• Title/Summary/Keyword: Korean images

Search Result 18,442, Processing Time 0.044 seconds

Types and Site Characteristics of Rocks with Sinsun Relevant Place Name Morpheme ('신선(神仙)'을 지명소(地名素)로 하는 바위명의 유형과 입지특성)

  • Rho, Jae-Hyun;Park, Joo-Sung;Sim, Woo-Kyung
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.29 no.3
    • /
    • pp.61-77
    • /
    • 2011
  • This study focused on relevant rock names related to Sinsun(神仙) which had been settled as Taoist traces were combined with places. While interpreting major features of Sundoism relevant rocks, it also discussed types and places of rocks reflected in their names by considering distinct characteristics of landscape characters that ancestors viewed through the rocks or on the rocks. Conclusion of this study is summarized as follows. 1. Among the rock names related to Sinsun, the most frequently discovered one was Sinsunbawi(52) and followed by Sinsunbong(神仙峰: 38), Sinsundae(神仙臺: 31). Other than these, there were Gangsundae(降仙臺: 12), Sunyoodae (仙遊臺: 10) and Sasundae(四仙臺: 5). 2. In the name of Sinsundae, 'Dae(臺)' ascertains that it was located in greatly superb place in the aspects of viewpoint and appreciation where landscape superiority and overlook scenery were fair and outstanding. 3. Sinsunbong was named for a peak of mountain. At the same time, it implied a notion of worship with images of 'merging with sky' or 'looking up.' Most of time, Sinsunbong indicated the tallest rock in the mountain chain. 4. A significant number of Sinsunbong had names where legends of Sinsun's Go game or descent were originated from. It shows that 'Sinsun(仙) and Go game' used to be very important motives for folk etymology of Sinsun related rocks. Along with the Sinsundae, a number of Sinsunbawi were also turned out to exist in land and ocean with excellent marine view. 5. According to analysis of their altitudes and heights of the peaks where the rocks belong to, Sinsunbong, Sinsundae and Sinsunbawi were in order. It might indicate that the rocks were located on top of mountain or that Sinsunbong represented the mountain itself. Compared to this, Sinsundae was located in where distant panoramic views were overlooked. It was not necessarily to be in peak but in where with a great view like Taoist world. On the other hand, Sinsunbawi was located in where has fine scenery and great valley not so far from villages, which proved its name had been influenced by place feature not altitude. 6. Feature of rock with Sinsun related name is to comprise visual stability of worship object with close linkage to attitude of worshiper. Considering its deep connection with communicative method of worship object and worshiper, seemingly it was main factor to lead folk etymology of rocks with Sinsun related names. 7. Rock is an object with the greatest implication of Sinsun imagination and Sinsun rocks show most clearly the fact that Taoism, which used to be considered as inaccessible, had been actualized in a visual and realistic manner with the change of time.

A Brief Study on the characteristics of Image-Meaning theory focused on image in the early days of the Joseon Dynasty and SongMing period (송명역학과 조선전기역학의 상수위주적 상의관의 특징)

  • YOON, SEOKMIN
    • The Journal of Korean Philosophical History
    • /
    • no.43
    • /
    • pp.267-293
    • /
    • 2014
  • This paper is aimed at analyzing the characteristics of Image-Meaning theory focused on image in the early days of the Joseon Dynasty and SongMing period. Zhouyi' theory in the early days of the Joseon Dynasty was constructed on the basis of Zhouyi' theory of SongMing period. The characteristics of Image-Meaning theory in the early days of the Joseon Dynasty can be explained largely by two routes. One is the perspective of critical succession on Zhouyi'theory of focusing on meaning that led Chengyi(程?) and Yangwanli(楊萬裏). As the representative of this route, Gwongeun and Toegye not only asserted Image-meaning theory focused on meaning, but also developed a perspective of taking all the image and meaning. The other is the active succession and creative transformation about Image-Meaning theory of Tushuxue that led Chentuan(陳?) and Shaoyong(邵雍). As the representative of that route, Yulgok and Yeohun explained the schematic diagram of the universe of the universe by using methodology of Tushuxue. Furthermore, they actively succeed Shaoyong' Zhouyi theory to expand Image-Meaning theory focused on number. In addition, Cho, Haoyi(曺好益)described the propositions - "meaning is not out of image area, image equipped with meaning all, then there is no law of limitation in image adopted theory. Those propositions are opposed to Chengyi(程?) and Zhuxi(朱熹)' ZhouYi' theory.

