser doppler flowmeter output associated with stage of root development. Laser Doppler Flowmeter was done in 40 elementary students aged between 7 and 8 years and in 20 adults aged between 23 and 24 years. Among 40 elementary students, 20 had apical foramens with $1{\sim}2mm$ diameters and another 20 had ones with larger diameters than 2mm. The LDF values were analyzed with ANOVA and paired t-test. The results were as follows. 1. Immature root apecies group had a higher tendency than mature root apecies group in LDF values, but there was no statistical significance (p>0.05). 2. There was no statistical significance in LDF values comparing groups with immature root apecies (p>0.05). 3. There were no significant differences between right and left central incisors in LDF values (p>0.05).

  • PDF

THE RELIABILITY OF LASER DOPPLER FLOWMETER IN PULP VITALITY TEST OF TEETH (치수생활력 검사 방법으로서 laser Doppler flowmeter의 신뢰도)

  • Nam, Dong-Woo;Kim, Young-Jin;Nam, Soon-Hyeun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.4
    • /
    • pp.683-690
    • /
    • 1998
  • The purpose of this study was to evaluate the reliablity of laser Doppler flowmeter on the permanent maxillary central incisors with open apex. Laser Doppler flowmeter and electric pulp tests were done in 35 elementary students aged between 8 and 9 years and 35 females and males aged between 23 and 24 years. Teeth with open apex were confined to root developmental stage 5 and 6 by Moorrees classification. The threshold of electric pulp tests was decided the time of tingling sensation. More than three different electric pulp tests applied on every teeth with more than 3 minutes interval between each teeth due to the false response. Laser Doppler flowmeter test stablilzation and observation stages took more than 5 minutes each LDF values and electric pulp test thresholds were analyzed with student t-test. The results were as follows: 1. The electric pulp test threshold on teeth with immature and mature roots showed 28.4% and 100% response respectively, and the the LDF values on teeth with immature and mature roots showed 100% response. 2. The EPT thresholds on teeth with immature roots were larger than thresholds on teeth with mature roots(p<0.01). 3. No significant differences were found in the LDF values on teeth with immature and mature roots.

  • PDF

Laser Doppler blood flowmeter using self-mixing effect for the measurement of tissue blood flow. (조직혈류측정을 위한 자기혼합형 레이저 도플러 혈류계의 검토.)

  • Ko, Han-Woo;Choi, Duck-Hee
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.11
    • /
    • pp.67-70
    • /
    • 1993
  • This preliminary study describes the self-mixing effect of laser diode for the measurement of tissue blood flow. A self-mixing effect of laser diode was detected by the single-mode laser diode and the moving target, and the Doppler shifted frequency was thanked linearly with the driving frequency of speaker. The measured Doppler shifted frequency was compared with the simulated data.

  • PDF

Implementation of a self-mixing type LDF probe and blood flow simulator (자기혼합형 LDF 프로브와 혈류 시뮬레이터의 구현)

  • Ko, Han-Woo;Kim, Jong-Weon
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.133-138
    • /
    • 1999
  • In this pager, the authors have implemented a blood flow simulator and a LDF(laser Doppler flowmeter) probe using self-mixing effect of the laser diode. The purpose of the blood flow simulator is to simulate microvascular blood flow in tissue. It consists of melinex film (thickness = $123\;{\mu}m$) which has similar optical characteristics to epidermis and porous polyethylene filter (Vyon, porosity 35%, mean pore size $50\;{\mu}m$, thickness=1 mm) which has similar optical characteristics to dermis. The blood flowmeter probe consists of laser diode(5 mW, 780 nm wavelength), CD lens(focal length 12 mm). current-to-voltage converter, highpass filter, and premplifier. It doesn't need optical fiber, therefore, implementation of the probe is simpler than conventional probe using optical fiber.

  • PDF

Stellate Ganglion Blocks in Atrophic Rhinitis (위축성 비염 환자에서 성상신경절 블록의 치료효과 -증례 보고-)

  • Kim, Seung-Jun;Lee, Woo-Chang;Chang, Won-Sok;Yoon, Duck-Mi
    • The Korean Journal of Pain
    • /
    • v.14 no.2
    • /
    • pp.231-233
    • /
    • 2001
  • Atrophic rhinitis is characterized by mucosal atrophy, bony absorption, persistent fetid odor and resistance to medical and surgical treatment. Stellate ganglion block (SGB) can be used as a therapeutic modality by improving the regional blood flow through sympathetic blockade. We present a case of a 57 year-old male patient who had been treated unsuccessully for atrophic rhinitis for several years by surgical and conservative measures. The patient presented at our pain clinic with shoulder pain and received stellate ganglion block once or twice a week. He received more than 75 SGBs in addition to the routine conservative treatment for atrophic rhinitis. As the number of blocks performed increased, the patient demonstrated subjective symptom relief. We measured regional mucosal blood flow using a laser doppler flowmeter after the 28th, 63rd and 75th blocks. Nasal mucosal blood flow was improved by 4.9%, 28.8% and 36.3% respectively. We also were able to observe the recovery of mucosal atrophy to an almost normal level by nasal endoscopy. The patient is currently free of symptoms and is being followed up on an outpatient bases.

