• Title/Summary/Keyword: Korean image

Search Result 29,473, Processing Time 0.065 seconds

A Study on Sensibility Evaluation of Ceramic Surface: Comparison between Tactility and Visual Tactility (세라믹 표면의 감성 평가 연구: 촉감과 시각적 촉감의 비교를 중심으로)

  • Kim, Jihyun;Song, Min Jeong
    • Science of Emotion and Sensibility
    • /
    • v.19 no.2
    • /
    • pp.101-112
    • /
    • 2016
  • Selecting appropriate materials can be significantly important to make different image in the product and also give distinguished express to the users. A material for the ceramic product surface consists of the combination between a glaze and a body, and each attribution of materials and the way of the combination creates different texture and color. This study analyzes the difference between visually and tactually sensibility of ceramic surface to through the simulating both visual and tactual stimulation by verbal evaluation method. Totally 13 adjectives are selected from homepage of local and global ceramic product brand. And totally 12 ceramic samples are created with the consideration of color, glossiness and roughness. These 12 samples are the combination between four ceramic bodies (White porcelain, Celadon_c, Sancheong and Black soil) and three glazes (Transparent, Celadon_g, Black glaze). The respondents of first survey were asked to rub, touch and hold before evaluating the sensibility of ceramic surface and other respondents of second survey were asked to evaluate visual images of 9 samples which showed meaningfully difference from first survey. The surface which scored the highest sensibility with the first survey was 'pure' on a surface of White porcelain body with Transparent glaze, and the lowest was also 'pure' on a surface of Black soil body with Transparent glaze. The highest score in the second survey was the same result as the first survey, but the lowest scored 'casual' and the surface was Black soil body with Celadon glaze. By the comparison with two survey results, not every sensibility is same result shown as the first survey and the second survey, but the tactile sensibilities such as 'artistic', 'luxurious', 'sensuous', 'romantic' and 'mysterious' can be experienced by via visual materials of ceramic surfaces.

Acromial Morphology in Different MR Oblique Sagittal Slices: Correlation with Rotator Cuff Disorder (자기 공명 영상의 사 시상면에서의 견봉 형태의 변화: 회전근 개 질환과의 임상적 연관성 분석)

  • Jo, Chris H.;Kim, Ji-Beom;Choi, Hye-Yeon;Ko, Young-Whan;Yoon, Kang-Sup;Lee, Ji-Ho;Kang, Seung-Baik;Lee, Jae-Hyup;Han, Hyuk-Soo;Rhee, Seung-Whan
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.173-179
    • /
    • 2009
  • Purpose: On the hypothesis that the acromion morphology is changed according to the its site, we identified the morphology of the acromion on the oblique slices of MRI and we investigated the association of the acromial shape with the clinical stages of rotator cuff disorder on the magnetic resonance (MR) images. In addition, we compared the acromion morphology on MRI and simple X-rays. Material and Methods: The MR images of seventy one patients with rotator cuff disorder and who underwent arthroscopic surgery were compared with that of a control group of sixteen patients who didn't have rotator cuff disorder on MRI. On three subsequent oblique sagittal slices from the lateral edge of the acromion (S1, S2 and S3), each acromion morphology on the MRI slices was classified according to Epstein et al: flat, curved or hooked. We investigated the changing parttern of the acromion shape and we compared the acromion shape on MRI and that on simple X-rays. We classified the rotator cuff tear by the severity: bursitis, partial thickness tear or full thickness tear. We investigated which acromial type on the MRI oblique slice was associated with the severity of rotator cuff disease. Results: Changes of the acromial shape occurred in 54 patients (76.1%). The most frequent pattern was that the types are same on S1 and S2 and different on S3 (22 cases, 31.0%). The acromial type on S1 and S2 was significantly associated with the severity of rotator cuff disorder (p=0.001 and 0.022), respectively. There was no reliability of the acromial shape on MRI and roentgenography (p>0.05) Conclusion: The type of acromion changed from lateral to medial. Among the three positions, the shape of the acromion on S1 and S2 had meaningful correlation with the clinical stage of rotator cuff disorder. There was no statistical correlation of the acromial shape between MRI and simple X-ray.