A Study of YulGok Yi Yi's communicational I-Xue (율곡(栗谷) 이이(李珥)의 소통적(疏通的) 역학관(易學觀) 연구(硏究) - 책문(策文)을 중심(中心)으로 -)

  • Seo, Geun Sik
    • The Journal of Korean Philosophical History
    • /
    • no.25
    • /
    • pp.197-222
    • /
    • 2009
  • In this treatise, the researcher closely examined the I-Xue(易學) compiled and edited by YulGok(栗谷) with a focus on the concept, namely Communication(疏通). I-Xue(易學) compiled by YulGok(栗谷) adopted the discourses of I-Xue(易學) or changes in the Song Dynasty of ancient China, and engrafted his own logics, dubbed Liqizhimiao(理氣之妙), thereunto. In YulGok(栗谷)'s I-Xue(易學), Liqizhimiao(理氣之妙) expresses a state of exchanging information and Communication(疏通), and, at this time, Communication(疏通) encompasses not only the meaning of communication between two heterogeneous factors but also the broader meaning of Communication(疏通) that embrace the Communication(疏通) between heaven and human beings. In his theories in relation to Tiyongyiyuan(體用一源) and Heluoxiangshulun(河洛象數論), YulGok(栗谷) also applied the logic of Communication(疏通). Although YulGok(栗谷) admits the general theory that substance and function have the same source, which understands principle and phenomenon as two forms of existence, he tried to place emphasis more on the aspect of Communication(疏通) by interpreting Li(理) and Xiang(象) in terms of the issues concerned with Li(理) and Jian(踐). In his theory concerned with Magic Squares and Circles, Images and Numbers, such a standpoint is being applied likewise. By emphasizing the fact that Hetu("河圖") may turn out to be Luoshu("洛書"), and vice versa, YulGok(栗谷) stressed that there are communicative relations that are required in order to communicate ideas to one another. In YulGok(栗谷)'s I-Xue(易學), the logic of Communication(疏通) is culminated with the discourse of Tianrenjiaoyu(天人交與). YulGok(栗谷), in his book Ishuce(易數策), uses such expression as Tianrenjiaoyuzhimiao(天人交與之?), and, at this time, he used this expression bearing Liqizhimiao(理氣之妙) in mind. The reason for using the expression, such as Jiaoyu(交與), in lieu of Heyi(合一) is that YulGok(栗谷) tried to emphasize such relations as that heaven and humans are required for interrelated relationship. Tianrenjiaoyu(天人交與) is an expression to indicate the close relationship between heaven and human beings, meanwhile, however, YulGok(栗谷) puts more emphasis on human efforts than those that of heaven. The reason for introducing human as the subjective figure in the Tianrenjiaoyu(天人交與) is that YulGok(栗谷) tried to stress practical efforts of humans.

A Study on the Quality Control of Transvaginal Ultrasound Transducer using ATS-539 Ultrasound Phantom (ATS-539 초음파 팬텀을 이용한 경질 초음파 검사용 탐촉자의 정도관리에 대한 연구)

  • Park, Ji Hye;Heo, Yeong Cheol;Kim, Yon min;Han, Dong Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.463-472
    • /
    • 2021
  • Demand for examinations using transvaginal transducer with high frequencies is increasing to observe pelvic organs in gynecological ultrasound tests. However, the quality control of the replacement probe in clinical trials is not properly implemented and the evaluation criteria have not been established. Therefore, 58 transvaginal transducers and 20 convex transducers were applied to the ATS-539 ultrasound phantom for 20 ultrasound devices currently in clinical use to obtain their respective images and measure them quantitatively and qualitatively. For quantitative measurements, vertical measurement, horizontal measurement, and focal zone and qualitative measurements, dead zone, axial·lateral resolution, sensitivity, functional resolution, gray scale·dynamic range were performed. Quantitative statistical analysis showed significant differences between the two transducers in the lateral measurement and local area (p<0.05). qualitative comparative analysis showed differences in sensitivity and functional resolution. This occurs due to the difference in frequency between transducers and the transducer's injection geometry. Based on the above experiments, the tolerance for horizontal measurement is raised to 10% (±8 mm), the tolerance for sensitivity is observed up to 6 cm deep, which is 12 cm deep,which is the level of the third quartile (75%). The permissible range of functional resolution is up to 6 (12 cm), 6 (12 cm), 11 (11 cm), 9 (9 cm), 6 (6 cm) target, which is the level of the third quartile (75%). It is considered reasonable to adjust the depth of targets in gray scale·dynamic range to measure at a depth of 2 cm, which is 50% of the depth of 4 cm. As above, the criteria for evaluating the quality of transvaginal transducer for use in the past have been proposed and it is expected that this study will be used as a basic data for the production of phantom exclusively for transvaginal transducer in the future.

