• Title/Summary/Keyword: LC/ESI/MS

Search Result 213, Processing Time 0.019 seconds

Simultaneous determination of preservatives in sausages using liquid chromatography with electrospray ionization tandem mass spectrometry (LC-MS/MS를 이용한 소시지 중 보존료 동시분석)

  • Koh, Ba-Ra-Da;Kim, Ji-Yeon;Jang, Mi-Sun;Seo, Doo-Ri;Jung, Bo-Ram;Shin, Ji-Hyun;Lim, Jin-Taek;Kim, Yong-Hwan;Kim, Eun-Sun
    • Korean Journal of Veterinary Service
    • /
    • v.38 no.2
    • /
    • pp.127-136
    • /
    • 2015
  • A simultaneous determination method was developed for nine preservatives (benzoic acid, sorbic acid, dehydroacetic acid, methyl-, ethyl-, isopropyl-, propyl-, isobutyl- and butyl-parabens) in sausage by liquid chromatography with electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS). Each parameter was established by multiple reaction monitoring in negative mode. Separation was achieved on a phenyl-hexyl ($2.5{\mu}m$, $2.1{\times}150mm$, Waters) with A-20 mM ammonium acetate containing 0.1% acetic acid in water, B-Acetonitrile as mobile phase with gradient mode at a flow rate of 0.3 mL/min. The developed method was validated for specificity, linearity, accuracy and precision in sausages samples. Linearity was over 0.998 with calibration curve of the mixed standards. The mean recoveries from sausages fortified at the level of 2.0~10.0 mg/L were in range of 98.60~109.16% with RSDs lower than 8.93%. The limits of detection (LOD) and the limits of quantification (LOQ) were in the range between 0.0003~0.085 mg/L and 0.01~0.257 mg/L, respectively. Intra-day precision and inter-day precision were 0.45~6.16% and 2.81~13.33%, respectively. Using presently developed determination method, 33 field sausage samples from Gwangju city in Korea were screened over nine preservatives. As a result, no preservatives were detected in all samples.

ACAT (Acyl-CoA:cholesterol Acyltransferase) Inhibitory Effect and Quantification of Pyranocurmarin in Different Parts of Angelica gigas Nakai (참당귀(Angelica gigas)에서 분리한 pyranocurmarin 성분의 ACAT 저해활성 및 참당귀 부위별 pyranocurmarin 성분의 함량 분석)

  • Kim, Geum-Soog;Park, Chun-Geun;Jeong, Tae-Sook;Cha, Seon-Woo;Baek, Nam-In;Song, Kyung-Sik
    • Journal of Applied Biological Chemistry
    • /
    • v.52 no.4
    • /
    • pp.187-194
    • /
    • 2009
  • Two pyranocoumarin constituents have been isolated from Angelica gigas and were identified as decursinol angelate (1) and decursin (2) by means of NMR analysis, respectively. Human acyl-CoA:cholesterol acyltransferase (hACAT) inhibitory activity of decursinol angelate (1) and decursin (2) was evaluated. Decursin (2) showed significantly inhibitory activity against hACAT1 and hACAT2 with $IC_{50}$ value of 137 and $168\;{\mu}M$, respectively, whereas decursinol angelate (1) exhibited weak ACAT inhibitory activity. These results suggested that decusin from A. gigas might be effective for the prevention and the treatment of hypercholesterolemia or atherosclerosis by inhibitory effect on hACAT. The contents of decursinol angelate (1) and decursin (2) were analyzed in various parts of A. gigas including flower, seed, leaf and root using LC/MS/MS (ESI, positive ion mode, MRM mode). The content of decursinol angelate was increased in order of flower, seed, leaf, and root and decursin content was increased in order of flower, seed, leaf, and root. It was expected that unused parts including leaf and flower of A. gigas might be useful as new functional sources by their high contents of decursin and decursinol angelate.

