• Title/Summary/Keyword: L-Tube

Search Result 792, Processing Time 0.032 seconds

Syringo-Subarachnoid-Peritoneal Shunt Using T-Tube for Treatment of Post-Traumatic Syringomyelia

  • Kim, Seon-Hwan;Choi, Seung-Won;Youm, Jin-Young;Kwon, Hyon-Jo
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.1
    • /
    • pp.58-61
    • /
    • 2012
  • Various surgical procedures for the treatment of post-traumatic syringomyelia have been introduced recently, but most surgical strategies have been unreliable. We introduce the concept and technique of a new shunting procedure, syringo-subarachnoid-peritoneal shunt. A 54-year-old patient presented to our hospital with a progressive impairment of motion and position sense on the right side. Sixteen years before this admission, he had been treated by decompressive laminectomy for a burst fracture of L1. On his recent admission, magnetic resonance (MR) imaging studies of the whole spine revealed the presence of a huge syrinx extending from the medulla to the L1 vertebral level. We performed a syringo-subarachnoid-peritoneal shunt, including insertion of a T-tube into the syrinx, subarachnoid space and peritoneal cavity. Clinical manifestations and radiological findings improved after the operation. The syringo-subarachnoid-peritoneal shunt has several advantages. First, fluid can communicate freely between the syrinx, the subarachnoid space, and the peritoneal cavity. Secondly, we can prevent shunt catheter from migrating because dural anchoring of the T-tube is easy. Finally, we can perform shunt revision easily, because only one arm of the T-tube is inserted into the intraspinal syringx cavity. We think that this procedure is the most beneficial method among the various shunting procedures.

Influence of Working Fluids to Heat Transfer Characteristics of the Heat Exchanger using Oscillating Capillary Tube Heat Pipe for Low Temperature Waste Heat Recovery (저온 폐열회수용 진동세관형 히트파이프 열교환기의 작동 유체에 따른 열전달 특성)

  • 이욱현;임용빈;김정훈;김종수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.7
    • /
    • pp.659-666
    • /
    • 2000
  • Heat transfer characteristics of a heat exchanger for low temperature waste heat recovery using oscillating capillary tube heat pipe were evaluated against the charge ratio variation of working fluid and various working fluids. R-l42b, R-22 and R-290 were used as working fluids. The heat exchanger was composed of heat pipe with capillary tube bundles, having a 2.6mm in outer diameter, 1.4mm in inner diameter with 101m long, and 40 turns. Charge ratio of working fluid was 40% and 50%. Water was used as secondary fluid. Inlet temperature and mass velocity for each secondary fluid were 297 K, 280 K and9~27 kg /$m^2s$,, respectively. From experimental results, it was found that heat transfer performance of R-22 was higher than those of R-l42b and R-290 and it was proportional to Figure of merit for thermosyphons. As a result, it was thought that R-22 was the most suitable working fluid of waste heat recovery for low temperature waste heat recovery.

  • PDF

An Analysis on Combustion Instability in Solid Rocket Motor of 4 Slotted Tube Grain (4 Slotted Tube형 고체 추진기관의 연소불안정 거동 현상 분석)

  • Cho, Ki-Hong;Kim, Eui-Yong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.4
    • /
    • pp.48-56
    • /
    • 2011
  • A Possibility of combustion instability on longitudinal mode has a high level at large scale of L/D. Solid propellant has a metal particle and a grain of control to pressure oscillation. Solid rocket motor in slotted-tube grain controls pressure oscillation of longitudinal mode. Slotted-tube grain restrains longitudinal 1st pressure oscillation. But cavity volume of aft. insulation ablation amplifies 2nd pressure o scillation by vortext shedding. A study has suppressed combustion instability and vortex shedding by modified 4 slotted tube solid rocket motor design.

Nitrogen Removal by Electrochemical Oxidation Using the Tube Type Electrode (튜브형 전극을 이용한 전기화학적 산화에 의한 질소제거에 관한 연구)

  • Cho, Jae-Jun;Jeong, Jong-Sik;Lee, Jae-Bok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.5
    • /
    • pp.580-587
    • /
    • 2004
  • The objective of this research is to investigate the electrochemical oxidation process for nitrogen removal in wastewater involving chloride ion and nitrogen compounds. The process experiment of electrochemical oxidation was conducted by using the stainless steel tube type reactor and the $Ti/IrO_2$ as anode. Free chlorine production and current efficiency variation for total nitrogen removal was compared depending on whether electrolyte is added, and the nitrogen type distribution under an operating condition. When chloride was added as electrolyte, it was found that production of free chlorine increased and the concentration of the chloride decreased as retention time passed. The concentration of chloride in influent decreased from 1,660 to 1,198 mg/L at the current density of $6.7A/dm^2$, while concentration of free chlorine increased to 132 mg/L. Current efficiency in removal of ammonium nitrogen was increased when chloride was dosed as electrolyte. It was observed that ammonium nitrogen was oxidized to nitrite and nitrate through electrochemical oxidation and that the concentration of total nitrogen in influent was reduced from 22.58 to 4.00 mg/L at the short retention time of 168 seconds through the electrochemical oxidation of nitrogen.

