A Study of assessment criteria and reliability improvement for power supply of electrodeless fluorescent lamp (고효율 무전극형광등용 전원장치의 평가기준 및 신뢰성향상 연구)

  • 함증걸;신종욱
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.2
    • /
    • pp.34-40
    • /
    • 2003
  • This paper gives an assessment criteria and reliability improvement for high frequency power supply of high efficacy electrodeless fluorescent lamp. The electrodeless fluorescent lamp system consist of electrodeless fluorescent lamp, high frequency power supply and lighting fixtures. The high frequency power supply has a shortest life at the system. Therefore It is need th assess the Failure Rate or mean Time To Failure(MTTF) for the high frequency power supply of electrodeless fluorescent lamp system and improve the reliability at design. We suggest the assessment criteria and improve methods of the reliability on the design basis for the electodeless fluorescent system.

Development of the RTP System for Metal Alloy using One Lamp (한 개의 Lamp를 이용한 Metal Alloy용 RTP 장비 개발)

  • Choi, Jin-Ho;Lee, Dong-Youb
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.254-257
    • /
    • 1996
  • A Rapid Thermal Processing (RTP) system operated below $500^{\circ}C$ has been designed and constructed. It uses an optical pyrometer for measuring wafer temperature, the sensing range of pyrometer is from $2.0{\mu}m$ to $2.4{\mu}m$. To remove the interference effect by IR emitted from lamps an IR filter is adapted which uses water. The best condition for Al alloy using the RTP system is $425^{\circ}C$ for ten seconds. The RTP system uses many lamps for supplying enough power in processing wafer because the absorption wavelength range of IF filter is from $1.3{\mu}m$ to $4.0{\mu}m$. However, reproducibility and uniformity is reduced due to the difference of lamp characteristics. Therefore, for improving the reproducibility and uniformity new RTP system using one lamp is designed. The new RTP system uses a focusing mirror and it focuses the light of lamp. The curverture of the focusing mirror is controlled to supply uniform power in processing wafer. The result of computer simulation shows the possibility of new RTP system using one lamp.

  • PDF

Loop-mediated Isothermal Amplification (LAMP) for Detection of Streptococcus parauberis (Loop-mediated isothermal amplification (LAMP)법을 이용한 Streptococcus parauberis 의 신속 진단)

  • Moon, Kyung-Mi;Kim, Dong-Hwi;Heo, Moon-Soo
    • Journal of Life Science
    • /
    • v.24 no.4
    • /
    • pp.428-436
    • /
    • 2014
  • Loop-mediated isothermal amplification (LAMP) technique relies on autocycling strand displacement DNA sysnthesis without template denaturation steps under isothermal conditions. LAMP has more advantages than modern PCR, as it requires only basic laboratory equipment like an isothermal water bath, oven, and heating cabinet. Hence, in this study, five random primers were designed with Streptococcus parauberis, shikimate kinase Arok gene sequences (Genbank accession number: CP0024711). Two primers were selected based on the ladder pattern. Other optimum reaction conditions like temperature, time, and sensitivity were established and confirmed with conventional SYBR-green PCR. Results confirmed that the designed random primers were species specific, without any non-target DNA amplification under isothermal conditions. Hence, this study suggests that LAMP techniques could be used in the diagnosis of fish pathogen, specifically S. parauberis.

Improved Heat Lamp for Preventing Arterial Spasm after Microvascular Surgery (미세혈관 수술 후 혈관 연축의 예방을 위한 개선된 온열전등)

