• 제목/요약/키워드: Laboratory safety & health

Search Result 471, Processing Time 0.031 seconds

Research Centered on D College Perception Survey of Students on Radiation (D대학을 중심으로 한 학생들의 방사선 인식 조사)

  • Hong, Seung-Bok;Yang, Eun-Ju;Kim, Young-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.397-403
    • /
    • 2020
  • This survey was willing to suggest the basic data required for strategic planning to improve the recognition rate on radiation by investigating the difference between the college students who major in radiology and who don't about using radiation. As the results of questionnaire survey on 'knowledge, degree of self-consciousness, danger, convenience and management' targeting 441 students who belonged to D college, 75% of them answered that radiation exists in their daily lives and 54% of them answered they did not know about radiation well. It showed that radiation is dangerous no matter how much the amount is (56%) and it is not dangerous if it is managed well (81%). They answered that they enjoy the convenience of radiation (82%) and the use for medical purpose took the highest percentage among them (58%). It showed that it is important to manage the radiation and should be controlled by the government in institutional way than the individual (64%). The negative answer to the question of 'do you trust the government?' was dominant (75% below average). As the results of this survey, it was recognized that both of them who major in radiology or not were aware of positive aspect of radiation (especially medical technology field) well and the improving the perception of radiation led by the government and definite restriction on its safety should be preceded for safe use.

Analysis Method of N-Nitrosamines in Human Urine by LC-MS/MS System (LC-MS/MS 시스템을 이용한 소변 중 N-니트로사민류 분석법 확립)

  • Park, Na-Youn;Jung, Woong;Kho, Younglim
    • Journal of the Korean Chemical Society
    • /
    • v.61 no.2
    • /
    • pp.51-56
    • /
    • 2017
  • N-nitrosamines are the nitroso compounds which are produced by nitrosation reactions of the secondary amine and nitrite under acidic conditions. Approximately 300 species of N-nitrosamine have been tested for carcinogenicity in laboratory experiments, with 90% of them demonstrated carcinogenic effects different animal species, including higher primates. In 1978, IARC classified NDMA and NDEA as Group 2A, and NDPA, NDBA, NPIP, NPYR and NMOR as Group 2B. In this study, we established pretreatment and analytical method for N-nitrosamines (NDMA, NDEA, NMEA, NDPA, NDBA, NPIP, NPYR and NMOR) in human urine for biological monitoring of N-nitrosamines. The analytes were extracted using solid phase extraction (SPE), then quantitative analysis was performed by LC-(APCI)-MS/MS. The accuracies of the established method were between 85.8~108.7% and precisions were lower than 20%. The limit of detection (LOD) were between 0.0002 (NDBA) and 0.0793 (NDMA) ng/ml. The linearity obtained was satisfying for the 8 N-nitrosamines, with a coefficient of determination ($r^2$) higher than 0.999. The mean concentrations of N-nitrosamines in the urine were 2.645 mg/g creatinine for NDMA, 0.067 mg/g creatinine for NDEA, 0.009 mg/g creatinine for NMEA, 0.011 mg/g creatinine for NDBA, 0.271 mg/g creatinine for NPIP and 0.413 mg/g creatinine for NPYR. NDPA and NMOR were not detected. It can be used as a instrumental methodology for evaluation and risk assessment of human exposure to N-nitrosamines for the further research.

Acute Oral Toxicity and Skin Irritation Studies on Lamia-Kill$^{(R)}$ Composed of Benzalkonium Chloride and Citric Acid (염화벤지코늄과 구연산을 주성분으로 하는 살균 소독제 라미아-킬에 대한 급성경구독성 및 피부자극성 시험에 관한 연구)

  • Cha, Chun-Nam;Lee, Yeo-Eun;Son, Song-Ee;Yoo, Chang-Yeol;Park, Eun-Kee;Choi, Hyun-Ju;Kim, Suk;Lee, Hu-Jang
    • Journal of Food Hygiene and Safety
    • /
    • v.26 no.4
    • /
    • pp.377-382
    • /
    • 2011
  • This test was performed to evaluate the acute oral toxicity and skin irritation of Lamia-Kill$^{(R)}$, disinfectant, containing 20% benzalkonium chloride and 10% citric acid. In acute oral toxicity, Lamia-Kill$^{(R)}$ was orally administered at dose levels of 2,000, 1,000, 500, 250 and 0 mg/kg body weight. After single oral administration to both sexes of SD rats, the rats were observed for 14 days. In primary skin irritation test, New Zealand white rabbits were dermally treated with Lamia-Kill$^{(R)}$ for 24 hr and observed for 3 days. All rats treated with Lamia-Kill$^{(R)}$ were induced no toxic signs in mortalities, clinical findings, body weights and gross findings. Also, the disinfectant did not induce any adverse reactions such as erythema and edema on intact skin sites for the most part rabbits, but on abraded skin sites, some rabbits showed very slight erythema on 24 hr after topical application. With the results of this study, Lamia-Kill$^{(R)}$ have no effect on acute toxicity and side effect in SD rats and was classified as a practically non-irritating material based on the score 0.50 of primary irritation index.

