• Title/Summary/Keyword: L-지표

Search Result 1,360, Processing Time 0.024 seconds

Analysis of Indicator Microorganism Concentration in the Rice Cultural Plot after Reclaimed Water Irrigation (하수처리수 관개후 벼재배 시험구에서 지표미생물 거동 분석)

  • Jung, Kwang-Wook;Jeon, Ji-Hong;Ham, Jong-Hwa;Yoon, Chun-Gyeong
    • Korean Journal of Ecology and Environment
    • /
    • v.37 no.1 s.106
    • /
    • pp.112-121
    • /
    • 2004
  • A study was performed to examine the effects of UV-disinfected reclaimed water on microorganism concentration during rice culture. Four treatments were used and each one was triplicated to evaluate the changes of microorganism concentrations: stream water irrigation (STR), biofilter effluent irrigation (BE), UV-disinfected water irrigation with dose of 6 mW ${\cdot}$ s $cm{-2}$ (UV-6), and UV-disinfected water irrigation with dose of 16 mW ${\cdot}$ s $cm{-2}$ (UV-16). The indicator microorganisms of interest were total coliform (TC), fecal coliform (FC), and E. coli. The biofilter effluent from 16-unit apartment sewage treatment plant was used as reclaimed water and flowthrough type UV-disinfection system was used. Concentrations of indicator microorganisms in the treatment plots ranged from $10^2$ to $10^5$ MPN/100 mL during 24 hours after irrigation in May and June, where initial irrigation water for transplanting reparation was biofilter-effluent without UV-disinfection. It implies that initial irrigation using only non-disinfected reclaimed water for puddling in paddy field can be health-concerned because of more chance of farmer's physical contact with elevated concentration of microorganisms. The concentrations of microorganisms varied widely with rainfall, and treatments using UV-disinfected water irrigation showed significantly lower concentrations than others and their levels were within the range of paddy rice field with normal surface water irrigation. The mean concentrations of STR and BE during growing season were in the range of 4 ${\times}\;10^3$ MPN/100 mL for TC, and 2${\times}\;10^3$ MPN/100 mL for FC and E, Coli, While mean concentrations of UV-S and UV-lS were less than 1${\times}\;10^3$ MPN/100 mL for all the indicator microorganisms. Overall, UV-disinfection was thought to be feasible and practical alternative for agricultural reuse of secondary level effluent in Korea.

Modification and Validation of an Analytical Method for Dieckol in Ecklonia Stolonifera Extract (곰피추출물의 지표성분 Dieckol의 분석법 개선 및 검증)

  • Han, Xionggao;Choi, Sun-Il;Men, Xiao;Lee, Se-jeong;Oh, Geon;Jin, Heegu;Oh, Hyun-Ji;Kim, Eunjin;Kim, Jongwook;Lee, Boo-Yong;Lee, Ok-Hwan
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.3
    • /
    • pp.143-148
    • /
    • 2022
  • This study was to investigate an analytical method for determining dieckol content in Ecklonia stolonifera extract. According to the guidelines of International Conference on Harmonization. Method validation was performed by measuring the specificity, linearity, precision, accuracy, limit of detection (LOD), and limit of quantification (LOQ) of dieckol using high-performance liquid chromatography-photodiode array. The results showed that the correlation coefficient of calibration curve (R2) for dieckol was 0.9997. The LOD and LOQ for dieckol were 0.18 and 0.56 ㎍/mL, respectively. The intra- and inter-day precision values of dieckol were approximately 1.58-4.39% and 1.37-4.64%, respectively. Moreover, intra- and inter-day accuracies of dieckol were approximately 96.91-102.33% and 98.41-105.71%, respectively. Thus, we successfully validated the analytical method for estimating dieckol content in E. stolonifera extract.

Design and Performance Verification of L1 Adaptive Flight Control Law Considering the Change of Center of Gravity for Unmanned Tailless Aircraft (무인 무미익 항공기의 무게중심 변화를 고려한 L1 적응제어 비행제어 법칙 설계 및 성능 검증)

  • Ko, Dong-hyeon;Kang, Ji-soo;Choi, Keeyoung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.2
    • /
    • pp.114-121
    • /
    • 2019
  • Tailless aircraft have advantages of low visibility compared to conventional aircraft, but drawback of poor stability as well which makes designing controller difficult. The controller design is more difficult, especially when the center of gravity moves due to store release or fuel consumption during flight. In this paper, an L1 adaptive controller is proposed as a way to overcome these problems. The reliability and performance of the controllers were verified by non-linear simulations. RPV Flying Quality Design criteria were used for design criteria. Using the simulation, it is shown that the adaptive controller maintains stability of the unmanned aircraft for sudden large change in the inertial properties. It is also shown that the calculation burden can be reduced when it is used with the gain scheduling method.

