• Title/Summary/Keyword: L-Systems

Search Result 3,761, Processing Time 0.035 seconds

FUZZY L-CONVERGENCE SPACE

  • Min, Kyung-Chan
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1998.06a
    • /
    • pp.95-100
    • /
    • 1998
  • A notion of 'fuzzy' convergence of filters on a set is introduced. We show that the collection of fuzzy L-limit spaces forms a cartesian closed topological category and obtain an interesting relationship between the notions of 'fuzzy' convergence structure and convergence approach spaces.

  • PDF

Development of Bioreactor System for L-Tyrosine Synthesis Using Thermostable Tyrosine Phenol-Lyase

  • Kim, Do-Young;Rha, Eugene;Choi, Su-Lim;Song, Jae-Jun;Hong, Seung-Pyo;Sung, Moon-Hee;Lee, Seung-Goo
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.1
    • /
    • pp.116-122
    • /
    • 2007
  • An efficient enzyme system for the synthesis of L-tyrosine was developed using a fed-batch reactor with continuous feeding of phenol, pyruvate, and ammonia. A thermo- and chemostable tyrosine phenol-lyase from Symbiobacterium toebii was employed as the biocatalyst in this work. The enzyme was produced using a constitutive expression system in Escherichia coli BL21, and prepared as a soluble extract by rapid clarification, involving treatment with 40% methanol in the presence of excess ammonium chloride. The stability of the enzyme was maintained for at least 18 h under the synthesis conditions, including 75 mM phenol at pH 8.5 and $40^{\circ}C$. The fed-batch system (working volume, 0.51) containing 1.0 kU of the enzyme preparation was continuously fed with two substrate preparations: one containing 2.2 M phenol and 2.4 M sodium pyruvate, and the other containing 0.4 mM pyridoxal-5-phosphate and 4M ammonium chloride (pH 8.5). The system produced 130g/I of L-tyrosine within 30h, mostly as precipitated particles, upon continuous feeding of the substrates for 22 h. The maximum conversion yield of L-tyrosine was 94% on the basis of the supplied phenol.

A Study on the treatment efficiency of A2O Process coupled with Mesh Screening Reactor (Mesh Screening Reactor와 결합된 A2O 공정의 처리효율에 관한 연구)

  • Whang, Gye-Dae;Lim, Dong-Min
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.6
    • /
    • pp.705-714
    • /
    • 2008
  • Three Mesh Screenning Reactors (MSRs) were operated in three different modes to investigate the effect of the mesh opening size and the filtrate flux on the removal of particulate matters and the production of soluble organic matters. The mesh opening size was $82{\mu}m$ (Mode 1), $61{\mu}m$ (Mode 2) and $38{\mu}m$ (Mode 3), respectively, and each mode has three different filtrate flux; $0.47m^3/m^2/d$, $0.95m^3/m^2/d$ and $1.42m^3/m^2/d$, respectively. TSS removal efficiency of mode 1, 2, and 3 fed with 191 mgTSS/L was 27%, 36%, and 60%, respectively. The SCOD concentration of 91mg/L in influent for the mode 1, 2, and 3 increased to 117 mg/L, 127 mg/L, and 155 mg/L, respectively. For the all MSRs, there was no significant effect of filtrate flux on the removal of particulate matters and the production of soluble organic matters. However, the mesh opening size greatly affected the removal of particulate matters and the production of soluble organic matters in wastewater. Three parallel A2O processes consisting of anaerobic, anoxic and aerobic reactors maintaining mixed liquor suspended solids (MLSS) of 3,000 mg/L were operated to investigate the effectiveness of MSR on the removal efficiencies of the organic matters, nitrogen, and phosphorus; MSR influent was introduced to System 1 (183 mgTSS/L, 324 mgTCOD/L, 87 mgSCOD/L, 45.2 mgTKN/L, and 6.6 mgTP/L) and MSR efluent was introduced to System 2 and 3(72 mgTSS/L, 289 mgTCOD/L, 141 mgSCOD/L, 40.2 mgTKN/L, and 4.2 mgTP/L). HRTs of the anaerobic reactors in systems 1, 2 and 3 were 1 h, 1 h and 0.6 h, respectively and anoxic reactors were 2 h in all systems. HRTs of the aerobic reactors in systems 1, 2 and 3 were 5 h, 3 h and 3 h, respectively. TSS concentration in effluent of both system 2 and 3 is about 8 mg/L and lower than that of system 1 effluent. Despite higher TCOD loading and SCOD loading, both Systems 2 and 3 had a greater TCOD and SCOD removal efficiency at 91% and 92% than System 1 was at 88% and 82%, respectively. The nitrification efficiency for system 2 was greater than observed for System 1 (99% verses 97%). The denitrification efficiency for systems 1, 2 and 3 was 78%, 88% and 87%, respectively. System 2 and 3 showed about 12% higher TN removal efficiency than system 1 (85% verses 73%). The effluent TP concentration for system 2 was less than observed for system 1 and 3.

Some Subcategories of The Category IRe$l_{R}$(H) (범주 IRe $l_{R}$(H)의 부분범주)

  • K. Hur;H. W. Kang;J. H. Ryou;H. K. Song
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2003.05a
    • /
    • pp.29-32
    • /
    • 2003
  • We introduce the subcategories IRe $l_{PR}$ (H), IRe $l_{PO}$ (H) and IRe $l_{E}$(H) of IRe $l_{R}$(H) and study their structures in a viewpoint of the topological universe introduced by L.D.Nel. In particular, the category IRe $l_{R}$(H)(resp. IRe $l_{P}$(H) and IRe $l_{E}$(H)) is a topological universe eve, Set. Moreover, we show that IRe $l_{E}$(H) has exponential objects.ial objects.

