• 제목/요약/키워드: LC-MS

검색결과 1,326건 처리시간 0.031초

Analysis of Carbonyl Compounds using DNPH Cartridge with LC-MS (DNPH cartridge/LC-MS 방법에 의한 카르보닐화합물 분석에 관한 연구)

  • Cho Deok-Hee;Song Il-Seok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제22권2호
    • /
    • pp.201-208
    • /
    • 2006
  • Several carbonyl compounds are important because of their irritant and toxic properties, mutagenicity and carcinogenicity. Therefore, they are regulated in korean odor emission standard. In this study, atmospheric pressure ionization-mass spectrometry(API-MS) is used for the analysis of carbonyl compounds after derivatization with 2, 4-dinitrophenylhydrazine (DNPH) and liquid chromatographic separation. In the negative ion mode, the $[M-H]^-$ pseudomolecular ions are most abundant for the carbonyls. Analytical parameters such as linearity, repeatability and minimum detection limit were evaluated. The linearities ($r^2$) for carbonyls were $0.9977{\sim}0.9999$ when analyte concentration ranges from $25\;to\;250{\mu}g/L$(n=6). The relative standard deviations (%RSD) for carbonyls were $0.55{\sim}3.51%$ for concentration of $100{\mu}g/L$(n=5). The minimum detection limit (MDL) was $1.88{\mu}g/L$(0.27 ppb) for i-valeraldehyde. It was shown that LC-MS method has a great potential for carbonyl compounds analysis.

Evaluation of Recent Data Processing Strategies on Q-TOF LC/MS Based Untargeted Metabolomics

  • Kaplan, Ozan;Celebier, Mustafa
    • Mass Spectrometry Letters
    • /
    • 제11권1호
    • /
    • pp.1-5
    • /
    • 2020
  • In this study, some of the recently reported data processing strategies were evaluated and modified based on their capabilities and a brief workflow for data mining was redefined for Q-TOF LC-MS based untargeted metabolomics. Commercial pooled human plasma samples were used for this purpose. An ultrafiltration procedure was applied on sample preparation. Sample set was analyzed through Q-TOF LC/MS. A C18 column (Agilent Zorbax 1.8 µM, 50 × 2.1 mm) was used for chromatographic separation. Raw chromatograms were processed using XCMS - R programming language edition and Isotopologue Parameter Optimization (IPO) was used to optimize XCMS parameters. The raw XCMS table was processed using MS Excel to find reliable and reproducible peaks. Totally 1650 reliable and reproducible potential metabolite peaks were found based on the data processing procedures given in this paper. The redefined dataset was upload into MetaboAnalyst platform and the identified metabolites were matched with 86 metabolic pathways. Thus, two list were obtained and presented in this study as supplement files. The first list is to present the retention times and m/z values of detected metabolite peaks. The second list is the metabolic pathways related with the identified metabolites. The briefly described data processing strategies and dataset presented in this study could be beneficial for the researchers working on untargeted metabolomics for processing their data and validating their results.

Mass Spectrometry-Based Analytical Methods of Amatoxins in Biological Fluids to Monitor Amatoxin-Induced Mushroom Poisoning

  • Choi, Jin-Sung;Lee, Hye Suk
    • Mass Spectrometry Letters
    • /
    • 제13권4호
    • /
    • pp.95-105
    • /
    • 2022
  • Amatoxin-induced mushroom poisoning starts with nonspecific symptoms of toxicity but hepatic damage may follow, resulting in the rapid development of liver insufficiency and, ultimately, coma and death. Accurate detection of amatoxins, such as α-, β-, and γ-amanitin, within the first few hours after presentation is necessary to improve the therapeutic outcomes of patients. Therefore, analytical methods for the identification and quantification of α-, β-, and γ-amanitin in biological samples are necessary for clinical and forensic toxicology. This study presents a literature review of the analytical techniques available for amatoxin detection in biological matrices, and established an inventory of liquid chromatography (LC) techniques with mass spectrometry (MS), ultraviolet (UV) detection, and electrochemical detection (ECD). LC-MS methods using quadrupole tandem mass spectrometry, time-of-flight mass spectrometry, and orbitrap MS are powerful analytical techniques for the identification and determination of amatoxins in plasma, urine, serum, and tissue samples, with high sensitivity, specificity, and reproducibility compared to LC with UV and ECD, enzyme-linked immunoassay, and capillary electrophoresis methods.

