• Title/Summary/Keyword: Korean medical hospital

Search Result 17,988, Processing Time 0.047 seconds

Shielding Capability Evaluation of Mobile X-ray Generator through the Production assembled Shield (일체형 방어벽 제작을 통한 이동형 엑스선 발생기의 차폐능 평가)

  • Kim, Seung-Uk;Han, Byeoung-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.895-908
    • /
    • 2018
  • As modern science is developed and advanced, examination and number of times using radiation are increasing daily. General diagnostic X-ray generator is installed on stationary form, But X-ray generator was developed because patient who is in the intensive care unit, operation room, emergency room can not move to general x-ray room. What we examine patient by x-ray generator is certainly necessary, So patient exposure is inevitable. but reducing radiation exposure is highly important matter about radiation technology, guardian, patient in the same hospital room, nurse etc. For this reason, rule regarding safety control of diagnostic x-ray generator revised for radiation worker, patient and protector proclaim that mobile diagnostic x-ray shield must placed in case of examine different location excluding operation room, emergency room, intensive care unit. But, radiogical technologist is having a lot of difficulties to examine with mobile x-ray generator, diagnostic x-ray shield partition, image plate and lead apron. So, when we use x-ray generator, we manufacture shield tools can be attached to the mobile x-ray generator On behalf of x-ray shield partition and conduct analysis and in comparison to part of body and distribution of dose rate and find way to reduce radiation exposure through distribution of dose rate of patient within the radiogical technologist, medical team. Mobile x-ray generator aimed at SHIMADZU inc. R-20, We manufactured equipment for shielding x-ray scattered x-ray by installing shielding wall from side to side based on support beam on the mobile x-ray generator. Shielding wall when moving can be folded and designed to expand when examine. Experiment measured five times in each by an angle for dose rate of eyes, thyroid, breast, abdomen and gonad on exposure condition of upper and lower extremity, chest, abdomen which is examined many times by mobile x-ray generator. We used dosimeter RSM-100 made by IJRAD and measured a horizontal dose rate by body part. The result of an experiment, shielding decreasing rate of the front and the rear showed 77 ~ 98.7%. Therefore using self-production shielding wall reduce scattered x-ray occurrence rate and confirm can decrease exposure dose consequently. Therefore, through this study, reduction result which is used shielding wall of self-production will be a role of shielding optimization and it could be answer about reduction of medical exposure recommended by ICRP 103.

Nutritional Status of Intensive Care Unit Patients According to the Referral to the Nutrition Support Team and Compliance with the Recommendations (영양집중지원팀 자문 의뢰 및 순응 여부에 따른 중환자실 환자의 영양상태 비교)

  • Sohn, Yunjin;Hyun, Taisun
    • Korean Journal of Community Nutrition
    • /
    • v.27 no.2
    • /
    • pp.121-131
    • /
    • 2022
  • Objectives: This study aimed to examine the effectiveness of the intervention of the nutrition support team (NST) on the nutritional status of critically ill patients. Methods: The medical records of 176 adult patients who were admitted to the intensive care unit and received enteral or parenteral nutrition for more than 7 days were retrospectively analyzed. The patients were classified into the NST and non-NST groups according to whether they were referred to the NST or not. The NST group was further classified into the compliance and non-compliance groups depending on their compliance with the NST recommendations. Results: The NST referral rate was 56.8%, and the rate of compliance with the NST recommendations was 47.0%. Significantly higher energy and protein were provided to the NST and the compliance groups than to the non-NST and the non-compliance groups. The proportion of patients who reached the target calories after the initiation of enteral nutrition was significantly higher in the NST and the compliance groups than in the non-NST and the non-compliance groups. The serum albumin and hemoglobin levels significantly decreased in every group, but the changes were significantly lower in the compliance group. The nutritional status at discharge from the intensive care unit compared to the status at admission was significantly worse in the NST, non-NST, and non-compliance groups. However, the status was maintained in the compliance group. The length of stay in the intensive care unit was significantly shorter in the compliance group. Conclusions: Compliance with the NST recommendations was found to provide more calories and protein and prevent the deterioration of the nutritional status of critically ill patients. Therefore, effective communication between medical staff and the NST from the early stages of admission to the intensive care unit is needed to improve referrals to the NST and compliance with the recommendations.