Bacterial Contamination in Disposable Wet Wipes in General Restaurants 2nd (대중음식점 일회용 물티슈의 세균 오염도 조사(2))

  • Chong, Moo-Sang
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.54 no.1
    • /
    • pp.23-27
    • /
    • 2022
  • Disposable wet wipes provided by general restaurants in the Jeju Special Self-Governing Province were evaluated for compliance with the labeling requirements and the degree of bacterial contamination set by the Ministry of Food and Drug Safety. Of the 32 types of disposable wipes, five types of disposable wipes did not indicate the name and location of the business office of the manufacturer. Only 12 types of wet wipes were marked with the date of manufacture and expiration date. Bacterial contamination was seen in 9 types of wet wipes through bacterial culture but these were absent in the remaining 23 types (71.9%). The results of the antimicrobial susceptibility test for the 9 identified strains showed no methicillin-resistant coagulase-negative staphylococci (MRCNS) or multidrug-resistant bacteria. Through this study, it is recommended that the date of manufacture and expiration date must be indicated on the surface of disposable wet wipes designated as hygiene products, and clean uncontaminated wet wipes must comply with storage standards. In addition, the results are expected to contribute to the enhancement and improvement of hygiene management supervision, personal hygiene management, and an improvement in national health.

Assessment of dust exposure and personal protective equipment among dental technicians (치과기공사의 분진노출 수준 및 개인보호구 착용 실태 - 대구지역을 중심으로 -)

  • Park, Soo-Chul;Jeon, Man-Joong;SaKong, Joon
    • Journal of Technologic Dentistry
    • /
    • v.33 no.1
    • /
    • pp.93-102
    • /
    • 2011
  • Purpose: The study aimed to evaluate working environment for dental technician by measuring dust level, ventilation conditions and the use of personal protective equipment and to provide basic information required to improve working environment and develop health education programs for dental technician. Methods: A total of 240 dental technician who are registered with the Daegu Association of Dental technician and working at 34 dental laboratories participated in the study. And the dust level was measured at 21 different spots in 16 dental laboratories out of 34. Results: Of 34 dental laboratories, 31 (91.2%) were equipped with a ventilator, but the remaining 3 (8.8%) did not have a ventilator. By the number of ventilator, 1 to 3 ventilators were found in 22 dental laboratories (71.0%), 4 to 6 ventilators were in 7 laboratories (22.5%) and more than 7 ventilators in 2 laboratories(6.5%). According to the frequence of changing filters in dust collector, 20 dental laboratories (58.9%) changed filters every four weeks, 10 laboratories (29.4%) changed them every six weeks and 4 laboratories (11.7%) changed them every eight weeks. Of total respondents, 114 (61.3%) said they wore a mask all the time while working, 56 (29.6%) said they frequently wore a mask, 19 (10.1%) said they did not wear a mask. As for the type of masks, 159 (84.1%) used a disposable mask, 25 (13.2%) used a cotton mask and 5 (2.7%) used an anti-dust mask. For dust sat on their outfits while working, 102 (54.0%) shook their uniforms inside workplace to keep dust off the uniforms, 64 (33.9%) did not anything until they wash their uniforms and 23 (12.1%) shook their uniforms outside workplace to keep dust off the uniforms. Of total respondents, 182 (96.3%) had a particle in their eyes while carrying out grinding work. Based on the measurement of floating dust at workplace, 3 dental laboratories showed dust concentration exceeding the minimum level of 10 mg/$m^3$ allowed under the permit for environment. Of those, 1 laboratory had the dust concentration that was more than 1.5 times higher than the minimum level. Dust concentration was higher in laboratories that used a dust collector with 0.5 horse power and changed filters more than 3 weeks ago. Dust comprised of nickel (more than 70%), chrome (9%) and others. The mean chrome concentration was more than twice higher than the minimum permissible level of 0.5 mg/$m^3$. There were two laboratories that showed chrome concentration exceeding the level of 0.4 mg/$m^3$. Like dust concentration, chrome level was higher in laboratories that used a dust collector with 0.5 horse power and changed filters more than 3 weeks ago. There were six laboratories that had nickel concentration exceeding the minimum permissible level of 1 mg/$m^3$. Of those, one laboratory had nickel concentration that was more than three times higher than the minimum permissible level. Nickel concentration was also higher in laboratories that used a dust collector with 0.5 horse power and changed filters more than 3 weeks ago. Conclusion: It is not likely that heavy metal concentrations found in the study constitute respiratory dust. It is however necessary for health of dental technician to apply the Industrial Safety and Healthy Law to dental laboratories and make recommendations for the use of personal protective equipment, installation of a proper number of ventilators, more frequent change of filters in dust collector and improved ventilation for polishing work. At the same time, dental technician need education on how to use personal protective equipment and how to efficiently remove dust from their uniforms.

