• 제목/요약/키워드: Korean water

검색결과 67,382건 처리시간 0.079초

상수도관망 시스템의 부식제어를 위한 수질모니터링 (Water Quality Monitoring for Corrosion Control in Waterworks System)

  • 이현동;곽필재;이지은;김영관
    • 상하수도학회지
    • /
    • 제23권1호
    • /
    • pp.77-87
    • /
    • 2009
  • In existing systems, the best method inhibiting corrosion control in water distribution systems is to reduce water corrosiveness. Water corrosion can be decreased by controlling water quality through simple water treatment in treatment plants. On this research, we study the characteristics of tab water qualities in domestic areas, assessment of corrosive water quality and the method of water quality monitoring. This review presents the method of water quality monitoring which is the most applicable. Monitoring for corrosion control in waterworks system is the most proper method; It can prevent serious accidents economically and reduce civil appeals. Surely we should assess corrosive water quality in tab water, and introduce water treatment methods to control corrosive water quality before monitoring for corrosion. According to a lot of researches, it has been proved that simple water treatments can reduce the pipe corrosion. In this review we should indicate that we do not control of the corrosive water quality due to domestic conditions, we should monitor the water quality basically. Therefore, we recognize how the existing water quality can cause problems on pipeline corrosion, how to deal with it. Then it will be possible to apply water quality monitoring for corrosion control in water distribution system. Monitoring for corrosion control can be expressed by LI index, it is already known in literatures. This review presents more simple method than existing methods than existing ones we expect to apply these methods to SCADA in the future.

수요관리에 의한 물수급변화 분석 (A Study of Water Budget Analysis According to The Water Demand Management)

  • 서재승;이동률;최시중;강성규
    • 대한환경공학회지
    • /
    • 제33권11호
    • /
    • pp.797-803
    • /
    • 2011
  • 본 연구에서는 물 사용관련 주요 지표인 1인1일 급수량을 이용하여 수요관리 추진 결과 분석 및 절감량을 산정하고, 수요관리를 통하여 발생하는 절감량을 물 수급전망에 연계할 수 있는 시스템을 개발하였다. 1인1일 급수량 분석결과 상수도 여건이 열악한 지자체는 상수도 보급 개선이 선행되어야 하며, 장래용수수요량 추정시에도 이를 고려하여야 할 것으로 판단된다. 금강권역을 대상으로 수요관리 절감량을 산정하고 K-WEAP (Korea-Water Evaluation And Planning System)을 이용하여 물수지분석을 수행한 결과 하천유량 변화 및 지하수와 저수지저수량 증가를 확인하였으며, 이는 다른 용도로 활용 가능하다고 판단된다.

국내 복류수 및 강변여과수 취수시설의 오염물질 제거특성에 관한 연구 (A study on pollutants removal characteristics of domestic riverbed filtration and riverbank filtration intake facilities)

  • 정찬우;이선익;신성우;송창현;조부근;최재원
    • 상하수도학회지
    • /
    • 제37권5호
    • /
    • pp.281-288
    • /
    • 2023
  • This study was performed to evaluate the pollutants removal characteristics of two types of RBFs(Riverbank filtration, Riverbed filtration) intake facilities installed in Nakdong River and in Hwang River respectively. The capacity of each RBF is 45,000 m3/d for riverbank filtration intake facility and 3,500 m3/d for riverbed filtration intake facility. According to data collected in the riverbank filtration site, removal rate of each pollutant was about BOD(Biochemical Oxygen Demand) 52%, TOC(Total Organic Carbon) 57%, SS(Suspended Solids) 44%, Total coliforms 99% correspondingly. Furthermore, Microcystins(-LR,-YR,-RR) were not found in riverbank filtered water compared to surface water in Nakdong River. DOC(Dissolved Organic Carbon) and Humics which are precursors of disinfection byproduct were also reported to be removed about 59% for DOC, 65% for Humics. Based on data analysis in riverbed filtration site in Hwang River, removal rate of each contaminant reaches to BOD 33.3%, TOC 38.5%, SS 38.9%, DOC 22.2%, UV254 21.2%, Total coliforms 73.8% respectively. Additionally, microplastics were also inspected that there was no obvious removal rate in riverbed filtered water compared to surface water in Hwang River.

