• Title/Summary/Keyword: Lamps

Search Result 1,057, Processing Time 0.023 seconds

Development of Dimming Ballast for T-5 Circular Fluorescent Lamps (환형 T-5램프용 복합 전자식 안정기 개발)

  • O, Cheol-Seong;Jo, Seong-Gwon;Lee, Hong-Ho;Yeo, Jin-Gi
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.871-874
    • /
    • 2003
  • The T-5 Lamps developed in 1996 is the high efficiency fluorescent lamps, the lamps voltage is high, and the lamps current small because the lamps are slender tube of 16mm diameter. And so, the electrical characteristics of the Ballast for the lamps are different from of the Ballast for T-10 or T-8 lamps. Therefore, the know-how of the exclusive Ballast for the T-5 fluorescent lamps should be as soon as possible. We described the electrical and optical characteristics of the Electronic Ballast for T-5 Circular Fluorescent lamps. The developed Electronic dimming Ballast for T-5 Circular Fluorescent lamps has the 45% energy saving effects than the T-10 lamps. And it has the promotion of the THD less than 10%, CF less than 1.5%, Flickering less than 5% and 99% power factor. And it is available for two T-5 Circular fluorescent Lamps dimming, 22W and 40W.

  • PDF

A Comparative Study on the Luminous Flux by Degree of Non-directional LED Lamps and Incandescent lamp (확산형 LED램프와 백열램프의 각도별 광속에 관한 비교연구)

  • Park, Chang-Yong;Seo, Jeong-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.8
    • /
    • pp.32-39
    • /
    • 2014
  • In general, non-directional LED lamps including high transmittance cover are more advantageous than directional LED lamps, which are efficient enough to improve luminous efficacy and obtain certification, allowing wide manufacture, sale, and distribution. Although KS C 7651(Self-ballasted LED lamps-Safety and performance requirements) was revised in July 2013, however, many companies are having a lot of difficulties in keeping the certification and product development for the lack of the photometric analysis for non-directional LED lamps. In this paper, through the measurement of the angular distribution of luminous flux of incandescent lamp and non-directional LED lamps, we examined the reasonability of non-directional LED lamps' standards as suggested in KS C 7651. According to the results, even if non-directional LED lamps satisfy KS C 7651, when compared to an incandescent lamp, they showed less diffusive than the incandescent lamp and the distribution of the luminous flux depending on the angle fluctuated greatly even among LED lamps. Judging by the result, the current standard of the non-directional LED lamps, KS C 7651, has been comprehended that the angular distribution of the luminous flux needs to be presented after being much more thoroughly standardized.

A Study on Visual Clarity According to Color Temperature and Color Rendering of Light Sources (각종 광원의 색온도, 연색성과 밝은 느낌에 대한 실험적 연구)

  • 이진우;지철근;조경애
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.1-6
    • /
    • 2003
  • We studied visual clarity according to the difference of color temperature and color rendering by using black and white printed paper and four sheets of colored paper under different kinds of lamps and same kind lamps. The results show visual clarity is proportioned to average color rendering index approximately except incandescent lamps and to color temperature under incandescent lamps, fluorescent lamps, high pressure sodium lamps, metal halide lamps and electrode less discharge lamps.

Light Enhancement Al2O3 Passivation in InGaN/GaN based Blue Light-emitting Diode Lamps

  • So Soon-Jin;Kim Kyeong-Min;Park Choon-Bae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.8
    • /
    • pp.775-779
    • /
    • 2006
  • In this study, sputtered $Al_2O_3$ thin films were evaluated as a passivation layer in the process of InGaN-based blue LEDs in order to improve the brightness of LED lamps. In terms of packaged LED lamps, lamps with $Al_2O_3$ passivation layer emanated higher brightness than those with $SiO_2$ passivation layer, and LED lamps with 90 nm $Al_2O_3$ passivation layer were the brightest among four kinds of lamps. Although lamps with $Al_2O_3$ passivation had a slight increase in operating voltage, their brightness was improved about 13.6 % compare to the lamps made of conventional LEDs without the changes of emitting wavelength.

A Study on the Optical Characteristics of LED Lamp as Alternative Type of FPL Lamp (FPL형광램프 대체형 LED램프의 조도특성에 관한 연구)

  • Ko, Jae-jun;Kim, Chung-hyeok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.10
    • /
    • pp.1-6
    • /
    • 2015
  • As lamps using LEDs are developed actively, also there have been large request for LED lamps that can replace traditional lamps like fluorescent lamps and metal halide lamps. But so far there are no proper standards that manufacturer can use and test their lamps. As a result of this, manufacturers are not only unable to develop LED lamps but also sell it even though they have technology. In this study, It is proposed that proper test method by investigating compatibility between all-type control gear and LED lamps by analyzing control gear for fluorescent lamp such as magnetic or electronic ballast that is currently used in the market.