Analysis on Types of Scientific Emoticon Made by Science-Gifted Elementary School Students and their Perceptions on Making Scientific Emoticons (초등 과학영재 학생의 과학티콘 유형 및 과학티콘 만들기에 대한 인식 분석)

  • Jeong, Jiyeon;Kang, Hunsik
    • Journal of The Korean Association For Science Education
    • /
    • v.42 no.3
    • /
    • pp.311-324
    • /
    • 2022
  • This study analyzed the types of scientific emoticons made by science-gifted elementary school students and their perceptions on making scientific emoticons. To do this, 71 students from 4th to 6th graders of two gifted science education center in Seoul were selected. Scientific emoticons made by the students were analyzed according to the number and types. Their perceptions on making scientific emoticons were also analyzed through a questionnaire and group interviews. In the analyses for types of text in the scientific emoticons, 'word type' and 'sentence type' were made more than 'question and answer type'. And the majority of students made more 'pun using pronunciation type' and 'mixed type' than other types. They also made more 'graphic type' and 'animation type' than 'text type' in the images of the scientific emoticons. In the analyses for the information of the scientific emoticons, 'positive emotion type' and 'negative emotion type' of scientific emoticons were made evenly. The students made more 'new creation type' than 'partial correction type' and 'entire reconstruction type'. They also used scientific knowledge that preceded the knowledge of science curriculum in their grade level. The scientific knowledge of chemistry was used more than physics, biology, earth science, and combination field. 'Name utilization type' was more than 'characteristic utilization type' and 'principle utilization type'. Students had various positive perceptions in making scientific emoticons such as 'increase of scientific knowledge', 'increase of various higher-order thinking abilities', 'ease of explanation, use, memory, and understanding of scientific knowledge', 'increase of fun, enjoyment, and interest about science and science learning', and 'increase of opportunity to express emotions'. They were also aware of some limitations related to 'difficulties in the process of making scientific emoticons', 'lack of time', and 'limit that it may end just for fun'. Educational implications of these findings are discussed.

A Study on the Development and usefulness of the x/y Plane and z Axis Resolution Phantom for MDCT Detector (MDCT 검출기의 x/y plane과 z축 분해능 팬텀 개발 및 유용성에 관한 연구)

  • Kim, Yung-Kyoon;Han, Dong-Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.1
    • /
    • pp.67-75
    • /
    • 2022
  • The aim of this study is to establish a new QC method that can simultaneously evaluate the resolution of the x/y plane and the z-axis by producing a phantom that can reflect exposure and reconstruction parameter of MDCT system. It was used with Aquilion ONE(Cannon Medical System, Otawara, Japan), and the examination was scanned using of 120 kV, 260 mA, and the D-FOV of 300 mm2. It produced new SSP phantom modules in which two aluminum plates inclined at 45° to a vertical axis and a transverse axis to evaluate high contrast resolution of x/y plane and z axis. And it changed factors such as the algorithm, distance from gantry iso-center. All images were reconstructed in five steps from 0.6 mm to 10.0 mm slice thickness to measure resolution of x/y plane and z-axis. The image data measured FWHM and FWTM using Profile tool of Aquarius iNtusion Edition ver. 4.4.13 P6 software(Terarecon, California, USA), and analysed SPQI and signal intensity by ImageJ program(v1.53n, National Institutes of Health, USA). It decreased by 4.09~11.99%, 4.12~35.52%, and 4.70~37.64% in slice thickness of 2.5 mm, 5.0 mm, and 10.0 mm for evaluating the high contrast resolution of x/y plane according to distance from gantry iso-center. Therefore, the high contrast resolution of the x/y plane decreased when the distance from the iso-center increased or the slice thickness increased. Additionally, the slice thicknesses of 2.5 mm, 5.0 mm, and 10.0 mm with a high algorithm increased 74.83, 15.18 and 81.25%. The FWHM was almost constant on the measured SSP graph for evaluating the accuracy of slice thickness which represents the resolution of x/y plane and z-axis, but it was measured to be higher than the nominal slice thickness set by user. The FWHM and FWTM of z-axis with axial scan mode tended to increase significantly as the distance increased from gantry iso-center than the helical mode. Particularly, the thinner slice thickness that increased error range compare with the nominal slice thickness. The SPQI increased with thick slice thickness, and that was closer to 90% in the helical scan than the axial scan. In conclusion, by producing a phantom suitable for MDCT detectors and capable of quantitative resolution evaluation, it can be used as a specific method in the management of research quality and management of outdated equipment. Thus, it is expected to contribute greatly to the discrimination of lesions in the field of CT imaging.