Analysis of Bone Mineral Density of Ankle Fracture Patients (족관절 골절 환자의 골밀도 분석)

  • Kim, Tae Hyung;Lee, Jae Hyung;Park, Seung-Hwan
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.4
    • /
    • pp.334-340
    • /
    • 2021
  • Purpose: This study analyzed the bone mineral densities of the lumbar vertebrae and femurs of patients with ankle fractures to determine the correlation between ankle fractures and osteoporosis. Materials and Methods: From April 2002 to July 2014, one hundred consecutive ankle fracture patients with bone mineral density tests performed within post-traumatic one year were enrolled. The patients were divided into three age groups according to their age at the time of injury (group 1: <50, group 2: 50-69, group 3: ≥70). The types of ankle fractures were classified into unimalleolar, bimalleolar and trimalleolar fractures. The bone mineral density was analyzed using the T score, Z score, absolute value (g/cm2) of the lumbar spine (L1-L4), femur neck, femur intertrochanter, and total femur. Results: There were 3.2 times more females with ankle fractures than males, and the prevalence of osteoporosis according to age group was 0% in the group under 50 years, 24.2% in the 50 to 69-year-old group, and 15% in the group over 70 years. Osteoporosis was found in 30% of patients with a trimalleolar fracture in the 50 to 69-year-old group. In all patient groups, a lower age indicated a higher frequency of unimalleolar fractures. The relationship between the bone mineral density and the type of fracture is that the frequency of trimalleolar fracture increased with decreasing T score of the lumbar vertebrae and the absolute value of bone mineral density (g/cm2) and the Z score of the femur neck, but there were no other indicators. Conclusion: Among the 100 patients with ankle fractures, females were more common than males, because osteoporosis was less severe in males. The incidence of unimalleolar fracture was higher than that of trimalleolar fracture. On the other hand, the correlation between the ankle fractures and the bone mineral density of the femur and lumbar spine was not significant.

Factors Affecting Physicians who will be Vaccinated Every Year after Receiving the COVID-19 Vaccine in Healthcare Workers (의료종사자의 COVID-19 예방 백신 접종받은 후 향후 매년 예방접종 의향에 미치는 요인)

  • Hyeun-Woo Choi;Sung-Hwa Park;Eun-Kyung Cho;Chang-hyun Han;Jong-Min Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.2
    • /
    • pp.257-265
    • /
    • 2023
  • The purpose of this study was to vaccinate every year according to the general characteristics of COVID-19, whether to vaccinate every year according to the vaccination experience, whether to vaccinate every year according to knowledge/attitude about vaccination, and negative responses to the vaccinate every year In order to understand the factors affecting the vaccination physician every year by identifying the factors of Statistical analysis is based on general characteristics, variables based on vaccination experience, and knowledge/attitudes related to vaccination. The doctor calculates the frequency and percentage, A square test (-test) was performed, and if the chi-square test was significant but the expected frequency was less than 5 for 25% or more, a ratio difference test was performed with Fisher's exact test. Through multiple logistic regression analysis using variables that were significant in simple analysis, a predictive model for future vaccination and the effect size of each independent variable were estimated. As statistical analysis software, SAS 9.4 (SAS Institute Inc., Cary, NC, USA) was used, and because the sample size was not large, the significance level was set at 10%, and when the p-value was less than 0.10, it was interpreted as statistically significant. In the simple logistic regression analysis, the reason why they answered that they would not be vaccinated every year was that they answered 'to prevent infection of family and hospital guests' rather than 'to prevent my infection' as the reason for the vaccination. It was 11.0 times higher and 3.67 times higher in the case of 'for the formation of collective immunity of the local community and the country'. The adverse reactions experienced after the 1st and 2nd vaccination were 8.42 times higher in those who did not experience pain at the injection site than those who did not, 4.00 times higher in those who experienced swelling or redness, and 5.69 times higher in those who experienced joint pain. There was a 5.57 times higher rate of absenteeism annually than those who did not. In addition, the more anxious they felt about vaccination, the more likely they were to not get the vaccine every year by 2.94 times.