Oestrogenic Activity of Parabens in Uterotrophic Assay (자궁비대시험 연구에서 에틸, 프로필, 이소프로필, 부틸, 이소부틸 파라벤의 내분비독성)

  • Jo Eun-Hye;Jung Ji-Youn;Park Cheol-Beom;Park Sun-Hee;Shim Yhong-Hee;Kang Dae-Hyuck;Lee Sung-Ho;Yu Jong-Hoon;Kim Sun-Jung;Lee Sung-Hoon;Park Jung-Ran;Lee Yong-Soon;Kang Kyung-Sun
    • Journal of Food Hygiene and Safety
    • /
    • v.21 no.2
    • /
    • pp.118-128
    • /
    • 2006
  • This study was conducted to determination of the endocrine distruptor function of 'Parabens' by dosing ethyl paraben, propyl paraben, isopropyl paraben, butyl paraben and isobutyl paraben to the immature SD rats. 18 groups were given vehicle control group, negative control group (Dibutyl phthalate), postive control group ($1'7-{\alpha}$ Ethynylestrdiol) and each paraben groups involved 3 dose level. Rats were injected with 62.5, 250 and 1,000mg/kg from postnatal day 19 till 21 once a day in subcutaneous and a total 3, times. There was no treatment related death. but, subcutaneous nodule, edema, alopecia and scrub formation on injection site was observed. These signs was become worse in high dose level. these signs was cause from physical stimulation by test substance which parabens were mix with com oil as vehicle. In the analysis of organ weights, absolute and relative weights of brain, spleen, liver, thymus, heart, kidneys, adrenals, ovaries and vagina were no difference with control group. but, wet and blotted weight of uterus was increased in every high dose parabens treat group. Especially, all dose level of isobutyl paraben was showed increment of uterus weight. uterus dilatation of parabens treated group was observed in gross anatomic pathology and these result was agree with wet and blotted weight of uterus. In the result of this study, estrogenic effect as endocrine distruptor was observed in ethyl paraben, propyl paraben, isopropyl paraben, butyl paraben and isobutyl paraben. and it was considered isobutyl paraben has highest estrogrnic effect under the condition of this study.

Immune response and efficacy of pigeon pox virus vaccine and fowl pox virus vaccine in chickens

  • Shil, Niraj Kanti;Rahman, Md Siddique;Hossain, M.T.;Islam, M.T.;Rahman, M.M.;Islam, K.B.M. Saiful;Cha, Se-Yeoun;Jang, Hyung-Kwan;Song, Hee-Jong
    • Korean Journal of Veterinary Service
    • /
    • v.30 no.4
    • /
    • pp.497-503
    • /
    • 2007
  • The humoral immune response of chicken vaccinated with fowl and pigeon pox virus vaccines was determined with the protective potentiality of the two vaccines in field condition of Bangladesh. Different aged Fayoumi chicks were subjected for the study. To assess the relationship with better immune response among experimental groups, the average percentage of 'take reaction' was examined and recorded to 97.77% in group A, 93.33% in group B and 100.0% in group C. The level of immune status induced by different vaccinated group was measured by passive hemagglutination (PHA) microplate test method. The mean PHA titer levels after primary vaccination were $33.06{\pm}14.13$ in group A, $32.0{\pm}14.81$ in group B, and $33.0{\pm}13.66$ in group C. Following booster vaccination, the mean PHA titer levels in prior of challenge were increased to $55.46{\pm}14.64$ in groups A and C, and $46.93{\pm}16.52$ in group B. The recorded PHA titer levels of each group at two weeks after challenge were significantly increased to $106.66{\pm}31.22$, $93.86{\pm}33.04$ and $110.93{\pm}29.29$, respectively. The PHA titer levels after vaccination and challenge were significantly increased compared to pre-vaccination titer levels (P<0.01). Although the PHA titer levels among three groups administrated different vaccine combinations in prior of challenge were significantly varied (P<0.01), it was observed that all of the vaccinated chicks were highly protected against challenge infection.