Comparative evaluation of dose according to changes in rectal gas volume during radiation therapy for cervical cancer : Phantom Study (자궁경부암 방사선치료 시 직장가스 용적 변화에 따른 선량 비교 평가 - Phantom Study)

  • Choi, So Young;Kim, Tae Won;Kim, Min Su;Song, Heung Kwon;Yoon, In Ha;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.89-97
    • /
    • 2021
  • Purpose: The purpose of this study is to compare and evaluate the dose change according to the gas volume variations in the rectum, which was not included in the treatment plan during radiation therapy for cervical cancer. Materials and methods: Static Intensity Modulated Radiation Therapy (S-IMRT) using a 9-field and Volumetric Modulated Arc Therapy (VMAT) using 2 full-arcs were established with treatment planning system on Computed Tomography images of a human phantom. Random gas parameters were included in the Planning Target Volume(PTV) with a maximum change of 2.0 cm in increments of 0.5 cm. Then, the Conformity Index (CI), Homogeneity Index (HI) and PTV Dmax for the target volume were calculated, and the minimum dose (Dmin), mean dose (Dmean) and Maximum Dose (Dmax) were calculated and compared for OAR(organs at risk). For statistical analysis, T-test was performed to obtain a p-value, where the significance level was set to 0.05. Result: The HI coefficients of determination(R2) of S-IMRT and VMAT were 0.9423 and 0.8223, respectively, indicating a relatively clear correlation, and PTV Dmax was found to increase up to 2.8% as the volume of a given gas parameter increased. In case of OAR evaluation, the dose in the bladder did not change with gas volume while a significant dose difference of more than Dmean 700 cGy was confirmed in rectum using both treatment plans at gas volumes of 1.0 cm or more. In all values except for Dmean of bladder, p-value was less than 0.05, confirming a statistically significant difference. Conclusion: In the case of gas generation not considered in the reference treatment plan, as the amount of gas increased, the dose difference at PTV and the dose delivered to the rectum increased. Therefore, during radiation therapy, it is necessary to make efforts to minimize the dose transmission error caused by a large amount of gas volumes in the rectum. Further studies will be necessary to evaluate dose transmission by not only varying the gas volume but also where the gas was located in the treatment field.

Evaluation of the usefulness of the method according to changes in patient breathing during chest 4D CT imaging (흉부 4D CT에서 호흡 변화에 대한 일시 중지 및 재개 방법의 유용성 평가)

  • Heo, Sol;Shin, Chung Hun;Jeong, Hyun Sook;Yoo, Soon Mi;Kim, Jeong Mi;Yun, In Ha;Hong, Seung Mo;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.47-54
    • /
    • 2021
  • Purpose : In order to evaluate the usefulness of clinical application of the Pause & Resume methods by comparing and analyzing the data stability and dose reduction effect when repeat scan assuming irregular breathing and using the Pause & Resume method during chest 4D CT using QuasarTM Phantom. Materials and Methods : Using the QuasarTM Phantom, set the breathing rate per minute to 15 BPM and 7.5 BPM, and set the S15 point as an irregular breathing section, and then placed OSLD to this point and use the Pause & Resume method to measure the dose of S15. CTDIvol, DLP, and ALARA-CT were used for comparative analysis of radiation dose between Pause & Resume method and Repeat-scan. In order to evaluate the stability and usability of the data applying the Pause & Resume method, the captured images were sorted by Advanced Workstation Volume Share7 and then sent to EclipseTM, the diameter and volume were analyzed by forming a contour on the iron ball in the QuasarTM Phantom Results : When using Pause & Resume, the dose of OSLD measurement increased by 1.97 times in the section of S15. As a result of image evaluation, the average value of all volumes measured with and without the Pause & Resume method at 15 BPM and 7.5 BPM was 15.2 cm3±0.5%.Allthemeasuredvaluesfor the radius of iron ball were 3.1 cm regardless of whether Pause & Resume method was used or not. In the case of using Pause & Resume, 33% decreased from the lowest DLP value and 38% decreased from the highest DLP value of repeat scan, and the effective dose also decreased 32.1% from the minimum value and 37.6% from the maximum value. Conclusion: Irradiation dose was increased by Pause & Resume method because of the repeat scan on the S15 site where assuming irregular breathing occurred, However Pause & Resume method led to a significant reduction in dose on overall scan range. It also proved the usefulness of clinical application of the Pause & Resume method as a result of similar diameters and volumes of iron ball measurement.

