• 제목/요약/키워드: Large-area measurement

검색결과 361건 처리시간 0.026초

방사능 측정장치 운영 기술 및 측정정보 통합관리 시스템 개발 (Development of Operational Technology and Integrated Measurement Information Management System for the Radioactivity Measurement Device)

  • 진동식;김경령;이재근
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권3호
    • /
    • pp.183-195
    • /
    • 2024
  • Additional functional upgrades to the large-area compton camera (LACC) measurement device that can provide characteristics evaluation information (nuclear species and radioactivity) and two-dimensional or three-dimensional distribution imaging information of radioactive materials existing in surface or internal of concrete structures are required in terms of work stability and efficiency in order to apply to actual decommissioning sites such as nuclear power plants or medical cyclotron facilities by using this measurement device. To this purpose, the technology that allows radiation workers to intuitively and visually check the distribution of radioactive materials in advance by matching the two-dimensional distribution imaging information of radioactive materials obtained through the LACC measurement device and visual imaging of the measurement zone (10 m × 5 m) was developed. In addition, the separate system that can automatically adjust the position (height) in units of the measurement area size (0.7 m × 0.3 m × 0.8 m) of the LACC measurement device was developed and the integrated management system for characteristics evaluation information and two-dimensional or three-dimensional distribution imaging information obtained per unit of measurement for radioactive materials was developed. These functional upgrades related to LACC measurement device can improve work efficiency and safety when measuring radioactivity of concrete structures and enable the establishment of appropriate decommissioning strategies using radioactivity measurement information for decommissioning nuclear power plants or medical cyclotron facilities.

노년기 여성의 체형 연구에 대한 이론적 분석 (A Theoretical Analysis on Somatotyping of Elderly Women)

  • 이은정
    • 한국패션뷰티학회지
    • /
    • 제4권1호
    • /
    • pp.35-41
    • /
    • 2006
  • From 1995 to 2005 the information related to clothing and textiles publicized by 6 journals regarding Elder Women's body type was collected and analyzed. The results are as follows. 1. It has been investigated into the elder woman's body type since 1995, and this subject needs a detailed study. in audition, investigation into woman's body type has been studied parts of the body for clothing construction. 2. Analysis result for measure area preponderance(Seoul area and local metropolitan city) of area, measure subject number mainly to large scale group more than 300 people that measure is consisting most know can. 3. Where the way of measurement is concerned, there are direct measurements more than indirect measurements. In case of using just direct measurement, the study often mentions necessity of indirect measurements. Therefore it is thought simultaneous measurement is the most desirable. 4. A Body type characteristic of elder woman shows a size of every part diminishes as growing older. Owing mainly to obesity of waist and abdomen, they have a changed body a measure of around the abdomen is bigger than around the hips. hips drop and the upper half of the body down, and besides, feet are changed into the flat.

  • PDF

서울지역 미세먼지의 실시간 고해상도 모니터링 방안 (Real-time High Resolution PM Monitoring in Seoul)

  • 강두수;봉춘근;김대성
    • 한국입자에어로졸학회지
    • /
    • 제15권2호
    • /
    • pp.67-78
    • /
    • 2019
  • Since existing measurement sites are required to construct a high-cost PM measuring device and a measuring site of a large area, there is a limit to the construction of a high-resolution measurement network. Therefore, it is necessary to develop a low-cost, high-performance PM measuring device (as an alternative technology) that can increase the resolution of PM measurement, and it is necessary to establish a base to provide real-time PM information for whole people. Therefore, in this study, the alternative technique (light scattering method) for achieving the above object was examined, performance evaluation was carried out, and it was verified that the light scattering method was usable. Various PM measurement results were compared and analyzed to find PM monitoring points and resolutions we would like to propose.

ANALYSIS OF THIN FILM POLYSILICON ON GLASS SYNTHESIZED BY MAGNETRON SPUTTERING

  • Min J. Jung;Yun M. Chung;Lee, Yong J.;Jeon G. Han
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2001년도 추계학술발표회 초록집
    • /
    • pp.68-68
    • /
    • 2001
  • Thin films of polycrystalline silicon (poly-Si) is a promising material for use in large-area electronic devices. Especially, the poly-Si can be used in high resolution and integrated active-matrix liquid-crystal displays (AMLCDs) and active matrix organic light-emitting diodes (AMOLEDs) because of its high mobility compared to hydrogenated _amorphous silicon (a-Si:H). A number of techniques have been proposed during the past several years to achieve poly-Si on large-area glass substrate. However, the conventional method for fabrication of poly-Si could not apply for glass instead of wafer or quartz substrate. Because the conventional method, low pressure chemical vapor deposition (LPCVD) has a high deposition temperature ($600^{\circ}C-1000^{\circ}C$) and solid phase crystallization (SPC) has a high annealing temperature ($600^{\circ}C-700^{\circ}C$). And also these are required time-consuming processes, which are too long to prevent the thermal damage of corning glass such as bending and fracture. The deposition of silicon thin films on low-cost foreign substrates has recently become a major objective in the search for processes having energy consumption and reaching a better cost evaluation. Hence, combining inexpensive deposition techniques with the growth of crystalline silicon seems to be a straightforward way of ensuring reduced production costs of large-area electronic devices. We have deposited crystalline poly-Si thin films on soda -lime glass and SiOz glass substrate as deposited by PVD at low substrate temperature using high power, magnetron sputtering method. The epitaxial orientation, microstructual characteristics and surface properties of the films were analyzed by TEM, XRD, and AFM. For the electrical characterization of these films, its properties were obtained from the Hall effect measurement by the Van der Pauw measurement.

