• Title/Summary/Keyword: Kwon Young

Search Result 15,777, Processing Time 0.043 seconds

A Dynamic Prefetch Filtering Schemes to Enhance Usefulness Of Cache Memory (캐시 메모리의 유용성을 높이는 동적 선인출 필터링 기법)

  • Chon Young-Suk;Lee Byung-Kwon;Lee Chun-Hee;Kim Suk-Il;Jeon Joong-Nam
    • The KIPS Transactions:PartA
    • /
    • v.13A no.2 s.99
    • /
    • pp.123-136
    • /
    • 2006
  • The prefetching technique is an effective way to reduce the latency caused memory access. However, excessively aggressive prefetch not only leads to cache pollution so as to cancel out the benefits of prefetch but also increase bus traffic leading to overall performance degradation. In this thesis, a prefetch filtering scheme is proposed which dynamically decides whether to commence prefetching by referring a filtering table to reduce the cache pollution due to unnecessary prefetches In this thesis, First, prefetch hashing table 1bitSC filtering scheme(PHT1bSC) has been shown to analyze the lock problem of the conventional scheme, this scheme such as conventional scheme used to be N:1 mapping, but it has the two state to 1bit value of each entries. A complete block address table filtering scheme(CBAT) has been introduced to be used as a reference for the comparative study. A prefetch block address lookup table scheme(PBALT) has been proposed as the main idea of this paper which exhibits the most exact filtering performance. This scheme has a length of the table the same as the PHT1bSC scheme, the contents of each entry have the fields the same as CBAT scheme recently, never referenced data block address has been 1:1 mapping a entry of the filter table. On commonly used prefetch schemes and general benchmarks and multimedia programs simulates change cache parameters. The PBALT scheme compared with no filtering has shown enhanced the greatest 22%, the cache miss ratio has been decreased by 7.9% by virtue of enhanced filtering accuracy compared with conventional PHT2bSC. The MADT of the proposed PBALT scheme has been decreased by 6.1% compared with conventional schemes to reduce the total execution time.

Development and Application of the High Speed Weigh-in-motion for Overweight Enforcement (고속축하중측정시스템 개발과 과적단속시스템 적용방안 연구)

  • Kwon, Soon-Min;Suh, Young-Chan
    • International Journal of Highway Engineering
    • /
    • v.11 no.4
    • /
    • pp.69-78
    • /
    • 2009
  • Korea has achieved significant economic growth with building the Gyeongbu Expressway. As the number of new road construction projects has decreased, it becomes more important to maintain optimal status of the current road networks. One of the best ways to accomplish it is weight enforcement as active control measure of traffic load. This study is to develop High-speed Weigh-in-motion System in order to enhance efficiency of weight enforcement, and to analyze patterns of overloaded trucks on highways through the system. Furthermore, it is to review possibilities of developing overweight control system with application of the HS-WIM system. The HS-WIM system developed by this study consists of two sets of an axle load sensor, a loop sensor and a wandering sensor on each lane. A wandering sensor detects whether a travelling vehicle is off the lane or not with the function of checking the location of tire imprint. The sensor of the WIM system has better function of classifying types of vehicles than other existing systems by detecting wheel distance and tire type such as single or dual tire. As a result, its measurement errors regarding 12 types of vehicle classification are very low, which is an advantage of the sensor. The verification tests of the system under all conditions showed that the mean measurement errors of axle weight and gross axle weight were within 15 percent and 7 percent respectively. According to the WIM rate standard of the COST-323, the WIM system of this study is ranked at B(10). It means the system is appropriate for the purpose of design, maintenance and valuation of road infrastructure. The WIM system in testing a 5-axle cargo truck, the most frequently overloaded vehicle among 12 types of vehicles, is ranked at A(5) which means the system is available to control overloaded vehicles. In this case, the measurement errors of axle load and gross axle load were within 8 percent and 5 percent respectively. Weight analysis of all types of vehicles on highways showed that the most frequently overloaded vehicles were type 5, 6, 7 and 12 among 12 vehicle types. As a result, it is necessary to use more effective overweight enforcement system for vehicles which are seriously overloaded due to their lift axles. Traffic volume data depending upon vehicle types is basic information for road design and construction, maintenance, analysis of traffic flow, road policies as well as research.