The study of analytical method for sulfonamide antibiotics and their metabolites in environmental samples (환경 시료 중 설폰아미드계 항생제 및 대사체 분석방법 연구)

  • Kang, Young-Yeul;Hwang, Seung-Ryul;Shin, Sun-Kyoung;Koo, So-Hyun;Sim, Ki-Tae;Kim, Tae-Seung
    • Analytical Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.437-445
    • /
    • 2010
  • The aim of this study was to develop an analytical method for sulfonamide antibiotics (sulfadiazine, sulfamerazine, sulfamethazine, sulfamethoxazole, sulfathiazole) and their metabolites ($N^4$-acetylsulfadiazine, $N^4$-acetylsulfamerazine, $N^4$-acetylsulfamethazine, $N^4$-acetylsulfamethoxazole, sulfamethoxazole-$N^1$-glucuronide) in environmental samples. The solid phase extraction (SPE) with LC/ESI-MS/MS have been used for the analysis of target compounds, and the recoveries of SPE clean-up were at the range of 12-94% for C18 cartridge, 60-95% for HLB cartridge, 25-123% for MCX cartridge, and 70-90% for tandem HLB/MCX. By established method, detection limit, recovery, and relative standard deviation were 0.001~0.187 ng/mL, 66~115%, and 5~17%, respectively. This method was effective and sensitive to use for the simultaneous determination of sulfonamide antibiotics and their metabolites in environmental samples. Four sulfonamide antibiotics were detected at the range of 0.008~2.153 ng/mL. For metabolites, only $N^4$-acetylsulfamethoxazole was detected, but the concentration was under the MDL level.

Determination of finasteride in human serum by LC-MS/MS (LC-MS/MS를 이용한 혈청 중 finasteride 분석)

  • Nam, Hye-Seon;Nam, Kyong-Hee;Jung, Su-Hee;Lee, Jang-Woo;Kang, Jin-Yeong;Hong, Soon-Keun;Kim, Tae-Sung;Kang, Tae-Seok;Yoon, Hae-Jung;Lee, Kwang-Ho;Rhee, Gyu-Seek
    • Analytical Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.345-351
    • /
    • 2011
  • A liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS) method was developed and validated for the determination of finasteride in human serum. Beclomethasone was used as internal standard (IS) and liquid-liquid extraction (LLE) using methyl tert-butyl ether (MTBE) was carried out to isolate analyte. The mass transitions monitored in multiple reaction monitoring (MRM) in positive ion mode were m/z 373.2${\rightarrow}$305.2 for finasteride and m/z 409.3${\rightarrow}$391.2 for IS. Retention times of finasteride and IS were 5.81 and 5.46 min, respectively. The limit of quantitation (LOQ) was 0.1 ng/mL and the calibration curve showed good linearity in the range of 0.1~20.0 ng/mL ($R^2$=0.9997). The intra-day assay precision and accuracy were in the range 6.3~10.6% and 97.3~103.6%, respectively, and the inter-day assay precision and accuracy were in the range 0.8~5.2% and 99.8~102.5%, respectively. The sample extract recovery of the method was 80~83%.

Analysis of dutasteride in human serum by LC-MS/MS (LC-MS/MS를 이용한 혈청 중 dutasteride 분석)

  • Nam, Hye-Seon;Nam, Kyong-Hee;Jung, Su-Hee;Lee, Jang-Woo;Kang, Jin-Yeong;Hong, Soon-Keun;Kim, Tae-Sung;Jung, Ki-Kyung;Kang, Tae-Seok;Yoon, Hae-Jung;Lee, Kwang-Ho;Rhee, Gyu-Seek
    • Analytical Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.76-82
    • /
    • 2012
  • The determination and confirmation of dutasteride in human serum was performed by a liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS). Beclomethasone as an internal standard (I.S.) was added to the serum and the mixed sample was pretreated by liquid-liquid extraction (LLE) with methyl tert-butyl ether (MTBE). The mass transitions of dutasteride and I.S. monitored in multiple reaction monitoring (MRM) were m/z 529.6${\rightarrow}$461.5 and m/z 409.3${\rightarrow}$391.2, respectively, and the retention times were 6.45 and 5.46 min, respectively. The calibration curve was linear in the concentration range of 0.5~30.0 ng/mL ($R^2$= 0.9999) and the limit of quantitation (LOQ) was found to be 0.5 ng/mL. The recovery of dutasteride was shown to be 66~72%. The intra-day assay precision and accuracy were in the range 3.5~5.5% and 85.7~89.9%, respectively, and the interday assay precision and accuracy were in the range 4.2~5.8% and 90.8~95.8%, respectively.