A Study on the Artistic Techniques of the Chinese Early Cartoons -Focusing on Lian Huan Hua(連環畵) and - (중국 초기 만화 예술기법 연구 - 연환화 작품 <산향거변>과 <백모녀>를 중심으로-)

  • Lurenjing, Lurenjing
    • Cartoon and Animation Studies
    • /
    • s.39
    • /
    • pp.451-472
    • /
    • 2015
  • Lian Huan Hua(連環畵) has occurred in the history of China Cartoon was initially developed as a unique literary style of Chinese painting and narrative combined. Also Lian Huan Hua are also tend to form once the fusion 1920s was also a very creative fashion cartoon style. This is also referred to as chain cartoon. In 1950-1960, China 's Lian Huan Hua also mature a 'golden age' legal group reaches to indicate the unique formal features developed independently. This work is a dramatic expression of Lian Huan Hua narrative, shows a more realistic representation techniques and art forms such as portraiture is a very big breakthrough was achieved artistic maturity of the work increased significantly. by He You Zhi(賀友直) and by Hau San Chuan(華三川) is a masterpiece of artistry and maturity in the period leading side. Chapter 2 looked at the origin and development of Chinese Lian Huan Hua, it was seen by the fact that China achieved new progress in Lian Huan Hua upset every time the combination of content and form, In addition, the work of 1950-1960 in the development process of China's Lian Huan Hua confirmed the fact that they won the biggest achievement in artistry and maturity surface. Therefore, Chapter 3 how 'golden age' masterpiece of and the dramatic narrative of expression by analyzing a specific angle in the multifaceted image of the , realistic portraiture, such as the acquisition of Chinese concrete artistry Lian Huan Hua I want to show. Analysis of the figures depicting nature, landscape screens. consisted of highlights and background and techniques of utilization, production methods. The purpose of this research work is to identify two conditions of great Lian Huan Hua through analysis of concrete work and painting techniques such as framing and directing the Lian Huan Hua's artistic achievements is to investigate the influence of China in the early comics. These two works are focused on a realistic view of life and put out was to create a more effective representation of information it attempts to pass a new production techniques and will have the significance. Also completed was a new style absorbed throughout the aesthetic advantages are compelling own personality writers of Eastern and Western paintings are remarkable in that its performance. But the difference in the two works represent all types and painting techniques has a the mood of common China's lives.

A Study of Sound Expression in Webtoon (웹툰의 사운드 표현에 관한 연구)

  • Mok, Hae Jung
    • Cartoon and Animation Studies
    • /
    • s.36
    • /
    • pp.469-491
    • /
    • 2014
  • Webtoon has developed the method that makes it possible to express sound visually. Also we can also hear sound in webtoon through the development of web technology. It is natural that we analyze the sound that we can hear, but we can also analyze the sound that we can not hear. This study is based on 'dual code' in cognitive psychology. Cartoonists can make visual expression on the basis of auditive impression and memory, and readers can recall the sound through the process of memory and memory-retrieval. This study analyzes both audible sound and inaudable sound. Concise analysis owes the method to film sound theory. Three main factor, Volume, pitch, and tone are recognized by frequency in acoustics. On the other hand they are expressed by the thickness and site of line and image of sound source. The visual expression of in screen sound and off screen sound is related to the frame of comics. Generally the outside of frame means off sound, but some off sound is in the frame. In addition, horror comics use much sound for the effect of genre like horror film. When analyzing comics sound using this kinds of the method film sound analysis, we can find that webtoon has developed creative expression method comparing with simple ones of early comics. Especially arranging frames and expressing sound following and vertical moving are new ones in webtoon. Also types and arrangement of frame has been varied. BGM is the first in using audible sound and recently BGM composed mixing sound effect is being used. In addition, the program which makes it possible for readers to hear sound according to scroll moving. Especially horror genre raise the genre effects using this technology. Various methods of visualizing sound are being created, and the change shows that webtoon could be the model of convergence in contents.

The Evolution of Cyber Singer Viewed from the Coevolution of Man and Machine (인간과 기계의 공진화적 관점에서 바라본 사이버가수의 진화과정)

  • Kim, Dae-Woo
    • Cartoon and Animation Studies
    • /
    • s.39
    • /
    • pp.261-295
    • /
    • 2015
  • Cyber singer appeared in the late 1990s has disappeared briefly appeared. although a few attempts in the 2000s, it did not show significant successes. cyber singer was born thanks to the technical development of the IT industry and the emergence of an idol training system in the music industry. It was developed by Vocaloid 'Seeyou' starting from 'Adam'. cyber singer that differenatiated typical digital characters in a cartoon or game may be subject to idolize to the music as a medium. They also feature forming a plurality of fandom. therefore, such attempts and repeated failures, this could be considered a fashion, but it flew content creation and ongoing attempts to take advantage of the new media, such as Vocaloid can see that there are expectations for a true Cyber-born singer. Early-Cyber singer is made only resemble human appearance, but 'Sciart' and 'Seeyou' has been evolving to becoming more like the human capabilities. in this paper, stylized cyber singer had disappeared in the past in the process of developing the technology to evolve into own artificial life does not end in failure cases, gradually led to a change in public perceptions of the image look looking machine was an attempt in that sense. With the direction of the evolution of the mechanical function to obtain a human, fun and human exchanges and mutual feelings. And it is equipped with an artificial life form that evolved with it only in appearance and function. in order to support this logic, I refer to the study of the coevolution of man and machine at every Bruce Mazlish. And, I have analyzed the evolution of cyber singer Bruce research from the perspective of the development process since the late 1990s, the planning of the eight singers who have appeared and design of the cyber character and important voices to be evaluated as a singer (vocal). The machine has been evolving coevolution with humans. cyber singer ambivalent development targets are recognized, but strive to become the new artificial creatures of horror idea of human desire and death continues. therefore, the new Cyber-organisms are likely to be the same style as 'Seeyou'. because, cartoon forms and whirring voice may not be in the form of a signifier is the real human desires, but this is because the contemporary public's desire to be desired and the technical development of this type can be created at the point where the cross-signifier.