  • Ahn, Sung-Min;Hwang, So-Min;Hu, Eun-Suk;Park, Jung-Mi;Park, Kyung-A;Oh, Jin-A
    • Archives of Reconstructive Microsurgery
    • /
    • v.17 no.2
    • /
    • pp.120-125
    • /
    • 2008
  • Purpose: Heat therapy by heat lamp after microvascular surgery is being used for preventing blood vessels's contraction and blood-flow's disturbance. As usually, incandescent lamp has been used. But there have been several problems and need for improvement in the existing heat lamp treatment. So we would like to introduce improved heat lamp to keep an appropriate temperature and intensity of illumination. Methods: The existing heat lamps are the ones of general light stands covered with newspaper, having 60 watt light bulb of incandescence and lampshade made of aluminum. We have tried to improve shortcomings of the existing heat lamps by enlarging the size of aluminum lampshade and attaching a curtain that can block heat and light. We conducted a comparative study between the existing and improved heat lamps. Under the assumption that there are several affected parts, we have also measured the distance from heat lamp to patients' eye region and then intensity of illumination. Result: The target temperature of surface was realized in 11 minutes with the maximum temperature reaching at 36.6 degrees C in 28 minutes at the existing heat lamp while the target temperature reached in 7 minutes with the maximum temperature reaching at 39.0 degrees C in 17 minutes at the improved heat lamp. The existing and improved heat lamp showed 38 lx and 0.1 lx of intensity of lumination, respectively. Conclusion: Using improved heat lamps, we can keep an appropriate temperature and we think we can make contribution to patients' treatment by making them and their neighbors able to sleep with minimized disturbance thanks to low intensity of illumination secured by blocking light.

  • PDF

A Non-Linear Characteristics Modeling of High Frequency FL Lamp by Experimental Values (실험식을 이용한 고주파 형광램프의 비선형특성 모델링)

  • 함중걸;백수현
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.2
    • /
    • pp.51-55
    • /
    • 1997
  • The high frequency fluorescnet lighting systems are widely used because of their high luminous efficacy. However, the performance of the fluorescnet lamp at high frequency reveals significant changes depending upon operating frequency, lamp shape, lamp voltage and current while adapting either an electronic or an magnetic ballast. Therefore the matching between the fluorescent lamp and the ballast is the major concern in designing a lighting system. In this paper, high frequency characteristics of the FHF32W lamp is measured in a range of frequencies from 12kHz to 50kHz. And we presented a model of a fluorescnet lamp with non-linear impedance depending on the lamp current. Finally, after identifying the operating condition under negative imped¬ance behavior as lamp current changing, we proposed a method of choosing the optimal parameter of a high frequency fluorescnet lamp and the result is analyzed.

  • PDF

Implementation of Preceding Vehicle Break-Lamp Detection System using Selective Attention Model and YOLO (선택적 주의집중 모델과 YOLO를 이용한 선행 차량 정지등 검출 시스템 구현)

  • Lee, Woo-Beom
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.2
    • /
    • pp.85-90
    • /
    • 2021
  • A ADAS(Advanced Driver Assistance System) for the safe driving is an important area in autonumous car. Specially, a ADAS software using an image sensors attached in previous car is low in building cost, and utilizes for various purpose. A algorithm for detecting the break-lamp from the tail-lamp of preceding vehicle is proposed in this paper. This method can perceive the driving condition of preceding vehicle. Proposed method uses the YOLO techinicque that has a excellent performance in object tracing from real scene, and extracts the intensity variable region of break-lamp from HSV image of detected vehicle ROI(Region Of Interest). After detecting the candidate region of break-lamp, each isolated region is labeled. The break-lamp region is detected finally by using the proposed selective-attention model that percieves the shape-similarity of labeled candidate region. In order to evaluate the performance of the preceding vehicle break-lamp detection system implemented in this paper, we applied our system to the various driving images. As a results, implemented system showed successful results.

A Study on Numerical Analysis of Thermal Flow in Solar Lamp Bank (솔라 램프뱅크 내의 열유동 수치해석에 관한 연구)

  • Kim, Sung-Dae;Ryoo, Seong-Ryoul;Baek, Sang-Hwa;Lee, Jeong-Yong;Park, So-Jin;Kim, Chul-Ju;Ko, Han-Seo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.136-143
    • /
    • 2008
  • A three-wavelength solar bank is a very important part for a solar simulator with commercial superlux lamps. It is projected metal halide lamps to satisfy following points simultaneously: $\pm$10% of uniformity for irradiance of target area and irradiance in each wave region, and $1,232W/m^2$ of maximum solar irradiance in summer. The developed solar lamp bank has been analyzed numerically by commercial programs in this study to carry out experiments. In conclusion, designed B-type heat lamp is not concentrated in one place than designed A-type heat lamp, it is spreaded widely, and it was proved numerical computation. We suggest that solar simulator is applied to actual experiment test through heat flow numerical analysis in solar lamp bank and the lamp is applied private industry or the military using complex environmental assessment test.