  • PDF

Comparison of Noise Power Spectrum Methodologies in Measurements by Using Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료시 전자포털영상장치를 이용한 잡음전력스펙트럼 방법론 측정비교)

  • Son, Soon-Yong;Choi, Kwan-Woo;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.99-105
    • /
    • 2016
  • The noise power spectrum (NPS) is one of the most general methods for measuring the noise amplitude and the quality of an image acquired from a uniform radiation field. The purpose of this study was to compare different NPS methodologies by using megavoltage X-ray energies. The NPS evaluation methods in diagnostic radiation were applied to therapy using the International Electro-technical Commission standard (IEC 62220-1). Various radiation therapy (RT) devices such as TrueBeam$^{TM}$(Varian), BEAMVIEW$^{PLUS}$(Siemens), iViewGT(Elekta) and Clinac$^R$ iX (Varian) were used. In order to measure the region of interest (ROI) of the NPS, we used the following four factors: the overlapping impact, the non-overlapping impact, the flatness and penumbra. As for NPS results, iViewGT(Elekta) had the higher amplitude of noise, compared to BEAMVIEW$^{PLUS}$ (Siemens), TrueBeam$^{TM}$(Varian) flattening filter, Clinac$^{R}$iXaS1000(Varian) and TrueBeam$^{TM}$(Varian) flattening filter free. The present study revealed that various factors could be employed to produce megavoltage imaging (MVI) of the NPS and as a baseline standard for NPS methodologies control in MVI.

Control of Common Scab of Potato Caused by Streptomyces spp. by Soil pH Adjustment and Crop Rotation (토양 pH 조절과 윤작에 의한 감자 더뎅이병 방제)

  • Kim, Jeom-Soon;Lee, Young-Gyu;Kwon, Min;Kim, Ju-Il;Lee, Gye-Jun;Lee, Jeong-Tae;Ryu, Jong-Soo
    • Research in Plant Disease
    • /
    • v.18 no.2
    • /
    • pp.117-122
    • /
    • 2012
  • In 2006, the effect of soil pH adjustment on control of common scab of potato caused by Streptomyces spp. was evaluated in the field. Soil with an original pH 5.7 was treated with sulfur of 42 kg/10a and calcium hydroxide of 81.6 kg/10a and 184.5 kg/10a to adjust pH 5.0, 6.0 and 6.5, respectively. Additionally, the effect of gypsum (522 kg/10a) on soil pH and disease severity was examined. The soil pH of sulfur treatment plot was continuously declined from 5.13 at tuber initiation time to 5.01 at harvest. The disease severity of sulfur treatment plot was relatively low (22.8%) and the marketable yield of that was high (90.5%). By contrast, the soil pHs treated with calcium hydroxide (81.6 kg/10a and 184.5 kg/10a) were increased (pH 6.06 and 6.49, respectively) at harvest. In addition, calcium hydroxide treatment plots showed higher disease severities (51.0% and 61.1%), and lower marketable yields (55.7% and 37.0%). Meanwhile, the soil pH of gypsum treatment plot was not changed until harvest, and the disease severity and the marketable yield were not significantly different from those of control. The effect of crop rotation was also evaluated with four crops such as welsh onion, soybean, corn and Chinese cabbage. These crops were planted in the infested field from 2005 to 2007, and potatoes were planted in the same field in 2008. The disease severities of potatoes produced after rotations with welsh onion, soybean, corn and Chinese cabbage for 3 years were 13.1%, 16.7%, 28.9% and 30.2%, respectively. However, the disease severity of 73.1% was shown in continuous cropping of potato for 3 years. In addition, similar effects were exhibited in the marketable yield. These results demonstrate that the adjustment of soil pH and crop rotation might be very useful tools to control common scab of potato.