Physiological Activities of Hot Water Extract from Pine Bud (Pinus densiflora) (솔순 열수 추출물의 생리활성)

  • Cho, Eun-Kyung;Jeong, Bo-Rim;Choi, Young-Ju
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.11
    • /
    • pp.1573-1579
    • /
    • 2010
  • This research was performed to determine the antioxidant activity, nitrite scavenging activity, and its inhibitory activity on angiotensin converting enzyme (ACE), xanthine oxidase, $\alpha$-glucosidase, and elastase of hot water extract from pine bud (WPB). Antioxidant activity of WPB was measured by 2,2-diphenyl-1-picrylhydrazyl (DPPH) radical scavenging activity and superoxide dismutase (SOD)-like activity. DPPH radical scavenging activity and SOD-like activity of WPB were remarkably increased in a dose-dependent manner, and were about 71.4 and 85.4% at 2 mg/mL, respectively. The xanthine oxidase and ACE inhibitory activities were about 70.9 and 51.9% at 2 mg/mL of WPB, respectively. Nitrite scavenging activity of WPB was about 59.1, 53.8, and 39.5% on pH 1.2, 3.0, and 6.0 at 2 mg/mL, respectively. The WPB also showed elastase and $\alpha$-glucosidase inhibitory effects. These results revealed that pine bud have strong antioxidant activity and positive effects on the inhibition of xanthine oxidase, ACE, and elastase.

Discharge Characteristics of the Indicator Microorganisms of Combined Sewer Overflows (합류식 하수관거 월류수의 지표미생물 배출 특성)

  • Kim, Geonha
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.4
    • /
    • pp.627-635
    • /
    • 2006
  • Combined sewer overflow (CSOs) is a primary diffuse source degrading water quality of urban streams. In this study, CSOs caused by 5 different rainfall events at an urban watershed located in Daejeon city were monitored for the indicator microorganism concentrations. Event mean concentration (EMC) of the indicator microorganisms were: total coliform = $2.46{\times}10^6CFU/100mL$; fecal coliform = $1.01{\times}10^6CFU/100mL$; E.coli = $5.20{\times}10^5CFU/100mL$; and Fecal Streptococci = $6.08{\times}10^5CFU/100mL$. In addition, coliform concentrations were well correlated with suspended solid concentrations and the first flush effects were identified. Settling tests were carried out to estimate removal rate of indicator organisms by sedimentation from CSOs. As microorganisms are discharged in association with suspended solid, ten minutes of settlement can lower 44% of indicator microorganism leading.

A Study on Fluoride Contents in Surface and Ground Waters in Korea. (지표수 및 지하수중 불소 함량에 관한 연구)

  • Kim, Sung-Ja;Noh, Pyung-Ui;Bak, Young-Soo
    • Journal of Environmental Health Sciences
    • /
    • v.3 no.1
    • /
    • pp.9-12
    • /
    • 1976
  • A study was performed to find out the fluoride contents in surface and ground waters from June, 1973 to July, 1974. Water samples were collected from 53 surface and ground water sources. The results are as follows: 1. Out of 53 samples, the ground water of Hwaengsung had the highest fluoride contents (1.6 mg/l) and 13 samples did not. have fluoride at all. 2. The waters from Yoju (ground), Chongnung (ground) Hwaengsung (ground) and Namyang (ground) had optimum fluoride level (0.6~1.7mg/l) for the prevention of dental caries. 3. The ground waters had more fluoride contents than surface waters and the waters of coastal areas had less fluoride contents than those of inland. 4. The waters of Kangwon province had the most fluoride contents (mean 0.57mg/l) and the waters of Cheju do had the least fluoride contents (mean 0.06 mg/l)

  • PDF

Development and Application of Rainwater Collection Model by the Ground (우수의 지표 포집 모델의 개발 및 적용)

  • Lee, Dong-Kon;Lee, Kil-Soo;Wang, Chang-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.2
    • /
    • pp.173-180
    • /
    • 2005
  • In this study, quantity and quality of collected rainwater by the ground collection system were investigated and the Rainwater Collection Prediction Model was developed to predict the amount of collected rainwater. The quantity of collected rainwater in the collection system was 9516 L(38.2%) and the quantity of infiltrated rainwater in the collection system was 9946 L(40.2%) through $25m^2$ area for the study period, respectively. Average turbidity of collected rainwater in collection system was 2.2 NTU, and average turbidity of infiltrated rainwater in collection system was 2.3 NTU for study period, respectively. The predicted amount by the model and the actual collected amount were 9842.4 L and 9516 L, which were very close showing that prediction was excellent. The optimal rainwater storage tank volume was simulated with a certain consumption condition for various cities with different rainfall patterns.

