• Title/Summary/Keyword: L-Tube

Search Result 800, Processing Time 0.025 seconds

The Heat Transfer and Pressure drop Characteristics of R7l8 in Small Diameter Tubes (세관내 액단상의 열전달과 압력강하에 관한 연구)

  • 김세웅;홍진우;손창효;노건상;오후규
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.28-35
    • /
    • 2001
  • The heat transfer and pressure drop characteristics of R718 flowing in smooth horizontal copper tubes with inner diameter of 3.36 mm, 5.35 mm, 6.54 mm and 8.12 mm were investigated. The test section is a counterflow heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus. Experiments were peformed for the flowing range of variables : Reynolds number (1000 to 20000), mass flow rate of brine (450 kg/h) and refrigerant temperature (5$0^{\circ}C$). The main results were summarized as follows : (1) The heat transfer coefficient of 3.36 mm ID was about 10% to 30% higher than that of 5.35 mm, 6.54 mm and 8.12 mm ID, and the heat transfer coefficients for small diameter. tubes are about 20% to 27% higher than these predicted by Gnielinski. The new correlation is proposed to predict the experimental data. (2) As a result of comparison with correlation prosed by Blasius. the deviation of the experimental data slightly increased as the tube diameter decreased. (3) The ratio of heat transfer to friction factor (j/f) correlated by all experimental data increased as the tube diameter decreased.

  • PDF

Fabrication and Characteristics of HARP Image Pickup Tube Using a-Se Photoconductive Film (a-Se 광도전막을 이용한 HARP 촬상관의 제작 및 특성)

  • Park, Wug-Dong;Kim, Ki-Wan;Kubota, Misao;Kato, Tsutomu;Suzuki, Shiro;Tanioka, Kenkichi
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.17-22
    • /
    • 1998
  • A HARP (high-gain avalanche rushing amorphous photoconductor) image pickup tube using $4{\mu}m$ thick a-Se photoconductive film was fabricated and its characteristics were investigated. When the target voltage was increased more than 360 V, the signal current increases rapidly but the dark current of the tube was suppressed less than 3.2 nA up to the voltage of 490 V And the quantum efficiency of the target was about 4.3 at the electric field of $1.1{\times}10^{6}V/cm$ and the wavelength of 440 nm. Also the amplitude response of the HARP tube was 7.5% at 800 TV lines, and the decay lag was 3.4%.

  • PDF

GS-MARS method for predicting the ultimate load-carrying capacity of rectangular CFST columns under eccentric loading

  • Luat, Nguyen-Vu;Lee, Jaehong;Lee, Do Hyung;Lee, Kihak
    • Computers and Concrete
    • /
    • v.25 no.1
    • /
    • pp.1-14
    • /
    • 2020
  • This study presents applications of the multivariate adaptive regression splines (MARS) method for predicting the ultimate loading carrying capacity (Nu) of rectangular concrete-filled steel tubular (CFST) columns subjected to eccentric loading. A database containing 141 experimental data was collected from available literature to develop the MARS model with a total of seven variables that covered various geometrical and material properties including the width of rectangular steel tube (B), the depth of rectangular steel tube (H), the wall thickness of steel tube (t), the length of column (L), cylinder compressive strength of concrete (f'c), yield strength of steel (fy), and the load eccentricity (e). The proposed model is a combination of the MARS algorithm and the grid search cross-validation technique (abbreviated here as GS-MARS) in order to determine MARS' parameters. A new explicit formulation was derived from MARS for the mentioned input variables. The GS-MARS estimation accuracy was compared with four available mathematical methods presented in the current design codes, including AISC, ACI-318, AS, and Eurocode 4. The results in terms of criteria indices indicated that the MARS model was much better than the available formulae.