Design and Implementation of Web Based Instruction Based on Constructivism for Self-Directed Learning Ablity (구성주의 이론에 기반한 자기주도적 웹 기반 교육의 설계와 구현)

  • Kim Gi-Nam;Kim Eui-Jeong;Kim Chang-Suk
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.855-858
    • /
    • 2006
  • First of all, Developing information technology makes it possible to change a paradigm of all kinds of areas, including an education. Students can choose learning goals and objects themselves and acquire not the accumulation of knowledge but the method of their learning. Moreover, Teachers get to be adviser, and students play a key role in teaming. That is, the subject of leaning is students. Constructivism emphasizes the student-oriented environment of education, which corresponds to the characteristics of hypeimedia. In addition, Internet allows us to make a practical plan for constructivism. Web Based Internet provides us with a proper environment to make constructivism practice md causes an education system to change. Sure Web Based Instruction makes them motivated to learn more, they can gain plenty of information regardless of places or time. Besides, they are able to consult more up-to-date information regarding their learning use hypermedia such as an image, audio, video, and test, and effectively communicate with their instructor through a board, an e-mail, a chatting etc. A school and instructors have been making effort to develop a new model of a teaching method to cope with a new environment change. In this thesis, with 'Design and Implementation of Web Based Instruction Based on Constructivism', providing online learner-oriented and indexed video lesson, learners can get chance of self-oriented learning. In addition, learners doesn't have to cover all contents of a lesson but can choose contents they want to have from a indexed list of a lesson, and they ran search contents they want to have with a 'Keyword Search' on a main page, which can make learners improve learner's achievement.

  • PDF

A COMPARISON OF THE SHAPING ABILITY OF FOUR ROTARY NICKEL-TITANIUM FILES IN SIMULATED ROOT CANALS (엔진구동형 NiTi 파일의 근관성형효과 비교)

  • Kim, Bo-Hye;Choi, Kyoung-Kyu;Park, Sang-Hyuk;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.2
    • /
    • pp.88-95
    • /
    • 2010
  • The purpose of this study was to compare the root canal shaping ability of 4 rotary NiTi instruments in simulated root canals. For the preparation of thirty two curved root canals, Mtwo instruments using "single length"technique, and Profile, ProTaper Universal, and K3 using crown-down technique (N = 8) were used. All canal samples were prepared by reaching an apical canal size of #30. Pre- and post-instrumentation digital images were recorded and an assessment of canal shape was determined using a computer image analysis program SigmaScan Pro (Systat Software Inc., San Jose, CA, USA). The changes of the dimension of inner walls of canals, (2) the changes of the dimension of outer walls of canals, and (3) the centering ratio were measured at 7 measuring points, and then data were statistically analyzed using one-way ANOVA and Duncan's test. The results were as below; 1. The root canal shaping ability of Profile was significantly faster than that of other rotary NiTi instruments (p < 0.05). 2. The deformation and fracture of all instruments used for this study were not experienced. 3. In the degree of changes of the dimension of inner walls of canals, Profile demonstrated the lowest changes of the dimension of inner walls of canals except at the measuring points of the 1 and 2 mm (p < 0.05). However, the ProTaper Universal showed the highest changes of the dimension of inner walls of canals at all measuring points (p < 0.05). 4. In the degree of changes of the dimension of outer walls of canals, Mtwo demonstrated the lowest changse of the dimension of outer walls of canals except at the measuring point of the 1 mm (p < 0.05). However, Profile exhibited the highest changes of the dimension of outer walls of canals at the measuring points of 3 and 4 mm and ProTaper Universal and K3 showed the largest changes of the dimension of outer walls of canals at the measuring points of 1, 2, 6, and 7 mm (p < 0.05). 5. In degree of centering ratio, Profile demonstrated the least centering ratio comparing with the centering ratio shown by other NiTi instruments at the measuring points of 1, 4, 5, and 6 mm. Results suggest that in the coronal part of canal preparation, active cutting files such as ProTaper Universal may efficiently flare the canal orifice and form a better taper, and in the apical part of the canal, files which have a better centering ability such as Profile may maintain the original canal curvature and reduce the shaping time.