Effect of Fractionated X-ray Irradiation on Sprouted Barley Growth and Chlorophyll Concentration (X선의 분할조사가 새싹보리 생장과 클로로필 농도에 미치는 영향)

  • In Suck Park;Won-Jeong Lee;Sang-Bok Jeong
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1171-1178
    • /
    • 2023
  • In study, we investigated changes on growth and chlorophyll concentration on sprouted barley by fractionated X-ray irradiation (FXI). Group was divided into the control group (CG), 1-time irradiation group (30 Gy once), 2-time irradiation group (15 Gy 2 times), and 3-time irradiation group (10 Gy 3 times), and 20 grains were used per group. Experimental group (EG) was exposed by using linear accelerator (Clinac IS, VERIAN, USA), by 6 MV X-ray, SSD 100 cm, 18×10 cm2, 600 MU/min. Length was measured every day until 9th day, and chlorophyl was analyzed using spectrophotometer(uv-1800, shimadzu, japan) in 9th day. Data analysis was performed the One-way ANOVA using SPSS ver 26.0(Chicago, IL, USA). In the pre-germination irradiation group (Pre-GIG), the CG had greater length than the EG on all measurement days, and as the number of FXI increased, the length became shorter. In the post-germination irradiation group (Post-GIG), the length of the CG was statistically significantly greater than that of the EG on all measurement days, and as the number of FXI increased, the length also became longer. The chlorophyll concentration was higher in the Post-GIG than in the Pre-GIG, and chlorophyll concentrations of EG was higher in the Pre-GIG than in the CG, as well as and Post-GIG. In addition, the smaller the number of FXI, the higher the chlorophyll concentration in both groups. FXI was found to affect the growth and chlorophyll concentration of sprouted barley.

Effect of the Ayres Sensory Integration Intervention on the Motor Skills and Occupation Participation of Preschool Children with Attention-Deficit/Hyperactivity Disorder (Ayres의 감각통합중재가 학령전기 주의력결핍 과잉행동장애(ADHD) 성향 아동의 운동기능 및 작업참여에 미치는 영향)

  • Jung, Yun-Jin;Kang, Je-wook;Chang, Moon-young;Kim, Kyeong-Mi
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.22 no.1
    • /
    • pp.1-14
    • /
    • 2024
  • Objective : This study aimed to investigate the impact of Ayres' sensory integration (ASI) intervention on motor skills and occupational participation of preschool children with attention-deficit/hyperactivity disorder (ADHD). Method : Children with ADHD aged between 4 and 6 years who met the inclusion and exclusion criteria were randomly recruited through screening tests. The subjects were divided into an experimental group (10 subjects) and a control group (8 subjects). The instruments used were the Bruininks-Oseretsky test of motor proficiency-2 (BOT-2), Pediatric Evaluation of Disability Inventory (PEDI), and Goal Attainment Scale (GAS) to evaluate occupational participation. The subjects in the experimental group underwent individual sensory integration therapy according to the ASI principles for 40 minutes twice a week in a total of 16 sessions over eight weeks. The control group did not receive the ASI intervention. Data analysis was performed using the Mann-Whitney U test, chi-squared test, Wilcoxon signed-rank test, and Cohen's d test in SPSS 20.0. Results : The ASI experimental group had significantly higher scores in total motor composite, manual coordination, body coordination, strength, and agility in motor function than the control group (p<.05). The two groups did not differ significantly in terms of occupational participation (PEDI), but GAS scores for individual target activities were significantly higher in the experimental group than in the control group (p<.05). Conclusion : This study shows that the ASI intervention has positive effects on motor skills and occupation participation among preschool children with ADHD.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

Effect of combined exercise on metabolic bio-marker in overweight and obese children (복합운동이 과체중 및 비만 남자 초등학생의 대사적지표에 미치는 영향)

  • Kim, Hyun-Jun;Kim, Tae-Un;Lee, Sangyeoup;Shin, Goon-Soo;Kim, Young-Joo;Kim, Su-Yung
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.9
    • /
    • pp.946-951
    • /
    • 2006
  • Purpose : The purpose of this study was to demonstrate the effectiveness of combined exercise for 12 weeks on the adiponectin and obesity related variables in overweight and obese children. Methods : Eighteen children in 5th grade in a certain elementary school in Busan were recruited. They were all overweight or obese children(more than 85 percentile in body mass index). Nine children in the experimental group were given exercises consisting of walking and band resistant training for 12 weeks. Auxological data(including height, weight and body fat mass) and laboratory data (fasting blood sugar, insulin, adiponectin) were checked at baseline and at the 1 week, and at the 4 weeks and 12 weeks stages of their exercise program. Insulin resistance and sensitivity were evaluated indirectly using HOMA index and QUICKI index. Results : Adiponectin gradually decreased until the 4 weeks point and gradually increased thereafter to the starting level at the 12 weeks stage. Body weight, body mass index(BMI) and HOMA index significantly decreased more at the 1 week, 4 weeks, and 12 weeks stages in the experimental group than in the control group. Body fat mass significantly decreased at 12 weeks. The change of insulin was significantly correlated with changes of body weight and BMI. But there was no correlation between changes of adiponectin and changes of insulin. Conclusion : Exercise seems to effect the adiponectin concentration. And it might be assumed that exercise increases the adiponectin concentration if it is continued for long time(may be more than 12 weeks). More studies may be necessary to draw that conclusion.