Methacholine and adenosine 5'-monophosphate challenge tests in children with atopic asthma and with nonatopic asthma, and their relationships to blood eosinophil markers. (아토피성 천식 환아와 비아토피성 천식 환아에서 메타콜린과 아데노신 기관지 유발 검사의 비교 및 혈중 호산구 염증 지표와의 관련성)

  • Lee, Sun Hee;Kim, Do Kyun;Choi, Sun Hee;Koh, Young Yull
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.11
    • /
    • pp.1216-1222
    • /
    • 2006
  • Purpose : Though atopic and nonatopic asthma have different clinical manifestations, bronchial hyperresponsiveness (BHR) and airway inflammations are common characteristics of them. We investigated BHR to both methacholine and adenosine 5'-monophosphate (AMP), and their relationships with blood eosinophil markers in nonatopic asthma as well as atopic asthma. Methods : We studied 116 children (82 atopics; 34 nonatopics) with mild to moderate asthma. Methacholine and AMP challenge tests were performed and bronchial responsiveness was expressed as $PC_{20}$ (provocative concentration causing a 20 percent fall in $FEV_1$); blood eosinopil counts (ETCs) and serum eosinophil cationic protein (ECP) levels were gauged. Results : In atopics, 95.1 percent and 90.2 percent showed hyperreactivity to methacholine ($PC_{20}$<16 mg/mL) and AMP ($PC_{20}$<200 mg/mL), respectively. Meanwhile, in nonatopics, 94.1 percent and 52.9 percent displayed hyperreactivity to methacholine and AMP, respectively. The geometric mean of AMP $PC_{20}$ was lower in atopics (31.6 mg/mL) than in nonatopics (125.9 mg/mL); that of methacholine $PC_{20}$ was similar in the two groups. AMP $PC_{20}$ correlated with blood ETCs in both atopics(r=-0.30, P<0.01) and nonatopics (r=-0.57, P<0.01), and correlated with serum ECP levels (r=-0.23, P<0.01) in atopics, but not in nonatopics. Apart from AMP, methacholine $PC_{20}$ was not associated with blood eosinophil markers in either group. Conclusion : Atopics more frequently displayed BHR to AMP than nonatopics. Furthermore, BHR to AMP was associated with not only blood ETCs, but serum ECP levels in atopics but was correlated with only blood ETCs in nonatopics. Those results suggest that BHR to AMP reflects airway inflammation in asthma and is more related to atopy.

A study of estimation for excess attenuation of Noise propagated on the ground (지표면상을 전파하는 소음의 초과감쇠 산정방법에 관한 연구)

  • Oh, J.E.;Kim, D.G.;Yim, T.K.
    • The Journal of the Acoustical Society of Korea
    • /
    • v.7 no.2
    • /
    • pp.20-25
    • /
    • 1988
  • This study is to explain the characteristic of excess attenuation on the ground through the outdoors experiment about noise propagation and the reduced model experiment of acoustic. The outdoors experiment on the attenuation of noise propagation was tried with the small engine that had large acoustic output, and then it was conformed that there was relationship between the excess attenuation calculated by measurement from distance attenuation and Log(D/(Hs+Hr)). As a result, it was found that the attenuation of noise propogation depended upon the direction of the wind and frequency and was regressed in a straight line. And the numerical values of excess attenuation on the ground could be calculated by regarding Log(D/(Hs+Hr)) as a parameter with an airing resistance $\sigma$. It was found that when the mean square error between the excess attenuation calculated by measurement and the value calculated by a fomula $L=-20Log\mid1+(r_1/r_2)Qexp(ik, \bigtriangleup r)\mid$ about optional $\sigma$ was least, the optimal decision of u was made. As the characteristic of model is the model experiment on a reduced scale of 1 to 40, It was conformed that it corresponds enough with the measurement value with measuring the distance attenuation in the large anecoic chamber.

  • PDF