Entrance Skin Dose According to Age and Body Size for Pediatric Chest Radiography (소아 흉부촬영 시 나이와 체격에 따른 입사피부선량)

  • Shin, Gwi-Soon;Min, Ki-Yeul;Kim, Doo-Han;Lee, Kwang-Jae;Park, Ji-Hwan;Lee, Gui-Won
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.327-334
    • /
    • 2010
  • Exposure during childhood results in higher risk for certain detrimental cancers than exposure during adulthood. We measured entrance skin dose (ESD) under 7-year children undergoing chest imaging and compared the relationship between ESD and age, height, weight, chest thickness. Though it is important to measure chest thickness for setting up the exposure condition of chest examination, it is difficult to measure chest thickness of children. We set up exposure parameters according to age because chest thickness of children has correlation with age. In the exposure parameters, for chest A-P examination under 2 year-children, tube voltage (kVp) in hospital A was higher than that in hospital B while tube current (mAs) was higher in hospital B, thus the ESD values were about 1.7 times higher in hospital B. However, for chest P-A examination over 4 year-children, the tube voltage was 7 kVp higher in hospital B, the tube current were same in all two systems, and focus to image receptor distance (FID) in hospital B (180 cm) was longer than that in hospital A (130 cm), thus the ESD values were 1.4 times higher in hospital A. For same ages, the ESD values for chest A-P examinations were higher than those for chest P-A examinations. Comparing ESD according to age, ESD values were $154{\mu}Gy$, $194{\mu}Gy$ and $138{\mu}Gy$ for children under 1 year, 1 to under 4 years and 4 to under 7 years of age, respectively. These values were lower than reference level ($200{\mu}Gy$) recommended in JART (japan association of radiological technologists), however these were higher than reference values recommended by EC (european commission), NRPB (national radiological protection board) and NIFDS (national institute of food & drug safety evaluation). In conclusion, the values of ESD were affected by exposure parameters from radiographer's past experience more than x-ray system. ESD values for older children were not always higher than those for younger children. Therefore we need to establish our own DRLs (diagnostic reference levels) according to age of the children in order to optimize pediatric patient protection.

Development of Dynamic Kidney Phantom System and its Evaluation of Usability of Application in Nuclear Medicine (핵의학 동적 신장팬텀시스템 개발 적용의 유용성 평가)

  • Park, Hoon-Hee;Lee, Juyoung;Kim, Sang-Wook;Lyu, Kwang Yeul;Jin, Gye Hwan
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.49-55
    • /
    • 2013
  • Currently, commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desires to evaluate the usefulness of nuclear medicine imaging. The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study, it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc$-pertechnate. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn five times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Depending on the speed of injection, radioisotope was a lot of integrated and emissions up when adjusting the pressure of the pump as 30 stroke, it was the least integrated and emissions up when adjusting as 40 stroke. The integration of the left & right kidney was not reached in the amount of the highest when adjusting as 10 stroke. In the changes according to the amount of the radioactive isotope, 0.6 mCi(22.2 MBq), 0.8 mCi (29.6 MBq)was showed up similar tendency but, in the result of the different injection 0.8 mCi, it was showed up counts close to double of 0.6 mCi. In the result of the differently injection speed of the left & right kidney, as a result of different conditions that injection speed was 20 stroke through left kidney phantom, the injection speed was 30 stroke through right kidney phantom, it was enough difference in the resulting image can be easily distinguished with the naked eye. Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical practice. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

Comparison of Noise Power Spectrum Methodologies in Measurements by Using Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료시 전자포털영상장치를 이용한 잡음전력스펙트럼 방법론 측정비교)

  • Son, Soon-Yong;Choi, Kwan-Woo;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.99-105
    • /
    • 2016
  • The noise power spectrum (NPS) is one of the most general methods for measuring the noise amplitude and the quality of an image acquired from a uniform radiation field. The purpose of this study was to compare different NPS methodologies by using megavoltage X-ray energies. The NPS evaluation methods in diagnostic radiation were applied to therapy using the International Electro-technical Commission standard (IEC 62220-1). Various radiation therapy (RT) devices such as TrueBeam$^{TM}$(Varian), BEAMVIEW$^{PLUS}$(Siemens), iViewGT(Elekta) and Clinac$^R$ iX (Varian) were used. In order to measure the region of interest (ROI) of the NPS, we used the following four factors: the overlapping impact, the non-overlapping impact, the flatness and penumbra. As for NPS results, iViewGT(Elekta) had the higher amplitude of noise, compared to BEAMVIEW$^{PLUS}$ (Siemens), TrueBeam$^{TM}$(Varian) flattening filter, Clinac$^{R}$iXaS1000(Varian) and TrueBeam$^{TM}$(Varian) flattening filter free. The present study revealed that various factors could be employed to produce megavoltage imaging (MVI) of the NPS and as a baseline standard for NPS methodologies control in MVI.