Experiences with Emergency Percutaneous Cardiopulmonary Support in In-hospital Cardiac Arrest or Cardiogenic Shock due to the Ischemic Heart Disease (허혈성 심질환으로 인해 병원 내에서 발생한 심정지 혹은 심정지 혹은 심인성 쇼크에 있어서의 경피적 심폐 보조장치의 치료 경험)

  • Rhee Il;Kwon Sung-Uk;Cho Sung Woo;Gwon Hyeon-Cheol;Lee Young Tak;Park Pyo Won;Park Kay-Hyun;Lee Sang Hoon;Sung Kiick
    • Journal of Chest Surgery
    • /
    • v.39 no.3 s.260
    • /
    • pp.201-207
    • /
    • 2006
  • Background: Percutaneous cardiopulmonary support (PCPS) provides passive support of gas exchange and perfusion, allowing the use of other methods of care for organ recovery, and saves lives of patients with severe cardiopulmonary failure in a wide variety of clinical settings with a minimal risk of bleeding and need for chest re~ exploration. We summarized a single center's experiences with PCPS in patients with cardiogenic shock or cardiac arrest due to the ischemic heart disease. Material and Method: Among the 20 consecutive patients with cardiogenic shock or cardiac arrest from May 1999 to June 2005, Biopump (Medtronic, Inc, Minneapolis, MN) was used in 7 patients and the self-priming, heparin-coated circuit of EBS (Terumo, Japan) was applied to remaining 13 patients. Most of cannulations were performed percutaneously via femoral arteries and veins. The long venous cannulas of DLP (Medtronic inc. Minneapolis, MN) or the RMI (Edwards's lifescience LLC, Irvine, CA) were used with the arterial cannulae from 17 Fr to 21 Fr and the venous cannula from 21 Fr to 28 Fr. Result: The 20 consecutive patients who were severely compromised and received PCPS for the purpose of resuscitation were comprised of 13 cardiac arrests and 7 cardiogenic shocks in which by-pass surgery was performed in 11 patients and 9 ongoing PCls under the cardiopulmonary support. The mean support time on the PCPS was 38$\pm$42 hours. Of the 20 patients implanted with PCPS, 11 patients ($55\%$) have had the PCPS removed successfully; overall, 8 of these patients ($40\%$) were discharged from the hospital in an average surviving time for 27$\pm$17 days after removing the PCPS and survived well with 31$\pm$30 months of follow-up after the procedure. Conclusion: The use of PCPS appears to provide the hemodynamic restoration, allowing the survival of patients in cardiac arrest or cardiogenic shock who would otherwise not survive, and patients receiving PCPS had a relatively long-term survival.

Antioxidative, Antimicrobial and Cytotoxic activities of Fagopyrum esculentum $M{\ddot{o}}ench$ Extract in Germinated Seeds (발아 메밀 추출물의 항산화.항균활성 및 세포독성)

  • Hwang, Eun-Ju;Lee, Sook-Young;Kwon, Su-Jung;Park, Min-Hee;Boo, Hee-Ock
    • Korean Journal of Medicinal Crop Science
    • /
    • v.14 no.1
    • /
    • pp.1-7
    • /
    • 2006
  • This research was conducted to investigate the possibilities of usage of germinated-buckwheat (Fagopyrum esculentum $M{\ddot{o}}ench$) by examining antioxidative, antimicrobial and cytotoxic effects of extracts from different germinated root length of buckwheat. Antioxidant activity $(RC_{50})$ was shown higher in extracts of non-germinated seed $(50.41\;{\mu}g/mL)$ and root length 10 mm $(80.57\;{\mu}g/mL)$, 2 mm $(93.77\;{\mu}g/mL)$, 5 mm $(107.09\;{\mu}g/mL)$ than BHT $(163.96\;{\mu}g/mL)$ as a synthetic antioxidant. In antimicrobial activity, non-germinated and germinated seeds were formed inhibitory zone against S. aureus $(4{\sim}10\;mm)$, P. aeruginosa $(2{\sim}9\;mm)$ at the concentrations of $10{\sim}40\;mg/mL$ but B. subtilis, E. coli and S. typhimurium were not apparent antimicrobial activity. Extracts of germinated seed also decreased their antimicrobial activity compared to non-germinated seed extract. In addition, the growth of Calu-6 was inhibited of both 5 mm root length germinated and non-germinated seeds $(800\;{\mu}g/mL)$ as 95.12% and 87.15%, respectively, but these did not show any influence on cytotoxic effect against MCF-7 and Caco-2 cell lines. Extracts of 2 mm and 5 mm germinated seeds were also inhibited against Calu-6 and SNU-601 cell lines.