Simultaneous Determination of the Seven Phenylpropanoids in Xanthii Fructus Using a HPLC-PDA and LC-MS

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • Natural Product Sciences
    • /
    • v.24 no.3
    • /
    • pp.206-212
    • /
    • 2018
  • Xanthii Fructus has been traditionally used for the treatment of rhinitis, rheumatoid arthritis, and eczema. In this study, a high-performance liquid chromatography-photodiode array (HPLC-PDA) method was developed and then used for the simultaneous analysis of eight phenylpropanoids in Xanthii Fructus. The analytical column used for this separation was a $SunFire^{TM}$ $C_{18}$ column, maintained at $40^{\circ}C$. The mobile phase used was 1.0% acetic acid in distilled water and 1.0% acetic acid in acetonitrile with gradient elution. For identify of each component, the mass spectrometer (MS) was used a Waters triple quadrupole mass spectrometer requipped with electrospray ionization (ESI) source. The HPLC-PDA method showed good linearity: correlation coefficients were ${\geq}0.9996$. The limits of detection and quantification of the eight compounds were 0.02 - 0.04 and $0.06-0.14{\mu}g/mL$, respectively. The extraction recoveries ranged from 97.51 to 108.67%. The relative standard deviation values of intra- and inter-day precision were 0.06 - 1.55 and 0.09 - 1.68%, respectively. The validated HPLC-PDA method was applied to simultaneously analyse the amounts of eight phenlypropanoids in Xanthii Fructus.

High Accuracy Mass Measurement Approach in the Identification of Phospholipids in Lipid Extracts: 7 T Fourier-transform Mass Spectrometry and MS/MS Validation

  • Yu, Seong-Hyun;Lee, Youn-Jin;Park, Soo-Jin;Lee, Ye-Won;Cho, Kun;Kim, Young-Hwan;Oh, Han-Bin
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.4
    • /
    • pp.1170-1178
    • /
    • 2011
  • In the present study, the approach of high accuracy mass measurements for phospholipid identifications was evaluated using a 7 T ESI-FTMS/linear ion trap MS/MS. Experiments were carried out for porcine brain, bovine liver, and soybean total lipid extracts in both positive and negative ion modes. In total, 59, 55, and 18 phospholipid species were characterized in the positive ion mode for porcine brain, bovine liver, and soybean lipid extracts, respectively. Assigned lipid classes were PC, PE, PEt, PS, and SM. In the negative ion mode, PG, PS, PA, PE, and PI classes were observed. In the negative ion mode, for porcine brain, bovine liver, and soybean lipid extracts, 28, 34, and 29 species were characterized, respectively. Comparison of our results with those obtained by other groups using derivatization-LC-APCI MS and nano-RP-LC-MS/MS showed that our approach can characterize PC species as effectively as those methods could. In conclusion, we demonstrated that high accuracy mass measurements of total lipid extracts using a high resolution FTMS, particularly, 7T FTMS, plus ion-trap MS/MS are very useful in profiling lipid compositions in biological samples.

Heterologous Production and Detection of Recombinant Directing 2-Deoxystreptamine (DOS) in the Non-Aminoglycoside-Producing Host Streptomyces venezuelae YJ003

  • Kurumbang, Nagendra Prasad;Oh, Tae-Jin;Liou, Kwangkyoung;Sohng, Jae-Kyung
    • Journal of Microbiology and Biotechnology
    • /
    • v.18 no.5
    • /
    • pp.866-873
    • /
    • 2008
  • 2-Deoxystreptamine is a core aglycon that is vital to backbone formation in various aminoglycosides. This core structure can be modified to develop hybrid types of aminoglycoside antibiotics. We obtained three genes responsible for 2-deoxystreptamine production, neo7, neo6, and neo5, which encode 2-deoxy-scyllo-inosose synthase, L-glutamine: 2-deoxy-scyllo-inosose aminotransferase, and dehydrogenase, respectively, from the neomycin gene cluster. These genes were cloned into pIBR25, a Streptomyces expression vector, resulting in pNDOS. The recombinant pNDOS was transformed into a non-aminoglycoside-producing host, Streptomyces venezuelae YJ003, for heterologous expression. Based on comparisons of the retention time on LC-ESI/MS and ESI-MS data with those of the 2-deoxystreptamine standard, a compound produced by S. venezuelae YJ003/pNDOS was found to be 2-deoxystreptamine.

