Study and Design of L-C-L Filter for Single-Phase Grid-Connected PV Inverter (단상 계통연계 태양광 인버터용 L-C-L 필터 설계 및 분석)

  • Cha, Han-Ju;Vu, Trung-Kien
    • Proceedings of the KIEE Conference
    • /
    • 2009.04b
    • /
    • pp.228-230
    • /
    • 2009
  • Nowadays, the LCL-filter type becomes an attractive grid interfacing for grid-connected Voltage Source Inverter (VSI). LCL-filter can render the current harmonics attenuation around the switching frequency by using smaller inductance than L-filter. This paper presents a study about the LCL-filter design for single-phase grid-connected inverter in Photovoltaic (PV) system. According to the expected current ripple, the inductances of the filter can be determined. Based on the absorbed reactive power on capacitor, the capacitance can be calculated. Due to the theoretical analysis, a LCL-filter based single phase grid connected inverter control system are simulated. The studied simulation results are given to validate the theoretical analysis.

  • PDF

LCL Filter Design Method for Grid-Connected PWM-VSC

  • Majic, Goran;Despalatovic, Marin;Terzic, Bozo
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.5
    • /
    • pp.1945-1954
    • /
    • 2017
  • In recent years, several LCL filter design methods for different converter topologies have been published, many of which use analytical expressions to calculate the ideal converter AC voltage harmonic spectrum. This paper presents the LCL filter design methodology but the focus is on presentation and validation of the non-iterative filter design method for a grid-connected three-phase two-level PWM-VSC. The developed method can be adapted for different converter topologies and PWM algorithms. Furthermore, as a starting point for the design procedure, only the range of PWM carrier frequencies is required instead of an exact value. System nonlinearities, usually omitted from analysis have a significant influence on VSC AC voltage harmonic spectrum. In order to achieve better accuracy of the proposed procedure, the system nonlinear model is incorporated into the method. Optimal filter parameters are determined using the novel cost function based on higher frequency losses of the filter. An example of LCL filter design for a 40 kVA grid-connected PWM-VSC has been presented. Obtained results have been used to construct the corresponding laboratory setup and measurements have been performed to verify the proposed method.

Co-design of the LCL Filter and Control for Grid-Connected Inverters

  • Zhang, Yu;Xue, Mingyu;Li, Minying;Kang, Yong;Guerrero, Josep M.
    • Journal of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.1047-1056
    • /
    • 2014
  • In most grid-connected inverters (GCI) with an LCL filter, since the design of both the LCL filter and the controller is done separately, considerable tuning efforts have to be exerted when compared to inverters using an L filter. Consequently, an integrated co-design of the filter and the controller for an LCL-type GCI is proposed in this paper. The control strategy includes only a PI current controller and a proportional grid voltage feed-forward controller. The capacitor is removed from the LCL filer and the design procedure starts from an L-type GCI with a PI current controller. After the PI controller has been settled, the capacitor is added back to the filter. Hence, it introduces a resonance frequency, which is identified based on the crossover frequencies to accommodate the preset PI controller. Using the proposed co-design method, harmonic standards are satisfied and other practical constraints are met. Furthermore, the grid voltage feed-forward control can bring an inherent damping characteristic. In such a way, the good control performance offered by the original L-type GCI and the sharp harmonic attenuation offered by the latter designed LCL filter can be well integrated. Moreover, only the grid current and grid voltage are sensed. Simulation and experimental results verify the feasibility of the proposed design methodology.

An active damping method of a grid connected LCL-filter using a notch filter (노치필터를 이용한 계통연계 LCL필터의 능동 댐핑 방법)

  • Kang, Yikyu
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.155-156
    • /
    • 2014
  • 본 논문은 계통연계 목적으로 사용하는 LCL필터의 공진현상을 억제하기 위한 간단한 능동 댐핑 원리와 방법을 보인다. LCL필터는 기존의 1차 필터인 L필터에 비해 적은 동량으로 효과적인 출력파형의 고조파 저감 효과를 갖지만, LC파트 추가로 인해 허수축에 공진복소극이 존재하여 필연적으로 시스템에 공진이 발생하게 된다. 본 논문에서는 추가적인 센서나 수동소자의 사용 없이 LCL필터의 공진복소극을 상쇄하는 노치필터를 제어기에 적용하여 시스템의 안정성을 확보한다. 시뮬레이션을 수행하여 타당성을 입증한다.

  • PDF

Novel Control and Design Method for Wide Stability Range of Grid Connected Inverter with LCL Filter (LCL 필터를 사용하는 계통 연계형 인버터의 넓은 안정 영역을 갖는 새로운 제어 및 설계 기법)

  • Park, Kwon-Sik;Seo, Byung-Jun;Kim, Hak-Soo;Nho, Eui-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.6
    • /
    • pp.440-445
    • /
    • 2018
  • This study proposes a novel control and design method for a grid-connected inverter with an LCL filter without damping. The current resonance phenomenon must be considered when designing the grid-connected inverter system with an LCL filter. Passive or active damping is used in the inverter system to reduce the resonant current. However, passive damping reduces the efficiency of the system, and active damping methods are complex. If the resonant frequency is in a specific region, then the system will be unstable. This study examines the process of stabilizing the entire region without resonant damping. The validity of the proposed method is verified through simulation and experimentation.