  • PDF

밭작물의 엽면적지수(LAI)에 대한 이론 및 측정기술 (Theories and Measurement Techniques for LAI of Crops)

  • 박종화;이상혁;신용희;박민서
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2002년도 학술발표회 발표논문집
    • /
    • pp.21-24
    • /
    • 2002
  • Many methods are available to measure leaf area index(LAI) directly and are variations of either Leaf area index(LAI) and leaf angle distribution are widely used indices of canopy structure that are difficult to measure directly. Direct measurements of canopy structure are tedious and labor intensive in small canopies and nearly impossible in large forest canopies. This study introduced fundamental theories in LAI measurements and applied that for several crops.

  • PDF

2MN 유압식 힘 표준기의 설계 및 제작 (Design and fabrication of 2MN hydraulic force standard machine)

  • 강대임;송후근;이정태;안병덕;김창열;이재율;안병출;정광국;전영홍
    • 한국정밀공학회지
    • /
    • 제11권5호
    • /
    • pp.33-41
    • /
    • 1994
  • For the establishment of large force standard and the accurate measurement of large force, 2MN hydraulic force standard machine which consists of loading frame, deadweight machine, two ram/cylinder systems and hydraulic control system was designed and fabricated. Measurement results of shapes for tow ram/cylinders reveal that the ratio of effective area is 200.094. The relative deviation of force stability for the machine is about .+-. 0.01% at 2MN and is less than .+-. 0.005% below 2MN. This machine may be widely used to calibrate the force measuring devices in industry and to test the force sensors.

  • PDF

Parametric Study of Methanol Chemical Vapor Deposition Growth for Graphene

  • Cho, Hyunjin;Lee, Changhyup;Oh, In Seoup;Park, Sungchan;Kim, Hwan Chul;Kim, Myung Jong
    • Carbon letters
    • /
    • 제13권4호
    • /
    • pp.205-211
    • /
    • 2012
  • Methanol as a carbon source in chemical vapor deposition (CVD) graphene has an advantage over methane and hydrogen in that we can avoid optimizing an etching reagent condition. Since methanol itself can easily decompose into hydrocarbon and water (an etching reagent) at high temperatures [1], the pressure and the temperature of methanol are the only parameters we have to handle. In this study, synthetic conditions for highly crystalline and large area graphene have been optimized by adjusting pressure and temperature; the effect of each parameter was analyzed systematically by Raman, scanning electron microscope, transmission electron microscope, atomic force microscope, four-point-probe measurement, and UV-Vis. Defect density of graphene, represented by D/G ratio in Raman, decreased with increasing temperature and decreasing pressure; it negatively affected electrical conductivity. From our process and various analyses, methanol CVD growth for graphene has been found to be a safe, cheap, easy, and simple method to produce high quality, large area, and continuous graphene films.

반사경 측정을 위한 타워 방식의 Fold Mirror를 이용한 Fizeau 간섭계 시스템 구성 (A Study on the Tower type Fizeau Interferometer System with a Fold Minor for Measuring Large Optical Lens Profile)

  • 이응석;이기암;김옥현
    • 한국정밀공학회지
    • /
    • 제25권8호
    • /
    • pp.21-28
    • /
    • 2008
  • Fizeau interferometer is used for inspecting the lens surface profile accurately. This study is focused on the design and optical measuring techniques for large optical components, such as a reflection mirror for large area lithography or astronomical purpose. A tower type Fizeau interferometer is designed and set up in horizontally with a 45$^{\circ}$ fold mirror which makes easy to align the optical path of heavy interferometer system. To align the optical path, a five-axes stage for the interferometer is required. This study shows a method of the 45$^{\circ}$ fold mirror alignment by using a three-axis stage instead of adjusting the interferometer itself or measuring object. This system will be installed on the large optics polishing machine during the manufacturing process as an on-machine inspection system.

회절광학소자 제작을 위한 레이저 직접 노광기의 공정실험 (Parametric Study for a Diffraction Optics Fabrication by Using a Direct Laser Lithographic System)

  • 김영광;이혁교;김영식;이윤우
    • 한국정밀공학회지
    • /
    • 제33권10호
    • /
    • pp.845-850
    • /
    • 2016
  • A direct laser lithography system is widely used to fabricate various types of DOEs (Diffractive Optical Elements) including lenses made as CGH (Computer Generated Hologram). However, a parametric study that uniformly and precisely fabricates the diffractive patterns on a large area (up to $200mm{\times}200mm$) has not yet been reported. In this paper, four parameters (Focal Position Error, Intensity Variation of the Lithographic Beam, Patterning Speed, and Etching Time) were considered for stabilization of the direct laser lithography system, and the experimental results were presented.

간접접촉 심전도 측정에서의 오른발구동 접지의 효과와 한계 (The Effect and the Limitation of Driven-right-leg Ground on Indirect-contact ECG measurement)

  • 임용규
    • 대한의용생체공학회:의공학회지
    • /
    • 제39권2호
    • /
    • pp.103-108
    • /
    • 2018
  • This study reviews the common-mode noise model of indirect-contact ECG measurement which uses capacitive electrode and capacitive ground, and shows the reason of the large common-mode noise in indirect-contact ECG. And then, this study shows driven-right-leg ground in indirect-contact ECG measurement, and reviews how the driven-right-leg ground reduces the common-mode noise. This study then analyzes the relation between the effective area of the indirect-contact ground and the gain of the driven-right-leg circuit. This study introduces the output voltage saturation of the driven-right-leg circuit, which occurs frequently in indirect-contact ECG measurement with the condition of the high ground impedance. This study then shows the effect of the driven-right-leg circuit saturation on the common-mode noise.