The Development of Material Separation Technique for Recycling of Waste Car Tail Lamp (폐자동차(廢自動車) Tail Lamp의 재활용(再活用)을 위한 재질분리(材質分離) 기술개발(技術開發))

  • Jeon, Ho-Seok;Park, Chul-Hyun;Baek, Sang-Ho;Park, Jai-Koo
    • Resources Recycling
    • /
    • v.15 no.6 s.74
    • /
    • pp.25-32
    • /
    • 2006
  • In this study, waste car tau lamps that usually gets incinerated or buried has been recovered during the dispose process in order to increase the recycling rate of waste cars and the material separation research was performed by applying triboelectrostatic separation method. After a series of charging characteristic test, PMMA materials was confirmed of being an effective charging material for waste car tail lamp material separation, a cyclone charger using PMMA material for continuous process was developed. In optimum test conditions using triboelectrostatic separator developed in this study, high quality PMMA material with recovery rate of 99.0% and 90.2% was achieved from the waste car tail lamp. Therefore, a material separation technology that can recycle tail lamps of waste cars has been established.

Comparison of clinical diagnostic performance between commercial RRT-LAMP and RT-qPCR assays for SARS-CoV-2 detection

  • Kim, Hye-Ryung;Park, Jonghyun;Han, Hyung-Soo;Kim, Yu-Kyung;Jeon, Hyo-Sung;Park, Seung-Chun;Park, Choi-Kyu
    • Korean Journal of Veterinary Service
    • /
    • v.44 no.3
    • /
    • pp.163-168
    • /
    • 2021
  • The rapid and reliable detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) plays a key role in isolating infected patients and preventing further viral transmission. In this study, we evaluated the clinical diagnostic performances of a commercial real-time reverse transcription loop-mediated isothermal amplification (RRT-LAMP) assay (Isopollo® COVID-2 assay, M-monitor, Daegu, Korea) using eighty COVID-19 suspected clinical samples and compared these with the results of a commercial real-time reverse transcription polymerase chain reaction (RT-qPCR) assay (AllplexTM 2019-nCoV rRT-QPCR Assay, SeeGene, Seoul, Korea). The results of the RRT-LAMP assay targeting the N or RdRp gene of SARS-CoV-2 showed perfect agreement with the RT-qPCR assay results in terms of detection. Furthermore, the RRT-LAMP assay was completed in just within a 20-min reaction time, which is significantly faster than about the 2 h currently required for the RT-qPCR assay, thus enabling prompt decision making regarding the isolation of infected patients. The RRT-LAMP assay will be a valuable tool for rapid, sensitive, and specific detection of SARS-CoV-2 in human or unexpected animal clinical cases.

Electrical Characteristics of 28w class-Piezoelectric Transformer for Fluorescent Lamp Ballast as a function of Load Resistance (형광등 안정기용 고출력 (28W급)압전트랜스포머의 부하저항에 따른 전기적 특성)

  • Hwang, S.M.;Lee, J.S.;Yoo, J.H.;Park, C.Y.;Lee, S.H.;Lee, S.I.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.135-139
    • /
    • 2001
  • Contour vibration mode piezoelectric transformers were designed and fabricated to the square plate with size of $27.5{\times}27.5{\times}2.5(2.6,\;3.0)mm^3$ using PNW-PMN-PZT ceramics. Electrical characteristics of the piezoelectric transformer were investigated for fluorescent lamp ballast application. The electrical properties and characteristic temperature rise were measured using oscilloscope and infrared temperature sensor. A 28W fluorescent lamp was successfully driven by the fabricated transformers. After driving the lamp using Power Amplifier for 24 min, the output power, efficiency and characteristic temperature rise of PT2 piezoelectric transformer showed the appropriate values of 28.01 W, 99.43% and $11^{\circ}C$, respectively. The electronic ballast using PT2 piezoelectric transformer showed an excellent output power of 28.85 W and efficiency of 86.3%, respetively.

  • PDF