Development of a Gas Mixing System for Controlled Atmosphere(CA) Chambers

  • Yun, Hong-Sun;Lee, Hyun-Dong;Lee, Won-Ock;Chung, Hun;Cho, Kwang-Hwan
    • Agricultural and Biosystems Engineering
    • /
    • v.2 no.1
    • /
    • pp.31-36
    • /
    • 2001
  • Based on the viscous flow characteristics of gas through capillary tube, a simple and cheap gas mixing system was developed for controlling gas compositions in CA chambers. The gas flow rate through capillary tube had a linear relationship with pressure, (length)$^{-1}$ and (radius)$^4$ of capillary tube, which agreed well with Hagen-Poiseuille’s law. The relationship between flow rate and combined parameters was described as Q=0.000209724($\pi$ r$^4$P/$\mu$L) and the coefficient of determination was 0.9984. The developed system could control gas concentrations in CA chambers within $\pm$0.3% deviation compared to the preset concentrations. It was possible to predict the required time and required gas flow rate for exchanging the gs in CA chamber to a certain concentration of gas by using the mathematical model developed in this study.

  • PDF

Experimental Study on Heat Transfer Characteristics of HFC134a for Enhanced Tubes Used in a Flooded Evaporator (HFC134a 만액식 증발전열관 외부형상 변화에 따른 열전달 특성실험)

  • Yang, Seung-Woo;Lee, Young-Su;Jeong, Jin-Hee;Kang, Yong-Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.12
    • /
    • pp.971-976
    • /
    • 2006
  • The objectives of this paper are to study the characteristics of pool boiling heat transfer for enhanced tubes used in the evaporator of turbo chiller and to provide a guideline for optimum design of an evaporator using HFC134a. Three different enhanced tubes are tested at 4 different saturation temperatures. The wall super heated temperature difference ranges from $0.5^{\circ}C\;to\;3.5^{\circ}C$. The refrigerant, HFC134a evaporates on the outside of the tube while the chilled water flows inside the tube. This study provides experimental heat transfer coefficients for evaporation on the enhanced tubes. It is found that the turbo-II tube provides the highest heat transfer coefficient.

Effect of Micro Grooves on the Performance of Condensing Heat Transfer of the Micro Grooved Thermosyphons

  • Han, Kyu-Il;Cho, Dong-Hyun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.10 no.4
    • /
    • pp.184-191
    • /
    • 2002
  • This study concerns the performance of the condensing heat transfer performance of two-phase closed thermosyphons with plain copper tube and tubes having 50, 60, 70, 80, 90 internal micro grooves. Distilled water, methanol, ethanol have been used as the working fluid. The numbers of grooves and operating temperature have been investigated as the experimental parameters. Condensing heat transfer coefficients and heat flux are obtained from experimental data for each case of specific parameter. The experimental results are assessed and compared with existing correlations. The results show that working fluids, numbers of grooves are very important factors for the operation of thermosyphons. The working fluid with high latent heat such as water has a good heat transfer rate compared to methanol and ethanol. The relatively high rate of heat transfer is achieved when the thermosyphon with internal micro grooves is used compared to that with plain tube. Condensing heat transfer coefficient of grooved thermosyphon is 1.5∼2 times higher in methanol and 1.3∼l.5 times higher in ethanol compared to plain tube. The best condensation heat transfer performance is obtained for 60 grooves, and the maximum value of this case is 2.5 times higher than that of the plain tube.

A study of heat transfer characteristics on the Multi-pass Heat exchanger with Minichannel (다분지 미니 채널 열교환기의 액단상 열전달 특성에 관한 연구)

  • Im, Yong-Bin;Lee, Seung-Hun;Kim, Jeung-Hoon;Kim, Jong-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.357-362
    • /
    • 2006
  • This research focused on the multi-pass heat exchanger using the minichannel possessing the spring fin. An air-water was used as working fluid. The characteristics of liquid single phase heat transfer were verified. The compact heat exchanger (heat transfer area density : ${\beta}=2,146 m^2/m^3$), based on the shape of header(Top combining header), 63 minichannels ($D_i$ : 1.4 mm, L : 0.25 m) and the air side adopting the copper wire spring fin, was fabricated. The heat transfer area density of the air side was improved up to 161% when compared with the conventional fin-tube heat exchanger that adopts the heat transfer tube with the inner diameter of 5 mm. With regard to heat transfer performance, heat transfer rate per unit volume increased up to 142% when compared with the fin-tube heat exchanger adopting the heat transfer tube with the inner diameter of 5 mm.