Analysis of Current Control Stability using PI Control in Synchronous Reference Frame for Grid-Connected Inverter with LCL Filter (LCL 필터를 사용하는 계통연계형 인버터의 동기좌표계 PI 전류제어 안정도 해석)

  • Jo, Jongmin;Lee, Taejin;Yun, Donghyun;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.2
    • /
    • pp.168-174
    • /
    • 2016
  • In this paper, current control using PI controller in the synchronous reference frame is analyzed through the relationship among bandwidth, resonance frequency, and sampling frequency in the grid-connected inverter with LCL filter. Stability is investigated by using bode plot in frequency domain and root locus in discrete domain. The feedback variable is the grid current, which is regulated by the PI controller in the synchronous reference frame. System delay is modeled as 1.5Ts, which contains computational and PWM modulator delay. Two resonance frequencies are given at 815 Hz and 3.16 kHz from LCL filter parameters. Sufficient phase and gain margins can be obtained to guarantee stable current control, in case that resonance frequency is above one-sixth of the sampling frequency. Unstable current control is performed when resonance frequency is below one-sixth of the sampling frequency. Analysis results of stability from frequency response and discrete response is the same regardless of resonance frequency. Finally, stability of current control based on theoretical analysis is clearly verified through simulation and experiment in grid-connected inverters with LCL filter.

Design of AC Input LCL Filter for Voltage Source PWM Converter (전압형 PWM 컨버터의 교류입력측 LCL필터 설계)

  • Noh, Jae-Seok;Choi, Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.506-509
    • /
    • 2002
  • In this paper, a design method of LCL filter at the AC input side of a voltage source PWM converter is proposed. Effective method to prevent pollution of the utility caused by high frequency current ripple is to use a LCL filter instead of the L filter The C elements in the filter provide a low impedance path for the high frequency component, preventing them from entering the utility. A resistor in series with a capacitor is used for damping the resonance in the filter. The design examples are shown and the validity of the proposed design method is verified through the PSIM simulation.

  • PDF

Application of a C-Type Filter Based LCFL Output Filter to Shunt Active Power Filters

  • Liu, Cong;Dai, Ke;Duan, Kewei;Kang, Yong
    • Journal of Power Electronics
    • /
    • v.13 no.6
    • /
    • pp.1058-1069
    • /
    • 2013
  • This paper proposes and designs a new output filter called an LCFL filter for application to three phase three wire shunt active power filters (SAPF). This LCFL filter is derived from a traditional LCL filter by replacing its capacitor with a C-type filter, and then constructing an L-C-type Filter-L (LCFL) topology. The LCFL filter can provide better switching ripple attenuation capability than traditional passive damped LCL filters. The LC branch series resonant frequency of the LCFL filter is set at the switching frequency, which can bypass most of the switching harmonic current generated by a SAPF converter. As a result, the power losses in the damping resistor of the LCFL filter can be reduced when compared to traditional passive damped LCL filters. The principle and parameter design of the LCFL filter are presented in this paper, as well as a comparison to traditional passive damped LCL filters. Simulation and experimental results are presented to validate the theoretical analyses and effectiveness of the LCFL filter.

Design of LCL Filter through Inductor Optimization Method in Grid-Connected Inverter (계통연계 인버터의 인덕터 최적화 기법을 통한 LCL 필터 설계)

  • Jang, Jae-Ha;Kim, Kyeong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.11
    • /
    • pp.58-67
    • /
    • 2014
  • A grid-connected inverter used for renewable energy resources produces harmonic components in the switching frequency. To effectively reduce switching harmonic components, several types of filter are generally used in the output stage of the grid-connected inverter. Many research works on LCL filter design have been done to maintain the performance with low cost. However, it is not easy to make the filter design be economical and optimal due to the varying characteristic of magnetic core and redundancy design by experience. In this paper, a design method for a LCL filter is presented through the inductor optimization scheme in view of the size and cost when the inductor is manufactured using the magnetic core. The effectiveness is verified through tests using a 3kW grid-connected inverter by simulations and experiments.

Analysis and Design of LCL Filter with Passive Damping Circuits for Three-phase Grid-connected Inverters

  • Ahn, Hyo Min;Oh, Chang-Yeol;Sung, Won-Yong;Ahn, Jung-Hoon;Lee, Byoung Kuk
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.217-224
    • /
    • 2017
  • The analysis and design process of the LCL filter with passive damping circuits for three-phase grid-connected inverter are presented based on the generalized model of LCL filter. Several types of the passive damping circuits in previous studies could be compared and analyzed by using the generalized model considering various design criteria of passive damping circuits. According to the analysis in this paper, a reasonable configuration of passive damping circuits for three-phase grid-connected inverters is proposed. The validity of the proposed design process is verified by informative simulation and experimental results.