  • PDF

A bi-directional transmission of Railway signal for mass information (다정보 철도신호의 양방향 전송)

  • Park, Jeong-Soo;Jang, Dae-Sik;Ahn, Sang-Kwon;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.632-634
    • /
    • 1996
  • In modern train systems, the high-speed and the high-density of train operation have been required. Effective train control systems need various information interchanged between the ground-site and on-board devices. So the systems are essential to the digital systems to admit lots of information and to raise the accuracy of transmission. In this paper, it is dealt with n bi-directional transmission of digital information between on-board devices and ground-site. Especially, this paper shows the experiment of bi-directional transmission of mass information by using transponder.

  • PDF

The Effects of DO, HRT, and Media Packing Ratio on Nitrogen Removal Efficiency in BCM-ASR System (고정상 담체를 충전한 활성슬러지 공정에서 DO농도와 HRT 및 담체 충전율 변화가 질소 제거효율에 미치는 영향)

  • Whang, Gye-Dae;Han, Bong-Seok
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.6
    • /
    • pp.659-669
    • /
    • 2008
  • Two sets of four parallel activated sludge reactors (ASRs) maintaining an MLSS of 3000 mg/L were operated to investigate the effect of DO, HRTs and bio-contact media (BCM) packing ratios on the removal efficiency of organic matters and nitrogen. Packing ratios of BCM to BCM-ASR systems 1, 2, 3, and 4 were 0% (suspended growth only), 10%, 15% and 20%, respectively. All systems were operated at an HRT of 4 hr, 6 hr, and 8 hr, respectively; DO concentration was maintained 0.5~1.0 mg/L and 1.5~2.0 mg/L for each HRT condition. In terms of TSS, TCODcr and SCODcr removal efficiency, all systems had a similar level of the removal efficiency under varied HRTs, and DO. But organic removal efficiency of systems with BCM was approximately 3~5% higher than systems without BCM at the same HRT and the DO. About the nitrification efficiency, with high DO (1.5~2.0 mg/L), as HRT (4 hr, 6 hr, 8 hr) or BCM packing ratio increased, the slight increment of nitrification efficiency was observed. However, under the low DO (0.5~1.0 mg/L), increase of BCM packing ratio and HRT resulted in large increase of the nitrification efficiency. At the same HRT and BCM packing ratio, the nitrification efficiency increased greatly with up to 15% as DO increased. When the HRT increased from 4hr to 8hr, the denitrification efficiency slightly increased by 5~10% only, under all DO conditions. Systems with BCM had higher denitrification efficiency, ranged 62.7~91.1% than systems without BCM showed 32.1~65.6%. And the increase in BCM packing ratio from 10% to 20% resulted in about 14~16% denitrification efficiency increment. BCM packing ratio showed great effect on the denitrification. The increase of the DO (from 0.5~1.0 mg/L to 1.5~2.0 mg/L) at the same HRT and BCM packing ratio resulted in slight decrease of denitrification efficiency with up to 7% for systems with BCM. But for systems without BCM, the denitrification efficiency decreased with up to 28%. In all system, the denitrification efficiency had more influence on the TN removal efficiency than nitrification efficiency. So, BCM packing ratio (0%, 10%, 15%, 20%) has greater effect on the TN removal than HRT and DO. The TN removal efficiency increased as packing ratio of BCM increased with up to 45%. As a result, the highest TN removal efficiency was observed 73.7% at the condition showed the highest denitrification efficiency that DO of 0.5~1.0 mg/L, an HRT of 8 hr, and 20% of BCM packing ratio was maintained.

L-upper Approximation Operators and Join Preserving Maps

  • Kim, Yong Chan;Kim, Young Sun
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.14 no.3
    • /
    • pp.222-230
    • /
    • 2014
  • In this paper, we investigate the properties of join and meet preserving maps in complete residuated lattice using Zhang's the fuzzy complete lattice which is defined by join and meet on fuzzy posets. We define L-upper (resp. L-lower) approximation operators as a generalization of fuzzy rough sets in complete residuated lattices. Moreover, we investigate the relations between L-upper (resp. L-lower) approximation operators and L-fuzzy preorders. We study various L-fuzzy preorders on $L^X$. They are considered as an important mathematical tool for algebraic structure of fuzzy contexts.

Robust $L_2-L_{\infty}$ Filter Design for Uncertain Time-Delay Systems via a Parameter-Dependent Lyapunov Function Approach (파라미터에 종속적인 리아푸노프 함수 기법에 의한 불확실 시간지연 시스템을 위한 강인한 $L_2-L_{\infty}$ 필터 설계)

  • Choi, Hyoun-Chul;Jung, Jin-Woo;Shim, Hyung-Bo;Seo, Jin-H.
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.177-178
    • /
    • 2008
  • An LMI-based method for robust $L_2-L_{\infty}$ filter design is proposed for poly topic uncertain time-delay systems. By using the Projection Lemma and a suitable linearizing transformation, a strict LMI condition for $L_2-L_{\infty}$ filter design is obtained, which does not involve any iterations for design-parameter search, any couplings between the Lyapunov and system matrices, nor any system-dependent filter parameterization. Therefore, the proposed condition enables one to easily adopt, with help of efficient numerical solvers, a parameter-dependent Lyapunov function approach for reducing conservatism, and to design both robust and parameter-dependent filters for uncertain and parameter-dependent time-delay systems, respectively.

  • PDF