  • PDF

A Study of Microvascular Changes in Masticatory Muscles of Myofascial Pain Patients During Music Listening (근막동통 환자의 측두근에서 측정된 음악에 의한 혈액관류 변화)

  • Kwon, Eun-Hyung;Lee, Ju-Young;Chun, Yang-Hyun;Hong, Jung-Pyo
    • Journal of Oral Medicine and Pain
    • /
    • v.31 no.1
    • /
    • pp.37-45
    • /
    • 2006
  • The use of music as a means of inducing positive emotions and subsequent relaxation has been extensively studied by researchers. A great deal of this research has focussed on the use of music as a means of reducing feelings of anxiety and stress as well as aiding in the relief of numerous pathologies. The purpose of this study was to evaluate this effect of music using laser doppler flowmeter that monitors relative changes in the muscular blood cell perfusion, concentration of moving blood cells, mean velocity of the myofascial pain disorder patients. Total of 30 subjects were selected. They were monitored by LDF(Laser Doppler Flowmeter) during music listening for 3 minutes. LDF probe was placed over the temporalis muscle. The obtained results were as follows: 1. The average blood perfusion for 3 minutes of music listening at surface of temporalis muscles were elevated on both affected and unaffected parts compared to rest time. 2. The average of blood perfusion elevated during music listening at surface of temporalis muscles were higher in affected part than unaffected part. 3. Increase of blood perfusion during music listening is proportioin to that before music listening. In summary, these results may encouraging start to the elucidation of the hemodynamic events occuring during music listening and aimed to serve as a base for further studies.

Evaluation of Skin Microcirculation by Laser Doppler Flowmeter in Healthy Beagle Dogs

  • Kim, Juntaek;Bae, Seulgi;Lee, Keunwoo;OH, Taeho
    • Journal of Veterinary Clinics
    • /
    • v.34 no.4
    • /
    • pp.249-254
    • /
    • 2017
  • The cutaneous microcirculation plays a role in various physiological processes and pathological conditions. Two non-invasive methods were used in this study to obtain reference values for cutaneous microcirculation in intact male beagles. Twenty intact male beagles were used. The experimental environments were standardized. Laser Doppler flowmetry was used to measure cutaneous blood flow, and an infrared thermometer was used to measure cutaneous temperature. The blood flow and temperature were measured from the right side of the subjects at 20 cutaneous sites. Based on the laser Doppler flowmetry, the region with the highest blood flow was the periocular region that with the lowest was the forelimb foot pad. In addition, the standard deviation of the chest wall was the highest while that of the periocular region was the lowest. For skin temperature, the inguinal region had the highest mean skin temperature and the forelimb foot pad had the lowest. The correlation coefficient between the two methods was 0.72. Similar to a previous study, the values derived from repeated measurements at the 20 regions are reproducible and can contribute to research. Compared to the results of a previous study, the temperatures of the two smallest skin regions were the same; however, no specific trend was observed. The correlation coefficient between the two methods was significantly comparable, and this good correlation can reduce their limitations and variables complementarily. In addition to possible use in human studies, accumulated resources on measurements of skin blood flow in the future will potentiate its use in the veterinary medicine field.

The classification of neuropathic and thyroid function of the diabetic using amplitude-spectrum-density analysis in peripheral blood vessels (말초혈관 혈류에서 진폭-스펙트럼-밀도 분석에 의한 당뇨병에서의 신경병증 및 갑상선 기능 유무 분류)

  • 남상희;최준영
    • Progress in Medical Physics
    • /
    • v.9 no.1
    • /
    • pp.23-28
    • /
    • 1998
  • We measured the flow at peripheral blood vessel of finger dorsum surface using noninvasive LDF(Laser Doppler Flowmeter). We investigated the flow properties between the normal and the diabetic with the Amplitude Spectral Densities of FFT analysis. We classified the diabetic as four groups of negative neuropathy, positive neuropathy, hyperthyroid and hypothyroid. And tested the neuropathic and thyroid effects of peripheral blood flow. As the results, the diabetic, the positive neuropathic and the hypothyroid respectively showed the abnormal blood flow properties on the contrary of the normal flow of negative neuropathic and hyperthyroid.

  • PDF