Effects of Recombinant Human Epidermal Growth Factor (rhEGF) on Experimental Radiation-Induced Oral Mucositis in Rats (Rat의 방사선 조사성 구내염에 대한 Recombinant Human Epidermal Growth Factor (rhEGF)의 효과)

  • Jung Kwon-Il;Kim Sun-Hee;Moon Soo-Young;Kim Yeon-Wha;Hong Joon-Pio;Kim Hyun-Sook;Lee Sang-Wook
    • Radiation Oncology Journal
    • /
    • v.24 no.1
    • /
    • pp.67-76
    • /
    • 2006
  • Purpose: Oral mucositis is a common toxicity of radiation or chemotherapy, which is used a treatment for head and neck cancer. We investigated effects of recombinant human epidermal growth factor (rhEGF) on radiation-induced oral mucositis in rat model. Materials and Methods: Spraque-Dawley rats (7 per group) exposed to a single dose of 25 Gy (day 0) on their head, except for one group, were randomly divided into un-treated, vehicle-treated, and two rhEGF-treated groups. Rats were topically applied with rhEGF (15 or $30{\mu}g/oral$ cavity/day) or vehicle to their oral mucosa. Survival rate of rats, weight changes, and food intakes were examined from day 0 to 18 after radiation. Histology study was performed from oral mucosa of rats at day 7 and 18 after radiation. Results: rhEGF-treated groups (15 or $30{\mu}g/oral$) showed all survival rate 33%, whereas un-treated and vehicle-treated groups showed all survival rate 0% at the end of experiment. rhEGF-treated groups statistically had less weight loss compared to vehicle-treated group from day 2 to 7 after radiation. Food intake of rats with rhEGF treatment turned to increase at day 14 after radiation. At 7 day after radiation, un-treated and vehicle-treated groups showed severe pseudomembraneous or ulcerative oral mucositis. On the other hand, rhEGF-treated groups had no more than cellular swelling and degeneration of epidermal cells in oral mucosa of rats. Conclusion: These results suggest that rhEGF has significantly positive effects on radiation-induced oral mucositis in rats. rhEGF display a therapeutic potential on a clinical level.

Intratumoral Administration of Dendritic Cells Combined with Hyperthermia Induces Both Local and Systemic Antitumor Effect in Murine Tumor Models (온열 요법 후 종양 내 주입한 수지상 세포의 국소 및 원격 항종양 효과)

  • Kwon Byung-Hyun;Kim Won-Taek;Kim Young-Kan;Kim Dong-Won
    • Radiation Oncology Journal
    • /
    • v.24 no.1
    • /
    • pp.51-57
    • /
    • 2006
  • Puroose: We examined whether intratumoral (i.t.) administration of dendritic cells (DCs) into a treated tumor could induce local and systemic antitumor effects in a mouse tumor model. Methods and Materials: C57BL/6 mice were inoculated s.c. in the right and left thighs with MCA-102 fibrosarcoma cells on day 0 and on day 7, respectively. On day 7, the tumors (usually 6 mm in diameter) on the right thigh were heated by immersing the tumor-bearing leg in a circulating water bath at $43^{\circ}C$ for 30 min; thereafter, the immature DCs were i.t administered to the right thigh tumors. This immunization procedure was repeated on days 7, 14 and 21. The tumors in both the right and left thighs were measured every 7 days and the average sizes were determined by applying the following formula, tumor $size=0.5{\times}(length+width)$. Cytotoxicity assay was done to determine tumor-specific cytotoxic T-lymphocyte activity. Results: Hyperthermia induced apoptosis and heat shock proteins (HSPs) in tumor occurred maximally after 6 hr. For the local treated tumor, hyperthermia (HT) alone inhibited tumor growth compared with the untreated tumors (p<0.05), and furthermore, the i.t. administered DCs combined with hyperthermia (HT + DCs) additively inhibited tumor growth compared with HT alone (p<0.05). On the distant untreated tumor, HT alone significantly inhibited tumor growth (p<0.05), and also HT + DCs potently inhibited tumor growth (p<0.001); however, compared with HT alone, the difference was not statistically significant. In addition, HT + DCs induced strong cytotoxicity of the splenocytes against tumor cells compared to DCs or HT alone. Conclusion: HT + DCs induced apoptosis and increased the expression of HSPs, and so this induced a potent local and systemic antitumor response in tumor-bearing mice. This regimen may be beneficial for the treatment of human cancers.

