• Title/Summary/Keyword: Large Scale System

Search Result 3,492, Processing Time 0.039 seconds

Policy for planned placement of sensor nodes in large scale wireless sensor network

  • Sharma, Vikrant;Patel, R.B;Bhadauria, HS;Prasad, D
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.7
    • /
    • pp.3213-3230
    • /
    • 2016
  • Sensor node (SN) is a crucial part in any remote monitoring system. It is a device designed to monitor the particular changes taking place in its environs. Wireless sensor network (WSN) is a system formed by the set of wirelessly connected SNs placed at different geographical locations within a target region. Precise placement of SNs is appreciated, as it affects the efficiency and effectiveness of any WSN. The manual placement of SNs is only feasible for small scale regions. The task of SN placement becomes tedious, when the size of a target region is extremely large and manually unreachable. In this research article, an automated mechanism for fast and precise deployment of SNs in a large scale target region has been proposed. It uses an assembly of rotating cannons to launch the SNs from a moving carrier helicopter. The entire system is synchronized such that the launched SNs accurately land on the pre-computed desired locations (DLs). Simulation results show that the proposed model offers a simple, time efficient and effective technique to place SNs in a large scale target region.

The Energy Performance Analysis of Large Scale Store Using Dynamic Thermal Analysis Simulation Program (동적열해석프로그램을 이용한 대형할인매장의 에너지 소비 특성 분석)

  • Kim, Byoung-Soo;Hong, Won-Pyo
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.6
    • /
    • pp.44-49
    • /
    • 2010
  • The purpose of this study is to analyze the situation of energy consumption and its characteristics in large scale store. The related survey is carried out in large scale store to investigate the energy consumption and energy use trend of heating, cooling, hot water, lighting, ventilation, equipments and others. The area of large scale discount store is about $65000m^2$, located in Daejeon. For Annual Energy Analysis of building, We surveyed used energy for 1 year and simulated using a building energy simulation(TRNSYS 16). The results of this study are as follows. 1)The amount of annual total energy consumption are 18615.244MWh/yr(286.4KWh/$m^2yr$), The rate of heating, cooling and base energy(for hot water, lighting, ventilation, equipments, cooking and others) is 3054MWh/yr(47kWh/$m^2yr$), 5660.09MWh/yr(87.08kWh/$m^2yr$), 9900.47MWh/yr(152.31KWh/$m^2yr$) respectively. The total used energy is higher than others building in Korea. Especially, The energy consumption of large scale store is very depends on operating period and pattern such as space temperature, occupancy, lighting system, equipments operating schedule and etc.

Multi-Central System for Large Scale PV Power Generation (대용량 태양광 발전용 멀티센트럴 시스템)

  • Park, Jong-Hyoung;Ko, Kwang-Soo;Kim, Heung-Geun;Nho, Eui-Cheol;Chun, Tae-Won
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.427-432
    • /
    • 2012
  • This paper proposes efficient operation method of PV system consisted of multi-central which is suitable for large scale system. The multi-central system used switch at a DC-link and applied proposed algorithm can improve the efficiency and the reliability on the existing system. This algorithm, with advantage of Multi-Central system can minimize the effect of different characteristic of each PV array due to a shadow or damaged PV cell. Each system is analysed and maximum power point tracking control, DC-link voltage control and output current control is used commonly. The validity is verified after comparing of the existing system and proposed system by simulation.

  • PDF

Decentralized energy market-based structural control

  • Lynch, Jerome Peter;Law, Kincho H.
    • Structural Engineering and Mechanics
    • /
    • v.17 no.3_4
    • /
    • pp.557-572
    • /
    • 2004
  • Control systems are used to limit structural lateral deflections during large external loads such as winds and earthquakes. Most recently, the semi-active control approach has grown in popularity due to inexpensive control devices that consume little power. As a result, recently designed control systems have employed many semi-active control devices for the control of a structure. In the future, it is envisioned that structural control systems will be large-scale systems defined by high actuation and sensor densities. Decentralized control approaches have been used to control large-scale systems that are too complex for a traditional centralized approach, such as linear quadratic regulation (LQR). This paper describes the derivation of energy market-based control (EMBC), a decentralized approach that models the structural control system as a competitive marketplace. The interaction of free-market buyers and sellers result in an optimal allocation of limited control system resources such as control energy. The Kajima-Shizuoka Building and a 20-story benchmark structure are selected as illustrative examples to be used for comparison of the EMBC and centralized LQR approaches.

Prospect of large scale Grain Drying, Storage and Milling Facility Complex in Korea (우리나라의 대규모 곡물 종합조제시설의 문제점 및 전망)

  • Kim, Tae Wook;Park, Kyung Kyoo
    • Current Research on Agriculture and Life Sciences
    • /
    • v.14
    • /
    • pp.37-47
    • /
    • 1996
  • The main objectives of this studies are to present the most desirable rice processing complex model system in a given our situations by comparision and analyzing the major factors and, also recommend the future prospect of the rice processing complex in Korea. There are 3 different rice processing complex models in Korea. Those are concrete bin, flat type steel bin and square bin. These systems have a lot of differences and have their own characteristics such as capital requirement, efficiency, storage capacity and quality controls. The major problems of the existing rice processing centers in Korea are high fixed cost and the unbalnced systems. Following is summary to solve this problems: 1. Development of the large scale harvester and high speed continuous dryer. 2. Quality inspective system of bulk grain and large scale temporary storage facilities. 3. Large size readjustment of arable land. 4. Select the convenient location of rice processing center and formulation of well equipment facilities.