Determination of Veterinary Antibiotic Residues: IV. Comparable Analytical Methods with EPA Methods 1694_A Review (시료 중 잔류 항생제 분석 방법: IV. EPA method 1694와 비교 가능한 기기 분석 방법)

  • Kim, Chansik;Ryu, Hong-Duck;Chung, Eu Gene;Kim, Yongseok;Rhew, Doug Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.6
    • /
    • pp.670-699
    • /
    • 2016
  • In this study, 16 antibiotics were selected from among the top 30 veterinary antibiotics sold in South Korea in 2014, as well as from among the pharmaceuticals targeted by EPA method 1694, in order to review analytical methods for the detection of trace levels of antibiotics in environmental samples: surface water, soils, animal origin foods, and manures. LC-MS/MS was heavily used. In the chromatography for the detection of the selected antibiotics, the $C_{18}$ column was mostly used at the temperature of $30{\sim}40^{\circ}C$. Water and methanol/acetonitrile were commonly chosen as a nonpolar and a polar mobile phase, respectively. Gradient elution was applied to separate multiclass antibiotics. Volatile additives, such as formic acid, acetic acid, and ammonium acetate were mixed with the mobile phase to improve the ionization efficiency of analytes and the sensitivity in MS detection. Electrospray ionization (ESI) was widely used in the LC-MS/MS and positive ionization was preferred to determine the selected antibiotics. A protonated $[M+H]^+$ molecule was selected as a precursor ion, and its two transitions were analyzed, one for quantitative measurement and the other for confirmation. This study reviewed linearity of the calibration curve, recovery, repeatability, method detection limits (MDLs), and method quantification limits (MQLs) for each target compound used to validate the developed analytical methods.

Simultaneous Determination of Non-steroidal Anti-inflammatory Drugs and Corticosteroids Added to Foods as Adulterants using LC-ESI-tandem Mass Spectrometry (LC/ESI-MS/MS를 이용한 식품 중 불법적으로 첨가된 비스테로이드성 소염진통제 및 스테로이드 의약품 동시분석)

  • Lee, Yongcheol;Park, Ju-Sung;Kim, Sung-Dan;Yang, Hye-Ran;Kim, Eun-Hee;Yi, Yun-Jung;Cho, Sung-Ja;Jo, Han-Bin;Kim, Jung-Hun;Chae, Young-Zoo
    • Journal of Food Hygiene and Safety
    • /
    • v.28 no.3
    • /
    • pp.247-251
    • /
    • 2013
  • The objective of present study was to develop a simultaneous determination method of 5 medical compounds, including beclomethasone, dexamethasone, prednisolone, ketoprofen, phenylbutazone in foods, using LC-MS/MS. To optimize MS analytical condition of 5 compounds, each parameter was established by MRM mode. The chromatographic separation was achieved on a C18 column successfully, with a mobile phase made up of A (0.1% formic acid) and B (0.1% formic acid in acetonitrile), at a flow rate of 0.3 mL/min for 17 min with a gradient elution. LOD and LOQ of 5 compounds were in the range of 0.40~4.60 ng/mL and 0.81~11.46 ng/mL, respectively. As a result of analyzing the three concentrations of the standard mixture added to blank samples, the results showed that the mean recovery rate of 5 compounds was in the range of 81.52~103.83%, and RSD (%) of Intra- and Inter-day assay were 0.52-10.45. Since relatively fine selectivity, accuracy and reproducibility were shown in this qualified experimental method, it could be utilized efficiently to investigating those 5 compounds to see if it is added to food products illegally.