Sensitive Determination of Felodipine in Human Plasma by LC-MS/MS

  • Kim, Ho-Hyun;Roh, Hyeon-Jin;Lee, He-Joo;Han, Sang-Beom
    • Proceedings of the PSK Conference
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.1
    • /
    • pp.283.2-283.2
    • /
    • 2003
  • This study established a highly sensitive novel quantification method for detecting felodipine in human plasma using LC-MS/MS. The mobile phase used after degassing was composed of 1 mM ammonium acetate and acetonitrile (20:80, pH 6.0), with flow rate of 200 uL/min. One mL plasma were pipetted into glass tubes and spiked with 0.1 mL of internal standard solution. (omitted)

  • PDF

Determination of Glimepiride in Human Plasma by LC-MS/MS

  • Kim, Ho-Hyun;Roh, Hyeong-Jin;Lee, Hee-Joo;Han, Sang-Beom
    • Proceedings of the PSK Conference
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.1
    • /
    • pp.282.1-282.1
    • /
    • 2003
  • This study established a sensitive novel Quantification method for detecting glimepiride in human plasma using LC-MS/MS for pharmacokinetic studies. The mobile phase used after degassing was composed of 10 mM ammonium acetate and acetonitrile (20:80, pH 3.0), with flow rate of 200uL/min. One mL plasma were pipetted into glass tubes and spiked with 0.1 mL of internal standard solution. (omitted)

  • PDF

A Dilute-and-Shoot LC-MS/MS Method for Screening of 43 Cardiovascular Drugs in Human Urine

  • Pham, Thuy-Vy;Lee, Gunhee;Mai, Xuan-Lan;Le, Thi-Anh-Tuyet;Nguyen, Thi Ngoc Van;Hong, Jongki;Kim, Kyeong Ho
    • Mass Spectrometry Letters
    • /
    • 제12권1호
    • /
    • pp.1-10
    • /
    • 2021
  • A simple, specific, and economical LC-MS/MS method was investigated for the screening of 43 prescribed antihypertensive and related drugs in human urine. The urine samples were simply prepared by diluting and mixing with internal standard before directly introduced to the LC-MS/MS system, which is fast, straightforward, and cost-effective. Fractional factorial, Box-Behnken, and I-optimal design were applied to screen and optimize the mass spectrometric and chromatographic factors. The analysis was carried out on a triple quadrupole mass spectrometer system utilizing multiple reaction monitoring with positive and negative electrospray ionization method. Chromatographic separation was performed on a Thermo Scientific Accucore RP-MS column (50 × 3.0 mm ID., 2.6 ㎛) using two separate gradient elution programs established with the same mobile phases. Chromatographic separation was performed within 12 min. The optimal method was validated based on FDA guideline. The results indicated that the assay was specific, reproducible, and sensitive with the limit of detection from 0.1 to 50.0 ㎍/L. The method was linear for all analytes with coefficient of determination ranging from 0.9870 to 0.9981. The intra-assay precision was from 1.44 to 19.87% and the inter-assay precision was between 2.69 and 18.54% with the recovery rate ranges from 84.54 to 119.78% for all drugs measured. All analytes in urine samples were stable for 24 h at 25℃, and for 2 weeks at -60℃. The developed method improves on currently existing methods by including larger number of cardiovascular medications and better sensitivity of 12 analytes.

A Study on Extraction and Analysis of Red Dyed Fabric (적색 염직물의 색소 추출 방법 및 분석연구)

  • Imn, Se Yeon;Chung, Yong Jae
    • Journal of Conservation Science
    • /
    • 제32권3호
    • /
    • pp.385-394
    • /
    • 2016
  • A fabric excavated from tombs or passed down is not easy to find its original color as it degrades and discolors by UV and visible rays, oxygen and microorganisms. LC-MS analysis is commonly used for separating and analyzing colors, but color extraction process is complicated and important in dye-qualitative analysis. To extract red colors from a fabric which is dyed with safflower and lac, solvents; hydrogen chloride, pyridine and oxalic acid are used and oxalic acid was the most effective solvent. Meanwhile, dyed samples were put in degradation condition; UV-A for 168 hours and analyzed with LC-MS to find out its colors'chemical changes. As a result, carthamin is detected in $T_R$ 13 min and laccaic acid A is detected in $T_R$ 10 min. However carthamin is not detected in a degraded fabric dying with safflower, it could be identified as a safflower fabric by the molecular weight of m/z 931. Through this study the most optimal method for red color extraction is found so it is expected to be used as a base line data for red color LC-MS analysis.

Effects of Column Length and Particle Diameter on Phospholipid Analysis by Nanoflow Liquid Chromatography-Electrospray Ionization-Mass Spectrometry

  • Lee, Ju-Yong;Lim, Sang-Soo;Moon, Myeong-Hee
    • Mass Spectrometry Letters
    • /
    • 제2권3호
    • /
    • pp.65-68
    • /
    • 2011
  • The effects of column length and particle size on the efficiency of separation and characterization of phospholipids (PLs) are investigated using nanoflow liquid chromatography-electrospray ionization-tandem mass spectrometry (nLC-ESI-MS-MS). Since PLs are associated with cell proliferation, apoptosis, and signal transduction, it is of increasing interests in lipidomics to establish reliable analytical methods for the qualitative and quantitative profiling of PLs related to biomarker development in adult diseases. Due to the complexity of PLs, the preliminary separation of PLs is necessary prior to MS analysis. In this study, length of capillary column and the particle size of reversed phase ($C_{18}$) packing materials are varied to find a reliable condition for the high speed and high resolution separation using 8 PL standard mixtures. From experiments, it was found that a capillary column of nLC-ESI-MS-MS analysis for PL mixtures can be minimized to a 5 cm long pulled tip column packed with 3 ${\mu}m$ $C_{18}$ particles without losing resolution.