  • PDF

The study on the measurement of formaldehyde in saliva and urine by GC-MS (가스크로마토그래프-질량분석기에 의한 타액 및 뇨 중 포름알데하이드 분석법 연구)

  • Shin, Ho-Sang;Ahn, Hye-Sil
    • Analytical Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.149-154
    • /
    • 2006
  • A gas chromatography-mass spectrometric method was developed for the determination of formaldehyde in urine and saliva. In a 20 mL glass tube, 0.2 mL of urine or saliva was taken. Further, 1.8 mL of 0.1 M HCl, 0.1 mL of 2,000 mg/L 2,4-dinitrophenyl hydrazine and $20{\mu}l$ of 500 mg/L acetone-$d_6$ as internal standard were added in the tube and sealed tightly with cap. The solution was shaken for 20 min at room temperature and extracted using 4 mL of toluene. The extract was concentrated and redissolved with $100{\mu}l$ of acetonitrile, and then measured by gas chromatography-mass spectrometer (selected ion monitoring). The detection limit was 2.0 ng/mL and 0.5 ng/mL in saliva and urine, respectively. The calibration curves showed good linearity with r = 0.997 and 0.998 for saliva and urine, respectively. The method was used to analyze formaldehyde in rat urine after oral exposure. The developed method may be use ful to the monitoring for formaldehyde exposure in human.

Flow Condensation Heat Transfer of R22, R134a, R407C, and R410A in Plain and Microfin Tubes (평관과 마이크로 핀관 내 R22, R134a, R407C, R410A의 흐름응축 열전달성능)

  • 조영목;박기호;송길흥;정동수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.8
    • /
    • pp.656-663
    • /
    • 2002
  • Flow condensation heat transfer coefficients (HTCs) of R22, R134a, R407C, and R410A were measured on horizontal plain and microfin tubes. The experimental apparatus was composed of three main parts; a refrigerant loop, a water loop and a water/glycol loop. The test section in the refrigerant loop was made of both a plain and a microfin copper tube of 9.52 mm outside diameter and 1.0 m length. The refrigerant was cooled by passing cold water through an annulus surrounding the test section. Tests were performed at a fixed refrigerant saturation temperature of $40^{\circ}C$ with mass fluxes of 100, 200, and 300 kg/$m^2s$. Test results showed that at similar mass flux the flow condensation HTCs of R134a were similar to those of R22 for both plain and microfin tubes. On the other hand, HTCs of R407C were lower than those of R22 by 11~l5% and 23~53% for plain and microfin tubes respectively. And HTCs of R410A were similar to those of R22 for a plain tube but lower than those of R22 by 10~21% for a microfin tube. In general, HTCs of a microfin tube were 2.0~3.0 times higher than those of a plain tube.

Impact of the spatial orientation of the patient's head, metal artifact reduction, and tube current on cone-beam computed tomography artifact expression adjacent to a dental implant: A laboratory study using a simulated surgical guide

  • Matheus Barros-Costa;Julia Ramos Barros-Candido;Matheus Sampaio-Oliveira;Deborah Queiroz Freitas;Alexander Tadeu Sverzut;Matheus L Oliveira
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.191-199
    • /
    • 2024
  • Purpose: The aim of this study was to evaluate image artifacts in the vicinity of dental implants in cone-beam computed tomography (CBCT) scans obtained with different spatial orientations, tube current levels, and metal artifact reduction algorithm (MAR) conditions. Materials and Methods: One dental implant and 2 tubes filled with a radiopaque solution were placed in the posterior region of a mandible using a surgical guide to ensure parallel alignment. CBCT scans were acquired with the mandible in 2 spatial orientations in relation to the X-ray projection plane (standard and modified) at 3 tube current levels: 5, 8, and 11 mA. CBCT scans were repeated without the implant and were reconstructed with and without MAR. The mean voxel and noise values of each tube were obtained and compared using multi-way analysis of variance and the Tukey test(α=0.05). Results: Mean voxel values were significantly higher and noise values were significantly lower in the modified orientation than in the standard orientation (P<0.05). MAR activation and tube current levels did not show significant differences in most cases of the modified spatial orientation and in the absence of the dental implant (P>0.05). Conclusion: Modifying the spatial orientation of the head increased brightness and reduced spatial orientation noise in adjacent regions of a dental implant, with no influence from the tube current level and MAR.