  • PDF

Decentralized Adaptive Control for Nonlinear Systems with Time-Delayed Interconnections: Intelligent Approach (시간 지연 상호 연계를 가진 비선형 시스템의 분산 적응 제어: 지능적인 접근법)

  • Yoo, Sung-Jin;Park, Jin-Bae
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.4
    • /
    • pp.413-419
    • /
    • 2009
  • A decentralized adaptive control method is proposed for large-scale systems with unknown time-delayed nonlinear interconnections unmatched in control inputs. It is assumed that the time-delayed interaction terms are bounded by unknown nonlinear bounding functions. The nonlinear bounding functions and uncertain nonlinear functions of large-scale systems are compensated by the function approximation technique using neural networks. The dynamic surface control method is extended to design the proposed memoryless local controller for each subsystem of uncertain nonlinear large-scale time delay systems. Therefore, although the interconnected systems consist of a large number of subsystems, the proposed controller can be designed simply. We prove that all the signals in the total closed-loop system are semiglobally uniformly bounded and the control errors converge to an adjustable neighborhood of the origin. Finally, an example is given to demonstrate the effectiveness and applicability of the proposed scheme.

Charicteristics of Stationary and Transient Ground Impedance of Large-Scale Grounding Piles (임펄스 전류에 대한 대규모 접지시스템의 정상상태 및 과도상태의 접지임피던스 특성)

  • Lee, B.H.;Lee, S.C.;Park, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2296-2298
    • /
    • 1999
  • The stationary ground resistance and the transient ground impedance of grounding system are very important parameters in the field of lightning and surge protection. But, it is very difficult to obtain correct values of them in large-scale grounding system. In this paper, the stationary and transient ground impedances of a large-scale grounding system have been measured and analyzed under impulse currents. In order to obtain correct values of them, we have described Z-v(impedance vs ground potential rise) distributions and Z-t waveforms. The transient ground impedance of 36 [m] long three-parallel grounding piles have showed the inductive aspects and the hysterisis region under impulse currents.

  • PDF

Decentralized Sliding Mode Feedback Control Design Method for a Large Scale System with a Poly topic Models (폴리토픽 모델을 갖는 대규모 시스템을 위한 비집중화 슬라이딩 모드 제어기 설계)

  • Choi, Han-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.1
    • /
    • pp.1-4
    • /
    • 2010
  • Based on the sliding mode control theory, a decentralized controller design method is developed for a large scale system with a poly topic model. In terms of LMIs, we derive sufficient conditions for the existence of the decentralized controller guaranteeing a stable sliding motion. We also give an LMI-based control design algorithm. Finally, the proposed method is applied to decentralized stabilization of double-inverted pendulums. Simulation results show that our method gives not only the robust stability but perfect rejection of norm-bounded uncertainties.

An LMI-based Decentralized Sliding Mode Control Design Method for Large Scale Systems (대규모 시스템을 위한 LMI기반 비집중화 슬라이딩 모드 제어기 설계)

  • Choi, Han-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.11 no.8
    • /
    • pp.651-655
    • /
    • 2005
  • In this paper, we consider the problem of designing decentralized sliding mode control laws far a class of large scale systems with mismatched uncertainties. We derive a sufficient condition far the existence of a linear switching surface in terms of a linear matrix inequalities(LMIs), and we parameterize the linear switching surfaces in terms of the solution matrices to the given LMI existence conditions. We also give an algorithm for designing decentralized switching feedback control laws. Finally, we give a design example in order to show the effectiveness of our method.

Evolution of Large-Scale Filmless Full-PACS in Korea

  • Kim, Hee-Joung;Haijo Jung;Yoo, Hyung-Sik
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.28-31
    • /
    • 2002
  • Filmless full-PACS in korea has rapidly been growing, since government had supported collaborative PACS project between industry and university hospital in late of 1995. At the same time, a small company had started PACS business, while the Korea PACS society was being formed. In the beginning, PACS societies had focused on developing peripheral solutions such as DICOM gateway for image acquisition, x-ray film digitizer, and viewing software for research or management of personal image data, while Samsung Medical Center had started installing an imported partial PACS system which had recently upgraded with a new system. In similar time frame, a few hospitals had started developing and installing domestic large scale full-PACS system. Several years later, many hospitals have installed full-PACS system with national policy of reimbursement for PACS exams in November 1999. It is believed that Korea is the first country that adopted PACS reimbursement for filmless full-PACS as a national policy. Both experiences of full-PACS installation and national policy generated tremendous intellectual and technological expertise about PACS at all levels, clinical, hospital management, education, and industrial sectors. There are currently three types of PACS system which includes domestic, imported, and hybrid PACS system with imported solution for core system and domestic solution for peripheral system. There are more than 20 domestic PACS companies and they have now enough experiences so that they are capable of installing a truly full-PACS system for large-scale teaching hospitals. PACS societies in Korea understand how to design, implement, install, manage, sustain, and provide good services for large-scale full-PACS. PACS society has also strength for the highest integration technology of the Hospital Information. However, further understanding and timely implementation of continuously evolving international standard and integrated healthcare enterprise concepts may be necessary for international leading of PACS technologies for the future.

  • PDF