Culture of Rat Embryos During Early Organogenesis (초기 기관형성기중 랫트배자의 배양에 관한 연구)

  • Chin Kang;Lee, You-Mie;Rheu, Hang-Mook
    • Environmental Analysis Health and Toxicology
    • /
    • v.6 no.1_2
    • /
    • pp.71-82
    • /
    • 1991
  • Rat embryos were cultured out of the mother from the head-fold stages, 9.5 days to 11.5 days during which they start to develop the brain, eyes, ears and cardiovascular system etc. We principally did the basic experiment in order to establish the best condition of the rat whole embryo culture in our laboratory. The temperature in the culture system was maintained 37$^{\circ}C$$\pm$0.2$^{\circ}C$ for 48 hrs. The culture was carried out in humidified atmosphere of the air, intially, the bottles were equilibrated with 5% $O_2$,5% $CO_2$, and 90% $N_2$gas mixture. After 22 or 24 and 29 or 30 hrs the cultures were reequilibrated with 20% $O_2$, 5% $CO_2$,75% $N_2$and 40% $O_2$, 5% $CO_2$, 55%$N_2$respectively. Various types of sera were tested and for the purpose of minimizing the quantity of rat serum, artificial medium was also tried and it was determined that rat serum supported normal growth over a period of 48 hrs, based on total growth analysis and structural comparisons with in vivo specimens.

  • PDF

Determination and Validation of Synthetic Antioxidants in Processed Foods Distributed in Korea

  • Park, Hyeon-Ju;Seo, Eunbin;Park, Jin-Wook;Yun, Choong-In;Kim, Young-Jun
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.5
    • /
    • pp.297-305
    • /
    • 2022
  • Antioxidants are food additives that extend the shelf life of food products by preventing lipid rancidity caused by active oxygen. They can either be naturally-derived or manufactured synthetically via chemical synthesis. In this study, method validation of five synthetic antioxidants, namely butylated hydroxyanisole, butylated hydroxytoluene, tertiary butylhydroquinone, propyl gallate, and disodium ethylenediaminetetraacetic acid, was performed using a high performance liquid chromatography-ultraviolet visible detector, and the method applicability was evaluated by analyzing foods containing antioxidants. The coefficient of determination (R2) average was 0.9997, while the limit of detection and limit of quantification were 0.02-0.53 and 0.07-1.61 mg/kg, respectively. The intra and inter-day accuracies and precisions were 83.2±0.7%-98.7±2.1% and 0.1%-5.7% RSD, respectively. Inter-laboratory validation for accuracy and precision was conducted using the Food Analysis Performance Assessment Scheme quality control material. The results satisfied the guidelines presented by the AOAC International. In addition, the expanded uncertainty was less than 16%, as recommended by CODEX. Consequently, to enhance public health safety, the results of this study can be used as basis data for evaluating the intake of synthetic antioxidants and assessing their risks in Korea.

Optical Fiber-Based Hybrid Nerve Measurement System for Static and Dynamic Behavior of Structures (구조물의 정적 및 동적 거동 모니터링을 위한 광섬유 기반 하이브리드 신경망 계측 시스템)

  • Park, Young-Soo;Song, Kwang-Yong;Jin, Seung-Seop;Park, Young-Hwan;Kim, Sung-Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.2
    • /
    • pp.33-40
    • /
    • 2020
  • Various studies have been conducted on the structural health monitoring using optical fiber. Optical fibers can be used to measure multiple and distributed strain. Among the optical fiber sensors, FBG sensor has advantages of dynamic response measurement and high precision, but the number of measurement points is limited. Distributed fiber sensors, represented by distributed Brillouin sensors, usually have more than 1000 measurement points, but the low sampling rate makes dynamic measurements impossible. In this study, a hybrid nerve sensor system using only the advantages of the FBG sensor and the distributed Brillouin sensor has been proposed. Laboratory experiments were performed to verify the proposed system, and the accuracy and reproducibility were verified by comparing with commercial sensors. Applying the proposed system, dynamic response ambient measurements are used to evaluate the global state of the structure. When an abnormal condition is detected, the local condition of the structure is evaluated by static response measurement using the distributed measurement system. The proposed system can be used for efficient structural health monitoring.