Video-Assisted Thoracoscopic Surgery for Fibrinopurulent Empyema (섬유농성 농흉의 비디오 흉강경을 이용한 치료)

  • 손정환;모은경;지현근;김응중;신호승;신윤철
    • Journal of Chest Surgery
    • /
    • v.36 no.6
    • /
    • pp.404-410
    • /
    • 2003
  • Different treatment options are available according to the stage and duration of the empyema. Stage I empyema (exudate stage) is treated concurrently by the administration of appropriate antibiotics and chest tube drainage. Stage III empyema (organized stage) is considered for decortication through an open thoracotomy. However, the treatment of fibrinopurulent, stage II empyema remains controversial. Recently, debridement with the use of Video-Assisted Thoracoscopic Surgery (VATS) has been proposed for the treatment of stage II empyema. We analyzed and report our initial experience of 5 cases of stage II empyema, treated with the use of VATS. Material and Method: Between June 2001 and February 2002, 5 patients with fibrinopurulent empyema that did not respond to antibiotics, chest tube drainage or Percutaneous Catheter drainage (PCD), and instillation of fibrinolytic agent were treated by debridement and irrigation with the use of VATS. A CT scan was performed in all patients before the operation to confirm the diagnosis of loculated empyema and to detect additional lung parenchymal diseases. Result: All 5 patients underwent successful debridement and irrigation with the use of VATS and the chest tube was inserted properly. And no patients needed conversion to open thoracotomy. The ratio of sex was 4 : 1 (male : female), the mean age was 53 years old (range, 26~73 years), the mean operative time was 73.4 minutes (range, 52~95 minutes), the mean duration of postoperative chest tube placement was 12.4 days (range, 6~19 days), and the mean duration of postoperative hospital stay was 20.8 days (range, 10~36 days). In all patients, clinical symptoms such as pain and fever subsided and simple chest PA view revealed satisfactory lung expansion. No major postoperative complication was observed during the hospital course and no patient suffered from the recurrence of empyema in the follow-up period. Conclusion: We think that early operation with the use of VATS is safe and efficient for stage II empyema which did not respond to medical treatment(antibiotics and chest tube drainage), therefore, it can prevent stage II empyema from advancing to stage III, organized empyema.

Job Analysis for Role Identification of General Hospice Palliative Nurse (호스피스 완화 간호사 역할규명을 위한 직무분석)

  • Kim, Boon-Han;Choe, Sang-Ok;Chung, Bok-Yae;Yoo, Yang-Sook;Kim, Hyun-Sook;Kang, Kyung-Ah;Yu, Su-Jeong;Jung, Yun
    • Journal of Hospice and Palliative Care
    • /
    • v.13 no.1
    • /
    • pp.13-23
    • /
    • 2010
  • Purpose: This study was to identify the role of general hospice palliative nurse through job analysis (duties, task, and task elements). Methods: The sample consisted of 136 nurses or professors who were performing duties related to hospice care areas in Korea. A survey method was used, and the questionnaire included frequencies, criticality, and difficulties of task elements in job description by the DACUM method. Descriptive statistics were performed by using SPSS WIN 17.0. Results: The job description of general hospice palliative nurse was identified 8 duties, 36 tasks, and 137 task elements. As for the 8 duties, the average scores of frequency, criticality, and difficulty were 2.94, 3.66, and 2.80, respectively. The role of ‘pain assessment’ was the most important task element among frequency and criticality. The lowest score at the frequency and criticality were ‘manage public finance’ and ‘collect datum through diagnostic test & lab', respectively. Furthermore, the role of 'identify spiritual needs of patients and family' was the most difficult task, whereas the role of 'manage documents and information' was the least. Conclusion: In this study, we could recognize the reality of general hospice palliative nurse's performances. For general hospice palliative nurse, therefore, concrete practice guide lines of psychosocial and spiritual care, communication skills, and bereavement care with qualifying system are critically needed.