The measurement of Ozone Concentration and Simulation of Electric Field Distribution at Dielectric Tube of one Layer with Globular Dielectric in Water (구형 유전체비드를 가지는 단층절연방전관의 수(水)오존농도측정 및 전계분포 시뮬레이션)

  • Lee, Dong-Hoon;Park, Jae-Youn;Park, Hong-Jae;Koh, Hee-Seog;Lee, Hyun-Su
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.08a
    • /
    • pp.44-47
    • /
    • 2003
  • In this paper, the electric field distribution in dielectric tube with one layer and spherical dielectric($ZrO_2$) in water was simulated. The reactor was made up of the spherical dielectric that is diameter : 3.0[mm], $ZrO_2(\varepsilon_r:10)$ and one glass plate of thickness(2[mm]), $\varepsilon_r$(10) as electrode. The discharge gap was 8[mm]. To get more strong electric field, the dielectric constant should be higher comparatively. Using the spherical dielectric for water discharge in dielectric tube, the location of equipotential line was shifting from the interior to the exterior. At real water discharge experimental, ozone was measured higher dissolved ozone in water at condition of water rate(l[l/min]) and injector than condition of non-injector or 2~3[l/min].

  • PDF

Inhibitory Effects of Water Extract of Selaginella involvens on the Tube Formation and Invasion of Human Umbilical Vein Endothelial Cells (권백(Selaginella involvens) 물 추출물의 혈관 형성억제 및 혈관내피세포 이주 억제 효과)

  • Ko, Yu-Jin;Park, Seung-Hee;Lee, Yong-Hwa;Park, Byung-Chul;Hur, Jong-Hyun;Min, Yong-Deuk;Kim, Jae-Ki;Kim, Jung-Ae
    • YAKHAK HOEJI
    • /
    • v.51 no.1
    • /
    • pp.51-55
    • /
    • 2007
  • Among pteridophytes, Selaginella involvens Spring and Equisetum orvense L. are used in folk medicine in Eastern Asian countries including Korea. The water extracts from Selaginella involvens spring (SW) and from Equistum arvense L (EW) did not affect viability of human umbilical vein endothelial cells (HUVECs). However, SW dose-dependently inhibited tube formation and migration of HUVECs, whereas EW did not. These results suggest that the water extract from Selaginella involvens Spring may have anti-angiogenic activity.

Natural convection heat transfer in a horizontal annulus from an inner tube with two vertical fins (2개의 수직휜이 부착된 내관으로부터 환상공간내의 자연대류 열전달)

  • 정태현;정한식;권순석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.2
    • /
    • pp.654-660
    • /
    • 1991
  • Natural convection heat transfer in a horizontal annulus from an inner tube with two vertical fins has been studied for the effects of dimensionless fin length and Rayleigh number. The maximum local Nusselt number of inner tube was obtained at .theta. = 145.deg. and that of outer cylinder at .theta. = 0.deg. for the case of $l_{F}$=0.3 Local Nusselt number distributions for the lower fins show higher values than that of the upper fins. The mean Nusselt number of inner tube was increased with the values of dimensionless fin length. The mean Nusselt number can be represented in an exponential function of Grashof number at various fin lengths. As compared with experimental and numerical results, isotherms and local Nusselt number show good agreement.t.

Analysis of Hydroforming Process for Automobile Subframe by FEM (유한요소법을 이용한 자동차 Subframe의 하이드로포밍 공정 해석)

  • Chang Y. C.;Lei L. P.;Kang B. S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2000.10a
    • /
    • pp.149-152
    • /
    • 2000
  • By using a three-dimensional finite element program HydroFORM-3D based on a rigid-plastic model, the hydroforming process for automobile subfrmae is analyzed in this study. The goal of this study is to accomplish preform design and determine the level of internal pressure for producing final hydroformed subframe component. Prior to hydroforming, the initial tube blank must be bent to the approximate centerline of the final part to enable the tube to be placed in the die cavity, After then, a preforming operation like stamping is carried out to the prebent tube. Finally, hydroforming process is performed to the preformed tube to get the final production. And through ductile fracture theory, the failure, bursting, is predicted during hydroforming process for tube blank with different diameter.

  • PDF

Effect of Sucrose and Boric Acid on In Vitro Pollen Germination of Boxthorn (Lycium chinense M.) (자당과 붕산이 구기자 화분 발아에 미치는 영향)

  • Kim, Su Dong;Min, Byung Hoon;Yoon, Wha Mo;Lee, Ok Ran
    • Korean Journal of Medicinal Crop Science
    • /
    • v.21 no.5
    • /
    • pp.348-352
    • /
    • 2013
  • This study was carried out to investigate the effect of sucrose, boric acid, and calcium nitrate in optimum pH and relative humidity on pollen germination and pollen tube growth of boxthorn (Lycium chinense M.). Medium containing 100mg/L of $H_3BO_3$ showed maximum pollen germination and pollen tube elongation, 64.8% and $920{\mu}m$. Additionally supplied calcium nitrate to the medium lowered pollen germination rate and pollen tube elongation. Here we report the optimum conditions for the pollen germination and pollen tube development was observed at 10% sucrose, 1.0% agar, pH 6.0, and 100% relative humidity.

Unwinding Behavior of and Load Prediction for Protective Tube Around Fiber-Optic Cable (보호 튜브의 풀림 거동 및 하중 예측)

  • Kim, Kun Woo;Lee, Jae Wook;Kim, Hyung Ryul;Yoo, Wan Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.3
    • /
    • pp.235-241
    • /
    • 2014
  • As a fiber-optic cable is being unwound, it is protected by a tube that is designed to prevent unwinding problems such as tangling and unintentional cutting. In addition, a guide body is separated from the protective tube if a shear pin breaks when the maximum allowable load is exceeded. Therefore, it is important to analyze and predict the unwinding behavior of the protective tube, as well as the load on the shear pin, to enhance the likelihood of a successful operation when laying cables at extreme depths. In this study, the protective tube and the guide body are modeled with particles and are constrained with a constant-length constraint. The load on the shear pin was verified against experimental data, and the unwinding behavior was predicted from the load prediction results.