춘천지역 일부 주민들의 먹는물 중 미량금속 및 무기 음이온에 대한 노출 (Exposure of Selected Chuncheon Residents to Trace Metals and Inorganic Anions in Drinking Water)

  • 김희갑;송진아;송병열
    • Environmental Analysis Health and Toxicology
    • /
    • 제24권4호
    • /
    • pp.293-301
    • /
    • 2009
  • This study was conducted to investigate the distribution of the concentrations of selected trace metals and inorganic anions in five types of drinking water samples (mineral spring water, well water, small community water, municipal tap water, and commercial mineral water) collected from Chuncheon, Gangwon-do in 2007. Forty four samples were analyzed for five metals and five anions using an atomic absorption spectrometer and an ion chromatograph, respectively. Arsenic (As) and nitrate (${NO_3}^-$) concentrations in some groundwater samples did not meet the future (10 ${\mu}g/L$) and current (44 mg/L) Korean drinking water standards, respectively. On the other hand, any municipal tap water samples, the sources of which were lake surface water, satisfied the Korean standards. Human health risk assessment results showed that arsenic in all types of water, especially groundwater including commercial mineral water, may pose both noncarcinogenic and carcinogenic effects on the residents. It is concluded that groundwater is not safe drinking water any longer and that a national survey and follow-up measures need to be taken.

The economic value of water in Korean manufacturing industry

  • Ku, Se-Ju;Yoo, Seung-Hoon
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2010년도 학술발표회
    • /
    • pp.447-451
    • /
    • 2010
  • It is quite important for manufacturing firms to stably secure water, because industrial water is used for a variety of purposes as one of the important inputs in the production process. Despite the significance of industrial water use and the increase of industrial water demand, relatively little has studied regarding the industrial water use in Korea. This paper employs the marginal productivity approach in order to estimate the economic value of water in Korean manufacturing industry, and we use the information of 53,912 factories surveyed in 2003. The result of the likelihood ratio test shows that Trans-log is an appropriate model for estimating the data of this study. In Trans-log function model, the industry-wide output elasticity of water is 0.0104, and the marginal value is KRW 1,156 per ton. The estimated values differ across the sectors and these values range from the high value of about KRW 13,760 per ton in the transportation equipment sector to low values of KRW 428 per ton in the precision instrument sector. The research provides useful information to help policy-makers in developing and implementing more appropriate policies regarding the management and distribution of water resources by estimating the value of water resources by sector. In addition, Korean government enables the drafting of future water pricing scenarios based on the estimated value information.

  • PDF

음용수질 기준과 관리방안 (Recent Development of Drinking Water Quality Standard and its Application)

  • 권숙표
    • 환경위생공학
    • /
    • 제7권2호
    • /
    • pp.83-94
    • /
    • 1992
  • Recently water demand is increasing as the industry prospers. The increase of water demand is followed by the increase of wastewater discharge which pollutes rivers and ground water extensively. These rivers, reservoirs and ground water are sources for drinking water and their contamination affects the quality of water supply and other potable water. In Korea there are 776 water treatment plants which supply drinking water from main rivers or reservoirs. Rivers are the biggest water source for drinking water is being contaminated, the innovation of treatment process is needed. The construction and operation of water supply facilities is under the control of the Ministry of Construction and the water supply offices of cities and provinces. However, drinking water quality is under the control of the bureau of sanitation in the Ministry of Health and Social Affairs. There are 33 items in drinking water quality standards of Korea. Trihalomethanes, Selenium, Diazinone and other three of pesticides have been included lately, The Ministry of Health and Social Affairs is planning to enhance. the level of $VOC_S$(Vola-tile Organic Compounds) standard. Drinking water quality standard is the goal to protect the quality of supply water and ground water. In order to protect the source water from domestic or industrial water, technological improvement and adequate investment should be urgently made. The ultimate goal of drinking water quality is safety and health of consumers. The more stringent the standard are, the better the water quality will be. As the drinking water quality standards become more stringent this year, various and positive solutions by the authorities concerned must be prepared.

  • PDF

관개수온과 벼의 냉수피해 (Irrigation water temperature and cold water damage of paddy)

  • 정상옥;오창준
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1998년도 학술발표회 발표논문집
    • /
    • pp.14-21
    • /
    • 1998
  • In 1996, a cold-water damage occured in the paddy field at downstream of the Unmoon dam. To study the cause and the preventive measures of the cold-water damage a field study was performed during the growing season of 1997. Field measurements such as water temperatures at reservoir, irrigation canal and in the paddy field were made. As a result, there was no cold-water damage due to the right irrigation water management practice in 1997. The cold-water damage is passible to happen, however, and the preventive measures were provided.

  • PDF

Rural Water Supply from the Irrigation Reservoir

  • 김대철;박성기
    • 한국농공학회지
    • /
    • 제37권E호
    • /
    • pp.47-54
    • /
    • 1995
  • Irrigation water has been mainly used for paddy rice. Irrigated paddy land tends to be recently converted to land for green house, farm house, and rural-industrial complex. Consequently, demand of water for crops, domestic & industrial, rural recreations, small-scaled hydropower, livestocks, and environment in the rural area, so called rural water, is rapidly increasing. In order to supply rural water, water in the existing irrigation reservoir could be enlarged by repairment of irrigation canal and reinforcement of irrigation reservoir, and be saved by the operation rule curve, utilization of dead water, and balanced storage management.

  • PDF