Analysis of Spectral Light Intensity of High Pressure Sodium and Metal Halide Lamps for Plant Growth (식물생장용 고압나트륨램프와 메탈할라이드램프의 분광 광강도 분석)

  • Lee, Hye-In;Kim, Yong-Hyeon;Kim, Dong-Eok
    • Journal of Biosystems Engineering
    • /
    • v.35 no.6
    • /
    • pp.413-419
    • /
    • 2010
  • Plant growth was greatly affected by the spectral distribution and light intensity of artificial lighting sources. In this study, the spectral characteristics of high power sodium (HPS) lamps and metal halide (MH) lamps produced by three different manufacturers were measured. Even though the spectral distribution of HPS lamps with lamp wattage of 250 W and 400 W was very similar, but the spectral light intensity by the manufacturers was different. Difference in the spectral light intensity of MH lamps by the manufacturers was increased with the increasing lamps wattage. Light intensity at the region of blue (B), green (G), red (R) and far-red (FR) light of HPS and MH lamps was also analyzed. HPS lamps showed the light intensity in order of R, FR, B and G light. The ratio of G, B, R and FR to photosynthetic photon flux (PPF) of HPS lamps with the lamp wattage of 250 W was 3.0-3.2%, 5.5-5.9%, 17.3-19.2% and 6.5-7.8%, respectively. For MH lamps, it showed the light intensity in order of R, FR, B, and G. The ratio of B, G, R, and FR to PPF of MH lamps with 250 W was 14.0-15.5%, 22.6-27.5%, 7.5-9.5% and 2.7-4.2%, respectively. HPS and MH lamps with 400 W had a relatively smaller ratio of R and FR to PPF than those with 250 W. HPS lamps showed that the ratio of light intensity of B and FR to R was 0.15-0.28 and 0.36-0.4, respectively. For MH lamps, the ratio of light intensity of B and FR to R was 1.26-2.72 and 0.27-0.56, respectively. From these results, it was concluded that the portion of blue light of MH lamps was higher than those of HPS lamps.

Development of Electronic Ballast for 110Watt lamps (110Watt 4등용 형광등 안정기 개발)

  • 한재현;조계현;박종연
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2927-2930
    • /
    • 2003
  • This paper has been studied the ballast for multiple lamps. Many fluorescent lamps are demanded in where industrial buildings and public buildings. Using the proposed ballast for multiple lamps, we can decrease the cost and the space for installing. Also in the paper, the protection circuit is introduced for over voltage and current. The general problem of the ballast for multiple lamps is to shut down the ballast circuit in the ease of one abnormal lamp. But the proposed method is not shut down all the circuit even if one lamp is in an abnormal condition.

  • PDF

A Review on Fluorescent Lamps Having Noncircular Cross-sections

  • Ko, Jae-Hyeon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1165-1168
    • /
    • 2005
  • We review discharge characteristics of fluorescent lamps having noncircular cross sections. The developmental and theoretical history of noncircular cross-section lamps is summarized chronologically. In particular, discharge characteristics of noncircular cross-section lamps will be summarized and analyzed including plasma contraction, electron temperature, and ambipolar diffusion loss, which might give us some insights into the way to develop more efficient and uniform flat fluorescent lamps, which have recently arisen as a new light source of large-size backlight units for LCD TV applications.

  • PDF

Implementation of Failure Detecting and Monitoring System for High-Pressure Natrium Lamps and Ballasts (고압나트륨 램프와 안정기를 위한 고장 감시 시스템의 실현)

  • 오우석;이휘재;김규식;배희환
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.81-84
    • /
    • 1998
  • In this paper, we implemented this failure detecting and monitoring system for high-pressure natrium lamps and ballasts. The hall CTs of the local detecting system measure the current flowing into natrium lamps via ballasts and acertain whether the natrium lamps or ballasts are out of order or not. These test data are transmitted to the main monitoring system. So, we can see the status of the natrium lamps or ballasts promptly.

  • PDF

Phototaxis of Fish - Response of Sea-bass to the Attracting Lamp - (어류의 주광성에 관한 연구 - 유도등에 대한 농성어의 반응 -)

  • 양용림
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.24 no.4
    • /
    • pp.158-163
    • /
    • 1988
  • The author has examined how sea-bass, Epinephelus septemfasciatus respond to surface attracting lamps line and underwater attracting lamps line in the experimental water tank (550L$\times$58W$\times$73H cm). The attracting rate was investigated in accordance with the intervals of lighting and putting out hour (1, 5 minute) when each of the attracting lamps was gradually switched off after they were switched on all at once. The results are as follows: 1. Distribution of fish at the illuminated section; (1). The fish was more distributed in the section adjacent to the extinguished section. (2). Difference of distribution between section and section and section was greater at surface attracting lamps as compared with underwater attracting lamps. (3). Surface attracting lamps was more distributed than underwater attracting lamps at intervals of 5 minutes. 2. Attracting rate of the last section; (1). The rate was showed increasing as illuminating time elapse and became L type. (2). Attracting rate in underwater attracting lamps was higher than surface attracting lamps at intervals of 1 minutes and lower than surface attracting lamps at intervals of 5 minuets.

  • PDF