The Style and Cultural Significance of Film Color White (영화색채 하양의 활용 양상과 문화적 의미)

  • Kim, Jong-Guk
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.4
    • /
    • pp.187-198
    • /
    • 2020
  • With the cultural background of whiteness I did examine the universal meaning of absolute good, the special of psychosis, and the fantastic of femininity and memory/record. As an example I analyzed the symbolic meaning of white used in Korean films. Unconditional goodness, white as a generality: White color in all the films of good-evil confrontation falls into this category. The most obvious and the simplest configuration are the black-white dichotomy. In Nameless Gangster: Rules of Time(2011), The Merciless(2016), Asura: The City of Madness(2016) and The Bad Guys: Reign of Chaos(2019), white is the absolute good but it is not limited to a fair key figure. Paradoxically, black is not given only to the side of absolute evil. White is used to be a flexible visual device that reflects the socio-political situation without changing the meaning of the general good. Psychosis and pills, white as a peculiarity: The visual function that emphasizes sado-masochism in the absolute good and the universal symbol of white extends to psychotic specificities such as hysteria. In all the films creating horror, white symbolizes the mentally disabled and the pill for healing. Femininity and haunted white: White of absolute good is expressed by the socio-cultural tendency of femininity and the black-white contrast of vision is applied to the gender difference. In general the women's sexuality is emphasized in color red, but white is arranged in the background. In TaeGukGi: Brotherhood Of War(2004), 71: Into The Fire(2010), My Way(2011), The Front Line(2011), Roaring Currents(2014), Northern Limit Line(2015), The Battle: Roar to Victory(2019) and Battle of Jangsari(2019), white given to female figures sticks to the traditional femininity such as motherhood, sacrifice and weakness. The concept of specters is applied to desires, memories/records, history, fantasy, virtual/reality and social media images. The film history capturing to list memories and moments brings up the specters of socio-political genealogy. Most of films aiming for socio-political change are its examples and white constituting Mise-en-scene records to remember a historical event in Peppermint Candy(2000), The Attorney(2013) and A Taxi Driver(2017).

Observation of Volume Change and Subsidence at a Coal Waste Dump in Jangseong-dong, Taebaek-si, Gangwon-do by Using Digital Elevation Models and PSInSAR Technique (수치표고모델 및 PSInSAR 기법을 이용한 강원도 태백시 장성동 폐석적치장의 적치량과 침하관측)

  • Choi, Euncheol;Moon, Jihyun;Kang, Taemin;Lee, Hoonyol
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_1
    • /
    • pp.1371-1383
    • /
    • 2022
  • In this study, the amount of coal waste dump was calculated using six Digital Elevation Models (DEMs) produced between 2006 and 2018 in Jangseong-dong, Taebaek-si, Gangwon-do, and the subsidence was observed by applying the Persistent Scatterer Interferometric SAR (PSInSAR) technique on the Sentinel-1 SAR images. As a result of depositing activities using DEMs, a total of 1,668,980 m3 of coal waste was deposited over a period of about 12 years from 2006 to 2018. The observed subsidence rate from PSInSAR was -32.3 mm/yr and -40.2 mm/yr from the ascending and descending orbits, respectively. As the thickness of the waste pile increased, the rate of subsidence increased, and the more recent the completion of the deposit, the faster the subsidence tended to occur. The subsidence rates from the ascending and descending orbits were converted to vertical and horizontal east-west components, and 22 random reference points were set to compare the subsidence rate, the waste rock thickness, and the time of depositing completion. As a result, the subsidence rate of the reference point tended to increase as the thickness of the waste became thicker, similar to the PSInSAR results in relation to the waste thickness. On the other hand, there was no clear correlation between the completion time of the deposits and the rate Of subsidence at the reference points. This is because the time of completion of the deposits at all but 5 of the 22 reference points was too biased in 2010 and the correlation analysis was meaningless. As in this study, the use of DEM and PSInSAR is expected to be an effective alternative to compensate for the lack of field data in the safety management of coal waste deposits.