Nanomechanical Properties of Lithiated Silicon Nanowires Probed with Atomic Force Microscopy (원자힘 현미경으로 측정된 리튬화 실리콘 나노선의 나노기계적 성질)

  • Lee, Hyun-Soo;Shin, Weon-Ho;Kwon, Sang-Ku;Choi, Jang-Wook;Park, Jeong-Young
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.6
    • /
    • pp.395-402
    • /
    • 2011
  • The nanomechanical properties of fully lithiated and unlithiated silicon nanowire deposited on silicon substrate have been studied with atomic force microscopy. Silicon nanowires were synthesized using the vapor-liquid-solid process on stainless steel substrates using Au catalyst. Fully lithiated silicon nanowires were obtained by using the electrochemical method, followed by drop-casting on the silicon substrate. The roughness, derived from a line profile of the surface measured in contact mode atomic force microscopy, has a smaller value ($0.65{\pm}0.05$ nm) for lithiated silicon nanowire and a higher value ($1.72{\pm}0.16$ nm) for unlithiated silicon nanowire. Force spectroscopy was utilitzed to study the influence of lithiation on the tip-surface adhesion force. Lithiated silicon nanowire revealed a smaller value (~15 nN) than that of the Si nanowire substrate (~60 nN) by a factor of two, while the adhesion force of the silicon nanowire is similar to that of the silicon substrate. The elastic local spring constants obtained from the force-distance curve, also shows that the unlithiated silicon nanowire has a relatively smaller value (16.98 N/m) than lithiated silicon nanowire (66.30 N/m) due to the elastically soft amorphous structures. The frictional forces of lithiated and unlithiated silicon nanowire were obtained within the range of 0.5-4.0 Hz and 0.01-200 nN for velocity and load dependency, respectively. We explain the trend of adhesion and modulus in light of the materials properties of silicon and lithiated silicon. The results suggest a useful method for chemical identification of the lithiated region during the charging and discharging process.

Development of a High Heat Load Test Facility KoHLT-1 for a Testing of Nuclear Fusion Reactor Components (핵융합로부품 시험을 위한 고열부하 시험시설 KoHLT-1 구축)

  • Bae, Young-Dug;Kim, Suk-Kwon;Lee, Dong-Won;Shin, Hee-Yun;Hong, Bong-Guen
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.4
    • /
    • pp.318-330
    • /
    • 2009
  • A high heat flux test facility using a graphite heating panel was constructed and is presently in operation at Korea Atomic Energy Research Institute, which is called KoHLT-1. Its major purpose is to carry out a thermal cycle test to verify the integrity of a HIP (hot isostatic pressing) bonded Be mockups which were fabricated for developing HIP joining technology to bond different metals, i.e., Be-to-CuCrZr and CuCrZr-to-SS316L, for the ITER (International Thermonuclear Experimental Reactor) first wall. The KoHLT-1 consists of a graphite heating panel, a box-type test chamber with water-cooling jackets, an electrical DC power supply, a water-cooling system, an evacuation system, an He gas system, and some diagnostics, which are equipped in an authorized laboratory with a special ventilation system for the Be treatment. The graphite heater is placed between two mockups, and the gap distance between the heater and the mockup is adjusted to $2{\sim}3\;mm$. We designed and fabricated several graphite heating panels to have various heating areas depending on the tested mockups, and to have the electrical resistances of $0.2{\sim}0.5$ ohms during high temperature operation. The heater is connected to an electrical DC power supply of 100 V/400 A. The heat flux is easily controlled by the pre-programmed control system which consists of a personal computer and a multi function module. The heat fluxes on the two mockups are deduced from the flow rate and the coolant inlet/out temperatures by a calorimetric method. We have carried out the thermal cycle tests of various Be mockups, and the reliability of the KoHLT-1 for long time operation at a high heat flux was verified, and its broad applicability is promising.